FTIR SPECTROSCOPY REFERENCE GUIDE INTRODUCTION Infrared spectroscopy is the study of the interactions between infrared electromagnetic energy and matter. The technique of infrared spectroscopy measures the vibrations of molecules, allowing for qualitative and quantitative measurements of samples. A Fourier transform infrared (FTIR) spectrometer is an ideal tool for the identification of unknown organic and inorganic samples whether they exist in the form of a gas, liquid or a solid. SPECTRAL RANGE COVERAGE CARY 600 SERIES SPECTROMETER OPTICS Spectral range coverage for common sources, beamsplitters, and detectors. The combination of these components generate a spectrometer’s working scan range. Sources Detectors Wavenumbers (cm-1) Wavenumbers (cm-1) 50,000 Reference laser 40,000 20,000 10,000 5,000 0 65,000 60,000 50,000 Deuterium 53,000 – 12,000 40,000 30,000 20,000 Radiation in the infrared region is commonly referred to in terms of a unit called a wavenumber (ν), rather than wavelength (λ). Wavenumbers are expressed as reciprocal centimeters (cm-1) and are the preferred unit as they are directly proportional to energy. A higher wavenumber corresponds to a higher energy. Beamsplitter storage Wavenumbers (cm-1) Ceramic 9,000 – 29 50,000 40,000 Mercury Arc 600 – 10 Wavenumbers (cm-1) 30,000 20,000 10,000 5,000 0 10,000 7,500 5,000 UV-Vis Quartz 53,000 – 4,000 2,500 DLaTGS 18,000 – 150 Far-IR DLaTGS 700 – 20 Potassium Bromide 11,000 – 375 Convert a wavenumber (ν) to Energy (E) by multiplying it by the speed of light (c, in centimeters per second) and Planck's constant (h): 0 Far-IR detectors Calcium Fluoride 18,000 – 1,200 Detector 1,250 MCT* 12,000 – 450 Near-IR Quartz 20,000 – 2,800 1 λ (cm) 10,000 5,000 0 Mid-IR detectors Convert a wavenumber (ν) to a wavelength (λ) by using the following formula: 20,000 Lead Selenide 16,000 – 2,000 Wavenumbers (cm-1) 40,000 30,000 Silicon 18,000 – 8,600 Beamsplitters 50,000 0 Silicon 18,000 – 8,600 Tungsten-Halogen 25,000 – 2,100 Interferometer Infrared source 10,000 R446 Photomultiplier Tube 54,000 – 11,500 Xenon 40,000 – 10,000 ELECTROMAGNETIC SPECTRUM ν (cm-1) = 30,000 *Multiple MCT detectors (narrow, mid & wide band) are available. Cesium Iodide 6,000 – 225 Mylar (6-125 µm) 700 – 10 E (J) = h (J.s) x c (cm.s-1) x ν (cm-1) 4000 Sample compartment Radio Microwave Far-IR Mid-IR Low Near-IR Wavenumber (ν) Visible High UV Low X-Rays Energy Gamma High THE COMPLETE SOLUTION 400 (cm-1) Short Wavelength (λ) Long A portion of the electromagnetic spectrum showing the relationship of the infrared region to other types of radiation (not shown to scale). The relationship between energy, wavenumber, and wavelength is also highlighted. COLLECTING AN FTIR SPECTRUM There are three quick, simple steps involved in obtaining a spectrum of a sample: INTERPRETING SPECTRA Bond C–H Type of Vibration Alkane (stretch) –CH3 (bend) –CH2– (bend) Alkene (stretch) (out-of-plane bend) Aromatic (stretch) (out-of-plane bend) Alkyne (stretch) Aldehyde Wavenumber Range (cm-1) 3000 – 2850 1450 & 1375 1465 3100 – 3000 1000 – 650 3150 – 3050 900 – 600 ~ 3300 2900 – 2700 Bond C–O Type of Vibration Alcohols, esters, ethers, carboxylic acid, anhydrides O–H Alcohols, phenols Free H-Bonded Carboxylic acids Alkene Aromatic 1680 – 1600 1600 & 1475 C–N Amines 1350 – 1000 C^C Alkyne 2250 – 2100 C=N Imines & oximes 1690 – 1640 C=O Aldehyde Ketone Carboxylic acid Ester Amide Anhydride 1740 – 1720 1725 – 1705 1725 – 1700 1750 – 1730 1680 – 1630 1810 & 1760 C^N Nitriles 2260 – 2240 N=O Nitro (R–NO2) 1550 & 1350 S–H Mercaptans 2550 C–X Halides Fluoride Chloride Bromide, iodide 1400 – 1000 785 – 540 < 650 STEP 1 Record a spectrum with no sample present. (Known as a ‘background’.) STEP 2 Insert the sample into the spectrometer. STEP 3 Record a second spectrum and interpret the data. The key collection parameters are: • The number of scans (background and sample) • The scan range • The spectral resolution. In general increasing the number of scans that are co-added improves the signal-to-noise ratio of the spectrum and can assist in the analysis of weakly absorbing samples. The spectral resolution is user-defined and helps to distinguish closely spaced absorption peaks, and is expressed in wavenumbers. The simplified correlation table on the right allows users to extract structural information from IR spectra. Computer-based search programs are also available for assisting in compound identification. C=C N–H Wavenumber Range (cm-1) 1300 – 1000 3650 – 3600 3400 – 3200 3400 – 2400 Primary & secondary amines & amides (stretch) 3500 – 3100 (bend) 1640 – 1550 Several different accessories facilitate sample preparation and spectral acquisition, including: • Fiber Optic Probes • Attenuated Total Reflectance (ATR) • PM-IRRAS • Diffuse Reflectance • Photoacoustic Spectroscopy • Specular Reflectance • TGA-FTIR • Grazing Angle Reflectance • GC-FTIR • Microscopy and Chemical Imaging • GPC-FTIR • ATR Chemical Imaging (Micro and Macro) A HISTORY OF COMMERCIAL 'FIRSTS' First commercial FTIR spectrometer First FTIR microscope First dynamicallyaligned step-scan interferometer First rapidscanning FPA chemical imaging Cary 600 series FTIR spectrometers and microscopes 1969 1982 1992 2001 2008 1971 1991 1997 2004 2010 First use of an MCT detector in an FTIR First infinitycorrected FTIR microscope First Mid-IR FPA detector system for chemical imaging Varian, Inc. acquired Digilab Varian, Inc. acquired by Agilent This information is subject to change without notice. © Agilent Technologies, Inc. 2013 Published in Australia, Feburary 1, 2013 K8000-90009 *K8000-90009* *K8000-90009*