Survey
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
HighPROTEC-2 MRU4-2 Voltage Frequency Relay Sales presentation 2015/08/10 PROPRIETARY INFORMATION - © 2015 WOODWARD, INC. PAGE 1 MRU4 - Key Benefits Cost savings for field service equipment and commissioning effort Integrated Fault simulation - Faults can be simulated in the device for “dry testing” without external wiring Easy relay configuration achieves high service staff acceptance and minimizes training expenses Change tracking and plausibility check avoids parameter errors Optimized overview by hidden protection modules in planning module Text explanation for all parameter avoids misunderstanding All in one protection functions by an optimized overview reduced risk of changed customer requirements and to order a wrong devices type Full Protection package for voltage, frequency, synchro check, ROCOF… Grid coupling and stabilization functions – LVRT With logic, up to 80 equations PROPRIETARY INFORMATION - © 2015 WOODWARD, INC. PAGE 2 MRU4 - Key Benefits Production and maintenance flexibility Flexible hardware covers a wide range of nominal values (Vn setting for DI, wide range power supply, wide range voltage measuring) Easy wiring at the rear side, pre wiring possible via terminal kit All terminals are removable, including current measuring terminals PC Tool Smart View for free Page editor to create own pages and single lines Easy connection between PC and Protection device via USB interface Visualization of tripping curves graphically to get visual feedback of settings and protection concept Look and feel over the complete HighPROTEC line -reduced training efforts PROPRIETARY INFORMATION - © 2015 WOODWARD, INC. PAGE 3 Product Ordering code - Easy to select Basic description of Product Voltage Frequency Relay with logic and control for 1 switchgear / breaker PROPRIETARY INFORMATION - © 2015 WOODWARD, INC. PAGE 4 Meets Global Standards – for the global market Lloyds Register in preparation PROPRIETARY INFORMATION - © 2015 WOODWARD, INC. PAGE 5 Product Features - All in One Protection functions, one package PROPRIETARY INFORMATION - © 2015 WOODWARD, INC. PAGE 6 Product Features - All in One Control, Logic and supervision functions- one package PROPRIETARY INFORMATION - © 2015 WOODWARD, INC. PAGE 7 Product Features - All in One ANSI functional overview - one package PROPRIETARY INFORMATION - © 2015 WOODWARD, INC. PAGE 8 Product Features – Flexible Hardware Rear side X1 X2 X3 X100 X101 X103 Power supply and digital inputs 5 Relay outputs, 1 System Ok output CT measuring board Ethernet Interface RJ45, (IEC, Modbus, Profibus, DNP3) IRIG-B interface Communication Interface (IEC, Modbus, Profibus, DNP3) Design advantages Making it easier to apply worldwide The flexible hardware minimized commissioning, and ordering failures Wide range power supply 24-270VDC / 48-230VAC Nominal voltages for the digital inputs are per software settable VT measurement from 0V up to 800 V AC All terminal blocks are removable, CT Connector with integrated short circuit device Housing based on aluminum extrusion parts PROPRIETARY INFORMATION - © 2015 WOODWARD, INC. PAGE 9 Market overview Protection in medium voltage distribution and generator applications Applications in different market areas: Power plants Infrastructure Main distribution stations Grid Coupling of DER Commercial buildings Distribution substations Industry like Heavy or Process industry Chemical industry PROPRIETARY INFORMATION - © 2015 WOODWARD, INC. PAGE 10 Application Example MRU4 Synchro Check, Bus coupling Bus Coupling Load shedding by underfrequency PROPRIETARY INFORMATION - © 2015 WOODWARD, INC. PAGE 11 Application - Control for 1 Switchgear/ breakers, design your own page Control function up to 1 switchgears Extended interlocking management Switchgear timing management Switchgear status (display Single Line) PC Tool – Page editor Page editor, easy to design a single line or measuring page PROPRIETARY INFORMATION - © 2015 WOODWARD, INC. PAGE 12 Application Logic – Highest Flexibility Provides logic editor Up to 80 equitation's Select the gate type Assignment of 4 logic input gates Output gates with/ without timer Latched, Set Reset, Inverter PROPRIETARY INFORMATION - © 2015 WOODWARD, INC. PAGE 13 Commissioning and Maintenance Fault simulation with the integrated V-I generator without additional wiring Force and disarm relays, simulate temperatures… Benefit: Save your Time and Money PROPRIETARY INFORMATION - © 2015 WOODWARD, INC. PAGE 14 Disturbance analyzing Event recorder Up to 300 events with ms time stamp Trend recorder up to 1h Fault recorder for first analyzing Disturbance recorder 32 samples per cycle Up to 10s per record Non volatile, 120s memory Each status event, static or changes, is part of the record Analyze your faults with low efforts PROPRIETARY INFORMATION - © 2015 WOODWARD, INC. PAGE 15 Product support statement HighPROTEC Pricing for HighPROTEC-2 Release 3.0 will be unchanged to the actual pricing Available for sales 01st of October 2015 • Could be ordered now from today The HighPROTEC devices Release 2.x (with blue front plate) • Will get no functional update • List price increase for Basic Products (not options) +20% • Available for sales next two years • Repair and support time minimum 7 years (1 of Oct.) PROPRIETARY INFORMATION - © 2015 WOODWARD, INC. PAGE 16 Any questions, remarks? Thanks for your attention PROPRIETARY INFORMATION - © 2015 WOODWARD, INC. PAGE 17