Medium Voltage Starter Sales Checklist Complete and return this Medium Voltage Check List to assist in the engineering process of providing a properly manufactured Solid State Starter, which will meet customer specific requirements. Complete each section as this will ensure a timely and accurate response. Project Name and/or End-User: Contact Name: Phone Number: Email: SECTION A – Starter Application: Type of application Present starting method: Across the Line Wye-Delta Auto Transformer Other: Starts / Stops per day: 1-5 6 -10 11-15 16-20 Over 20 (please specify) Current Acceleration Time 1-5 seconds 6-10 seconds 16-20 seconds >20 seconds 11-15 seconds (please specify) Current Deceleration Time (if applicable) 1-5 seconds 6-10 seconds 16-20 seconds > 20 seconds 11-15 seconds (please specify) Power source Utility (Transformer feed capacity – kVA) Short Circuit MVA (I) Delta Wye 3 wire 4 wire Delta, Corner Grounded High resistance ground Solid Ground (please specify) Ungrounded Generator (Generator kW rating) (please specify) 100-035 Rev. D Date: 07/02/2014 1 of 4 Approval: Kaizen Team Medium Voltage Starter Sales Checklist Distance from Line to starter: < 250 ft. 251 - 500 ft. 501 - 750 ft. > 750 ft. (please specify) Conductor type: Shielded Non-Shielded Distance from Starter to motor : < 250 ft. 251-500 ft. 501-750 ft. > 750 ft. (please specify) Size and Quantity of Conductors: Line side Size: Load side Size: Line side Quantity: / PHASE Load side Quantity: /PHASE SECTION B - Motor Data: Type of motor: Induction Synchronous Wound Rotor Horsepower: (If Synchronous or Wound Rotor, see Section “E” or “F” for additional questions.) Motor voltage: 2300 4160 6900 13,800 Frequency: 25 Hz 50 Hz 60 Hz Other: Other: (please specify) (please specify) NEMA Design: FLA: 100-035 Rev. D “A” Service Factor: “B” “C” Motor LRA: Date: 07/02/2014 2 of 4 “D” “E” Motor Speed (RPM): Approval: Kaizen Team Medium Voltage Starter Sales Checklist SECTION C - Enclosure / Environment Data: Expected ambient temperature: Space heater: Yes Minimum: No “ High Size limitation: Altitude: Maximum: (Space Heater required if less than 0 C) Physical Location: Indoor Outdoor “ Wide ( please indicate above dimensions. ) up to 3,300ft. “ Deep above 3,300ft. (please specify) Excessive Vibration and or Noise: Color: Vibration Beige Noise ANSI 61 Grey Other: (standard) Cable Entry location: Top Bottom Neither (please specify) Cable Exit location: Top (standard) Horizontal Bus: Bottom (standard) NONE 800Amp 1200Amp 2000Amp (standard) Other: (please specify) Insulation on Bus: Yes (price adder) No (standard) UL Rating (NEMA Type): 1 3R 12 Other: (standard) (please specify) SECTION D - Miscellaneous: Disconnect: Fusible Disconnect Starting Method: Keypad None 2-Wire Control 3-Wire Control (standard) Other: (please specify) Across-The-Line Starting Option: Yes No (standard) 100-035 Rev. D Date: 07/02/2014 3 of 4 Approval: Kaizen Team Medium Voltage Starter Sales Checklist Will any of the following be present?: Power Factor Correction Capacitors Note: PFCC must be located on the Line side of the Starter and must be isolated from the line during starting. Lightning Arrestors Note: May be placed on either the Line or Load side of the Starter. Surge Capacitors Note: Must be at the motor terminals and must be isolated during starting to prevent Starter damage. SECTION E – Synchronous Motor Data: Normal Field Current: (ADC) Max Field Current: (ADC) Field Discharge Resistor Rating: Synchronous Motor Field Voltage: (VDC) SECTION F – Wound Rotor Motor Data: Wound Rotor Motor: Starting Duty Resistor Continuous Running Duty Resistor Quantity of steps/resistance: Present number of steps: Secondary Voltage: (VAC) Secondary Current: (Amps) SECTION G – Additional Modifications, Accessories and/or Information: Customer’s Signature Customer’s Company Date 100-035 Rev. D Date: 07/02/2014 4 of 4 Approval: Kaizen Team