Fire Alarm Systems | D7025 Alarm and Trouble Relay Module
D7025 Alarm and Trouble Relay Module
▶ Two Form C relays (alarm and trouble)
▶ 12 VDC or 24 VDC operation
▶ Easy installation onto the control panel
▶ No additional programming required after installation
The D7025 Alarm and Trouble Relay Module is a plug-in
device compatible with the D7022 Two-zone Fire Alarm
Control Panel (FACP). It allows the D7022 to support two
auxiliary Form C relays for connection to external devices
such as the D185 Reversing Relay Module, the D2071A
Digital Alarm Communicator Transmitter (DACT), or the
D9068 DACT. The module provides one alarm relay and one
trouble relay.
Certifications and Approvals
Region
Certification
USA
UL
UOJZ: Control Units, System (UL864, 9th
edition), UTOU: Control Units and
Accessories - Household System Type
(UL985)
CSFM
7167-1615: 162 and 7165-1615:
163 July 2008
Functions
Relays
The two Form C relays can be wired as either normallyclosed or normally-open. The alarm relay is used for external
devices that must operate when the control panel is in
alarm. The trouble relay is used for external devices that
must operate when the control panel indicates a trouble
condition.
The FACP holds the trouble relay energized in normal
standby. The C and NC terminals are connected in normal
standby. Loss of AC power does not activate the trouble
relay until the programmed AC fail timer expires.
Installation/Configuration Notes
Compatibility Information
Category
Product ID
Product Description
Control Panels
D7022
Two-zone FACP
Communication
D2071A
DACT
Devices
D2071AC
DACT with wired transformer
D2071ACT
DACT with plug-in transformer
D9068
DACT
D132B
Smoke detector reversing relay module
D185
Reversing polarity module
D7014
Class A zone converter module
D7015
Class A NAC converter module
D7025
Relay module
Modules
www.boschsecurity.com
2 | D7025 Alarm and Trouble Relay Module
Mounting Considerations
The D7025 mounts to the D7022 control panel with four
nylon stand-offs that are supplied with the D7025.
Note
AC and battery power must be removed from
the D7022 before installing the D7025.
Wiring Considerations
D7025 to FACP
The connector pins from the eight-pin connector on the
FACP board insert into the connector on the D7025.
Connect the yellow and green earth-ground wire to the
ground terminal on the FACP terminal strip.
Parts Included
Quant.
Component
1
Relay module
1
Hardware pack
1
Literature pack
Technical Specifications
Outputs
Active Current (both relays on):
60 mA
Relay Contact Current (maximum):
5 A at 30 VDC or 120 VAC (resistive)
Power Requirements
Current (standby):
30 mA
Voltage (operating):
12 VDC nominal or 24 VDC nominal supplied
by FACP
Ordering Information
D7025 Alarm and Trouble Relay Module
Provides one alarm relay and one trouble relay
Americas:
Bosch Security Systems, Inc.
130 Perinton Parkway
Fairport, New York, 14450, USA
Phone: +1 800 289 0096
Fax: +1 585 223 9180
[email protected]
www.boschsecurity.us
D7025
Europe, Middle East, Africa:
Bosch Security Systems B.V.
P.O. Box 80002
5600 JB Eindhoven, The Netherlands
Phone: + 31 40 2577 284
Fax: +31 40 2577 330
[email protected]
www.boschsecurity.com
© Bosch Security Systems Inc. 2010 | Data subject to change without notice
T1372047499 | Cur: en-US, V5, 4 Jul 2010
Asia-Pacific:
Represented by
Robert Bosch (SEA) Pte Ltd, Security Systems
11 Bishan Street 21
Singapore 573943
Phone: +65 6258 5511
Fax: +65 6571 2698
[email protected]
www.boschsecurity.com