* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download Pole Mounted Switch Disconnector NPS
Mains electricity wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Alternating current wikipedia , lookup
Fuse (electrical) wikipedia , lookup
Opto-isolator wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Electrical substation wikipedia , lookup
Rectiverter wikipedia , lookup
Buck converter wikipedia , lookup
Pole Mounted Switch Disconnector NPS 630 A, up to 36 kV NPS Pole Mounted Switch Disconnectors In operation everywhere in Medium Voltage Networks with or without automation systems. With references around the world from the Artic Circle to the most tropical of jungles. ABB is a global market leader in power technology products. We offer efficiency, quality and competitiveness. We believe that flexible solutions and competent support are key elements for your continued success. We also believe that your distribution system is cost-effective when it matches the requirements of the customers operation and process – no more and no less. That is why ABB develops and supplies solutions perfectly tuned to user requirements and standards. Through ABB’s worldwide presence, we can offer local support and service globally. As your partner; we believe that these are key elements that enable you to continuously improve the performance in your networks. Our NPS Switch Disconnector has been carefully designed and developed in co-operation with utilities providers to meet the most diverse of customer requirements and to maintain maximum flexibility. Highly reliable, our NPS can be the key element of your rural distribution applications. Index 3 4-5 NPS as a Line Switch Disconnector 6-7 NPS for Transformer Switch Disconnector/ NPF fuse holder 8-9 Components for substation switch disconnectors 10 Feeder Automation 11 Feeder Automation solutions for air insulated switch disconnectors 12-13 2 Dipee.info Reliable air break technology for your distribution network DTU Operating Device for pole mounted switch disconnectors type NPS or other types 14 Breaking devices on NPS24B for max. Ith/Idyn 16/40 kA 15 Breaking devices on NPS24A for max. Ith/Idyn 20/50 kA 15 Breaking devices on NPS36A for max. Ith/Idyn 21/52 kA 16 Unique design 17 Manual operating mechanisms 19 Technical data Reliable air break technology for your distribution network The NPS offers a complete range from off-load disconnectors to switch disconnectors with different breaking devices, all designed according to IEC standard for limited purpose and general purpose switch disconnectors. The design is made for all climate conditions in different installations and building standards and can be either manually or remotely operated. The NPS also offer a modular construction which can easily be expanded or upgraded in the future. The extensive range of accessories makes the NPS suitable for every customer, pole and building standard. Flexible concept From the simplest of manually operated units to motorized and automated remotely controlled units Wide range of accessories Upgradeable in switching performances Enhanced performance and improved reliability Only insulators with the best materials are used - cycloaliphatic epoxy with over 30 years of field experience in more than 50 countries - high quality silicone or porcelain insulators are also available Lightweight design with a limited number of parts guarantees a long lifetime and trouble-free operation Easy and smart integrations Adaptable to all customer/ country building standards Modular concept Suitable for live working ABB / Pole Mounted Switch Disconnector NPS Dipee.info 3 NPS as a Line Switch Disconnector 4 Dipee.info ABB / Pole Mounted Switch Disconnector NPS Crossarm installation One of the most common building standards where the line switch disconnector is integrated on the same crossarm as the lines. Wooden poles are most often used for this type of installation. Installation below live line Some building styles and standards require a separate crossarm below the line crossarm. Sufficient clearances to the pole and between phases can be arranged by the flexible arrangement of phase elements. Installation above live line A typical installation example above the live line on a steel structure pole. Vertical installation Used for branching lines down to cables. The vertically installed switch disconnector is also used as a transformer switch disconnector. Two pole mounting All above examples are also available for two-pole mounting. Pole fitting accessories for various pole types are also available - wooden poles - concrete poles - steel poles and structures ABB / Pole Mounted Switch Disconnector NPS Dipee.info 5 NPS for Transformer Switch Disconnector/ NPF fuse holder 6 ABB / Pole Mounted Switch Disconnector NPS The NPS switch disconnector can be equipped with several types of fuse holders. The vertically mounted NPS can be used as transformer switch disconnector. The breaking capacity of the whip (25/50 A) is enough for disconnecting a fully loaded distribution transformer up to 800/1600 kVA. NPS24B1-J2 and NPAC5 If the pole element is horizontally mounted the fuse holder for HRC fuses (6.3, 16, 25 A) or (SMIA-KR_) melting fuses can be easily integrated (up to 63 A) to the switch disconnector. The fuses are replaced using isolated rods from ground level. NPS24B1-J2, NPAC9-J2 and NPAF7-J2 NPS can be equipped with integrated earthing contact for open and earthed position. The separate fuse holder for HRC and SMIA-KR_ can also be equipped with surge arresters for one-,two-, or three-phase installation. NPS24B1-J2 NPAE5 NPF24B2 NPS can be equipped with a separate fuse holder for DIN-type fuses (CEF outdoor HRC fuses). IEC 282 NPF24E5 ABB / Pole Mounted Switch Disconnector NPS 7.2 kV 12.0 kV 17.5 kV 24.0 kV 36.0 kV up to up to up to up to up to ANSI 160 A 100 A 100 A 100 A 40 A 15.5 kV 25.8 kV 38.0 kV 160 A 100 A 40 A 7 Components for substation switch disconnectors 8 ABB / Pole Mounted Switch Disconnector NPS A wide range of accessories are available for different substation solutions. The modular construction of NPS enables the most demanding customer requirements to be fulfilled. NPS24B1-J2 NPAC7 NPS24B1-J2 KOHU24A2 MWK NPS24B1-J2, NPAC9-J2 and NPAF7-J2 Third insulator with flexible bars. Flexible droppers and additional insulators for lowering the cable connections. CT’s and Surge arresters. Basic disconnector module. NPS24B1-WWJ2 25 A NPS24B1-J2 KOHU24A2 MWK 50 A NPS24B1-J2 NPS24B1-K1J2 250 A 630 A Automatic earthing in open position. NPS24B1-J2 NPAE5 Earthing on one or both sides. NPS24B1-J2 NPS-ZM1 NPS24B-K4J2 NPS24B1-K5J2 Fuse base with support for surge arrester. NPF24B2 ABB / Pole Mounted Switch Disconnector NPS 9 Feeder Automation 10 ABB / Pole Mounted Switch Disconnector NPS Feeder Automation solutions for air insulated switch disconnectors Our disconnector terminal units [DTU’s] are designed for remote control and local automation applications of NPS switch disconnectors and other similar types with up/down operating movement. Together with REC 501 or REC 523 monitoring and control units both simple applications such as remote open/close operations and more sophisticated auto sectionalizing schemes and measurements can be realized. UEMC50 Standard communication protocols available for ANSI X3.28 HD only with REC 501 RP570 only with REC 501 IEC 60870-101, unbalanced MODBUS ASCII & RTU format DNP 3.0 DTU115 Analog inputs available for standard CT’s and VT’s. DTU135 DTU’s can also be used without integrated motor mechanism. These can be used in applications such as master terminal for monitoring and controlling existing motor devices for indoor and outdoor switch disconnectors and other motor operated apparatus. It is also applicable for switching devices with an integrated actuator. DTU131 UEMC-A One terminal with REC 523 can control up to 4 slave units ○○ ○○ ○○ ○○ ○○ ○○ ○○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ DTU135 ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○○ DTU115 ○○ ○○ ○○ ○○ ABB / Pole Mounted Switch Disconnector NPS ○○ ○○ ○○ ○○ UEMC50L1-24VDC ○○ ○○ ○○ ○○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ UEMC50H1-24VDC 11 DTU Operating Device for pole mounted switch disconnectors type NPS or other types 12 ABB / Pole Mounted Switch Disconnector NPS UEMC50L1 UEMC50H1 DTU111 UEMC-A2 DTU131 UEMC-A3 The product range includes master and slave units Can be equipped with third party electronics/IED Two different cabinet sizes Complete with batteries and chargers Up/down tube operation of disconnectors Stainless steel cabinet and mechanism Dust tight (IP55) to secure long lifetime of critical electrical components High torque, alternative 1.2 sec or 3 sec operating time Best possible materials used Over 30 years experience Operating voltages: 24, 48, 110, 220 VDC 110, 230 VAC Terminals for installing different IED’s. Cabinets available with different options for batteries, battery chargers etc. ABB / Pole Mounted Switch Disconnector NPS 13 Breaking devices on NPS24B for max. Ith/Idyn 16/40 kA Due to the flexible design of the basic phase element, the NPS can be equipped with a range of breaking devices. Data NPS Basic pole element Usage Disconnector (IEC) No breaking capacity For disconnecting functions only. Provides a safe isolating distance. Limited purpose switch disconnector (IEC) Breaking 25 A/24 kV 40 A/12 kV For disconnecting functions only. Provides a safe isolating distance. Limited purpose switch disconnector (IEC) Breaking 50 A/24 kV 80 A/12 kV With extended breaking capacity in rural areas and transformer loads. Limited purpose switch disconnector (IEC) Breaking 250 A/24 kV For main lines and substations where larger breaking capacity is needed. General purpose switch disconnector (IEC) Maximum - breaking - independent spring assisted making capacity 630 A/24 kV For main lines and substations where both breaking and making capacity is needed. This solution is excellent for remote and auto sectionalizers. NPS24B1-WWJ2 NPS with 25 A breaking whip NPS24B1-J2 NPS24B1-J3 NPS with 50 A breaking whip NPS24B1-K1J2 NPS with 250 A breaking chamber NPS24B1-K4J2 NPS with K5 air making and breaking chamber 8 kA/24 kV 12.5 kA/12 kV NPS24B1-K5J2, NPS24B1-K5J3 and NPAC9-J3 14 ABB / Pole Mounted Switch Disconnector NPS Breaking devices on NPS24A for max. Ith/Idyn 20/50 kA For overhead networks with BIL up to 150 kV. Silicone insulator J3 NPS24A2-J3 NPS24A2-K5J3 NPS24A2-K5J3 NPAC1-J3 Breaking devices on NPS36A for max. Ith/Idyn 21/52 kA For overhead networks with BIL, up to 200 kV NPS36 can be used. Whip (16 A) or breaking chamber K3 (400 A) can be used as breaking elements. Two alternative silicone insulators (J2 or J3) NPS36A2-J2 ABB / Pole Mounted Switch Disconnector NPS NPS36A2-K3J2 NPS36A2-K3J2 NPAC11-J2 15 Unique design The unique design on breaking whips and dry type breaking chambers eliminates the risk of oil leakage. Risk of oil eliminated Pollution risk for soil waters Safety risk in case of failed interruption No need to check oil level or compensate for possible leakages Risk of conventional air breaking chambers eliminated by protected breaking contacts Malfunctions due to dust, sand, ice and small animals Risk of terrain fires due to arcing The exceptionally high number of making operations [>50 times 8 kA] enables use to locate faulty line sections by operating against the fault. 16 Manual operating mechanisms UEKE 5A1 Hook stick lever Hook stick operation mechanism for NPS24B_ models. Also available for mounting on lower level. UEKO 1A1 One hand grip operating mechanism for low end disconnectors UEKE 3A1 Standard two hand grip operating mechanism for all NPS_ models. UEKE 3B1 Standard two hand grip operating mechanism for all NPS_ models with additional quick adjustment rod. UEKE 2/1 With auxiliary contacts and heating element IP55. ABB / Pole Mounted Switch Disconnector NPS UEKE 6A1 Wire operation 17 NPS Easy is factory assembled for 80 x 80 or 100 x 100 mm RHS-beam. 18 ABB / Pole Mounted Switch Disconnector NPS Technical data Type NPS24B1-J2 NPS24B1-J3 NPS24A2-J3 NPS36A2-J2 NPS36A2-J3 Insulator Epoxy Silicone Silicone Silicone Silicone - creepage mm 740 715 760 1205 1365 - arcing distance (insulator) mm 272 300 305 450 465 - arcing distance (min to earth) mm 200 255 260 380 385 - cantilever strength kN 2 9 9 6.2 6.2 - salt fog test, IEC 507, (1 h) salt solution g/l 160 - - - - Rated voltage, max. kV 24 24 24 36 36 Rated current A 630 630 630 630 630 Rated frequency Hz 50/60 50/60 50/60 50/60 50/60 kV 145 145 165 220 1) 220 1) 1) 200 1) Rated lighting impulse withstand voltage - across the isolating distance - to earth and between phases kV 125 125 150 200 kV 75 75 75 88 1) 88 1) 1) 80 1) Rated power frequency withstand voltage in wet conditions - across the isolating distance - to earth and between phases kV 55 55 55 80 mm 260 260 350 430 430 Min. isolating distance mm 200 200 230 350 350 Rated short-time withstand current 1 s kA 16 16 20 21 1) 21 1) 16 1) 52 1) Min. distance between phases 2) 3 s kA 12.5 12.5 16 16 1) kA 40 40 50 52 1) kA 5 12 kVA 40 40 40 - - 15 kVA 32 32 32 - - 24 kVA 25 25 25 16 16 36 kVA - - - 16 16 A 15 15 15 10 10 Operat. 2000 2000 2000 2000 2000 Permissible ice thickness mm - Ambient temperature limits °C -50…+40 -40…+40 - -40…+40 -40…+40 Rated peak withstand current Rated short-circuit making current Rated breaking current 3) 5 3) 5 3) 7.5 4) 7.5 4) 5) - mainly active load with 100 closing and opening operations - cable- and line-charging with 20 closing and opening operations Mechanical endurance 6) 1) Type NPS36A204 with earthing contact have lower ratings - lightning impulse withstand voltage 170 kV - power frequency wet withstand voltage 80 kV - short-time withstand current 16 kA 1 s - peak withstand current 40 kA 2) With breaking chambers 3) 7 closing operations, manual or motor 4) fast manual operation 5) When standard breaking whips are used special whips 24 kV 50 A available 6) With breaking chambers ABB / Pole Mounted Switch Disconnector NPS 19 NPS5GB 06-04/07-03 ABB Oy MV Apparatus & Switchgear P.O.Box 613, FI-65101 Vaasa, Finland Tel: +358 10 22 11 Fax: +358 10 22 44661 www.abb.com