Download PLX101C High Frequency Mobile X

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Electronic musical instrument wikipedia , lookup

Solar micro-inverter wikipedia , lookup

Cavity magnetron wikipedia , lookup

Power inverter wikipedia , lookup

Alternating current wikipedia , lookup

Switched-mode power supply wikipedia , lookup

Variable-frequency drive wikipedia , lookup

Distributed control system wikipedia , lookup

Control theory wikipedia , lookup

Resilient control systems wikipedia , lookup

Power electronics wikipedia , lookup

Islanding wikipedia , lookup

Mains electricity wikipedia , lookup

Control system wikipedia , lookup

Rectiverter wikipedia , lookup

CT scan wikipedia , lookup

Transcript
Shenzhen Cluss Medical Electronic Instrument Co.,ltd
CLS-10C High Frequency Mobile X-ray Equipment(5.0KW, 100mA)
Packing Details : 1220mm×900mm×1460mm ,
N.W. 142kgs
G.W.212kgs
1.7CBM
Specifications
Power Output:
Frequency :
X-ray Tube :
Focus
:
Tube Voltage :
Tube Current :
5.0KW
40KHz
Fixed anode
1.5
40~120KV (interval 1KV)
40~49KV
100mA 1~180 mAs
50~59KV
77mA 1~140 mAs
60~69KV
64mA 1~125 mAs
70~79KV
55mA 1~110 mAs
80~89KV
49mA 1~100 mAs
90~99KV
44mA 1~80 mAs
100~109KV 32mA
1~63 mAs
110~120KV 25mA
1~50 mAs
mAs
: 1.0~180 mAs (46 steps)
Power Supply:
220V±10% 50Hz inner-resistance≤1.0Ω
Operation Method: Wire/Wireless control , 20 meters microwave
remote control exposure. .( Advantage) . It is different from infrared
remote control exposure, does not suffer any obstacles in the way
I.Parameters
General-purpose, mobile X-ray system, dedicated for radiography of standing, seated or recumbent patients as well as for
patients in bed or on the operating table and as a standby emergency unit. High-frequency X-ray generator with the following
output:
1. Generator output:
5.0 kW
Shenzhen Cluss Medical Electronic Instrument Co.,ltd
2. kV range: 40 kV - 120 kV in 1kv steps
3. mA range:
25~100 mA
4. Exposure time: 4 films per min, less than 20 ms per film
5. X-ray tube:
Stationary anode tube with a focal spot of 1.5*1.5 mm
6. Collimator:
bright field light beam collimator with 120 W halogen lamp and auto shut-off facility.
7.Power requirements :Single phase 220 V +/- 10% Voltage tolerance; 50 Hz power supply
8.Mobile stand: Light-weight, low height mobile and easily maneuverable stand.
9.The mobile radiographic unit also include a handheld control and a microwave wireless remote control for the 20-meter
microwave remote Without the restriction of Barriers and directional ,different from the infrared remote control . Grids
reduce the fog line filters and raise the degree of scattering contrast.
10.The unit is provided with a line (power) cord of acceptable durability, quality, length and is secured with adequate
strain reliefs
The unit include, power plugs that are sufficient for the maximum voltage and current of the unit.
11. The maximum distance from the ground: ≥ 17500mm, and minimum distance from the ground :≤500mm, rotating
around the horizontal axis 180 °, rotation around the vertical: ± 90 °, The collimator can rotate 180 °,
II Standard Configuration
1 、Modular high-frequency and high-voltage X-ray generator; High-frequency inverter power.(5.0KW, 120KV, 100mA,
40KHZ)
one set
2、Innovative mobile X-ray photography Main frame
one set
3、Mobile X-ray photography control system
one set
4、Symmetric Adjustable beam limiter with light
one set
5、Remote controller ( Hand hold controller and Wireless Microwave control ,the distance is 20 meters )
one
set
6. 12” X 15” Image Intensify ,Cassette , Grid
one set
7、General spare parts
Several
2)
Options : CLS152 Table for Mobile X ray Equipment and Upright Bucky Stand
A. CLS152 Table ( Special for High Frequency Mobile X ray machine )
The size of CLS152 is 2000mm×700mm×500mm, cassette movement range is 1680mm . Low bed to facilitate the
Shenzhen Cluss Medical Electronic Instrument Co.,ltd
patient up and down, Longitudinal center of the bed frame with the cassette center line are consistent. To make the center
of symmetry when photograph,and the movement range of cassette get larger And have manual brakes convenient
location, bed body can 360 ° moving flexible
B. Upright Bucky Stand
The height : 1768 mm
Movement range of up and down : 470mm~1468 mm
Grid Density :103L/INCH
Grid Ratio : 10:1
Focus Distance : 150cm ,
Features: with Stationary Filter line, 18” X18” Can take maximum 17”X17” X ray film
Ⅲ、Usage
This is a modular X-ray photography medical diagnosis equipment, which is available for wards、emergency、
operating room、ICU and so on. An mobile diagnosis equipment for photography of body locutions such as head、arms、
thoracic cavity and waist abdomen.
Ⅳ..Features
◇ Lovely appearance, and easy to move and operate; Possess all the features of all the mobile X-ray photography machines.
◇ Rocker arm apply the patent technology of single-arm support and self-balanced. This technology makes the appearance and
operation much more beautiful and convenient.
◇ Apply the design of expansion gate design, the machine will automatically locked when hand-off which makes the
movement much safer.
◇ Apply the patent technology of auto-trim patent between arm rotation and battery box. The machine can automatically adjust
the barycentre according to the rotation angle of the arm. All this make the series the lightest and smallest and easy for
movement among like products.
◇ We incorporate the latest compact high-frequency and high-voltage X-ray generator, which ensure superior image quality,
while the skin dose is low , to protect the patient better.
◇ Adopt the technology of kV and mAs numeral closed loop control, Real-time control of the microprocessor, which ensure
the accuracy and repeatability of the output dose.
Shenzhen Cluss Medical Electronic Instrument Co.,ltd
◇ The parameter can be adjust by the KV and mAs two-button system. High- brightness、blue screen LCD display. With
multiple security protect function such as over-voltage, over-current.
◇ With 50 preset exposure programs, and can be modified and stored by the user for convenient operation.
◇ With a high-quality knockdown X-ray generator to reduce irradiation, which is much safer to environment and operator.
◇ Has a set of failure cascading failure function. Display the failure code. The system will automatically reset when the power
is off which ensure the information safe.
◇ With a symmetrical beam applicator to adjust the X-ray field and a collimator lamp to locate the filed to ensure accurate
radiograph.
◇ With high frequency inverter to emit high quality X-ray and low dose on skin, and ensure excellent definition and contrast of
pictures.
◇ The arms can rotate ±90°left and right. It is convenient to poisoning.
◇ Adopt manual control and remote control methods to control the photography function