* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download Synchronous condenser solutions
Telecommunications engineering wikipedia , lookup
Power over Ethernet wikipedia , lookup
Transmission line loudspeaker wikipedia , lookup
Induction motor wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Electrical substation wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Wireless power transfer wikipedia , lookup
Life-cycle greenhouse-gas emissions of energy sources wikipedia , lookup
Mains electricity wikipedia , lookup
Utility frequency wikipedia , lookup
Distributed generation wikipedia , lookup
Electric power transmission wikipedia , lookup
Distribution management system wikipedia , lookup
Electric power system wikipedia , lookup
Alternating current wikipedia , lookup
Electric machine wikipedia , lookup
Electrification wikipedia , lookup
The stable way Synchronous condenser solutions siemens.com/energy/facts Bringing grids in line with new requirements Global climate change poses new challenges for power generation and transmission. Innovative solutions will contribute to the reduction in CO2 emissions and an optimized use of energy resources. The most crucial points in today’s and tomorrow’s power supply are sustainability, security, and efficiency. Synchronous condenser solutions are being introduced worldwide to support today’s transmission system requirements. The addition of renewables-based power genera- 2 tion to the energy mix, phaseout of conventional power plants, new HVDC systems, and the extension of power supply systems to remote areas influence the stability of transmission networks. Siemens offers tailor-made turnkey synchronous condensers to address the customers’ needs based on proven, reliable in-house equipment, extensive know-how on transmission system requirements, and project execution experience. Benefits Applications • Short-circuit power capability Synchronous condensers support and improve power transmission quality in a wide range of applications: • Reactive power compensation • Short-term overload capability • Inertia to the transmission system • Leveling out of »grid signals« • Support of grid to island operation capabilities • Stabilization of grids •High-voltage DC transmission links based on line-commutated converter technology •Transmission grids with a high amount of power infeed from renewable sources • Retirement/shutdown of conventional power plants 3 Technology and system overview Siemens synchronous condenser solutions comprise a horizontal synchronous generator connected to the high-voltage transmission network via a step-up transformer. Siemens supplies a broad range of generators up to 2,235 MVA. The generators are air-, hydrogen-, and water-cooled. The synchronous generator is started up and stopped by a frequency-controlled electric motor (pony motor) or a starting frequency converter. When the generator has reached an operating speed that is synchronous to the system frequency, it is synchronized with the transmission network and acts as a motor providing reactive and short-circuit power to the transmission network. Synchronous electrical machines like synchronous generators can generally be used as synchronous condensers. Without active power delivery or consumption, the machines can act in the same way as a capacitor or a reactor, depending on the excitation field current. 8 5 9 2 3 4 7 1 1 Synchronous generator 2 Generator step-up transformer 3 Static/brushless excitation 4 Pony motor/starting frequency converter 5 Isolated phase bus duct 6 Control and protection system 7 Auxiliary transformer 8 Generator circuit breaker 9 Optional external coolers 10 Complete civil and construction works Siemens in-house equipment System overview – synchronous condenser solution 4 6 10 Proven, reliable in-house products Generators A generator is an electric machine that converts mechani cal energy into electric power. It operates on the basis of the dynamoelectric principle that Werner von Siemens registered for a patent with the first dynamo generator in 1867. The principle states that an electric generator does not need to have an electric current supplied from the outside to start generating electric power. A self-reinforcing electrical induction can take place due to the residual magnetism of iron. Today, the mechanical excitation, the generator’s need to generate electricity, is often provided by a turbine. It drives a shaft that is known as the rotor. This shaft rotates in the stator core, in other words, inside the generator. The rotor is equipped with an electromagnet, and the moving magnetic field of the rotor causes a charge transfer in the conductor coils of the stator. The charge transfer generates electric voltage between the ends of the conductors. This is how the mechanical energy, which acts on the rotor, produces electric energy – power – in the stator. Excitation systems The generator is equipped with either a brushless exciter or a conventional static exciter with brushes. The two solutions have different characteristics in terms of dynamic behavior, and are selected according to the project requirements. Contrary to power electronics-based static VAr compensators (SVCs), a synchronous condenser features the major advantages of injecting large amounts of short-circuit power and providing inertia due to its rotating mass. The same generators are implemented for synchronous condenser applications. Starting frequency converter/pony motor The startup and breaking system of a Siemens synchronous condenser is either based on a frequency-controlled pony motor or a starting frequency converter. These two methods have different advantages and will be offered from Siemens’ own portfolio depending on the customer’s requirements. Control and protection system Generator performance is dynamically controlled by an automatic voltage regulator (AVR), which is an integral part of all excitation systems. In a brushless excitation system, the AVR is separately installed, and in case of static excitation system, AVR software is integrated in the control system of the static excitation system. In addition to the AVR system, a generator control panel is required for start and stop sequences, protection of the generator (vibration and temperature) and for cooling system control. Nuc Segment cooling H 2O 1000–2235 MVA (4-pole) 50 Hz 550–1300 MVA H2 Fossil 60 Hz 800–1065 MVA 50 Hz 350–570 MVA 60 Hz 310–540 MVA Manufacturing of an air-cooled generator Air Industrial 50 Hz 165–370 MVA 60 Hz 165–310 MVA 50/60 Hz 25–300 MVA 25–65 MVA (4-pole) The Siemens generator portfolio 5 Project references Black Sea 3x60 MVAr, Republic of Georgia Siemens installed three 60 MVAr synchronous condensers at the Georgia Black Sea HVDC station in June 2012. This synchronous condenser solution supports the transmission network between Georgia and Turkey with the required short-circuit power in order to operate the newly installed HVDC back-to-back station. Bjæverskov 1x250 MVAr, Denmark In Denmark, Siemens delivered a 250 MVAr synchronous condenser solution that started operation in 2013, providing the transmission system with a short-circuit power of more than 800 MVA in addition to reactive power control. The installation of this stand-alone synchronous condenser solution will enable the transmission system operator Energinet.dk to operate the transmission network without the need for a large thermal power plant. This makes the installation an economically and environmentally advantageous investment enabling the infeed of large amounts of renewable energy into the transmission network. 6 Fraugde and Herslev 2x200 MVAr, Denmark These solutions will ensure the transmission system stability in the country’s regions of Funen and Zealand. Siemens’ scope of supply comprises engineering, procurement, and construction of these facilities. The customer Energinet.dk will manage the civil work. Each synchronous condenser solution is capable of delivering more than 900 MVA of short-circuit power and +150 / -75 MVAr of reactive power. The projects are running in trial operation as of August 2014. Feda 1x200 MVAr, Norway This solution will secure short circuit power for the NorNed HVDC connection, especially during the planned upgrade of the overhead line in the southern region of Norway. Siemens’ scope of supply comprises engineering, procurement, and construction of these facilities including necessary civil works. The synchronous condenser solution for Feda is capable of delivering more than 750 MVA of short-circuit power and +170 / -90 MVAr of reactive power. The project is scheduled for trial operation at the end of 2014. Talega 2x225 MVAr, USA The turnkey supply of two 225 MVA synchronous condenser systems for Talega substation in California will support the California grid with reactive power, shortcircuit power, and inertia. Siemens’ scope of supply comprises the complete engineering, procurement, and construction of these facilities including necessary civil works. Each synchronous condenser solution for Talega is capable of delivering +225 / -120 MVAr of reactive power. The units are planned to commence commercial operation in July 2015. 7 Published by and copyright © 2014: Siemens AG Energy Sector Freyeslebenstrasse 1 91058 Erlangen, Germany Siemens AG Energy Management Division Freyerslebenstrasse 1 91058 Erlangen, Germany For more information, please contact our Customer Support Center. Phone: +49 180 524 70 00 Fax: +49 180 524 24 71 (Charges depending on provider) E-mail:[email protected] Order No. E50001-G610-A135-X-4A00 Printed in Germany Dispo 30003 fb 6407 WÜ 09141.0 Printed on elementary chlorine-free bleached paper. All rights reserved. Trademarks mentioned in this document are the property of Siemens AG, its affiliates, or their respective owners. Subject to change without prior notice. The information in this document contains general descriptions of the technical options available, which may not apply in all cases. The required technical options should therefore be specified in the contract.