* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download World of Automation
Survey
Document related concepts
Flip-flop (electronics) wikipedia , lookup
Solar micro-inverter wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Voltage regulator wikipedia , lookup
Power electronics wikipedia , lookup
Buck converter wikipedia , lookup
Voltage optimisation wikipedia , lookup
Immunity-aware programming wikipedia , lookup
Schmitt trigger wikipedia , lookup
Power supply wikipedia , lookup
Mains electricity wikipedia , lookup
Transcript
World of Automation Chapter 7: SLS-86 Series www.hiquel.com Index Index 7 Chapter 7: SLS-86 Series .01 INFO SLS-86 series .02 INFO SLS-86 programming .03 INFO bit processing .04 INFO overview compact modules HI-86 .05 HI-86 Starter Kit & minimodule .06 SLS-86-R Starter Kit & base module .07 SLS-D .08 SLS-D..-16A .09 SLS-8DI .10 SLS-8D .11 SLS-FBR .12 SLS-PTC .13 SLS-PT100 .14 SLS-PT1000 .15 SLS-AU .16 SLS-AI HIQUEL 2009 X01.00 HIGH QUALITY ELECTRONICS 7:00 building / industrial automation SLS-86 Series 8 Bit processing The PLC-series SLS-86 is a central and/or distributed PLC system with a modular concept. HI-86 is the compact control of the SLS-86 series. in U 0-10V The base module allows easy and cost-effective communication with up to 31 different expansion modules over a bus length of up to 600m. The modules can be connected either locally by recessed side connectors for side by side DIN rail mounting or remotely via CAT5 cable. SLS-86 base module SLS-86 SLS I/O SLS-86 expansion modules local connection 6 Connection: local and remote versions of all modules available digital input modules 24Vdc or 100-240Vac out digital output modules, relays, transistor or photomos DIN SLS I/O remote connection using CAT5 cable remote connection SLS I/O analogue I/O modules 0-10V or 0-20mA temperature detection modules for PTC, Pt100- and PT1000 sensors 16bit analogue input modules; 0-10V or 0-20mA local connection RS485 up to 31 I/O modules room temperature detection modules with 4 inputs room temperature controller RS232 RTC Programming without special software knowledge, suitable for small (8/6 I/O) and medium sized (up to 250 I/O) applications. The SOLUTION SLS86 is a modular programmable (intelligent) relay that can be used in many fields including industrial control, automation, and building management. The base module SLS 86 has 8 digital inputs (4 dual digital or analogue), and 6 relay outputs. The user program memory is 8kB with 64kB internal flash and a SIM-card for program copy and module to module data transfer. A range of extension modules (digital, analogue, PTC, PT100, PT1000, FBR) is available. Output types are relay, photomos (solid state) or transistor. The base module can communicate with up to 31 extension modules via recessed side connectors for side by side DIN rail mounting (local) or via CAT5 cable (remote). Up to 250 I/O can be distributed over a maximum distance of 600m. Analogue values can be set by potentiometers located on the front plate or by PC. Communication with HIQUEL TERM4 is possible using the host switches and host relay functions. Applications: r industrial automation r process control r building automation r transport system r machine control r pump control r lighting control r heating control r hydraulic systems r bespoke systems The HI-86 is a compact programmable (intelligent) relay that can be used in many fields. The minimodule HI-86 has 8 digital inputs (20-250Vac/dc) and 6 relay outputs (5Amp). The user program memory is 8kB. The RS 232 interface can be used for programming and monitoring. The HI-86 also features a SIM-card for easy program copy and module to module data transfer. 7:01 HIQUEL 2009 X01.00 HIGH QUALITY ELECTRONICS SoftWIRE and SoftwirePLUS are programs that are simple yet powerful CAD style wiring ladder diagram programs. Series: SLS-86, HI-86 in SoftwirePLUS: System configuration: Programming without special software knowledge. The SLS-86 base module is programmed with SoftwirePlus, using the principle of a wiring ladder diagram for programming. Many pre-programmed software modules are included such as star-delta start, DOL (direct on line) motor start, timing functions, output functions (on/off, set/reset, bi-stable), counters (non-volatile and volatile with 8 set points each) and a universal real time clock with calendar. The Real Time Clock can be programmed easily for point of time switching, (to perform a function at a fixed time/date) or time interval switching, (to perform a function between two times, dates, weeks, years etc). Days of the week, weeks of the year, days, months, years, date and time can be combined without problems. SoftwirePlus features on-line monitoring and status display of all I/O’s and internal program elements on the PC. It also automatically creates complete paper documentation (wiring diagram, program elements and cross-reference list). All program element addresses are automatically allocated and it is simple to change the screen and printout language into English, German, Italian up to 31 I/O modules possible U 0-10V out DIN Simple-to-use CAD style ladder diagram software: automatic addressing, simple editing RS485 of wiring scheme RS232 RTC with calendar function: days of the week, days of the week, days, months, years, date, time basic elements RTC SoftWIRE: Programming without special software knowledge. The compact module HI-86 is programmed with SoftWIRE offering easy programming via wiring diagram. A graphic symbol library for functions and settings are included in SoftWIRE software. There is no limitation of program elements on a ladder rung and of the number of circuit paths. SoftWIRE automatically generates a printable version of the project description and the module wiring diagram as well as a cross reference list. SoftWIRE features simple language selection by HIQUEL 2009 X01.00 HIGH QUALITY ELECTRONICS Programming with SoftWIRE and Softwire PLUS Programming 7:02 SLS-86 SoftwirePLUS building / industrial automation Bit processing Programming by wiring ladder diagram, SLS-86 8 Building technology in Easy programming by ladder diagram U SLS-86 modules can be either locally or remotely connected via internal RS485 network in an easy and cost-effective way. 0-10V Complete paper documentation is automatically created. 6 out Easy and cost-effective communication with up to 32 different extension modules over a bus length up to 600m. DIN RS485 Transport system The modules can be either local (plug connections) or remote connected (CAT5 connection). RS232 Material handling control for complex applications processing large data volumes, e.g. analogue values, status of counters or time parameters. Changes of values directly on the PC or display. The modular structure allows flexible adaption to changes in the transport process. RTC Machine control Stepper motor control Up and down counters Preselection counters External fieldbus connectivity using the host input and host output functions. Optimised display layout and automated address allocation for easy handling. Direct coupling via integrated RS232 to PC or text display. 7:03 HIQUEL 2009 X01.00 HIGH QUALITY ELECTRONICS HI-86 minimodule Programming with SoftWIRE 8 in 6 out DIN RS232 HI-86 compact module Compact module Machine control Easy programming via wiring diagram (ladder) with SoftWIRE. Manual settings can be adjusted easily without PC using the external potentiometers (2) located on the front plate. Simple documentation (printing). Ideal for controling pumps, heating , hydraulic systems, lighting... Language selection by mouse click: German, English, Italian, Spanish... Process control Programming without PLC knowledge, suitable for small applications. Graphic symbol library for functions and settings. Simple tool bar “drag & drop” selection. Easy and flexible program exchange without PC is guaranteed with SIM memory card (2kB user-program memory). No limitation of program elements on ladder rungs or function blocks. LED indicators for inputs, outputs, supply voltage stop and error. HIQUEL 2009 X01.00 HIGH QUALITY ELECTRONICS 7:04 compact module & starter kit starter kit overviewoverview Automation Software compact intelligent relay module Automation Software supply voltage 20-250V~= (10-40V= on request) 8 digital inputs 20-250V~= (10-40V=) 8 in 6 SPNO outputs max. 5A LED indicators for inputs and outputs 2 potentiometers 6 8kB user-program memory out 16 timers 8 counters 14 pre-programmable timing functions DIN HI-86 minimodule serial interface cable (programming cable) CD-ROM SoftWIRE SIM-Card input simulator manual 67.5mm DIN rail mount housing graphic programming with ‘SoftWIRE’ using wiring(ladder) diagram specification The compact programmable (intelligent) relay HI-86 is programmed with “SoftWIRE” wiring diagram and can be used in many fields. The minimodule HI-86 has 8 digital inputs (20-250Vac/dc), 6 relay outputs (5Amp)and a 8kB user program memory. The RS 232 interface can be used for programming and monitoring. It also features a SIM-card for easy program copy and module to module data transfer. L supply voltage 20-250V~= power consumption 6W nominal frequency range 48 - 63 Hz output relay specification DI7 DI8 DI5 DI6 DI4 DI2 DI3 CARD RS232 max. 5A 230V~ Ue/Ie AC-15 120V/1,5A Ue/Ie DC-13 24V/1A expected life time mechanical electrical input specification L RS232 all you need to get you going a starter kit: DI1 HI-86 mini module and starter kit HI-86 240V/1A SPNO 7 1 x 10 operations 1 x 105 operations 20 - 250V~= max. 1,3 mA program memory 8kB protection class terminals screws housing IP50 pozidrive 1 IP20 screw tightening torque 1,0 Nm weight 200g dimensions 67.5 x 85 x 75mm DO6 L L L C4-6 DO5 L DO4 L L C1-3 DO3 DO1 DO2 N *EN 60947-5-1 VDE 0435 L ordering information N part no ordering information HI-86 supply 20-250V~= input 6x SPNO inp. galv. iso.* no Gehäusetypen output outp. galv. iso.* 6x SPNO HI-86-R-Starter Kit HI-86-R + SoftWIRE + download cable + manual + SIM-Card + input simulator HI-86-SIM SIM-Card memory 2kB HI-Std-RS232 download cable yes housing types E * measurement input galvanically isolated from the power supply 7:05 X01.00 HIQUEL 2009 HIGH QUALITY ELECTRONICS SLS-86 SLS-86 compact module & starter kit overview Automation Software Automation Software system base module supply voltage 24V= in 6 SPCO outputs max. 5A RS232 interface for programming/monitoring RS485 interface to connect up to 31 SLS-I/O modules U LED indicators for inputs and outputs 0-10V 2 potentiometers 8kB user-program memory 32 timers, 32 counters real time clock (RTC) with calendar function all you need to get you going a starter kit: 67.5mm DIN rail mount housing graphical programming with ‘SoftwirePLUS’ by wiring diagram SLS-86-R 24V=(base module) serial interface cable (programming cable) CD-ROM SoftwirePLUS SIM-Card input simulator manual Specification 24V= ±10% 1W nominal max. 5A 230V~ SPNO 7 1 x 10 operations 1,0 Nm RS232 L2.DI3 RTC RS232 BUS RS485 L2.DO3 HOST L+ *EN 60947-5-1 VDE 0435 L2.C 67.5 x 85 x 75mm L2.DO2 210g dimensions L2.DO1 CARD weight RS485 L2.DI4 L2.DI1 housing IP50 pozidrive 1 L1.C screws screw tightening torque DIN - L1.DO3 protection class M- input specification program memory out + 5 1 x 10 operations 24V= max. 5 mA 8kB terminals IP20 L1.DO2 expected life time mechanical electrical L2.DI2 max. 60V~=/2A DC-13 photomos L1.DI3/Ai3 Ue The modular intelligent relay SLS86 is programmed with SoftwirePLUS andcan be used in many fields including industrial control, automation, and building management. The base module SLS 86 has 8 digital inputs (4 dual digital or analogue), 6 relay outputs, and a 8 kB user program memory with 64kB internal flash and a SIM-card for program copy and module to module data transfer as well as an integrated real time clock. 240V/1A L1.DI4/Ai4 120V/1,5A 24V/1A L1.DI2/Ai2 Ue/Ie AC-15 Ue/Ie DC-13 L1.DO1 output relay specification L1.DI1/Ai1 supply voltage power consumption 6 master controller and starter kit 8 8 digital inputs 24V= (4 dual d/a 0-10V) + L L L Ordering information L L L L N Gehäusetypen output outp. galv. iso. part no supply input SLS-86-R 24V= 8x 24V= no 6x SPNO yes E SLS-86-S 24V= 8x 24V= no 6x photomos yes E SLS-86-R-Starter Kit SLS-86-SIM SLS-86-R + SoftwirePLUS + download cable + manual + SIM-Card + input simulator SIM-Card memory 8kB inp. galv. iso. SLS-86-BUS bus termination for external I/O modules SLS-Std-RS232 download cable housing types * measurement input galvanically isolated from the power supply HIQUEL 2009 X01.00 HIGH QUALITY ELECTRONICS 7:06 SLS-D digital I/O module SLS-D overview digital I/O expansion module supply voltage 24V= 4 4 digital inputs 24V= in 4 outputs SPNO 230V~= max. 5A or transistor (PNP) 24V= max.800mA or photomos 60V~= max.2A local 4 out LED indicators for inputs and outputs RS485 interface 1 potentiometer pre-programmable timer functions DIN 45mm DIN rail mount housing RS485 specification remote supply voltage power consumption 24V= ±10% 0,5W nominal output relay specification Ue/Ie AC-15 max. 5A 230V~ 120V/1,5A 240V/1A Ue/Ie DC-13 + SPNO 1x107 operations electrical output transistor spec. 5 1x10 operations max. 800mA 24V= PNP max. 60V~=/2A output photomos spec. C- DI4 DI2 DI3 DI1 M- - input specification 24V= protection class min. 5 mA terminals IP20 screws IP50 housing pozidrive 1 screw tightening torque weight 0,6..0,8 Nm 140g dimensions 45 x 85 x 75mm -10 to +55 °C non condensing ROM DO4 L L L C1-4 DO2 DO3 DO1 RS485 L+ BUS 24V/1A expected life time mechanical operating conditions *EN 60947-5-1 VDE 0435 + L L N ordering information part no type supply input inp. galv. iso.* output outp. galv. iso.* SLS-DR-C local 24V= 4x 24V= yes 4x SPNO yes C SLS-DR-D remote 24V= 4x 24V= yes 4x SPNO yes C housing types SLS-DT-C local 24V= 4x 24V= yes 4x trans. PNP no C SLS-DT-D remote 24V= 4x 24V= yes 4x trans. PNP no C SLS-DS-C local 24V= 4x 24V= yes 4x photomos yes C SLS-DS-D remote 24V= 4x 24V= yes 4x photomos yes C * measurement input galvanically isolated from the power supply 7:07 HIQUEL 2009 X01.00 HIGH QUALITY ELECTRONICS overview digital I/O expansion module supply voltage 24V= 4 4 digital inputs 24V= or 230V~ in 4 SPNO outputs 250V~ max. 16A LED indicators for inputs and outputs RS485 interface 1 potentiometer 4 out pre-programmable timer functions 67,5mm DIN rail mount housing DIN RS485 specification power consumption 24V= ±10% 0,5W nominal output relay specification max. 16A 250V~ Ue/Ie AC-15 120V/3A Ue/Ie DC-13 24V/1,5A SPNO 7 1x10 operations -/~ 4 1x10 operations min. 1 mA / min. 3mA / * + 45 x 85 x 75mm -15 to +55 °C non condensing BUS RS485 K2 I O A K1 14 L+ *EN 60947-5-1 VDE 0435 K3 I O A K4 I O A K2 K3 43 140g dimensions I O A K4 44 weight K1 ROM C3-4 0,6..0,8 Nm Di4 screw tightening torque Di3 IP50 pozidrive 1 34 housing screws operating conditions 9 6 3 = Di2 IP20 24 terminals M- protection class 8 5 2 . 230V~ / 24V= 33 electrical input specification 7 4 1 0 Di1 mechanical 9 * 9=81 +/~ C1-2 expected life time 240V/3A 13/23 supply voltage SLS-D..-16A digital I/O module SLS-D..-16A + L L L L L N ordering information part no type supply input inp. galv. iso.* output local 24V= 4x 230V~ yes 4x SPNO outp. galv. iso.* yes housing types SLS-DRR-16A-C SLS-DRR-16A-D SLS-DR-16A-C remote local 24V= 24V= 4x 230V~ 4x 24V= yes yes 4x SPNO 4x SPNO yes yes E E SLS-DR-16A-D remote 24V= 4x 24V= yes 4x SPNO yes E E * measurement input galvanically isolated from the power supply HIQUEL 2009 X01.00 HIGH QUALITY ELECTRONICS 7:08 SLS-8DI digital input module SLS-8DI overview digital input expansion module supply voltage 24V= 8 8 digital inputs 24V= in LED indicators for inputs RS485 interface DIN 1 potentiometer local pre-programmable timer functions 45mm DIN rail mount housing RS485 specification 9 * 9=81 7 4 1 0 8 5 2 . 9 6 3 = remote / * + supply voltage 24V= ±10% power consumption 0,5W nominal 24V= input specification min. 5 mA + IP20 protection class terminals screws housing IP50 pozidrive 1 screw tightening torque weight 0,6..0,8 Nm 140g dimensions 45 x 85 x 75mm -10 to +55 °C non condensing operating conditions Di1 Di2 Di3 Di4 C- Di5 Di6 Di7 Di8 C- ML+ - ROM BUS RS485 - + ordering information part no type supply input inp. galv. iso.* output SLS-8DI-C local 24V= 8x 24V= yes - outp. galv. iso.* - SLS-8DI-D remote 24V= 8x 24V= yes - - housing types C C * measurement input galvanically isolated from the power supply 7:09 HIQUEL 2009 X01.00 HIGH QUALITY ELECTRONICS overview digital output expansion module supply voltage 24V= 8 8 outputs out SPNO 230V~= max. 5A or transistor (PNP) 24V= max. 800mA or photomos 60V~= max. 2A LED indicators for inputs and outputs DIN local RS485 interface 1 potentiometer pre-programmable timer functions RS485 45mm DIN rail mount housing specification supply voltage 24V= ±10% power consumption output relay specification 0,5W nominal max. 5A 230V~ Ue/Ie AC-15 Ue/Ie DC-13 expected life time 120V/1,5A 24V/1A 9 * 9=81 remote 7 4 1 0 240V/1A 8 5 2 . 9 6 3 = / * + SLS-8D digital output module SLS-8D SPNO 7 1x10 operations L max. 60V~=/2A terminals IP20 N L L L Do4 C1-4 Do8 45 x 85 x 75mm -15 to +55 °C non condensing C5-8 dimensions operating conditions 1,0 Nm Do2 140g Do3 screw tightening torque weight Do7 pozidrive 1 Do1 screws Do5 - IP50 housing L Do6 output transistor spec. output photomos spec. protection class 5 1x10 operations max. 800mA 24V= PNP M- electrical L+ mechanical L L L ROM BUS *EN 60947-5-1 VDE 0435 RS485 + L L N ordering information part no type supply input SLS-8DR-C local 24V= - SLS-8DR-D remote 24V= - Gehäusetypen inp. galv. iso.* output outp. galv. iso.* 8x SPNO yes - housing types C - 8x SPNO yes C - - 8x trans. PNP no C 24V= - - 8x trans. PNP no C local 24V= - - 8x photomos yes C remote 24V= - - 8x photomos yes C SLS-8DT-C local 24V= SLS-8DT-D remote SLS-8DS-C SLS-8DS-D * measurement input galvanically isolated from the power supply HIQUEL 2009 X01.00 HIGH QUALITY ELECTRONICS 7:10 overview digital room controller expansion module supply voltage 24V= 4 4 FBR inputs 24V= in 4 outputs SPNO 230V~= max. 5mA or transistor (PNP) 24V= max. 500A FBR LED indicators for inputs and outputs local room temperature controller with day / nightand auto-switch, temperature registration and temperature correction RS485 interface 4 1 potentiometer out pre-programmable timer functions 45mm DIN rail mount housing DIN specification RS485 remote supply voltage power consumption output relay specification FBR room controller module 2- wire connection to SLS-FBR module + max. 5A 230V~ 120V/1,5A Ue/Ie DC-13 24V/1A 240V/1A SPNO mechanical 1x107 operations electrical 1x10 operations 5 output transistor spec. max. 500mA 24V= PNP input specification 24V= FBR FBR FBR FBR min. 5 mA C- DI4 DI3 DI2 DI1 - ROM protection class terminals screws housing IP50 pozidrive 1 IP20 screw tightening torque 0,6..0,8 Nm weight 140g dimensions 45 x 85 x 75mm operating conditions -15 to +55 °C non condensing *EN 60947-5-1 VDE 0435 DO4 L L L C1-4 DO3 DO1 DO2 RS485 L+ BUS 24V= ±10% 0,5W nominal Ue/Ie AC-15 expected life time FBR M- SLS-FBR digital room controller module SLS-FBR + L L ordering information N part no type supply input inp. galv. iso.* output outp. galv. iso.* SLS-FBR-R-C local 24V= 4x 24V= yes 4x SPNO yes C SLS-FBR-R-D remote 24V= 4x 24V= yes 4x SPNO yes C SLS-FBR-T-C local 24V= 4x 24V= yes 4x trans. PNP no C SLS-FBR-T-D remote 24V= 4x 24V= yes 4x trans. PNP no C FBR please refer to page 03:08 housing types * measurement input galvanically isolated from the power supply 7:11 HIQUEL 2009 X01.00 HIGH QUALITY ELECTRONICS overview PTC (thermistor) input expansion module supply voltage 24V= 4 thermistor motor protection in 4 PTC inputs for PTC-sensors DIN 44081 4 transistor (PNP) outputs LED indicators for outputs local RS485 interface 1 potentiometer 4 out pre-programmable timer functions 45mm DIN rail mount housing PTC DIN specification supply voltage output transistor spec. max. 800mA 24V= PNP input specification RS485 remote power consumption 24V= ±10% 0,5W nominal PTC sensor input DIN 44081 max. 1.500 Ohm / 6 sensors trigger 3.100 Ohm ±10% reset 1.650 Ohm ±10% 0 -20 Ohm ±10% T T CT2 T ROM BUS RS485 DO3 DO4 DO1 DO2 L+ T L L L C1-4 45 x 85 x 75mm -15 to +55 °C non condensing operating conditions 4T1 dimensions 3T1 120g PTC PTC 0,6..0,8 Nm weight PTC screw tightening torque PTC - IP20 2T1 screws IP50 housing pozidrive 1 1T1 terminals M- short protection class SLS-PTC thermistor input module SLS-PTC + L - ordering information Gehäusetypen inp. galv. iso.* output outp. galv. iso.* part no type supply input SLS-PTC-C local 24V= 4x PTC no 4x trans. PNP no C SLS-PTC-D remote 24V= 4x PTC no 4x trans. PNP no C housing types * measurement input galvanically isolated from the power supply HIQUEL 2009 X01.00 HIGH QUALITY ELECTRONICS 7:12 overview PT100 input expansion module supply voltage 24V= 2 2 PT100 inputs in 4 transistor (PNP) outputs LED indicators for outputs RS485 interface 1 potentiometer local 4 out pre-programmable timer functions 45mm DIN rail mount housing C PT100 DIN specification RS485 remote supply voltage power consumption 1 PT100 4-wire connection PT100 1 3 2 5 4 2 PT100 3-wire connection PT100 3 max. 800mA 24V= PNP input specification PT100 element -50°C to +300°C 0,1°C repeat accuracy terminals IP20 protection class T T T dimensions operating conditions IP50 housing pozidrive 1 0,6..0,8 Nm 120g 45 x 85 x 75mm -15 to +55 °C non condensing 5 3 4 - 5 4 2 2 1 1 24V= ±10% 0,5W nominal output transistor spec. screws screw tightening torque weight PT100 M- SLS-PT100 temperature input module SLS-PT100 ROM DO4 L L L C 1-4 DO3 DO1 L+ T DO2 RS485 + L ordering information - part no type supply input inp. galv. iso.* output outp. galv. iso.* SLS-PT100-C local 24V= 2x PT100 no 4x trans. PNP no C SLS-PT100-D remote 24V= 2x PT100 no 4x trans. PNP no C housing types * The ordering information for various sensors you will find on page 03:23 * measurement input galvanically isolated from the power supply 7:13 HIQUEL 2009 X01.00 HIGH QUALITY ELECTRONICS overview PT1000 input expansion module supply voltage 24V= 4 up to 4 PT1000 inputs in 4 transistor (PNP) outputs LED indicators for outputs RS485 interface 1 potentiometer local pre-programmable timer functions 4 out 45mm DIN rail mount housing C PT1000 DIN specification PT1000 element -50°C to +300°C 4 PT1000 2-wire connection PT1000 protection class 0,1°C repeat accuracy terminals IP20 screws IP50 housing pozidrive 1 3 2 PT1000 5 4 0,6..0,8 Nm 120g 45 x 85 x 75mm -15 to +55 °C non condensing 4 - M- dimensions operating conditions 1 PT1000 T T T 5 screw tightening torque weight PT1000 2 input specification 3 output transistor spec. RS485 remote 24V= 0,5W nominal max. 800mA 24V= PNP 1 supply voltage power consumption ROM SLS-PT1000 temperature input module SLS-PT1000 DO4 L L L C 1-4 DO2 DO1 L+ T DO3 RS485 + L - ordering information part no Gehäusetypen inp. galv. iso.* output outp. galv. iso.* type supply input SLS-PT1000-C local 24V= 4x PT1000 no 4x trans. PNP no housing types C SLS-PT1000-D remote 24V= 4x PT1000 no 4x trans. PNP no C * The ordering information for various sensors you will find on page 03:23 * measurement input galvanically isolated from the power supply HIQUEL 2009 HIGH QUALITY ELECTRONICS X01.00 7:14 overview analogue I/O expansion module supply voltage 24V= 4 4 analogue inputs 0-10V in 1 analogue output 0-10V 4 transistor (PNP) outputs LED indicators for outputs local 4 out RS485 interface 1 potentiometer pre-programmable timer functions U 45mm DIN rail mount housing 0-10V DIN specification RS485 remote supply voltage power consumption transistor output spec. 24V= 0,5W nominal max. 800mA 24V= PNP max. 8kHz analogue output spec. resolution - repeat accuracy precision 010V 010V analogue input spec. 010V 010V resolution input resistance protection class AO1 AI3 AI4 AI2 AI1 010V M- ROM RS485 T 0 - 10V= max. 2mA 10 bit 0,1% ±0,5% 0 - 10V= 12 bit 50kOhm terminals housing IP20 IP50 screws screw tightening torque pozidrive 1 weight dimensions operating conditions 120g 45 x 85 x 75mm 0,6..0,8 Nm -15 to +55 °C non condensing T L L L C1-4 T DO3 DO1 L+ T DO4 BUS DO2 SLS-AU analogue I/O module (voltage) SLS-AU + L - ordering information part no type supply input inp. galv. iso.* output outp. galv. iso.* housing types SLS-AU-C local 24V= 4x 0-10V no 4x trans. PNP no C SLS-AU-D remote 24V= 4x 0-10V no 4x trans. PNP no C * The ordering information for various sensors you will find on page 03:23 * measurement input galvanically isolated from the power supply 7:15 HIQUEL 2009 X01.00 HIGH QUALITY ELECTRONICS overview analogue I/O expansion module supply voltage 24V= 4 4 analogue inputs 0-20mA in 1 analogue output 0-10V 4 transistor (PNP) outputs LED indicators for outputs local RS485 interface 1 potentiometer 4 out pre-programmable timer functions I 45mm DIN rail mount housing 4-20mA DIN specification 0,5W nominal max. 800mA 24V= PNP max. 8kHz - 0,1% 12 bit input resistance protection class 250 Ohm terminals screws IP50 housing pozidrive 1 weight 0,6..0,8 Nm 120g dimensions operating conditions 45 x 85 x 75mm -15 to +55 °C non condensing T T T AO1 M- IP20 AI4 ROM BUS RS485 DO1 L+ T L L L C1-4 screw tightening torque 010V 020mA DO4 resolution ±0,5% 0 - 20mA AI2 analogue input spec. AI3 repeat accuracy precision + 0 - 10V= max. 2mA 10 bit DO2 analogue output spec. resolution DO3 output transistor spec. RS485 remote 24V= AI1 supply voltage power consumption SLS-AI analogue I/O module (current) SLS-AI + L - ordering information part no SLS-AI-C type local supply 24V= input 4x 0-20mA SLS-AI-D remote 24V= 4x 0-20mA Gehäusetypen inp. galv. iso.* output outp. galv. iso.* 4x trans. PNP no no no 4x trans. PNP no housing types C C * The ordering information for various sensors you will find on page 03:23. * measurement input galvanically isolated from the power supply HIQUEL 2009 X01.00 HIGH QUALITY ELECTRONICS 7:16