Survey
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Internet protocol suite wikipedia , lookup
Deep packet inspection wikipedia , lookup
Distributed firewall wikipedia , lookup
Recursive InterNetwork Architecture (RINA) wikipedia , lookup
Computer network wikipedia , lookup
Piggybacking (Internet access) wikipedia , lookup
Wake-on-LAN wikipedia , lookup
Airborne Networking wikipedia , lookup
Network tap wikipedia , lookup
WEBPOWER Stand-alone & Embedded POWERFUL TECHNOLOGY Scope of training 1. General Network information 2. WebPower Configuration 3. WebPower Functionality 4. WebPower hardware details POWERFUL TECHNOLOGY 1. General Network overview Internet/ Wide Area Network Computer General network info POWERFUL TECHNOLOGY Ethernet Network and TCP/IP Computer Computer Computer Computer Internet Hub Hub Computer Computer Computer Computer Local NetWork Local NetWork General network info POWERFUL TECHNOLOGY Ethernet Network and TCP/IP WebPower IP Address 172 Network Subnet Mask Resulting Subnet Address Network Subnet 16 4 244 255 255 255 0 172 16 4 x 172 16 4 x OK ! WebPower IP Address 172 Network Subnet Mask 17 4 244 255 255 255 0 Resulting Subnet Address 172 17 4 x Network Subnet 172 16 4 x Incorrect ! General network info POWERFUL TECHNOLOGY Ethernet Network and TCP/IP Higher-Layer Protocols and Their Applications • File Transfer Protocol (FTP) — Moves files between devices • Simple Network-Management Protocol (SNMP) — Primarily reports errors and sets values • Telnet — Serves as a terminal emulation protocol • Simple Mail Transfer Protocol (SMTP) — Provides electronic mail services from a client towards a mail server • Post Office Protocol (POP) — a protocol used to retrieve e-mail from a mail server. • Hypertext Documents(WEB) — Websurfing General network info POWERFUL TECHNOLOGY Ethernet Network and TCP/IP Monitoring Telnet Configuration HTTP MAIL (SMTP) Alarms FTP Tunneling SNMP TCP (Transfer Control Protocol) UDP (User Datagram Protocol) Reliable Connection based protocol ”Fire-and-forget” messages IP (Internet Protocol) Ethernet General network info POWERFUL TECHNOLOGY HTTP:// - ”Many to one” connection Web Browser Computer Computer Internet/ Wide Area Network Computer • • • HTTP (hyper Text transfer Protocol) is a client / server protocol. Used when detailed info about one Computer site is wanted. Max.Recommended users at same time: < 10 General network info POWERFUL TECHNOLOGY SNMP: ”One to many” connection Network Management Systems NuDesign HPOpenview SNMPc Workstation • Simple Network Management Protocol “System” Designed for monitoring a large number of network devices simultaneously. • Central office supervision of country wide networks Internet/ Wide Area Network General info POWERFUL TECHNOLOGY Telnet: ”Point to Point” Terminal connection Hyperterminal Direct connection, No xtra config needed Internet/ Wide Area Network Computer Telnet is short for: ‘teletype over network’ or VT100 terminal interface on the network (instead of “serial port”) General info POWERFUL TECHNOLOGY FTP:”Point to Point” File transfer connection Internet/ Wide Area Network Computer “cuteFTP” software • The FTP protocol is for moving files over internet • The FTP server typically contains file storage (disk/flash etc) General info POWERFUL TECHNOLOGY E-Mail – ”One to many” messaging POP protocol Computer MAIL SERVER Computer Computer Internet/ Wide Area Network •An Alarm triggers an eMail to the mail server •The mail server forwards the email to receiver(s) General info POWERFUL TECHNOLOGY ”Tunneling” – A virtual serial port Internet/ Wide Area Network Computer Smart Suite pComm Header DATA Payload pComm Packet The data field in the TCP/IP packet contains a pComm packet SOURCE IP ADDRESS DESTINATION IPADDRESS DATA PAYLOAD TCP/IP Packet The data field in the ethernet packet contains the TCP/IP packet DESTINATION MAC ADDRESS SOURCE MAC ADDRESS Ethernet Packet DATA PAYLOAD ! TCP/IP is the transport media for pComm protocol only POWERFUL TECHNOLOGY 2. WebPower Configuration Configuration POWERFUL TECHNOLOGY Configuration and setup • Telnet (Network) – Fast and easy – Accessible from any network PC • Serial port (RS 232) – When network is not available – When Application software is corrupt – Special debug functions Com 1: Config port Com 0: pComm port Configuration POWERFUL TECHNOLOGY Software download through Serial port • • • • ’VT100’ Terminal interface to the basic monitor. Used when there is no application software present Or when network download failed. See manual for more info…. HOW TO: 1. Use MTTY terminal program 2. Set to 115200 baud, 8bit, 1stopbit 3. Press ’Connect’ button and power up Webpower 4. Within 2secs, Type uppercase letter A 5. When the nb> prompt appear type ’FLA<Enter>’ 6. Use ’Send File’ in the ’Transfer’ menu 7. Select the .S19 file you desire and click ’Open’ 8. Wait until finished ! Configuration POWERFUL TECHNOLOGY Configuration Menu overview Available in: Serial Port and Telnet Set: IP Address, NetMask, Gateway, DNS Server Read pComm driver info Read WebPower version info -------------- MAIN MENU --------------1: Setup Network Addresses 2: pComm driver info 3: WebPower info 4: SNMP: Trap Host Configuration 5: SNMP: NMS Configuration 6: Set pComm Baudrate *: ’Hidden’ Service menu -------- SNMP Trap Host MENU -------1: Set Trap IP Addr. & community 2: Set Trap repeat rate config 3: Set Off Trap config ----- SNMP NMS Config MENU ---1: Set Read Community string 2: Set Write Community string Set Trap IP Addr & community Set Trap repeat rate config Set Off Trap config Set Read Community String Set Write Community String Set pComm Baudrate R&D Debug functions only --------------- Debug MENU ---------------A: WebPower TRACE setup B: Dump user flash area (ASCII) C: Dump user flash area (HEX) D: Password: Set default W: Web Cfg: Set Default S: SNMP Cfg: Set Default ^: Erase user flash area 1: Show ARP 2: Show Counters 3: Dump Ethernet 4: x.x.x.x Do ping N: Set flash version Password: Set default Web Cfg: Set Default SNMP Cfg: Set Default Erase user flash area R&D Debug functions only Configuration POWERFUL TECHNOLOGY IP Address setup from network NetBurner IPsetup is used to configure WebPower network parameters. IP: The network address of the Webpower unit. The bits with a corresponding 1 in the Network mask must be set according to your network rules. Network Mask: A Filter that tell which bits in the network address that are fixed and which bits that can be changed. Gateway: Network traffic that do not fit to the network mask will be directed to the default (External) gateway DNS: Domain Name Server. Translates an URL to a network IP address. Send ‘www.bbc.co.uk’ to the dns server and it will magically respond with the IP address :212.58.224.84 Baudrate: This is the speed used at the configuration serial port, normally set to 115200bps NetBurner SW Configuration POWERFUL TECHNOLOGY IP Address setup from network HOW TO: 1. 2. 3. 4. Start NetBurner IPsetup Click on the button. ‘Select a Unit’, click on the unit you want to configure Fill in the ‘NDK Settings’ as below IP: Set according to your network rules. NEVER choose one at random Network Mask: Set according to your network rules. NEVER EVER choose one at random. GateWay: In a closed private network, leave at zeroes. DNS: In a closed private network, leave at zeroes. Baudrate: For Webpower, this shall always be 115200. Configuration POWERFUL TECHNOLOGY Software download from the Network AutoUpdate will download a new code image to your NetBurner card in the WebPower unit. This update can be done from any point that has network access In order to use AutoUpdate you must: I. Have a Static IP address and mask assigned to your NetBurner device. II. Have a working network connection between your host computer and your NetBurner device. Configuration POWERFUL TECHNOLOGY Software download from the Network HOW TO: 1. 2. 3. 4. 5. 6. 7. Start Autoupdate Click the button to locate your NetBurner device Select your NetBurner device, and click the button Next, click the button and an Open window will appear Select your _App.s19 file and click the button. Check Reboot when complete and click the button. A programming Complete without error message will pop up when ready POWERFUL TECHNOLOGY 3. WebPower Functionality Functionality POWERFUL TECHNOLOGY Webpower function overview Snmp supervision & Traps WebPower RS232 PCOMM HTTP SMTP (mail) Pcom Tunnelling (for contact w/WP & PowerSuite FTP Server for system configuration Telnet communcation config Functionality POWERFUL TECHNOLOGY • Abbreviations – SNMP- Simple Network Management Protocol. (Common platform for network management.) – NMS- Network Management System • Database client for monitoring and control of equipment – MIB- Management Information Base • Database that describes the information sent by the agent- stored in the NMS – TCP/IP- Internet protocol • Network protocol for sending SNMP messages – PCOMM- Power Communication protocol • Proprietary Eltek protocol for communication between control units and external PC’s or other equipment Functionality POWERFUL TECHNOLOGY SNMP Messages GET’s SET’s TRAP’s • GET’s – NMS system ask for status information on a specific parameter (MCU: appx.90%, Smartpack: Appx.70% of WP & PS Program func) • SET’s – NMS system sends a command to the rectifier system, I.e. change output voltage to 54 Vdc • TRAP’s – Alarm- messages sent from The Power system to the NMS Functionality POWERFUL TECHNOLOGY Webpower SNMP • GET’s available: GET Computer – – – – – – – – – – – – Site information Operational Status (Boost/Test etc.) Boost and test config and status Output voltage System-, battery- and load- current Battery Symmetry data Mains voltages Battery temperature Individual rectifier status Contactor and Fuse status Time and date Alarms and alarm configuration Functionality POWERFUL TECHNOLOGY Webpower SNMP • SET’s available: – – – – – – – – – Voltage adjustment TempComp charging enable Charge Current limitation Boost and battery test initialisation LVD Disconnect/Connect voltages Symmetry measurement configuration Set time and date Alarm trigger configuration Site information SET Computer Functionality POWERFUL TECHNOLOGY Webpower SNMP Computer • TRAPS available: – – – – – – – – – – – – 2 Level High Battery Voltage 2 Level Low Battery Voltage 2 Level High battery temperature Low voltage disconnect, load and battery Mains Failure Battery fuse failure Load fuse failure 2 Level Rectifier Failure 2 Level Battery Symmetry failure Battery Test/Boost started Battery Test Failed Plus any-user defined alarm/ event TRAP Computer Computer Functionality Typical SNMP Setup POWERFUL TECHNOLOGY Functionality POWERFUL TECHNOLOGY SNMP Network Management system Uses Active Icons over Graphical Display When Alarm is Received Icon will flash. 3’rd party SW ! Activating Icon will initiate SmartSuite and connect to correct site Functionality POWERFUL TECHNOLOGY Webpower; WEB interface Menu overview • • • Home page with system data and site information Alarm Status information page Administration page System Function enable/disable Network address and mail setup • • • • • Battery Test Setup Battery Boost Setup Regulation mode / current limit setup Battery monitor System Levels System Voltages Contactor Setup • • • Site Info Relay Testing Alarm Log Functionality POWERFUL TECHNOLOGY WebPower window in IE window Demo page: http://webpower.eltekenergy.com Functionality POWERFUL TECHNOLOGY Telnet Config in Webpower Start a console window (cmd.exe), Hyperterminal or similar Command line based Telnet Hyperterminal login Functionality POWERFUL TECHNOLOGY Telnet Config in Webpower • Type password and user info to login: (default: admin – admin) Functionality POWERFUL TECHNOLOGY Webpower Telnet • Menu Structure revised Set: IP Address, NetMask, Gateway, DNS Server ! Only from serial port Read pComm driver info Read WebPower version info -------------- MAIN MENU --------------1: Setup Network Addresses 2: pComm driver info 3: WebPower info 4: SNMP: Trap Host Configuration 5: SNMP: NMS Configuration 6: Set pComm Baudrate *: ’Hidden’ Service menu -------- SNMP Trap Host MENU -------1: Set Trap IP Addr. & community 2: Set Trap repeat rate config 3: Set Off Trap config ----- SNMP NMS Config MENU ---1: Set Read Community string 2: Set Write Community string Set Trap IP Addr & community Set Trap repeat rate config Set Off Trap config Set Read Community String Set Write Community String Set pComm Baudrate R&D Debug functions only --------------- Debug MENU ---------------A: WebPower TRACE setup B: Dump user flash area (ASCII) C: Dump user flash area (HEX) D: Password: Set default W: Web Cfg: Set Default S: SNMP Cfg: Set Default ^: Erase user flash area 1: Show ARP 2: Show Counters 3: Dump Ethernet 4: x.x.x.x Do ping N: Set flash version Password: Set default Web Cfg: Set Default SNMP Cfg: Set Default Erase user flash area R&D Debug functions only Functionality Configuration: SNMP -------------- MAIN MENU --------------1: Setup Network Addresses 2: pComm driver info 3: WebPower info 4: SNMP: Trap Host Configuration 5: SNMP: NMS Configuration 6: Set pComm Baudrate *: ’Hidden’ Service menu Trap IP address: ---------- SNMP Trap Host MENU ----------1: Set Trap IP Addresses & community 2: Set Trap repeat rate config 3: Set Off Trap config Where to send ALARM Traps. i.e the NMS who monitors the system Up to 10 NMS addresses Community String: Just a simple ‘password’ Must match in NMS POWERFUL TECHNOLOGY Functionality Configuration: SNMP -------------- MAIN MENU --------------1: Setup Network Addresses 2: pComm driver info 3: WebPower info 4: SNMP: Trap Host Configuration 5: SNMP: NMS Configuration 6: Set pComm Baudrate *: ’Hidden’ Service menu ---------- SNMP Trap Host MENU ----------1: Set Trap IP Addresses & community 2: Set Trap repeat rate config 3: Set Off Trap config TRAP Repeat Rate: When to send ALARM Traps. 1. @ regular intervals when alarm is active 2. Only once when alarm starts Send Off TRAP: Send TRAP when Alarm goes off or only when Alarm goes on. POWERFUL TECHNOLOGY Functionality Configuration: SNMP -------------- MAIN MENU --------------1: Setup Network Addresses 2: pComm driver info 3: WebPower info 4: SNMP: Trap Host Configuration 5: SNMP: NMS Configuration 6: Set pComm Baudrate *: ’Hidden’ Service menu ----- SNMP NMS Configuration MENU ---1: Set Read Community string 2: Set Write Community string NMS Community Strings: • Simple Unencrypted password for reading and writing SNMP parameters • Must Match at NMS side NMS Read Write Access: • Defines Is this Webpower is open for write access or not. POWERFUL TECHNOLOGY Functionality POWERFUL TECHNOLOGY Configuration: Communication -------------- MAIN MENU --------------1: Setup Network Addresses 2: pComm driver info 3: WebPower info 4: SNMP: Trap Host Configuration 5: SNMP: NMS Configuration 6: Set pComm Baudrate *: ’Hidden’ Service menu Set pComm Baudrate pComm baudrate: • Must be set to 38400 for Smartpack systems (see manual) • Set to 9600 for AEON and MCU systems Functionality POWERFUL TECHNOLOGY Configuration: Service/Debug --------------- Debug MENU ---------------A: WebPower TRACE setup B: Dump user flash area (ASCII) C: Dump user flash area (HEX) D: Password: Set default W: Web Cfg: Set Default S: SNMP Cfg: Set Default ^: Erase user flash area 1: Show ARP 2: Show Counters 3: Dump Ethernet 4: x.x.x.x Do ping N: Set flash version -------------- MAIN MENU --------------1: Setup Network Addresses 2: pComm driver info 3: WebPower info 4: SNMP: Trap Host Configuration 5: SNMP: NMS Configuration 6: Set pComm Baudrate *: ’Hidden’ Service menu Set Defaults: • Passwords: Only passwords is reset • WebConfig: Alarm email and Tunneling parameters are reset. • SNMP Config: Trap Receiver IP addresses and community strings, Repeat rate and OffTrap active are reset. Functionality POWERFUL TECHNOLOGY FTP in Webpower (For config/edit of Smartpack. ADVANCED USERS ONLY!!) Only 2 files: Read only: Readme.txt Read/Write: Setup.csv, (excel ascii format) Functionality FTP in Webpower • Any parameter can be read or written (Smartpack only) • When file is written to WebPower (for copy of setup etc)…… 1. Setup.csv content is analysed and executed 2. File is deleted 3. A Reply.csv report file is created !! This is not a trivial task ! Contact R&D dept for Info !! POWERFUL TECHNOLOGY Functionality POWERFUL TECHNOLOGY Webpower Mail • Mail user: Some mail servers needs a user name • SMTP Server IP: The mail server’s IP address. The mail server must be configured to accept a mail relay from a Webpower IP address • From Address: The Webpowers(fake, can be anything)mailaddress. Pop.online.no • To Address 1: The mail address of recipient 1 smtp.online.no • To Address 2: The mail address of recipient 2 Functionality POWERFUL TECHNOLOGY Webpower Tunneling • PowerSuite SW through embedded & stand-alone Webpower unit available on next SW version for Webpower WebPower Hardware POWERFUL TECHNOLOGY Note jumpersettings! T1,25A fuse External WebPower Hardware POWERFUL TECHNOLOGY Embedded WebPower in SmartPack