2.2 Existing Facilities The physical plant consists of four structures totaling 48,427 Gross Square Footage (GSF) and 31,814 Net Assignable Square Footage (NASF). The Appalachian Laboratory building (#900) houses the main research laboratories on site. Additionally, the campus includes a greenhouse, garage, and chemical storage building (Illustration 2.1 and 2.5). Table 2.1 summarizes each physical structure at the AL campus, including construction dates, GSF, (NASF), and condition code. Each of the three levels of the main building (Building #900) are shown in illustrations 2.2, 2.3, 2.4 for a visual overview of the existing program. 1. AL Building Lobby The overall condition of the facilities is satisfactory with the exception of the greenhouse. The greenhouse, considered one of the research laboratories, requires major renovation or replacement within the next few years (Figure 3) Failure of the greenhouse plumbing system, which includes heating and cooling environmental controls, will force this facility to close, adversely impacting the research of multiple AL faculty. See Table 2.1 for more information. 900 Appalachian Laboratory Building The main building contains a classroom used for meetings and presentations; Interactive Video Network (IVN) room; administrative offices; faculty offices; graduate student offices; small conference room; library; laboratory support rooms; building and computing service areas; and research laboratories for water chemistry, soil and plant ecology, wildlife sciences, quantitative landscape ecology, watershed hydrology, stream ecology, forest ecology, general ecology, molecular ecology, and stable isotope research. A bridge within the three-story atrium connects the two-story administrative wing with the laboratory wing. 901 2. AL Greenhouse AL Chemical Storage Building The Chemical Storage Building provides safe, secure storage for faculty samples, hazardous materials and lab gasses. It is currently in satisfactory condition. 902 AL Greenhouse Built within a year of main building. Currently used by 2 researchers. Two water tanks with sensors feed the greenhouse and generator. Piping and heating is deteriorating and will require replacement within 5 years. The internal shading system within the greenhouse needs to be replaced. 3. AL Greenhouse - Deteriorating plumbing system III-10 903 AL Garage This structure provides grounds maintenance equipment storage. Currently the facility is in satisfactory condition. TABLE 2.1* Building Number 900 Building Name Appalachian Laboratory AL Chemical Storage AL Greenhouse Garage 901 902 903 AL Totals Total GSF 42,843 Building NASF 26,631 363 0.62 Year Constructed 1999 320 0.88 1999 145,817 1 14,582 4,226 3,799 0.90 1999 1,919,290 4 191,929 855 840 0.98 2000 76,950 1 5,130 48,287 31,590 Efficiency Replace Value 19,275,237 21,340,344 Condition Code 1 Renovation Cost 1,927,524 2,134,034 * Information for Table 2.1 was obtained from UMCES SGAP 2011. III-11 TABLE 2.2 The table below references the building condition codes from the previous Table 2.1. The percentages shown reflect the number of buildings with that particular code assigned to it. AL Building Condition (GSF) Code 4 25% Code 5 0% Code 3 0% Code 2 0% Code 6 0% Code 1 75% Building Condition Code: 1. Satisfactory Suitable for continued use with normal maintenance. Remodeling – A Requires restoration to present acceptable standards without major room changes, alterations, or modernization. The approximate cost of remodeling is not greater than 25% of the estimated replacement cost of the building. Remodeling - B Requires major updating and/or modernization of the building. The approximate cost of remodeling is greater than 25% but not greater that 50% of the estimated cost of the building. Remodeling - C Requires major remodeling of the building. The approximate cost of remodeling is greater than 50% of the remodeling/replacement cost of the building. 5. Demolition Should be demolished or abandoned because the building is unsafe or structurally unsound, irrespective of the need for the spa ce or the availability of funds for replacement. This category takes precedence over categories 1, 2, 3, and 4. 6. Termination Planned termination or relinquishing or occupancy of the building for reasons other than unsafeness or structural unsoundness, such as abandonment of the temporary units or vacating of leased space. This category takes precedence over categories 1, 2, 3, and 4. 2. 3. 4. III-12 '?'' LEGEND X01, X03,or X04 - Building Service Area Y04 - MeChanical Area 110 - Classroom 115 - Classroom Service 635 - Food Facility Service 310- Office • W06, W02,W04 or W05 - Circulation AL Building- Existing Program Level 01 NOT TO SCALE EBN -t........ LEGEND X01, X03,or X04 - Buildnig Service Area Y04 - MechanicalArea 350 - Conference Room •710 - CentralComputing/Telecomm •720 - Shop & Shop Service 310- Office • W06, W02, W04 or WOS- Circulation Area 315 - Office Service 250 - Research/Nonclass Laboratory •255 • Research/Nonclass Laboratory Service AL Building·Existing Program Level 02 NOT TO SCALE ffi,. .. J 0 L 1 ' - r• ,..,. , '+ -·.• ·r ·· ·- .•..,. 1 - , .,, "" .. r , ,.... -' · · · F n "W r-' '· ·c l _.,_ I · 1--"' v : ' ! [ , _ __ : • i. .•. : • : •: LEGEND : L ==== X01. X03,or X04 - Buliding Service Area Y04 - Mechanical Area 430 - Open Stack Study Room 310- Office • W06, W02, W04 or W05- Circulation Area ====d 315 - Office Service 250 - ResearcWNonclass Laboratory •255 • Research/Nonclass LaboratO<)' serv1ce lliUSft'auon 2.6 AL Building- Existing Program Level 03 NOT TO SCALE EBN Appalachian Laboratory Exterior Buildings Building 901 Greenhouse Zone2 Greenhouse Zone1 Mechanical Room .. Greenhouse Zone 3 Building 002 LEGEND !lU • 5S5 ·Greenhouse SeNice • 740 · Vehi:le Storage -760 H.;;, rdouc Ya!i!i.,r:.i¥ I Chemical storage Building Buildinq 903 Y04 - MechanicalRoom AL Ancillary Buildings 901. 902 and 903. NOT TO SCALE