Survey
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
4 Electricity and Magnetism 6 Chapter 6 Transmission of Electricity Transmission of Electricity Practice 6.1 (p. 262) 1 D 2 D For the sinusoidal current, I Irms = 0 2 A square wave can have constant magnitude. 3 Therefore, I 0 = 12.5 2 (a) This is an a.c. Let T be the period. Required steady current = I2 = I0 = 5 A 2 0.5T 2 0.5T =2A T 2 2 The peak value of the sinusoidal current is 5 A. Alternative solution: Since the value of I2 (c) (i) For sinusoidal current: is always the same (= 22), the required steady current = 2 2 = 2A. (b) This is an a.c. Required steady current I 4 = 0 = = 2.83 A 2 2 (c) This is a d.c. Let T be the period. For square current: Required steady current = I2 = 4 4 2 0.5T 2 2 0.5T = 3.16 A T Billy is wrong. The rated value means that the light bulb is working at an r.m.s. voltage of 220 V to give an average power of 60 W. 5 (a) The current shown in Figure a is an a.c. while the current shown in Figure b is a (ii) No. For the case of sinusoidal current, d.c. the current through the resistor (b) Since the average power dissipated is the becomes zero in some periods of time, same for both currents, by P = Irms2R, the and so the average power dissipated r.m.s. value of the currents are the same. decreases. Therefore, the average Let I0 be the peak value of the sinusoidal power dissipated is now smaller than current. that in the case of square current. For the square current, Irms = I 2 = Practice 6.2 (p. 280) 5 2 0.5T = 12.5 T New Senior Secondary Physics at Work 1 1 C Oxford University Press 2010 4 Electricity and Magnetism Chapter 6 Transmission of Electricity 2 D (b) This is because power station needs a huge 3 A amount of water for cooling down steam in 4 B the condenser. 5 C 6 P 50 1000 (a) I = = = 200 A 250 V (c) The power loss in transmission cable will be reduced if voltage is stepped up before transmission. Power lost in the cable (d) This is because a.c. can be stepped up and = I2R = 2002 0.15 = 6000 W stepped down easily for transmission. N p Vp 220 10 (a) Turns ratio = = = = 22 : 1 N s Vs 10 (b) Voltage across cables = IR = 200 0.15 = 30 V Supply voltage at the hospital (b) Power taken by the bulb = 250 30 = 220 V = VI = 10 0.5 = 5 W Therefore, 220 V a.c. equipment rated can 7 (c) The efficiency of the transformer is 100%, be used properly. P 1000 I= = = 4.545 A 220 V i.e. no power loss. Hence, power taken from the mains = power taken by the bulb = 5 W Voltage across cables (d) Current drawn from the mains P 5 = = = 0.0227 A V 220 = IR = 4.545 5 = 22.7 V Voltage available for the appliance 8 = 220 22.7 = 197 V l (a) By R = , A 11 At the transmission cable, voltage = V2, power = 0.9P By P = VI, length of the copper cable = RA = 0.5 3 10 6 16 .8 10 9 current flowing through the cable = = 89.3 m By P = I2R, (b) Voltage across cables 2 0.9 P R power loss in the cable = V2 = IR = 12 0.5 = 6 V Supply voltage to house = 220 – 6 = 214 V = (c) Power supplied from the power pole = VI = 220 12 = 2640 W (d) Power loss in cables 12 By P = = I2R = 122 0.5 = 72 W 0.81 P 2 R V2 2 V2 , R resistance of each bulb = Power loss percentage 72 100 % = 2.73% = 2640 9 0.9 P V2 62 =18 2 (a) By conservation of energy, 12Ip = (a) Steam is needed in power station to drive the steam turbine which in turn drives the 12 2 62 + 18 2 18 Ip = 0.5 A alternator in the power station. New Senior Secondary Physics at Work 2 Oxford University Press 2010 4 Electricity and Magnetism Chapter 6 Transmission of Electricity Conventional (p. 284) (b) By conservation of energy, 2 12Ip = 6 3 18 1 Ip = 0.5 A (c) By conservation of energy, 62 62 12Ip = 2+ 18 18 Ip = 0.5 A Switch S Switch S is closed is open case (i) case(ii) Power of bulb X P P 4P Voltmeter reading V V V Ammeter reading I 2I 2I (6 1A) 13 (a) Vp = 1 5 = 5 V 2 Vs = 3.5 5 = 17.5 V Vp 5 Voltage ratio = = = 0.286 : 1 V s 17 .5 (b) By Np (1M) current passing through the bulb P 24 = = =2A V 12 Vp , Vs V 17 .5 Ns = Np s = 100 = 350 Vp 5 Ns = (a) By P = VI, (b) By P = VI, current in the cables 24 P = = = 0.1 A V 12 20 The number of turns in the secondary coil Power loss in the cables is 350. = I2R = 0.12 10 = 0.1 W (c) When one of the C-cores is removed, just a (c) By P = VI, small fraction of the magnetic field lines through the secondary coil. This reduces the induced voltage across the secondary coil. Therefore, the voltage ratio, Vs much larger than the turns ratio, 3 , would be Np Ns . 2 A 3 B 4 (HKALE 2004 Paper II Q27) 5 (HKALE 2007 Paper II Q37) = I 2R (1A) (1M) (1A) (1M) = 1000 0.1 2 = 100 000 W = 100 kW (1A) (iii) By P = VI, voltage available at the village P = I 220 000 100 000 = 1000 = 120 V New Senior Secondary Physics at Work (1A) (ii) Power lost in the cables Multiple-choice (p. 284) B By P = VI, current in the cables P 220 000 = = = 1000 A 220 V Revision exercise 6 1 (a) (i) (1M) (1M) current in the 12-V a.c. supply P = V 24 0.1 = = 2.01 A 12 coming out of the primary coil would ‘cut’ Vp (1A) 3 (1A) Oxford University Press 2010 4 Electricity and Magnetism (Or Physics in articles (p. 287) By V = IR, (a) An alternating current varies periodically with voltage available at the village time in direction = 220 IR while a direct current always travels in one = 220 1000 0.1 direction, = 120 V (b) (i) Chapter 6 Transmission of Electricity (1A)) A step-down transformer (1A) with turns ratio 300 : 1 (1A) (1A) (1A) as shown in the following figures. should be connected to the transmission cable. (Correct circuit diagram.) (1A) (Correct labels.) P 220 000 (ii) I = = = 3.33 A 66 000 V (1A) (1M) Power loss in cables = I 2R (1M) = 3.33 0.1 2 = 1.11 W (1A) The power loss in cables is much (Correct example of a.c.) (1A) (Correct example of d.c.) (1A) (b) Transformers can step up/down voltages.(1A) reduced, so power should be transmitted at 66 kV. (1A) (c) Any one of the following: (1A) (c) The power loss in transmission can be reduced if electricity is transmitted at a high voltage. (1A) Shorten the length of transmission cables. The voltage of a.c. can be stepped up and down Reduce the resistance of cables. 4 (HKCEE 2000 Paper I Q10) easily by transformers while the voltage of d.c. 5 (HKCEE 2005 Paper I Q12) cannot. 6 (HKALE 2005 Paper II Q4) Since the power loss in d.c. transmission is (1A) large, a lot of generating units are needed along the path of transmission. New Senior Secondary Physics at Work 4 (1A) Oxford University Press 2010