Download SK-Zone Interface Module

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Audio power wikipedia , lookup

Ground (electricity) wikipedia , lookup

Electrification wikipedia , lookup

Buck converter wikipedia , lookup

Stray voltage wikipedia , lookup

Electric power system wikipedia , lookup

Islanding wikipedia , lookup

Pulse-width modulation wikipedia , lookup

History of electric power transmission wikipedia , lookup

Immunity-aware programming wikipedia , lookup

Electrical substation wikipedia , lookup

Power over Ethernet wikipedia , lookup

Power engineering wikipedia , lookup

Voltage optimisation wikipedia , lookup

Alternating current wikipedia , lookup

Distribution management system wikipedia , lookup

Earthing system wikipedia , lookup

Switched-mode power supply wikipedia , lookup

Rectiverter wikipedia , lookup

Mains electricity wikipedia , lookup

Electrical wiring in the United Kingdom wikipedia , lookup

Solar micro-inverter wikipedia , lookup

Transcript
I56-3440-001
installation and maintenance instructions
12 Clintonville Road, Northford, CT 06472
203.484.7161; Fax: 203.484.7118
www.silentknight.com
SK-Zone Interface Module
Specifications
Normal Operating Voltage:
15 to 32 VDC
Maximum Current Draw:
5.1 mA (LED on)
Average Operating Current:
270µA (LED flashing)
EOL Resistance:
3.9K Ohms
Maximum IDC Wiring Resistance:
25 Ohms
External Supply Voltage (between Terminals T10 and T11)
DC Voltage:
Regulated 24 VDC
Ripple Voltage:
0.1 Volts RMS maximum
Current:
90mA per module
Temperature Range:
32˚F to 120˚F (0˚C to 49˚C)
Humidity:
10% to 93% Non-condensing
Dimensions:
41/2˝ H × 4˝ W × 11/4˝ D (Mounts to a 4˝ square by 21/8˝ deep box.)
Accessories:
SMB500 Electrical Box
Before Installing
This information is included as a quick reference installation guide. Refer to
the control panel installation manual for detailed system information. If the
modules will be installed in an existing operational system, inform the operator and local authority that the system will be temporarily out of service. Disconnect power to the control panel before installing the modules.
Mounting
The SK-Zone mounts directly to 4-inch square electrical boxes (see Figure 2).
The box must have a minimum depth of 21/8 inches. Surface mounted electrical boxes (SMB500) are available from Silent Knight
Wiring
NOTE: All wiring must conform to applicable local codes, ordinances, and
regulations. This module is intended for power-limited wiring only.
NOTICE: This manual should be left with the owner/user of this equipment.
General Description
The SK-Zone Interface Module is intended for use in intelligent, two-wire
systems, where the individual address of each module is selected using the
built-in rotary switches. This module allows intelligent panels to interface and
monitor two-wire conventional smoke detectors. It transmits the status (normal, open, or alarm) of one full zone of conventional detectors back to the
control panel. All two-wire detectors being monitored must be UL compatible
with this module.
1.Install module wiring in accordance with the job drawings and appropriate wiring diagrams.
2. Set the address on the module per job drawings.
3.Secure module to electrical box (supplied by installer), as shown in
Figure 2.
Figure 2. Module mounting:
Compatibility Requirements
To ensure proper operation, this module shall be connected to a compatible
Silent Knight system control panel only (list available from Silent Knight).
Figure 1. Controls and indicators:
ISOLATED
QUADRANT
C1059-00
C1066-00
Compatible Two-wire System Sensor Smoke Detectors for Use with SK-Zone Interface Module with Zone Identifier A:
Detector
Model
1451
2451
2451TH
1400
2400
2400TH
1100
1151
2100
2100T
2151
Compatibility
ID
A
A
A
A
A
A
A
A
A
A
A
Detector
Type
Ionization
Photoelectric
Photoelectric with Thermal
Ionization
Photoelectric
Photoelectric with Thermal
Ionization
Ionization
Photoelectric
Photoelectric with Thermal
Photoelectric
Base
Model
B401/B
B401/B
B401/B
N/A
N/A
N/A
N/A
B110LP/B401
N/A
N/A
B110LP/B401
Base
Identifier
A
A
A
—
—
—
—
A
—
—
A
Max
Detectors
20
20
20
20
20
20
20
20
20
20
20
*Used in combination with MTL isolator model MTL3043.
SK-460-012
1
I56-3440-001
Figure 3. Interface two-wire conventional detectors, NFPA Style B:
POWER TO THE INTERFACE
MODULE MUST BE EXTERNALLY
SWITCED TO RESET THE
DETECTORS. A RELAY CONTROL
MODULE CAN BE USED TO SWITCH
POWER FROM A STANDARD POWER
SUPPLY (SEE FIGURE 5).
OPTIONAL BRANCH CIRCUIT
TO NEXT INTERFACE
MODULE. MODULE
SUPERVISES SUPPLY
VOLTAGE AND
DETECTOR LOOP.
LISTED BATTERY-BACKUP SWITCHED
REGUALTED DC POWER SUPPLY
TO NEXT
DEVICE
)–(
)–(
)+(
)+(
INTERFACE
MODULE
FROM
PANEL OR
PREVIOUS
DEVICE
SIGNAL LINE CIRCUIT (SLC)
32 VDC MAX.
TWISTED PAIR
IS RECOMMENDED
(–)
)–(
(+)
)+(
CONNECT MODULES TO
LISTED COMPATIBLE
CONTROL PANELS ONLY.
TERMINAL WIRING MUST
BE POWER LIMITED.
3.9K EOL
RESISTOR
(INCLUDED)
A2143-10
+
+
–
–
DO NOT MIX FIRE ALARM INITIATING, SUPERVISORY,
OR SECURITY DEVICES ON THE SAME MODULE.
*NOTE: ANY FAULT IN THE POWER SUPPLY IS LIMITED TO THAT
ZONE AND DOES NOT RESULT IN A FAULT IN A SEPARATE ZONE.
DO NOT LOOP WIRE UNDER TERMINALS. BREAK ALL WIRE RUN TO PROVIDE SUPERVISION OF CONNECTIONS. DETECTORS MUST
BE UL LISTED COMPATIBLE WITH MODULE. INSTALL DETECTORS PER MANUFACTURER’S INSTALLATION INSTRUCTIONS
C1061-00
Figure 4. Interface two-wire conventional detectors, NFPA Style D:
POWER TO THE INTERFACE
OPTIONAL BRANCH CIRCUIT
MODULE MUST BE
TO NEXT INTERFACE MODULE.
EXTERNALLY SWITCED TO
MODULE SUPERVISES SUPPLY
RESET THE DETECTORS. A
VOLTAGE AND
RELAY CONTROL MODULE CAN
DETECTOR LOOP.
BE USED TO SWITCH POWER
FROM A STANDARD POWER
SUPPLY (SEE FIGURE 5).
LISTED
BATTERY-BACKUP
SWITCHED REGUALTED
DC POWER SUPPLY
TO NEXT
DEVICE
)–(
)–(
)+(
)+(
FROM
PANEL OR
PREVIOUS
DEVICE
INTERFACE
MODULE
SIGNAL LINE CIRCUIT (SLC)
32 VDC MAX.
TWISTED PAIR
IS RECOMMENDED
(–)
)–(
(+)
)+(
CONNECT MODULES TO
LISTED COMPATIBLE
CONTROL PANELS ONLY.
3.9K EOL RESISTOR
REQUIRED AT TERMINALS
8 & 9 (INCLUDED) A2143-10
TERMINAL WIRING MUST
BE POWER LIMITED.
+
+
−
−
DO NOT MIX FIRE ALARM INITIATING, SUPERVISORY, OR SECURITY
DEVICES ON THE SAME MODULE.
*NOTE: ANY FAULT IN THE POWER SUPPLY IS LIMITED TO THAT
ZONE AND DOES NOT RESULT IN A FAULT IN A SEPARATE ZONE.
DO NOT LOOP WIRE UNDER TERMINALS. BREAK ALL WIRE RUN TO PROVIDE SUPERVISION OF CONNECTIONS. DETECTORS
MUST BE UL LISTED COMPATIBLE WITH MODULE. INSTALL DETECTORS PER MANUFACTURER’S INSTALLATION INSTRUCTIONS
C1062-00
Figure 5. Relay control module used to disconnect a power supply:
TO NEXT
DEVICE
)–(
)–(
)+(
)+(
FROM
PANEL OR
PREVIOUS
DEVICE
RELAY CONTROL
MODULE
SIGNAL LINE CIRCUIT (SLC)
32 VDC MAX.
TWISTED PAIR
IS RECOMMENDED
POWER LIMITED DC
POWER SUPPLY,
)+(
LISTED FOR FIRE
PROTECTION WITH
)–(
BATTERY BACKUP
)–(
)+(
CONNECT MODULES TO LISTED COMPATIBLE
CONTROL PANELS ONLY.
)–(
)+(
*NOTE: ANY FAULT IN THE POWER SUPPLY IS
LIMITED TO THAT ZONE AND DOES NOT
RESULT IN A FAULT IN A SEPARATE ZONE.
C0945-00
SK-460-012
2
I56-3440-001
©2009 Honeywell International Inc.