* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download IO-IIM Input Isolation Modules
Phone connector (audio) wikipedia , lookup
Immunity-aware programming wikipedia , lookup
Power inverter wikipedia , lookup
Solar micro-inverter wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Ground (electricity) wikipedia , lookup
Voltage optimisation wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Control system wikipedia , lookup
Dynamic range compression wikipedia , lookup
Ground loop (electricity) wikipedia , lookup
Pulse-width modulation wikipedia , lookup
Flip-flop (electronics) wikipedia , lookup
Buck converter wikipedia , lookup
Mains electricity wikipedia , lookup
Analog-to-digital converter wikipedia , lookup
Power electronics wikipedia , lookup
Schmitt trigger wikipedia , lookup
Power supply wikipedia , lookup
IO-IIM Date of Issue: 15/11/2012 Issue Number: 5.7 Page 1 of 4 IO-IIM Input Isolation Modules Features: Benefit: Floating voltage outputs Sensor powered from IO-IIM DIN Rail mounting Isolates the output from the supply ground Technical Overview The IO-IIM range are Intended for use with BMS controllers where an input signal requires galvanic isolation from power ground. The IO-IIM provides DC isolation from ground and accepts either a current or voltage input. The modules are powered by 24Vac and provides a 24Vdc supply up to 100mA for the sensor. The output galvanically isolated with respect to the input/supply ground. Tel: +44 (0)1732 861200. - E-mail: [email protected]. - Web: www.sontay.com. © 2012 Sontay Limited. All rights reserved IO-IIM Date of Issue: 15/11/2012 Issue Number: 5.7 Page 2 of 4 Specification: Input signal: IO-IIM-I IO-IIM-V Output signal IO-IIM-I IO-IIM-V Output current Supply Typical current Power supply to sensor Max. sensor current Connections Ambient range Dimensions Country of origin Part Codes: IO-IIM-I 4-20mA, input isolation module 4-20mA 0-10V or 0-5Vdc IO-IIM-V 0-10Vdc 0-10Vdc or 0-5Vdc 20mA max. 24Vac only (+15%, -10%) 80mA + load 24Vdc (±5%) 100mA Rising cage terminals for 0.52.5mm² cable -10 to +50°C (14 to 122°F) 75 x 102 x 65mm (2.95 x 4.02 x 2.56”) UK 0-5V/0-10Vdc, input isolation module . The products referred to in this data sheet meet the requirements of EU Directive 2004/108/EC Tel: +44 (0)1732 861200. - E-mail: [email protected]. - Web: www.sontay.com. © 2012 Sontay Limited. All rights reserved IO-IIM Date of Issue: 15/11/2012 Issue Number: 5.7 Page 3 of 4 Applications & Function: Intended for applications where the BEMS controller can only accept floating inputs and there are problems with sensor grounding. Also useful for situations where a BEMS system is interfacing to other equipment which requires a floating input. If used on the output of a controller which has a floating ground it is essential that the 24Vac supply to the module is also floating. Notes: The IO-IIM-I provides a 24Vdc supply to the sensor but requires a 24Vac supply itself with one side grounded. If the sensor is loop powered, the Sensor Gnd terminal is unused. The IO-IIM-V and IO-IIM-I modules each provide complete electrical isolation from the supply and sensor input to the output. Each comprises an opto-isolator with an integral power supply which powers the electronics and, if required the sensor. A controller or an external power supply provides 24Vac power to the IO-IIM, which provides a 24Vdc regulated supply, at up to 100mA. The output voltage is 0-10Vdc for an IO-IIM-I and either 0-5Vdc or 0-10Vdc for an IO-IIM-V. Installation & Set-up: Antistatic precautions must be observed when handling these modules. The PCB contains circuitry that can be damaged by static discharge. 1. The IO-IIM should only be installed by a competent, suitably trained technician, experienced in installation with hazardous voltages. (>50Vac & <1000Vac or >75Vdc & 1500Vdc) 2. Ensure that all power is disconnected before carrying out any work on the IO-IIM. 3. Maximum cable is 2.5mm², care must be taken not to over tighten terminals. 4. When mounting the IO-IIM care should be taken not to stress the PCB when fitting to the DIN rail. If it is necessary remove the module from the DIN rail, be sure to use a flat bladed screwdriver to release the DIN clips. The IO-IIM-I is factory set so that 4-20mA on the input becomes 0-10Vdc on the output. The IO-IIM-V has two inputs; ÷1 and ÷2, so that if required a 0-10V signal can be converted to a 0-5Vdc signal by wiring it to the ÷2 input. Alternatively, a 0-5Vdc signal can be connected to the ÷1 input to give an isolated 0-5Vdc output. The same applies to a 0-10Vdc signal to give a 0-10Vdc output. . Tel: +44 (0)1732 861200. - E-mail: [email protected]. - Web: www.sontay.com. © 2012 Sontay Limited. All rights reserved IO-IIM Date of Issue: 15/11/2012 Issue Number: 5.7 Page 4 of 4 Connections: Output + Output - OP+ OP- OP+ OP- GND IP/1 IP/2 24VDC Sensor 0v 1 i/p signal 2 i/p signal Sensor 24Vdc GND 24Vac Supply 0v 24Vac GND 4-20mA 24VDC Sensor 0v 4-20mA signal Sensor 24Vdc Supply 0v 24Vac GND 24Vac IO-IIM-V Output + Output - IO-IIM-I Whilst every effort has been made to ensure the accuracy of this specification, Sontay cannot accept responsibility for damage, injury, loss or expense from errors or omissions. In the interest of technical improvement, this specification may be altered without notice. Tel: +44 (0)1732 861200. - E-mail: [email protected]. - Web: www.sontay.com. © 2012 Sontay Limited. All rights reserved