Interface Terminal RXT Series Part Number Description RXT - ❶ ❶ Description F01 Q01 A01 B01 G04 G04N K04 K04H N08 N16 N321 P08 P16 P321 Relay Specification (TA-1a, TR-1a) Rated Current 250VAC 5A, 30VDC 5A Power Consumption 200mW (24VDC) Minimum load Current 100mA 5VDC Maximum Switching Current Time Life Cycle 5A Pick-up Time Approx. 8ms Drop Out Time Approx. 5ms Mechanical Life Cycle Min. 10,000,000 Electrical Life Cycle Min. 100,000 ☞ For the Motor Speed Controller, please use a product without the surge absorber. ☞ Select the Relay to be applied : RXT-K04(NAIS PQ1a), RXT-K04H(HR96A) RXT-K04M (omron relay) Relay Specification (TF-1c) Contact Ratings Coil Ratings Contact Form 1N/O + 1N/C Contact Material Silver Alloy (Gold plate) Maximum Contact Resistance 30mΩ Rated Current ( Resistance Load ) 6A 250VAC , 6A 30VDC Maximum Contact Capacity DC 180W AC 1500VA Maximum Rated Voltage 6A 250VAC Minimum Switching Current 1mA 5VDC Coil Voltage 5V 12V 24V Coil Consumption 170mW 24VDC Minimum Pick Up Voltage 70% of Nominal Voltage Maximum Drop-Out Voltage 5% of Nominal Voltage Operating Time Pick-up 8ms Drop-out 4ms Insulation Resistance Dielectirc Strength Gerneral Ratings Ⅲ - 34 Life Cycles 100MΩ Between Contact Points an Coil 4000VAC 1 minute Between Contact Points 1000VAC 1 minute Mechanical Min. 10,000,000 Electrical Min. 100,000 Vibration Resistance 10Hz to 55HZ 1mm DA Ambient Temperature -40°C to 85°C Ambient Humidity 5% to 85% RH Weight Approx. 3g Approval CE , VDE , UL Industrial Controls Catalog www.kacon.co.kr Rev. 2/14 Data subject may change without notice. Data Processing Product Selection Type Part Number Type Part Number RXT-A01 RXT-G04 (TF-1c) (TA-1a) (TA-1a) RXT-Q01 RXT-B01 RXT-K04H (TF-1c) (TA-1a) (HR96) RXT-N16 NPN (TA-1a) RXT-P16 PNP (TA-1a) RXT-N321 NPN (TA-1a) (TA-1a) RXT-P321 PNP (TA-1a) (TA-1a) Dimension & Diagrams (mm) RXT - F01 screw type RXT - Q01 pin type RXT - A01 10 RXT - B01 32 15 32 77 55 81.3 77 55 81.3 55.5 76.5 6.0 89.0 LED Lamp RXT - G04 (TA-1a relay mounted) RXT - G04N (Pa-1a relay mounted) 33 44.0max 7.62 31.8max 7.0 35.5 80 24.5 75 37.0 49 RXT - N16 33.5 4.4 76 31.5 15 41 35.5 80 75 57.6 52 67.0 35.0 3.0 57.6 5.5 52 33.5 67 5.5 32 134 141.5 151 143 49 24.5 134 141.5 151 41 143 2-M4 TAP RXT - N08 4.0 11.0 33.5 8.5 8.6 30 77.5 32 33 33 RXT - K04 (NAIS PQ1a Relay mounted) RXT - K04H (HR96A Relay mounted) 33.5 4.4 76 31.5 15 RXT - N321 36.5 70 35.0 19.5 167.0 38.0 Rev. 2/14 Data subject may change without notice. www.kacon.co.kr Industrial Controls Catalog Ⅲ - 35 Data Processing RXT-P08 PNP Type RXT-F01 RXT-N08 NPN Part Number Interface Terminal RXT-SDD10 ( 5 ~ 30VDC LOAD) Part Number Description RXT - ❶ ❷ ❸ ❹ ❶ Type S : SSR ❷ Control Voltage D : 4 ~ 32 VDC ❸ Load Voltage D : 5 ~ 30 VDC ❹ Load Current 10 : 10A General Specification ▶ Input Ratings (ambient temperature 25˚C) Rated Voltage 30 VDC Voltage Range 4 ~ 32VDC Control Voltage Levels Pick-up Voltage 4 ~ 32VDC Drop-Out Voltage Min. 4VDC Input Current 10 ± 3mA ▶ input Ratings (ambient temperature 25˚C) Format Item Rated Load Current Low Voltage 10A Rated Load Voltage 30V DC Load Voltage Range 5 ~ 30V DC Load Current 10A Peak Voltage 32VDC Insulation Resistance Max. 100MΩ (DC500V) Dielectric Strength 2500VAC, 50/60Hz for 1minute Vibration Resistance 10 ~ 55 ~ 10Hz Peak Amplitude 0.35mm (Durable Amplitude 0.7mm) Shock Resistance 294m/s2 Storage Temperature -30 to +100˚C (with no icing) Ambient Temperature -30 to +80˚C (with no icing) Ambient Humidity 45 to 85%RH DImension (mm) Wiring Terminal Y type (1.25-3Y) Ⅲ - 36 Industrial Controls Catalog www.kacon.co.kr O type (1.25-3O) Rev. 2/14 Data subject may change without notice. Interface Terminal CXT Series Part Number Description CXT - ❶ ❶ Description C20 C40 C401 W40 W50 General Specification Rated Current 1A Rated Voltage 125VAC Min. 100MΩ (500VDC) 600VAC rms 1 Minute Body Material Fire Resistance ABS Ambient Tempeature -40 ~ 55°C Tightening Torque 0.5N·m (5.10kgf·cm) Data Processing Insulation Resistance Dielectric Strength Product Selection CXT-C20 CXT-C401 CXT-W40 CXT-W50 Dimension & Diagrams (mm) CXT-C20 CXT-W40 104.0 90.0 85.8 44.5 35 130.0 115.0 42.0 42.0 47.5 45.5 45.5 47.5 10 35 CXT-W50 37.0 37.0 7.62 Connector side (HRS HIF3BA-20P) Terminal side CXT-C401 44.5 27.0 61 45.5 35.0 45.5 40.0 10 61 162 148.0 40.0 Rev. 2/14 Data subject may change without notice. www.kacon.co.kr Industrial Controls Catalog Ⅲ - 37 Interface Terminal Cable RXT, CXT Series Part Number Description RXT - ❶ ❷ ❸ ❹ ❶ PLC Maker MB : MITSUBISHI NA : NAIS ❷ The Number of The Pins 10H : 10 Pin For PLC Connector YK : YOKOGAWA MS : MATSUSHITA MK : MASTER K OM : OMRON FR : FARA CM : CIMON 20H : 20 Pin 24F : 24 Pin 37D : 37 Pin DSUB Socket 37DP : 37 Pin DSUB Plug 40H : 40 Pin Hirose ❸ To The Direction of Pin No.1 of PLC Connector ❹ Connector Y : Y Terminal Z : Open Cable W : Top Side A : Bottom Side CN2 CN3 CC : C/T, C/T Y :Y Terminal Z : Open Cable FU : FUJI 40F : 40 Pin FUJI RR : R/T, R/T CR : C/T, R/T RC : R/T, C/T MS : MATSUSHITA MK : MASTER K FU : FUJI CM : CIMON ☞ C/T : Connector Terminal R/T : Relay Terminal CXT - ❶ ❷ ❸ ❹ ❶ PLC Maker MB : MITSUBISHI NA : NAIS OM : OMRON FR : FARA ❷ The Number of The Pins 10H : 10 Pin 20H : 20 Pin 24F : 24 Pin For PLC Connector ❸ To The Direction of Pin No.1 of PLC Connector ❹ Connector YK : YOKOGAWA 37D : 37 Pin DSUB Socket 37DP : 37 Pin DSUB Plug 40H : 40 Pin Hirose Y : Y Terminal Z : Open Cable W : Top Side A : Bottom Side CN2 CN3 CC : C/T, C/T Y :Y Terminal Z : Open Cable RR : R/T, R/T 40F : 40 Pin FUJI CR : C/T, R/T RC : R/T, C/T ☞ The cable length is basically 1 m, and 0.5 ~ 10 m cables are produced by order. ☞ NPN or PNP must be indicated in the order, for cables other than Mitsubishi products. Ⅲ - 38 Industrial Controls Catalog www.kacon.co.kr Rev. 2/14 Data subject may change without notice. Data Processing General Specification of the Interface Terminal (R/T, C/T) and cables relevant to eac MITSUBISHI Relay Terminal To Be Used For The Output Connector PLC Model ANS Q I/O Point 32 CXT-C40 CXT-MB40H 1 A1SX81(S2) 32 CXT-C40 CXT-MB37D 1 A1SX42(S1,S2) 64 CXT-C40 CXT-MB40H 2 A1SX71 32 32 RXT-N32 Quantity Cable I/O Card A1SX41(S1,S2) A1SY41 Cable Terminal To Be Used For Input and Output Connector Terminal RXT-MB40H 1 Quantity CXT-C40 CXT-MB40H 1 CXT-C40 CXT-MB40H 1 2 A1SY42 64 RXT-N32 RXT-MB40H 2 CXT-C40 CXT-MB40H A1SY81(S2) 32 RXT-P32 RXT-MB37DP 1 CXT-C40 CXT-MB37D 1 A1SY71 32 RXT-N32 RXT-MB40H 1 CXT-C40 CXT-MB40H 1 A1SH42 32(in/out) RXT-N32 RXT-MB40H 1 CXT-C40 CXT-MB40H 1 AX42/MX42 64 CXT-C40 CXT-MB40H 2 AY42/MY42 64 AY42/MY42 32(in/out) CXT-C40 CXT-MB40H 2 CXT-C40 CXT-MB40H QX41 1 32 CXT-C40 CXT-MB40H 1 QX81 32 CXT-C40 CXT-MB37D 1 RXT-N32 RXT-MB40H 1 QX42 64 CXT-C40 CXT-MB40H 2 QY41P 32 RXT-N32 RXT-MB40H 1 CXT-C40 CXT-MB40H 1 QY81P 32 RXT-N32 RXT-MB37DP 1 CXT-C40 CXT-MB37D 1 QY42P 64 RXT-N32 RXT-MB40H 2 CXT-C40 CXT-MB40H 2 LG GLOFA (MASTER-K) Relay Terminal To Be Used For The Output Connector PLC Model GM6 (K200S) GM4 (K300S) GM3 (K1000S) I/O Card I/O Point Cable Quantity 32 CXT-C40 CXT-MK37D 1 G6I-D24B 32 CXT-C40 CXT-MK37D 1 G6Q-TR4A 32 RXT-N32 RXT-MK37D 1 CXT-C40 CXT-MK37D 1 G6Q-TR4B 32 RXT-P32 RXT-MK37D(PNP) 1 CXT-C40 CXT-MK37D 1 G4I-D24A 32 CXT-C40 CXT-MK37D 1 G4I-D24B 32 CXT-C40 CXT-MK37D 1 G4Q-TR4A 32 RXT-N32 RXT-MK37D 1 CXT-C40 CXT-MK37D 1 G4Q-TR4B 32 RXT-P32 RXT-MK37D(PNP) 1 CXT-C40 CXT-MK37D 1 CXT-C40 CXT-MK40FW 1 1 G4I-D28A 64 G3I-D28A 64 Data subject may change without notice. Quantity 64 G4Q-TR8A G3Q-TR8A Cable Terminal To Be Used For Input and Output Connector Terminal G6I-D24A G3Q-TR8B Rev. 2/14 Relay Terminal 64 64 CXT-C40 CXT-MK40FA RXT-N32 RXT-MK40FW 1 CXT-C40 CXT-MK40FW 1 RXT-N32 RXT-MK40FA 1 CXT-C40 CXT-MK40FA 1 CXT-C40 CXT-MK40FW 1 CXT-C40 CXT-MK40FA 1 CXT-C40 CXT-MK40FW 1 1 RXT-N32 RXT-MK40FW 1 RXT-N32 RXT-MK40FA 1 CXT-C40 CXT-MK40FA RXT-P32 RXT-MK40FW 1 CXT-C40 CXT-MK40FW 1 RXT-P32 RXT-MK40FA 1 CXT-C40 CXT-MK40FA 1 www.kacon.co.kr Industrial Controls Catalog Ⅲ - 39 Data Processing A Relay Terminal Interface Terminal Cable RXT, CXT Series General Specification of the Interface Terminal (R/T, C/T) and cables relevant to eac OMRON Relay Terminal To Be Used For The Output Connector PLC Model I/O Card C500-ID114 C500 COM1 CJ1W CS1W C200 Ⅲ - 40 C500H-ID119 I/O Point Relay Terminal 64 64 CQM1-ID112 32 RXT-N32 RXT-OM40FW 1 RXT-N32 RXT-OM40FA 1 CQM1-ID213/ID214 32 CQM1-OD213 32 RXT-N32 CJ1W-ID231/OD231 32 RXT-N32 RXT-OM40FW 1 64 CJ1W-OD261 64 CS1W-ID231/OD231 32 CS1W-ID261 Quantity 64 C500H-OD213 CJ1W-ID261 Cable 64 C200H-MD115 32(in/out) Cable Quantity CXT-C40 CXT-OM40FW 1 CXT-C40 CXT-OM40FA 1 CXT-C40 CXT-OM40FW 1 CXT-C40 CXT-OM40FA CXT-C40 CXT-OM40FW 1 CXT-C40 CXT-OM40FA 1 CXT-C40 CXT-OM40FW 1 CXT-C40 CXT-OM40FW 1 CXT-C40 CXT-OM40FW 1 CXT-C40 CXT-OM40FW 1 CXT-C40 CXT-OM40FW 1 CXT-C40 CXT-OM40FA 1 RXT-N32 RXT-OM40FW 1 CXT-C40 CXT-OM40FW 1 RXT-N32 RXT-OM40FA 1 CXT-C40 CXT-OM40FA 1 RXT-N32 RXT-OM40FW 1 64 CS1W-OD261 Terminal To Be Used For Input and Output Connector Terminal CXT-C40 CXT-OM40FW 1 CXT-C40 CXT-OM40FW 1 CXT-C40 CXT-OM40FA 1 1 CXT-C40 CXT-OM40FW 1 RXT-OM40FA 1 CXT-C40 CXT-OM40FA 1 RXT-OM24F 1 CXT-C20 CXT-OM24H 1 RXT-N32 RXT-OM40FW RXT-N32 RXT-N16 C200H-MD215 32(in/out) RXT-N16 RXT-OM24F 1 CXT-C20 CXT-OM24H 1 C200H-MD501 32(in/out) RXT-N16 RXT-OM24F 1 CXT-C20 CXT-OM40FW 1 C200H-OD219 64 RXT-N32 RXT-OM40FW 1 CXT-C40 CXT-OM40FW 1 RXT-N32 RXT-OM40FA 1 CXT-C40 CXT-OM40FA 1 C200H-ID216 32 CXT-C40 CXT-OM40FW 1 C200H-ID218 32 CXT-C40 CXT-OM40FW 1 C200H-ID111 64 C200H-ID217 64 C200H-ID215 32 C200H-ID501 32 C200H-OD215 32 C200H-OD501 32 Industrial Controls Catalog CXT-C40 CXT-OM40FW 1 CXT-C40 CXT-OM40FA 1 CXT-C40 CXT-OM40FW 1 CXT-C40 CXT-OM40FA 1 CXT-C20 CXT-OM24F 1 CXT-C20 CXT-OM24F 1 CXT-C20 CXT-OM24F 1 CXT-C20 CXT-OM24F 1 RXT-N16 RXT-OM24F 1 CXT-C20 CXT-OM24F 1 RXT-N16 RXT-OM24F 1 CXT-C20 CXT-OM24F 1 RXT-N16 RXT-OM24F 1 CXT-C20 CXT-OM24F 1 RXT-OM24F 1 CXT-C20 CXT-OM24F 1 RXT-N16 www.kacon.co.kr Rev. 2/14 Data subject may change without notice. Data Processing General Specification of the Interface Terminal (R/T, C/T) and cables relevant to eac YOKOGAWA Relay Terminal To Be Used For The Output Connector PLC Model Cable Quantity Terminal To Be Used For Input and Output Connector Terminal I/O Card I/O Point Cable Quantity F3XD32-3F 32 CXT-C40 CXT-YK40F 1 F3XD32-4F 32 CXT-C40 CXT-YK40F 1 F3XD32-5F 32 CXT-C40 CXT-YK40F 1 F3XD32-3N 32 CXT-C40 CXT-YK40F 1 F3XD32-4N 32 CXT-C40 CXT-YK40F 1 F3XD32-5N 32 CXT-C40 CXT-YK40F 1 F3YD32-1A 32 RXT-N32 RXT-YK40F 1 CXT-C40 CXT-YK40F 1 F3YD32-1B 32 RXT-N32 RXT-YK40F 1 CXT-C40 CXT-YK40F 1 F3YD32-1T 32 RXT-N32 RXT-YK40F 1 F3XD64-3F 64 CXT-C40 CXT-YK40F 1 CXT-C40 CXT-YK40F 2 F3XD64-4F 64 CXT-C40 CXT-YK40F 2 F3XD64-3N 64 CXT-C40 CXT-YK40F 2 F3XD64-4N 64 CXT-C40 CXT-YK40F 2 F3YD64-1A 64 RXT-N32 RXT-YK40F 1 CXT-C40 CXT-YK40F 1 F3YD64-1F 64 RXT-N32 RXT-YK40F 1 CXT-C40 CXT-YK40F 1 F3YD64-3F 32(in/out) RXT-N32 RXT-YK40F 1 CXT-C40 CXT-YK40F 1 F3YD64-4F 32(in/out) RXT-N32 RXT-YK40F 1 CXT-C40 CXT-YK40F 1 F3WD64-3N 32(in/out) RXT-N32 RXT-YK40F 1 CXT-C40 CXT-YK40F 1 F3WD64-4N 32(in/out) RXT-N32 RXT-YK40F 1 CXT-C40 CXT-YK40F 1 The Details On The Cables RXT-MB40H RXT-MK37D MIL(HIROSE) FUJITSU D-SUB SOCKET D-SUB PLUG Other model is available at custom order Rev. 2/14 Data subject may change without notice. www.kacon.co.kr Industrial Controls Catalog Ⅲ - 41 Data Processing FM-M3 Relay Terminal Interface I/O Module EGT Series Part Number Description EGT-30 - ❶ ❷ Input ❶ Control Points and Types 1 : 32 Points, Terminal Stand Type 2 : 16 Points, Terminal Stand Type ❷ Input Types * N : NPN Input P : PNP Input 7 : 32 Points, Cable Type (Connector) * It can be used regardless of N or P type when the input signal is a simple contact. EGT-50 - ❶ ❷ ❸ Output ❶ Control Points and Types 1 : 32 Points, Terminal Stand Type 2 : 16 Points, Terminal Stand Type 7 : 32 Points, Cable Type (Connector) ❷ Output Types P: NPN output N: PNP output R: Relay output ❸ Error Processing H : Hold ** F : Load Off *** ** When there is an abnormal signal, the status right before the abnormality is maintained and, once the proper modification is made, Digi-Link is automatically reset. *** In case of a abnormal signal, the outputs are all turned off. and once the abnormality is handled, Digi-Link is automatically reset. General Specification Transmission Speed 5msec, reset / 150m sec Rated Voltage 24VDC±10% Ambient Temperature 0°C ~ +55°C General Ratings All Models Qualified for the CE Marking (EMC directives) Resistance to Noise EMI standard EN61000-6-2 EMI Standard EN61000-6-4 pulse Noise ±2kV (wave length 1us) generated by the noise simulator Normal Input contacts, linear 2-line sensor, NPN, PNP output type device Input Voltage Range 0V ~ Regular Voltage Input Logic Active Low, Active High Input Current 3mA ~ 6mA Input Units Ratings No Contacts ON/OFF With Contacts Current Consumption Output Unit Ratings (Tr) Output Unit Ratings (Relay) Ⅲ - 42 On Measured Voltage Lower Than 7V Off Measured Voltage 15V or Higher On Measured Resistance 5KΩ or Lower Off Measured Voltage 25KΩ or Higher 140mA (all the inputs are on) Output Type NPN, PNP Regular Load Voltage Rated Voltage Maximum Output Current 100mA/point Residue Voltage 0.7V Current Consumption 200mA (with no load, all the outputs are on) Output Type Relay Rated Load Voltage 24VDC, 110VAC, 220VAC Maximum Output Current Relay (2A / point) Residue Voltage OV Current Consumption 200mA (with no load, all the outputs are on) Industrial Controls Catalog www.kacon.co.kr Rev. 2/14 Data subject may change without notice. Data Processing Product Selection Output - 32 Point Unit EGT-501R EGT-501P •The control can be done when the output type is in a relay form, in accordance with the load conditions of DC or AC. •The output type is an NPN Open Collector and supports 100mA/DC per point. •The relays can easily be dismounted, and more compatible with the existing relay board. •The output is compatible with the COM of non-polarity or negative polarity, when connected to a PLC. •The COMs on the relay are grouped by 8 points, so, it is easier to use the loads from different voltages. •It responses to whatever polarity of the COM when connected to the input card of PLC. EGT-507P •The output type is a PNP Open Collector and it supports 100mA/DC per point. •The unit is used in connection with various kinds of input cards of PLC. The installation can be done with ease using the cable. •The output is compatible with the COM of non-polarity or negative polarity, when connected to a PLC. •The Internal output is an NPN Open Collector, and when connected to a PLC, it is used with the Nonpolarized or a positive COM on the PLC’s input card. Input - 32 Point Unit EGT-307N EGT-301N •The device is used in connection with various types of PLC’s output cards. With using the cables, the installation is easier. •The inside structure is the same with the input cards of PLC. So, the installation can be done in the same way as the switch and the sensors attached to the PLC input cards. •The internal input is composed of photo couplers, and it response to the NPN and relay output types of the PLC. •Connect and used the device to the PLC output card when the NPN and the relay outputs are used. Output - 16 Points Unit EGT-502R EGT-502N EGT-502P •The outputs are in a relay arrangement, so it can be controlled in accordance with the DC or AC loads. •The output type is a PNP Open Collector and supports 100mA/ DC per point. •The output type is a NPN Open Collector and supports 100mA/ DC per point. •The COMs of no polarity or negative polarity on the input cards when connected to the PLC can be responded to •The COMs of no polarity or positive polarity on the input cards when connected to the PLC can be responded to. •The relay can easily be dismounted and compatible with the existing relay board. •The COMs of the relay are groups by 8 points to make it possible to use the loads from different voltages. •When connected to the input cards of the PLC, the COMs of any polarity can be responded to. Input - 16 Point Unit EGT-302N •The inside structure is the same with that of a PLC input card. So, the installation works for the switches and the sensors can be done in the same way. •The device can be linked to and used when the output types are of NPN Open Collector or Relay type, when connected to the output card of the PLC. Rev. 2/14 Data subject may change without notice. www.kacon.co.kr Industrial Controls Catalog Ⅲ - 43 Data Processing EGT-501N Interface I/O Module EGT Series Pin Composition Diagram and Inside Wiring Diagram EGT-307□ EGT-507□ Pin NO Signal No Pin NO Signal No Pin NO Signal No Pin NO Signal No Pin NO Signal No Pin NO Signal No Pin NO Signal No Pin NO Signal No 40 A0 39 B0 20 AA 19 BA 40 A0 39 B0 20 AA 19 38 A1 37 B1 18 AB 17 BB 38 A1 37 B1 18 AB 17 BA BB 36 A2 35 B2 16 AC 15 BC 36 A2 35 B2 16 AC 15 BC 34 A3 33 B3 14 AD 13 BD 34 A3 33 B3 14 AD 13 BD 32 A4 31 B4 12 AE 11 BE 32 A4 31 B4 12 AE 11 BE 30 A5 29 B5 10 AF 9 BF 30 A5 29 B5 10 AF 9 BF 28 A6 27 B6 8 NC 7 NC 28 A6 27 B6 8 NC 7 NC 26 A7 25 B7 6 NC 5 NC 26 A7 25 B7 6 NC 5 NC 24 A8 23 B8 4 +24V 3 OV 24 A8 23 B8 4 +24V 3 OV 22 A9 21 B9 2 +24V 1 OV 22 A9 21 B9 2 +24V 1 OV When Using MITSUBISHI PLC 1) For the Input Cards PLC Machine ANS A Q PLC Input Card Point A1SX41 A1SX41-S1 A1SX41-S2 A1SX71 QX41 QX41-S1 QX71 Application Digi-Link Cable Quantity 32Point FCN/PLUG-40P SINK EGT-507P EGT-C100 (1M) 2 A1SX42 A1SX42-S1 A1SX42-S2 AX42 AX42-S1 AX42-S2 QX42 QX42-S1 QX72 64Point FCN/PLUG-40P SINK EGT-507P EGT-C100 2 A1SX81 A1SX81-S2 32Point D-SUB/PLUG-37P SINK EGT-507P EGT-C200 1 QX81 32Point D-SUB/PLUG-37P SOURCE EGT-507N EGT-C300 1 AX82 64Point D-SUB/PLUG-37P SOURCE EGT-507N EGT-C300 2 PLC Input Card Point Application Digi-Link Cable Quantity A1SY41 A1SY71 QY41P QY71 32 points FCN/PLUG-40P SINK EGT-307N EGT-C400 1 A1SY42 A1SY82 QY42P AY42 AY42-S1 AY42-S3 AY72 64 points FCN/PLUG-40P SINK EGT-307N EGT-C400 2 AY42-S4 64 points FCN/PLUG-40P SINK EGT-307N EGT-C400 2 AY82EP 64 points D-SUB/PLUG-37P SOURCE EGT-307P EGT-C500 2 A1SY81 A1ST81EP QY81P 32 points D-SUB/PLUG-37P SOURCE EGT-307P EGT-C500 1 1) For the Output Cards PLC Machine ANS A Q Ⅲ - 44 Industrial Controls Catalog www.kacon.co.kr Rev. 2/14 Data subject may change without notice. Data Processing Using LS Industrial System PLC 1) For the Input Cards PLC Machine K200S K300S K1000S GM6 GM4 GM3 PLC Input Card Point Application Digi-Link Cable Quantity G3I-D28A 64 points FCN/PLUG-40P SINK EGT-507P EGT-C600 2 32 points D-SUB/PLUG-37P SINK EGT-507P EGT-C700 1 G6I-D24B 32 points D-SUB/PLUG-37P SINK EGT-507N EGT-C800 1 PLC Input Card Point Application Digi-Link Cable Quantity G3Q-TR8A 64 points FCN/PLUG-40P SINK EGT-307N EGT-C900 2 G3Q-TR8B 64 points FCN/PLUG-40P SOURCE EGT-307P EGT-C1000 2 G3Q-TR8A 64 points FCN/PLUG-40P SINK EGT-307N Left EGT-C1100 Right EGT-C1000 2 G4Q-TR4A G6Q-TR4A 32 points D-SUB/SOKET-37P SINK EGT-307N EGT-C1200 1 G4Q-TR4B G6Q-TR4B 32 points D-SUB/SOKET-37P SINK EGT-307P EGT-C1300 1 G4I-D28A G4I-D24A G4I-D24C G6I-D24C G4I-D24B 1) For the Output Cards PLC Machine Data Processing K200S K300S K1000S GM6 GM4 GM3 Merits [Before Use] [After Using] For 1 : 1 wiring Using Terminals Using Digi-link ·Input : 64 points ·Output : 32 points ·Input : 64 points ·Output : 32 points ·Input : 64 points ·Output : 32 points ·Amount of labor for pressurizing : 96 points x 4 = 384 ·Amount of labor for pressurizing : 96 points x 2 = 192 ·Amount of labor for pressurizing : 4×3=12 ·Amount of labor for labeling : 96 points x 4 = 384 ·Amount of labor for labeling : 96 points x 2 = 192 ·Amount of labor for labeling : 4×3=12 ·Amount of labor for Wire connecting : 96 points x 4 = 384 ·Amount of labor for Wire connecting : 96 points x 2 = 192 ·Amount of labor for Wire connecting : 6×3=18 ·Amount of labor for the Assembly works for the terminal ·Amount of labor for the Assembly works for the terminal ·Total amount of labor : 42 stand : 96 points x 2 = 192 stand : 96 points×1=96 ☞ Use 2 Line wires Maximum 600M (VCTF 0.75 x 2c) ·Total amount of labor : 1344 ·Total amount of labor : 672 Rev. 2/14 Data subject may change without notice. www.kacon.co.kr Industrial Controls Catalog Ⅲ - 45