Shenzhen Cluss Medical Electronic Instrument Co.,ltd CLS-10C High Frequency Mobile X-ray Equipment(5.0KW, 100mA) Packing Details : 1220mm×900mm×1460mm , N.W. 142kgs G.W.212kgs 1.7CBM Specifications Power Output: Frequency : X-ray Tube : Focus : Tube Voltage : Tube Current : 5.0KW 40KHz Fixed anode 1.5 40~120KV (interval 1KV) 40~49KV 100mA 1~180 mAs 50~59KV 77mA 1~140 mAs 60~69KV 64mA 1~125 mAs 70~79KV 55mA 1~110 mAs 80~89KV 49mA 1~100 mAs 90~99KV 44mA 1~80 mAs 100~109KV 32mA 1~63 mAs 110~120KV 25mA 1~50 mAs mAs : 1.0~180 mAs (46 steps) Power Supply: 220V±10% 50Hz inner-resistance≤1.0Ω Operation Method: Wire/Wireless control , 20 meters microwave remote control exposure. .( Advantage) . It is different from infrared remote control exposure, does not suffer any obstacles in the way I.Parameters General-purpose, mobile X-ray system, dedicated for radiography of standing, seated or recumbent patients as well as for patients in bed or on the operating table and as a standby emergency unit. High-frequency X-ray generator with the following output: 1. Generator output: 5.0 kW Shenzhen Cluss Medical Electronic Instrument Co.,ltd 2. kV range: 40 kV - 120 kV in 1kv steps 3. mA range: 25~100 mA 4. Exposure time: 4 films per min, less than 20 ms per film 5. X-ray tube: Stationary anode tube with a focal spot of 1.5*1.5 mm 6. Collimator: bright field light beam collimator with 120 W halogen lamp and auto shut-off facility. 7.Power requirements :Single phase 220 V +/- 10% Voltage tolerance; 50 Hz power supply 8.Mobile stand: Light-weight, low height mobile and easily maneuverable stand. 9.The mobile radiographic unit also include a handheld control and a microwave wireless remote control for the 20-meter microwave remote Without the restriction of Barriers and directional ,different from the infrared remote control . Grids reduce the fog line filters and raise the degree of scattering contrast. 10.The unit is provided with a line (power) cord of acceptable durability, quality, length and is secured with adequate strain reliefs The unit include, power plugs that are sufficient for the maximum voltage and current of the unit. 11. The maximum distance from the ground: ≥ 17500mm, and minimum distance from the ground :≤500mm, rotating around the horizontal axis 180 °, rotation around the vertical: ± 90 °, The collimator can rotate 180 °, II Standard Configuration 1 、Modular high-frequency and high-voltage X-ray generator; High-frequency inverter power.(5.0KW, 120KV, 100mA, 40KHZ) one set 2、Innovative mobile X-ray photography Main frame one set 3、Mobile X-ray photography control system one set 4、Symmetric Adjustable beam limiter with light one set 5、Remote controller ( Hand hold controller and Wireless Microwave control ,the distance is 20 meters ) one set 6. 12” X 15” Image Intensify ,Cassette , Grid one set 7、General spare parts Several 2) Options : CLS152 Table for Mobile X ray Equipment and Upright Bucky Stand A. CLS152 Table ( Special for High Frequency Mobile X ray machine ) The size of CLS152 is 2000mm×700mm×500mm, cassette movement range is 1680mm . Low bed to facilitate the Shenzhen Cluss Medical Electronic Instrument Co.,ltd patient up and down, Longitudinal center of the bed frame with the cassette center line are consistent. To make the center of symmetry when photograph,and the movement range of cassette get larger And have manual brakes convenient location, bed body can 360 ° moving flexible B. Upright Bucky Stand The height : 1768 mm Movement range of up and down : 470mm~1468 mm Grid Density :103L/INCH Grid Ratio : 10:1 Focus Distance : 150cm , Features: with Stationary Filter line, 18” X18” Can take maximum 17”X17” X ray film Ⅲ、Usage This is a modular X-ray photography medical diagnosis equipment, which is available for wards、emergency、 operating room、ICU and so on. An mobile diagnosis equipment for photography of body locutions such as head、arms、 thoracic cavity and waist abdomen. Ⅳ..Features ◇ Lovely appearance, and easy to move and operate; Possess all the features of all the mobile X-ray photography machines. ◇ Rocker arm apply the patent technology of single-arm support and self-balanced. This technology makes the appearance and operation much more beautiful and convenient. ◇ Apply the design of expansion gate design, the machine will automatically locked when hand-off which makes the movement much safer. ◇ Apply the patent technology of auto-trim patent between arm rotation and battery box. The machine can automatically adjust the barycentre according to the rotation angle of the arm. All this make the series the lightest and smallest and easy for movement among like products. ◇ We incorporate the latest compact high-frequency and high-voltage X-ray generator, which ensure superior image quality, while the skin dose is low , to protect the patient better. ◇ Adopt the technology of kV and mAs numeral closed loop control, Real-time control of the microprocessor, which ensure the accuracy and repeatability of the output dose. Shenzhen Cluss Medical Electronic Instrument Co.,ltd ◇ The parameter can be adjust by the KV and mAs two-button system. High- brightness、blue screen LCD display. With multiple security protect function such as over-voltage, over-current. ◇ With 50 preset exposure programs, and can be modified and stored by the user for convenient operation. ◇ With a high-quality knockdown X-ray generator to reduce irradiation, which is much safer to environment and operator. ◇ Has a set of failure cascading failure function. Display the failure code. The system will automatically reset when the power is off which ensure the information safe. ◇ With a symmetrical beam applicator to adjust the X-ray field and a collimator lamp to locate the filed to ensure accurate radiograph. ◇ With high frequency inverter to emit high quality X-ray and low dose on skin, and ensure excellent definition and contrast of pictures. ◇ The arms can rotate ±90°left and right. It is convenient to poisoning. ◇ Adopt manual control and remote control methods to control the photography function