Survey
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Current Projects Alan Fisher APE Meeting 2010-08-03 Ongoing Projects Terahertz radiation from the LCLS electrons Measuring short SPEAR bunches by cross correlation of synchrotron light with a Ti:sapphire laser With Jeff Corbett (SSRL) and Aaron Lindenberg Imaging the LHC protons with synchrotron light With Aaron Lindenberg of PULSE With several CERN collaborators Beam-loss monitoring for machine protection at LCLS Catching gas bursts near the LCLS gun Assorted LCLS measurements Terahertz Radiation Electrons pass through beryllium foil downstream of undulator 2-µm foil at 45° to beam, with diamond window below THz radiation extracted from wake of compressed beam Femtosecond pulses with intense fields: Peak electric field expected to be ~3 V/Å Laboratory sources for 1-10 THz are much weaker: < 0.01 V/Å Peak magnetic fields of order 100 T Beam diagnostic: Single-shot characterization of fs bunches User experiments: Switching materials at the level of atoms, optical manipulation and control of structural and electronic properties, measuring the speed of material transformations Later: THz/X-ray pump/probe experiments in the NEH Requires a long THz transport line Calculated Field and Spectrum at Focus Calculation by Henrik Loos for 1 nC and 20 fs Layout of THz Optical Table 800-nm wavelength 20-fs pulses 68-MHz repetition rate 150 mW average power T Laser BS bolometer Half wave plate Bolometer and pyroelectric detector Pyroelectric camera moved through focus Electro-optic sampling Michelson interferometer First samples in focused THz beam BS THz Autocorrelation QWP 2A 2A Pyro detector T,2A iris R Balanced Diodes/Andor Pyro cam. Later: Diagnostics and samples R ZnTe EO sampling flip mirror Focal-spot size R 3T 2A flip mirror 2A Energy per pulse Sample stage /pinhole xyz stage 2A First: THz characterization Delay stage Laser specs T T 2A Motorized filter set Alignment laser e− Putting the First Optics on the Table Restricted, Parasitic, and Full-Time Use Both electrons and x rays hit the foil Negligible loss for photons > 2 keV: parasitic use possible Can’t insert foil when users want soft x rays Perhaps…bump electrons away from x rays at foil Electrons pass through foil, and then return to center of beampipe before bending down to the dump Let x rays miss the foil by skirting its edge or by going through a hole Foil could be used at all times What bump amplitude can we make? Can we cut a hole or support a free edge in a Be foil? Thickness limited to 5 µm by Radiation Physics LHC Synchrotron-Light Monitors Two applications: BSRT: Imaging telescope, for transverse beam profiles BSRA: Abort-gap monitor, to verify that the gap is empty Two particle types: Particles passing through the abort kickers during their rise get a partial kick and might quench a superconducting magnet. Protons and lead ions Three light sources: Undulator radiation at injection (0.45 to 1.2 TeV) Dipole edge radiation at intermediate energy (1.2 to 3 TeV) Central dipole radiation at collision energy (3 to 7 TeV) Spectrum and focus change during ramp Layout: Emission and Extraction Cryostat 70 m 194 mm To arc To RF cavities and IP4 1.6 mrad 420 mm D4 10 m D3 Extracted light sent to an optical table below the beamline U 560 mm 26 m 937 mm Optical Table Extraction mirror Beam Table Alignment laser Calibration light and target Shielding PMT and 15% splitter for abort gap F1 = 4 m F2 = 0.75 m Intermediate image Cameras Slit Focus trombone Table Coordinates [mm] Telescope for Beam 1 Door to RF cavities Beam 1 Undulator and dipole Beam 2 Optical Table Beam-1 Extraction mirror (covered to hunt for light leak) LHC Beams at Injection (450 GeV) Beam 1 Beam 2 Horizontal 1.3 mm 1.2 mm Vertical 0.9 mm 1.7 mm Light from undulator. No filters. Open slit. LHC Beams at 3.5 TeV Beam 1 Beam 2 Horizontal 0.68 mm 0.70 mm Vertical 0.56 mm 1.05 mm Light from D3 dipole. Blue filter. Narrow slit. Calibrating the Abort-Gap Monitor Inject a “pilot” bunch Charge measured by bunchcharge and DC-current electronics Attenuate light by ratio bunch charge / quench threshold Move BSRA gate to include the pilot bunch Find PMT counts per proton (adjusted for attenuation) as a function of PMT voltage and beam energy Turn RF off (coast) for 5 minutes to observe a small, nearly uniform fill of the gap Last bunch in fill First bunch in fill Pilot bunch Abort gap After coasting briefly, bunch spreads out Useful to test gap cleaning… Time [100-ns bins] Test of Abort-Gap Cleaning, December 2009 Abort gap (3 µs) Beam dumped Time (s) Excitation had ringing on the trailing edge (improved in January) Cleaning excites beam at transverse tune. Applied to a 1-µs region: immediate effect. Charge drifting into gap RF off: coasting bunch in bucket just after gap Position in fill pattern (100-ns bins) Gas Bursts in the LCLS Injector Gas burst near gun can lower photocathode’s QE Archiver records pressures at 1 Hz: too low to track the source Beam-synchronous multichannel digitizer (120 Hz) records all pressures in a long circular buffer. Buffer saved automatically after each burst One culprit found: “Guardian” software that halted beam by shutting off low-level RF drive to first linac section (L0A) Pressure burst when Guardian is reset and L0A restarts Gas Burst from L0A Restart Pressure RF Amplitude