Survey
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Current source wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Opto-isolator wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Buck converter wikipedia , lookup
Stray voltage wikipedia , lookup
Alternating current wikipedia , lookup
Voltage optimisation wikipedia , lookup
Mains electricity wikipedia , lookup
FBC series 300V 60A Automatic Battery Charger ITEMS FBC-30060 Input Power AC220V 50HZ 1Phase or AC220V 3Phase or AC380V 3Phase Charging Voltage DC 300V (max.375V) Charging Current max.60A Charging method Limit Current / Limit Voltage / Absorption / Equalization Recommended Size(Ah) Battery Battery Types Accommodated 300AH ~ 480AH Lead-Acid of Deep cycle, Flooded, VRLA batteries Short circuit protection. Reverse polarity protection. Anti-Arc protection Over temperature protection. Protection Operating Temperature Dimensions ( Lx WxH ) 600mm X 670mm X 1050mm Kgs Weight Ideal uses: -20℃ ~ 50℃ Industry Heavy Duty Useing Features: ◎ ◎ ◎ ◎ Fully controlled by microprocessor. Programmable voltage capability No Power in the output leads until connected to the batteries. Two start modes: * Auto start with thirty minute delay(programmable 30、60、90 or 120 minutes) * Push to start ◎ Automatic Equalization ◎ Anti-Arc protection:Means no sparks are generated when connecting the charger to the battery or outlet. ◎ Low battery voltage start:The charging function will be started when battery is at low voltage. When battery over discharging to low voltage as 1V (for single cell), the microcomputer of this charging apparatus will be able to start to charge. ◎ Protection over the reverse connection of the battery: When the pole of the battery is wrongly connected, the charging machine will be unable to use. 1. Auto detect function:Auto check whether the battery wiring and charging circuit are normal and completely correct,then the microcomputer may start to do the charging. 2. Microcomputer check ( check stopped when battery abnormal ):When battery is breakdown or cell plate is damaged and unable to achieve 80% effective capacity or battery voltage unable to achieve effective saturation voltage within 12 hours,the charging apparatus will auto stop to protect the charging apparatus and battery, besides the indicator will display the battery abnormal. 3. Regulate the charging voltage and current to guarantee steady absorption of the battery:The steady current protects the battery in absorption stage, no temperature raise & no over charging. (The battery temperature will go up after it has just been used due to great amount of discharge) 4. Auto delay turning on the machine to protect battery function: when the charging apparatus is turned on and connected to the battery, the charging apparatus will auto get into delay turning on the apparatus for charging, and auto start the charging after delay time is up to protect the battery. The delay turning on function may protect the battery for natural cool down, and wait until temperature goes down for auto charging so that the battery temperature will not go too high and affect the battery service life. The delay turning on time may be set up on your own from 30–60、90–120 minutes.【The battery temperature will go up after it has just been used due to great amount of discharge, it is not suitable to do charging right away 5. CPU auto pressure increasing system may do the auto increasing at the end of the charging, when the charging achieved about 80% and the current is one-fifth (1/5) less than that of the output total current, then CUP auto pressure increasing system may auto increase the charging current at the end of the charging to help the charging achieve 100%. 6. Even time balance function allow every single pole of the battery achieve evenly saturated voltage and increase the efficiency, the even balance time may set up at 60-120-180-240 minutes respectively. 7. The electricity quantity of the battery displayed with percentage can fully control the charging saturation change. 8. The digital voltage meter displays the voltage allows you to see if the battery voltage is normal. 9. CPU programmable charging function allows one to regulate the charging method according to the requirement of the customers. CHARGING CURVE: