Survey
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Instruction Manual Full Automatic Digital Wrist Blood Pressure Monitor Model: HPL-100/HPL-100A Contents Introduction………………………………………………………………………………………3 Warning Signs/Safety Statements……………………………………………………………… 3 Health and Blood Pressure Values……………………………………………………………… 4 What is Blood Pressure …………………………………………………………………………4 Important Information …………………………………………………………………………..6 Precautions ………………………………………………………………………………………6 Contraindications ………………………………………………………………………………..7 Warning ………………………………………………………………………………………….8 Suggestions before Measuring Blood Pressure …………………………………………………8 Device Descriptions ……………………………………………………………………………..9 Description of Control Buttons …………………………………………………………………10 Description of LCD Display Symbols ………………………………………………………….10 Installing/Replacing Batteries …………………………………………………………………..11 Program Date and Time (only for HPL-100) …………………………………………………...12 How to Apply the wrist Cuff ……………………………………………………………………13 Correct Measurement Position ………………………………………………………………….14 How to Take A Measurement ……………………………………………………………………15 How to Use the Memory Features (for HPL-100) ………………………………………………16 How to Erase All the Memories (for HPL-100) …………………………………………………17 Maintenance ……………………………………………………………………………………..18 Error Message and Troubleshooting …………………………………………………………….19 Specifications ……………………………………………………………………………………23 Warranty Information ……………………………………………………………………………24 Personal Blood Pressure’s Record ………………………………………………………………25 Introduction Thank you for purchasing the HPL-100/HPL-100A Full Automatic Wrist Blood Pressure Monitor. Please be sure to read this Instruction Manual thoroughly before using the Blood Pressure Monitor for your safe use. For specific information on your own blood pressure , CONTACRT YOUR PHYSICIAN. Measures Blood Pressure & Pulse from the Wrist. Fuzzy logic measurement system. Completely automatic inflation and deflation to provide home blood pressure monitoring convenience. Saves up to 60 memories with Date/Time display(for HPL-100). Easy to wrap wrist cuff suitable for wrist sizes from 5 1/4” to 7 3/4” (135-195mm). Power-saving feature of automatic turn-off for 3 minutes. Low Battery and intelligent error detection. Portable and travels almost anywhere operating on two “AAA” alkaline batteries. Recall and Scan Functions. High Accuracy. Warning Sings & Safety Statements ATTENTION!! Read user’s manual before use. Type be applied part. Health and Blood Pressure Values Blood pressure of the human body increases naturally and dramatically from middle age afterward. This symptom is due to the continuing aging of the blood vessel. Further causes due to obesity, lack of exercise, cholesterol (LDL) adhered to the blood vessels will let the vessel lose their elasticity. With a higher blood pressure, hardening of the arteries will accelerate, and the body becomes more susceptible to apoplexy and coronary infraction. This is the reason we need to know the routine blood pressure trend in order to see whether our body condition is healthy or not. The blood pressure fluctuates constantly throughout our daily life and is an essential element in our daily health management. What is Blood Pressure Blood is pumped to artery by the beat (contraction and expansion) of a pump called the heart. The pressure of the pumped-out blood is called the “blood pressure “. Blood pressure heaves with each beat of the heart. The raised pressure when the heart contract is called the “systolic blood pressure” and the lowered pressure when the heart expands is called the “diastolic pressure”. Blood pressure is typically low in the morning and increases from the afternoon to the evening. It is lower in the summer and higher in the winter. The blood pressure naturally varies from time to time through out the day. Many factors that may cause the blood pressure to fluctuate: Breathing, Exercise, Mental stress, Smoking, Eating, Concern, Environmental and/or temperature change, the Time of day, Urination and bowel movement, Conversation, Taking bath, Drinking alcohol, Medicament and Physical activity, etc. Variations in Blood Pressure: The variations in blood pressure over a whole day with measurement taken every five minutes as shown below. Classification of Blood Pressure by the WHO: The World Health Organization (WHO) and the Inter-national Society of Hypertension (ISH) developed the Blood Pressure Classification shown as below. Important Information Blood pressure values measured at home tend to be lower than those measured in the hospital. This is caused by the fact that you are nervous when you have your blood pressure measured in the hospital, but you feel relaxed at home. It is important to know your stable normal blood pressure measured at home. It is recommend that persons has one of the diseases as heart troubles, kidney trouble, hyper-tension, diabetes, arteriosclerosis or frustration problem of blood vessel, please consult your physician before and during using the blood pressure accurately reflects your actual blood pressure. Blood pressure fluctuates even by 30 to 50 mmHg depending on whether you are nervous or relaxed, exercise or the environment (temperature or mental state) without being noticed. The device may show some reading error in the presence of common arrhythmia such as arterial or ventricular premature beats or arterial fibrillation. Precautions This unit will not serve as a cure of any symptoms of your heart or disease. The measuring data is only for reference. Always consult your physician if any abnormal measuring results happen. Always follow the operation procedures described in the manual when you expect to measure your correct blood pressure. Be sure to store well this manual for future reference. Diseases such as diabetes and hyper lipide accelerate hardening of the arteries. If such conditions continue, there is an increased danger of apoplexy and coronary infarction, arterial stenosis and disorder in peripheral blood circulation. In such cases, there will be a large difference between blood pressure values taken at the wrist and upper arm. (Since even healthy persons may show a difference of 20 mmHg if the conditions of the measurement status are not suitable. Do not rely on the self-diagnosis, and always follow the advice of a physician.) Physiological conditions may have varying degrees of effect, but generally blood pressure values at the wrist and upper arm should display the same pattern of change. Consequently, it is possible to monitor trends in change by measuring blood pressure at the wrist. Contraindications Do not use the device with infants and persons, who cannot communicate, which may lead to serious accidents. Do not use the device for purposes other than measuring blood pressure. Do not use mobile phone or microwave oven near the device, which may lead to reading error. Do not try to disassemble or modify the unit or wrist cuff, which may lead to permanent reading error. Do not start the air pressure when the wrist cuff is not wrapped around the wrist. Do not drop this unit and avoid the unit from strong impact. Warning If the event of the cuff pumping up and not stopping, please open the cuff at once. Do not measure repeatedly for a long period of time. This device is not supposed to be used if your wrist has any wound or injury. If locks connectors are used in the construction of tubing, there is a possibility that they might be inadvertently connected to intra-vascular fluid systems, which case may allow air to be bumped into a blood vessel. Take batteries out of the housing if the unit is not to be used for a long time. Do not use different type, date or brand-name batteries, and this may lead to an incorrect reading. Leaving the batteries in the blood pressure monitor for a long period and not using the device may damage the main unit. Be careful the observing points which listed in the Installing/Replacing Batteries. The device might not meet its performance specification if stored or used outside the specified temperature and humidity ranges. Operating conditions: 10℃~40℃,40%~85% R.H. Conditions for storage: -20℃~50℃,15%~90% R.H. Suggestions before Measuring Blood Pressure 1. Please sit or lie down for at least 5-10 minutes before taking a measurement. 2. Avoid eating, smoking exercising, bathing and drinking (alcohol/caffeine/or tea) for at least 20-30 minutes before taking a measurement. 3. Be sure the wrist cuff is at the same level as your heart. 4. Stress raises blood pressure. Keep calms and relax yourself during a measurement. 5. Avoid talking during a measurement. 6. Avoid urination or bowel movement for several minutes before taking a measurement. 7. Wait 2-3 minutes before taking another blood pressure measurements. 8. Keep the records for your physician as reference. Reminded that one measurement does not provide you with real blood pressure value, only long-term records will reveal the long-tem trend of your blood pressure. Try to measure your blood pressure at the same time each day for consistency. Dev4ice Descriptions POWER: To turn on or turn off the unit. START: To start to inflate the cuff and measure the Blood Pressure and Pulse. TIME: To program and confirm the digit of the Date/Time. MEMO/▲:To review the measured record(s) by manual. To select the digit of the Date/Time. SCAN/ : To review all previously measured record(s) from memory list automatically. To select the digit of the Date/Time. Description of LCD Display Symbols Installing/Replacing Batteries Be sure the unit turns off before installing/replacing batteries, or the memories & Date/Time setting will be lost. If the batteries are removed for more than 30 seconds, the memories of the unit and the setting of Date/Time will be lost. Then, you must reset the Date/Time. Installing/Replacing Batteries 1. Slide the battery compartment in the direction of the arrow to remove it. 2. Place the batteries (two AAA Alkaline batteries) in the compartment as indicated by the polarity symbols (+ and -) marked inside. All the display symbols appear for 3 seconds and then return to standby mode. 3. Replace the battery compartment cover. Note: When (low Battery indicator) appears on the display, the batteries are week. Change the batteries as soon as possible, or it may not be able to take any measurement. And, the memories and the Date/Time setting of the unit may be lost. Warning: a. Be sure to follow the instruction above to install/replace the batteries. b. We recommend you to use the ALKALINE batteries for the best performance and the longest life. c. Use only the fresh batteries of the required size and the recommended type. Do not use old and new batteries together. d. Remove the batteries if not to use the blood pressure monitor for an extended period (i.e.,3 months). The batteries can leak chemicals that can destroy electronic parts. e. Immediately replace run-down batteries with mew ones. f. Check the batteries periodically and replace it if necessary. Program Date and Time(only for HPL-100) Make sure you have turned off the unit before you program the Date and Time. 1. Press and hold TIME button for 5 seconds until the display shows 2003 and starts to flash. 2. Press MEMO/▲ button or SCAN/ button to set the number representing the Year. (You can press and hold MEMO/▲ or SCAN/ buttons for about 2 seconds, the number of the Year will be displayed in the faster-speed.) 3. Press TIME button to confirm the Year setting. The number representing the Date will flash. 4. In the same manner, set the Month, Date, Hour and Minute. Note: After replacing batteries, always confirm the time first, and then use the blood pressure monitor. If the batteries are removed for more than 30 seconds, you must reset the Date/Time. How to apply the Wrist Cuff 1. Hold your left arm in front of you with your palm facing up. Apply the wrist cuff so that the monitor is on the inside side of the wrist with the display in easy view. 2. As shown in the below figure ,cover the wrist cuff by leaving a space of 1/4”~1/2” between the edge of the wrist cuff and the border of arm and the palm of a hand. 3. Hold the bottom part of the wrist cuff and wrap the cuff comfortably around your wrist. The top and bottom edges of the cuff should be tightened evenly around your wrist. (Do not pull strongly on the cuff. Do not make the wrist cuff too tight.) 4. When the cuff is positioned correctly, secure it in place by pressing the pile material firmly against the hook material. Correct Measurement Position In order to read the accurate value, please sit or lie down to measure. Rest your left arm on the table and use the storage, a cushion or pillow as bolster. With left palm face up and keep the cuff at the same level as your heat. Higher or deeper position will give deviations from the true value. (If the wrist cuff is lower than the level of the heart, blood pressure will be measured higher.) Measurement while sitting down: a. Place your elbow on a table or other object (such as your storage case). b. Make sure the wrist cuff is at the same level as your heart. (It is extremely important for the measure values.) c. Relax your hand with the palm facing up. d. After taking deep breaths for several times before measurement, take a natural breath, and then relax your body. How to Take A Measurement Please read and follow directions in “Suggestions before Measuring Blood Pressure” and “How to Apply the Wrist Cuff” before taking a measurement. 1. Press POWER button to turn on the unit. All the display symbols appear for a moment and the number 0 flashing. This is the initial testing. Then, the number 0 will stop flashing and beeps. 2. After the beeps, press START button to take a measurement. (If the unit has been turned on, press START button to take a measurement directly.) *The cuff automatically inflates to approximately 170mmHg. (approximate 50mmHg higher than the average systolic blood pressure reading). The symbol will appear during inflates. 3. When the cuff reaches your correct inflation level, it begins to deflate automatically. As the cuff deflates, decreasing numbers appear on the display. The Heart Symbol flashes with the beeps at the onset of oscillation signals. *Suppose that the blood pressure monitor determines that a higher-pressure value is required during deflation of the measurement, it will momentarily stop deflation and automatically increase the pressure value to the max.280 mmHg. 4. The monitor exhausts the residual air when the measurement is completed. The Heart Symbol stops flashing and your Blood Pressure and Pulse appear on the display. After taking the measurement, the latest measured readings will always be displayed before the power is auto turned off (3 minutes). Note: Wait 2-3 minutes between successive measurements. Waiting allows the engorged blood vessels to return to normal status. You may require more rest time between measurements depending on the your individual physiological conditions. How to Use the Memory Features (for HPL-100) The measured and displayed Blood pressure and Pulse readings are automatically stored in the memory. The blood pressure monitor can store the most recent 60 measurements. If more than 60 measurements have been taken, the earliest measurement will be erased and replaced by the most recent measurement. 1. Recall/Review the previously measurements: Press MEMO/▲ button in either power-on or power-off modes to recall/review the latest measurements to the earliest. If there is any measurements stored in the memory, the latest measurement (M 01) appears when you press MEMO/▲ button. M 01 indicates the latest measure-ment. The Systolic blood pressure. Diastolic blood pressures, Pulse, and Date/Time of measurement will be displayed. Press MEMO/▲ button repeatedly to review the other measurements. The measurement values will be displayed as M 02, M 03, M 04,… etc. 2. Scan all the previously measurements continuously: Press SCAN/ in either power-on or power-off modes, the unit will display all measurements at a speed one second each from the latest measurements to the earliest. How to Erase All the Memories (for HPL-100) Make sure you have turned off the unit before you erase ALL the memories. Press and hold MEMO/▲ and START buttons for 3 seconds until the 0 ALL signs appears. All the memories have been erased already. Maintenance Storage 1. Always use the storage box provided with the device to transport or store the unit. 2. If you are not to use the device for an extended period, remove the batteries for storage. 3. Do not store the device under direct sunlight, high-temperature, humid, dusty, or corrosive environment. 4. Do not stretch, bend or tug on the wrist cuff. 5. Do not immerse the unit in the water. Cleaning 1. Do not use an alcoholic-base, benzene, gasoline or solvent agent to clean the device. 2. Wipe with a moistened cloth with tap water or a mild cleaning agent ant then dry the device with a soft and dry cloth. 3. The dirt on the cuff can be cleaned by the moistened cloth and soap. 4. 5. 6. Do not flush the device and cuff with much water. Do not bend the cuff or sleeve and wrap the sleeve to the inside-out surface. Do not dismantle the device or disconnect the cuff with mains or try to repair by yourself. If any problem happens, refer to the distributor. 7. Do not operate the device under the severe environment of extreme temperature or humidity, or direct sunshine. 8. Do not shock the mains violently. Error Message & Troubleshooting The unit is manufactured through the complete quality assurance system. If the measurement is not made correctly, the following error will be displayed. Measure your blood pressure again correctly. If a trouble occurs while you are using the blood pressure monitor, check the attached Troubleshooting first. If you can not measure your blood pressure correctly even after taking the following countermeasures, the monitor may be have trouble. Please send the unit to the distributor for repair. Do not dismantle the monitor by yourself. Your product HPL-100/HPL-100A, Blood Pressure Monitor, are guaranteed to be free of defects in workmanship and materials under normal use for a period of ONE year from the date of purchase. For repair under guarantee our Authorized Service Agent must be advised of the fault within the period of the guarantee. This guarantee covers parts and labor only under normal operations, any transportation fee, freight fee, incurred is the owner’s responsibility. Any defect resulting from natural causes, e.g., flood , hurricane etc., is not within this guarantee. This guaranty does not cover damage incurred by: use of the product NOT in accordance with the instructions, accidental damage, or being tampered with or serviced by unauthorized Service Agents. Monitor subjected to misuse, abuse, and neglect of these manual content, non-instructional purposes; unauthorized repair or modifications will be excluded from this warranty. This guarantee specifically excludes expendables and consumables, for example batteries. All warranty claims must be the distributor for the sale of the device. The content of this warranty is subject to change without further notice.