Survey
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
HighPROTEC-2 MCDGV4-2 Generator Protection with differential Sales presentation 2015/08/10 PROPRIETARY INFORMATION - © 2015 WOODWARD, INC. PAGE 1 MCDGV4 - Key Benefits Cost savings for field service equipment and commissioning effort Integrated Fault simulation - Faults can be simulated in the device for “dry testing” without external wiring Easy relay configuration achieves high service staff acceptance and minimizes training expenses Change tracking and plausibility check avoids parameter errors Optimized overview by hidden protection modules in planning module Text explanation for all parameter avoids misunderstanding All in one protection functions by an optimized overview reduced risk of changed customer requirements and to order a wrong devices type Full Protection package for Differential Protection, Restricted earth fault, OC, EC, Thermal load, Inrush detection, voltage, frequency… Protection of generator and transformer with one device With logic, up to 80 equations PROPRIETARY INFORMATION - © 2015 WOODWARD, INC. PAGE 2 MCDGV4 - Key Benefits Production and maintenance flexibility Flexible hardware covers a wide range of nominal values (Vn setting for DI, wide range power supply, wide range voltage measuring, 1A/5A in one version) Easy wiring at the rear side, pre wiring possible via terminal kit All terminals are removable, including current measuring terminals PC Tool Smart View for free Page editor to create own pages and single lines Easy connection between PC and Protection device via USB interface Visualization of tripping curves graphically to get visual feedback of settings and protection concept Look and feel over the complete HighPROTEC line -reduced training efforts PROPRIETARY INFORMATION - © 2015 WOODWARD, INC. PAGE 3 Product Ordering code - Easy to select Basic description of Product Generator Differential Protection with voltage, logic and control for 6 switchgear / breaker PROPRIETARY INFORMATION - © 2015 WOODWARD, INC. PAGE 4 Meets Global Standards – for the global market Lloyds Register in preparation PROPRIETARY INFORMATION - © 2015 WOODWARD, INC. PAGE 5 Product Features - All in One Protection functions, one package PROPRIETARY INFORMATION - © 2015 WOODWARD, INC. PAGE 6 Product Features - All in One Protection functions, one package PROPRIETARY INFORMATION - © 2015 WOODWARD, INC. PAGE 7 Product Features - All in One Supervision functions, Control and Logic - one package PROPRIETARY INFORMATION - © 2015 WOODWARD, INC. PAGE 8 Product Features - All in One Optional products to enhance protection functionality PROPRIETARY INFORMATION - © 2015 WOODWARD, INC. PAGE 9 Product Features – All in One ANSI functional overview - one package PROPRIETARY INFORMATION - © 2015 WOODWARD, INC. PAGE 10 Product Features – Flexible Hardware Rear side X1 X2 X3 X4 X5 / X6 X100 X102 X103 X104 Power supply and digital inputs Relay outputs CT measuring board VT measuring board MCA4A = not used MCA4D = add. 6 binary outputs and 8 digital inputs Ethernet Interface RJ45, (IEC, Modbus, Profibus, DNP3) Interface for external Temperature box URTD Communication Interface (IEC, Modbus, Profibus, DNP3) IRIG/ Watchdog Design advantages Making it easier to apply worldwide The flexible hardware minimized commissioning, and ordering failures Wide range power supply 24-270VDC / 48-230VAC Nominal voltages for the digital inputs are per software settable CT measurement always with 1A and 5A VT measurement from 0V up to 800 V AC All terminal blocks are removable, CT Connector with integrated short circuit device Housing based on aluminum extrusion parts PROPRIETARY INFORMATION - © 2015 WOODWARD, INC. PAGE 11 Product Features –Temperature box URTD Design advantages Reduced wiring because no need to wire all sensors to the door Up to 12 temperature measuring points, PT100, Ni100, NI120, Cu Save temperature protection with an easy setting in combination with HighPROTEC devices for motors, transformers and generators Easy connection between protection device and URTD box via fibre optic cable (1m – 25m) PROPRIETARY INFORMATION - © 2015 WOODWARD, INC. PAGE 12 Market overview Protection in medium voltage generator applications Applications in different market areas: Power generation – Protection of Generators Steam turbine market (in combination with ATLAS or 505) Gas turbine market Gas and Oil engine producer / Gen Set packager Power plants CHP PROPRIETARY INFORMATION - © 2015 WOODWARD, INC. PAGE 13 Application Example MCDGV4 The generator Generator protection with a direct connection to a busbar. At the busbar several generators could be connected. The GRID connection is at the primary side of the MV transformer. PROPRIETARY INFORMATION - © 2015 WOODWARD, INC. The generator differential protection offers the possibility to protect the generator and the transformer. The MV busbar connection is at the primary side of the transformer. PAGE 14 Application Example MCDGV4 Power plant with distribution system, application is functional covered by HighPROTEC devices PROPRIETARY INFORMATION - © 2015 WOODWARD, INC. PAGE 15 Application Example MCDGV4 MCDGV4 in combination with 505 PROPRIETARY INFORMATION - © 2015 WOODWARD, INC. PAGE 16 Application - Control for 6 Switchgear/ breakers, design your own page Control function up to 6 switchgears Extended interlocking management Switchgear timing management Switchgear status (display Single Line) PC Tool – Page editor Page editor, easy to design a single line or a measuring page PROPRIETARY INFORMATION - © 2015 WOODWARD, INC. PAGE 17 Application Logic – Highest Flexibility Provides logic editor Up to 80 equitation's Select the gate type Assignment of 4 logic input gates Output gates with/ without timer Latched, Set Reset, Inverter PROPRIETARY INFORMATION - © 2015 WOODWARD, INC. PAGE 18 Commissioning and Maintenance Fault simulation with the integrated V-I generator without additional wiring Force and disarm relays, simulate temperatures… Benefit: Save your Time and Money PROPRIETARY INFORMATION - © 2015 WOODWARD, INC. PAGE 19 Disturbance analyzing Event recorder Up to 300 events with ms time stamp Trend recorder up to 1h Fault recorder for first analyzing Disturbance recorder 32 samples per cycle Up to 10s per record Non volatile, 120s memory Each status event, static or changes, is part of the record Analyze your faults with low efforts PROPRIETARY INFORMATION - © 2015 WOODWARD, INC. PAGE 20 Product support statement HighPROTEC Pricing for HighPROTEC-2 Release 3.0 will be unchanged to the actual pricing Available for sales 01st of October 2015 • Could be ordered now from today The HighPROTEC devices Release 2.x (with blue front plate) • Will get no functional update • List price increase for Basic Products (not options) +20% • Available for sales next two years • Repair and support time minimum 7 years (1 of Oct.) PROPRIETARY INFORMATION - © 2015 WOODWARD, INC. PAGE 21 Any questions, remarks? Thanks for your attention PROPRIETARY INFORMATION - © 2015 WOODWARD, INC. PAGE 22