Modbus Interface FOR USE WITH XLS50 AND XLS60 PANELS SPECIFICATION DATA FEATURES Compatible with XLS50 and XLS60 intelligent fire alarm panels Connects to the Peripheral Bus (RS485) PI-MBUS-300 Rev. E compliant Poly-carbonate IP67 rated enclosure Three general system status LEDs Silence and Reset "Access Enable" key-switch (Full Repeater only) Requires external power supply DESCRIPTION The Modbus Interface is a compact remote I/O device for the XLS50 and XLS60 intelligent fire alarm systems. This unit, along with other remote I/O devices and the external printer provide a complete range of peripheral devices to further enhance the functionality and expandability of the XLS50/60 systems. The Modbus interface unit allows panel status monitoring by a Modbus control system (i.e. PC Graphic Centrals such as XSM or EBI). Information on the states of panel inputs and outputs, peripherals and the general operating condition of the panel can be interrogated/monitored by the control system. The fire alarm panel can also be remotely "Silenced" or "Reset" from the Modbus control system via the Modbus interface. The Modbus interface is connected to the XLS50/60 panel via the RS485 peripheral port (Port D). An RS485 (or Hi-485) communication card must be fitted in the XLS50 or XLS60 fire alarm panel for that purpose. power supply output on the XLS50/60 panel or any other suitable DC supply of suitable voltage and current rating listed for Fire Protection use. An on-board switch mode power supply (SMPS) isolates the power input from all communication circuitry. The RS485 peripheral address is set via an on-board DIP switch and other peripherals can be daisy chained together on the same line. Up to a maximum of 31 peripheral devices can be connected a peripheral bus. However, only one Modbus interface can be connected to any XLS50 or XLS60 panel. The interface consists of a circuit board housed in a polycarbonate IP67 rated enclosure. Pre-pressed knock-outs on the sides of the enclosure allow cable entry glands to be fitted for power and communication lines wiring. The Modbus interface is fully supervised by the fire alarm control panel and in case of a communication failure, the FACP will indicate a communication failure with the interface/Modbus control system. The Modbus Interface requires an 18V to 28 Vdc external power supply to operate. This may be taken from the auxiliary XLS60/MBUS 12199R0-OB XLS50/60 MODBUS INTERFACE Addressing: Eight way DIP switch defines both the interface's fire alarm panel peripheral address and its Modbus slave address. Valid peripheral address range: 1 to 126 SPECIFICATIONS Operating Voltage: 21.5 to 25.5Vdc (+10%, -15%) LED Indicators: LED 1: Blinks at 1 Hz when the unit is powered and operational LED 2: Indicates Modbus data is currently being received on the RS232 port which is addressed to the unit LED 3: Indicates panel data is currently being received on the RS485 port which is addressed to the unit Current Consumption (typical at 24Vdc): 100mA Environmental Limits: Operating temperature: 0° to 49° C Humidity: 93% non-condensing Dimensions: Enclosure: Width: Height: Depth: Card: Width: Height: Depth: 255 mm 175 mm 75 mm Modbus Communication Settings: Mode: RTU Baud rate: 9600 Data bits: 8 Framing: 1 start bit, 1 stop bit Parity: None Physical Interface: RS232 160 mm 100 mm 32 mm Weight: 1.1 kg Modbus Address Range: 08011-08012: Panel Silence and Reset Installation: Four fixing holes in the back of the plastic enclosure provide easy mounting for the units. A recess mount bezel is also available. Five 20mm knock-outs provided in top and bottom of the enclosure for cable entry. Terminals: Screw terminals Maximum cable cross sectional area 2.5 mm2. (removable block) Discrete Inputs: 12002-13000: 13002-13127: Sensor Loops 1 to 5 Peripheral Devices Input Registers: 32002-33000: 38001: Sensor Loops 1 to 5 Panel Status Approvals: CE Models: Wiring: Maximum Peripheral Bus Length: 1,200m 150 Ohm End-of-Line resitors required at both ends of the RS485 circuit XLS60/MBUS Modbus Interface Other Accessories: 795-004 795-038-001 Recommended Cable: Belden 8760 or equivalent twisted shielded pair RS485 Communication Module Hi-485 High Integrity Module Comfort from Experience Home and Building Control Home & Building Control European Centre of Excellence Honeywell Inc. Honeywell Plaza P.O. Box 524 Minneapolis MN 55408-0524 Honeywell GmbH Honeywellstrasse 63477 Maintal 1 Germany Fire Solutions Lovelace Road, Southern Industrial Area Bracknell, Berkshire, RG12 8WD United Kingdom XLS60/MBUS 12199R0-OB 2