Survey
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Board Exam Problems on AC MACHINES (Alternators) 41 1. The number of cycles generated in a 10 pole alternator in one revolution is A. 2 B. 5 C. 10 Solution: ππ. ππ ππ¦ππππ πππ£ ο· 2. 1 ππ¦πππ =( ππ. ππ 2 ππππ ππππππ πππ )( 10 πππππ πππ£ . D. 20 ) = π ππππππ/πππ What is the number of electrical degrees made per revolution for a special purpose 40 pole alternator. A. 28, 800 B. 14, 400 C. 7, 200 D. 1, 600 Solution: ππ. ππ πππππ‘πππππ πππ/πππ£ = ( 180° ππππ ο· 40 πππππ )( πππ£ ) ππ. ππ ππππππππππ π ππ/πππ = π, πππ°/πππ 3. Alternators are usually designed to generate A. variable frequency B. definite currents C. definite frequencies D. definite p.f 4. A 4-pole, 3-phase, star-connected alternator armature has 12 slots with 24 conductors per slot and the flux per pole is 0.1 Wb sinusoidally distributed. Calculate the line emf generated at 50 Hz. A. 1, 066 V B. 3, 198 V C.1, 846 V D. 5, 538 V Solution: 24 πππππ’ππ‘πππ πβ = ( ο· π πππ‘ )(12 π πππ‘π )( 1 π‘π’ππ 2 πππππ’ππ‘πππ )( 1 3 πβππ π ) πβ = 48 π‘π’πππ /πβππ π 1 turn 1 conductor 1 conductor πΈβ = 4.44ππβ β πΈβ = 4.44(50 π»π§)(48 π‘π’πππ /β )(0.1 ο· ππ ππππ ) πΈβ = 1, 065.6 π πΈπΏ = β3πΈβ πΈπΏ = β3(1, 065.6) ο· π¬π³ = π, πππ. ππ π½ REE β May 2008 5. A three-phase wye-connected 50 Hz, 2-pole synchronous machine has a stator with 2, 000 turns of wire per phase. What rotor flux would be required to produce a terminal (line to line) voltage of 5 kV? A. 8.4 mWb B. 6.5 mWb C. 5.2 mWb D. 7.8 mWb Solution: πΈβ = 4.44ππβ β πΈβ = ο· πΈπΏ β3 = 5,000 β3 πΈβ = 2, 886.75 ππππ‘π 42 πΈβ β = 4.44ππβ 2,886.75 β = 4.44(50)(2,000) ο· β = π. π × ππβπ πΎπ REE β April 2006 6. A 3-phase, 8-pole generator is delta-connected. The terminal voltage is 2, 400 Volts while the line current is 500 Amperes. If the machine is converted to wye, what will be the terminal voltage in volts? A. 4, 800 V B. 4, 157 V C. 4, 600 V D. 3, 800 V Solution: β π€βππ πππππππ‘ππ ππ ππππ‘π ο· πΈβ = πΈπΏ = 2, 400 ππππ‘π β π€βππ πππππππ‘ππ ππ π€π¦π πΈπΏ = β3πΈβ πΈπΏ = β3(2, 400) ο· π¬π³ = π, πππ. ππ π½ππππ REE β September 2005 7. A three-phase, 8-pole, 2,400 Volts delta connected generator has a line current of 500 Amperes. If converted in wye, what is the tolerable current? A. 371.5 A B. 288.7 A C. 245.1 A D. 315.2 A Solution: β π€βππ πππππππ‘ππ ππ ππππ‘π πΌβ = πΌπΏ β3 = 500 β3 ο· πΌβ = 288.68 π΄ππππππ β π€βππ πππππππ‘ππ ππ π€π¦π ο· π°π³ = π°β = πππ. ππ π¨ππππππ 8. If the alternator winding has fractional pitch of 4/5, the pitch factor ππ is A. 0.833 Solution: B. 0.966 4 π° = (180°) 5 C. 0.972 . D. 0.951 full-pitch coil span or 1 pole span ο· π° = 144 π° ππ = π ππ( ) ππ = π ππ( 2 144 2 ) ο· ππ = π. πππ 9. A six pole, three-phase alternator has 72 slots and a coil span of 1 to 10, what is the pitch factor? A. 0.924 B. 0.939 C. 0.966 D. 0.985 Solution: 43 10-1= 9 slots 1 π° = ο· 10 (10β1)π πππ‘π 72 π πππ‘π 6 ππππ (180°) π° = 135 π° ππ = π ππ( ) ππ = π ππ( ο· 2 135 2 ) ππ = π. πππ 10. The power factor of an alternator is 75%. The operator is ordered to increase the power factor to 80%. What shall he do? A. increase the voltage B. operate the governor C. increase the excitation D. decrease the excitation 11. Calculate the distribution factor for a 36-slot, 4-pole three phase winding. A. 0.924 B. 0.951 C. 0.960 Solution: π= D. 0.975 36 π πππ‘π (4 ππππ)(3 πβππ ππ ) π πππ‘π ο· π° = π=3 ππππ /πβππ π 180° ( )(4 πππππ ) ππππ ο· 36 π ππ‘π π° = 20° π° ππ° = ππ° = ο· π ππ π( 2 ) π° 2 20° π ππ 3( 2 ) 20° 3 π ππ( ) 2 π π ππ( ) ππ ° = π. πππ 12. A 144-slot stator has a whole-coiled 12 pole three-phase winding. What is the number of coils per phase and per group, respectively? A. 12 and 4 B. 24 and 4 C. 36 and 4 D. 48 and 4 Solution: ππ. ππ πππππ πππ πβππ π = 1 ππππ )(144 π πππ‘) π πππ‘ ( 3 πβππ π 44 ο· ππ. ππ πππππ πππ πππππ = ππ πππππ πππ πππππ ππ. ππ πππππ πππ ππππ’π = ο· 48 πππππ /πβππ π 12 ππππ’ππ /πβππ π ππ. ππ πππππ πππ πππππ = π πππππ πππ πππππ 13. A part of an alternator winding consists of six coils in series, each coil having an e.m.f of 10 Volts (r.m.s) induced in it. The coils are placed in successive slots and between each slot and the next, there is an electrical phasor displacement of 30°. Find the e.m.f of the six coils in series. A. 77.28 V B. 9.66 V C. 38.64 V D. 19.32 V Solution: πΈπ = πΈπ1 + πΈπ2 + πΈπ3 + πΈπ4 + πΈπ5 + πΈπ6 πΈπ = 10β 0° + 10β 30° + 10β 60° + 10β 90° + 10β 120° + 10β 150° ο· π¬πΉ = ππ. ππβ ππ° π½ππππ 14. The following information is given in connection with an alternator: π πππ‘π = 144; πππππ = 8; πππ = 900; π‘π’πππ πππ ππππ = 6; β = 1.8 × 106 ; ππππ π πππ = π πππ‘π 1 π‘π 16; π€ππππππ πππππππ‘ππππ = π π‘ππ. What is the voltage generated between terminals? A. 1, 276 V B. 2, 210 V C. 635 V D. 1, 100 V Solution: (16β1)π πππ‘π π° = 144 π πππ‘π 8 πππππ ο· ( 180° ππππ ) π° = 150° π° 150° 2 2 ππ° = π ππ ( ) = π ππ( ο· π= ππ° = 0.966 144 π πππ‘π (8 πππππ )(3 β ) π πππ‘π ο· π° = π=6 ππππ /πβππ π 180° ( )(8 πππππ ) ππππ 144 π πππ‘π ο· π° = 10°/π πππ‘ π° ππ° = π ππ π( 2 ) π° π π ππ( ) 2 ο· π= ) 10° = π ππ 6( 2 ) 10° 6 π ππ( ) 2 ππ° = 0.956 π×πππ 120 ο· = 2(900) 120 π = 60 π»π§ 6 π‘π’πππ πβ = ( ππππ )( 1 ππππ π πππ‘ )(144 π πππ‘π )( 1 3 πβππ π) ο· πβ = 288 π‘π’πππ /πβππ π πΈβ = 4.44(ππ°)(ππ°)ππβ β × 10β8 πΈβ = 4.44(0.966)(0.956)(60)(288)(1.8 × 106 )(10β8 ) ο· πΈβ = 1, 275.36 ππππ‘π πΈπΏ = β3πΈβ = β3(1, 275.36) ο· π¬π³ = π, πππ π½ππππ 15. The disadvantage of a short-pitch coil is that . A. harmonics are introduced B. waveform becomes non-sinusoidal C. voltage around the coil is reduced D. both a and b 45 16. A 4-pole alternator, on open circuit, generates 200 Volts at 50 Hz when the field current is 4 Amperes. Determine the generated e.m.f at a speed of 1, 200 rpm and a field current of 3 Amperes, neglecting saturation in the iron parts. A. 40 V B. 240 V C. 60 V D. 120 V Solution: πΈ = πππΌπ πΈ1 = ππ1 πΌπ 1 πΈ1 π= π1 πΌπ (50)(4) 1 ο· π2 = 200 = π=1 π×πππ 120 = 4(1,200) 120 ο· π2 = 40 π»π§ πΈ2 = ππ2 πΌπ 2 πΈ2 = 1(40)(3) ο· π¬π = πππ π½ππππ 17. A 3-phase. Wye-connected alternator having a sinusoidal line potential with a 5% 5 th harmonic content, 3% 7th harmonic content, 1.5% 11th harmonic content and 0.85% 13 th harmonic content. What is the total harmonic distortion (THD) of the system line voltage? A. 11% B. 9% C. 6% D. 3% Solution: ππ»π· = β ππ»π· = β ο· πΈ5 2 +πΈ7 2 +πΈ11 2 +πΈ13 2 πΈ1 (0.05πΈ1 )2 +(0.03πΈ1 )2 +(0.015πΈ1 )2 +(0.0085πΈ1 )2 πΈ1 π»π―π« = π. ππ% 18. A 100 MVA, 13.8 kV, three-phase, wye-connected alternator will have a per phase nominal impedance of . β¦ A. 3.5 ββ B. 2.9 β¦ββ C. 1.9 β¦ββ D. 7.5 β¦ββ Solution: πβ = πβ = ππ 2 πππ΄ 13.82 100 πβ = π. π β¦ββ ο· REE β March 1998 19. A generator is rated 100 MW, 13.8 kV and 90% power factor. The effective resistance to ohmic resistance is 1.5. The ohmic resistance is obtained by connecting two terminals to a d.c source. The current and voltage are 87.6 amperes and 6 Volts, respectively. What is the resistance per phase? A. 0.0617 β¦ π©. π. ππππ β¦ C. 0.0685 β¦ D. 0.342 β¦ Solution: π π‘ = πππ πΌππ ο· π π ππ = = 6 87.6 π π‘ = 0.0685 β¦ π π‘ 2 = β dc ohmic resistance between terminals 0.0685 2 π π ππ = 0.03425 β¦ 46 ο· π΄πΆ ππππ‘ππ = π π π π ππ π π = 1.5(0.03425) ο· πΉπ = π. ππππ β¦/β REE β April 2006 20. A single-phase alternator gives 250 Amperes at 1, 200 Volts. What is the output of the machine in KVA? A. 300 B. 450 C. 400 D. 350 Solution: πΎππ΄ππ’π‘ππ’π‘ = πΎππ΄ππ’π‘ππ’π‘ = ο· ππΏ πΌ πΏ 1,000 (1,200)(250) 1,000 π²π½π¨ππππππ = πππ 21. High speed alternators have a rotor construction A. similar to d.c. machines B. of non-salient type C. of salient type D. none of these 22. The imaginary or fictitious part of synchronous reactance on alternator takes care of A. inductive reactance B. leakage reactance C. armature reaction D. copper losses REE β April 2006 23. A single-phase generator delivers 80 A at 240 V and 75% lagging p.f. What kind of load is the generator supplying? A. capacitive B. resistive C. inductive D. reactive REE β September 2004 24. A 3,600 Volts, 500 kVA, 60 Hz, three-phase, Y-connected generator on test yields the following results: Mechanical and iron losses are 10 kW; field current at full load 100% p.f is 50 Amperes; field current at full load 80% p.f is 70 Amperes; resistance per phase of armature winding is 0.4 ohm. The exciter voltage is constant at 120 Volts and voltage control is done by means of rheostat. Determine the full load armature current at 80% lagging p.f A. 96.5 A B. 99.8 A C. 64.2 A D. 80.2 A Solution: πΌπ = πΌπΏ = πΌπ = πΎππ΄ππ’π‘ππ’π‘ (1,000) β3 (500)(1,000) ο· β3 π°π = ππ. ππ π¨ππππππ REE β April 2005 25. A single-phase 2, 400 Volts synchronous generator delivers 450 Amperes at unity power factor. The synchronous impedance of the generator is 0.08 + π2.8 β¦. What is the regulation in percent? A. 14.2 B. 16.3 C. 20.1 D. 18.4 Solution: πΈπ = ππ‘ + πΌπ ππ πΈπ = 2, 400β 0° + (450β 0°)(0.08 + π2.8) 47 ο· πΈπ = 2, 742.57β 27.35° ππππ‘π %π. π = %π. π = ο· πΈπ βππ‘ × 100 ππ‘ 2,742.57β2,400 2,400 × 100 %π½. πΉ = ππ. ππ% 26. A 25 kVa alternator has a total loss of 2, 000 watts when it delivers rated kVA to a load at a power factor of 0.76. Calculate its percent efficiency. A. 90.48% B. 92.32% C. 91.58% D. 89.12% Solution: πππ’π‘ = πππ΄(π. π) = 25(0.76) ο· πππ’π‘ = 19 ππ Ι³= Ι³= πππ’π‘ × 100 πππ’π‘ +π‘ππ‘ππ πππ π 19,000 19,000+2,000 × 100 ο· Ι³ = ππ. ππ% REE β September 2010 27. A three-phase, wye-connected wound rotor synchronous generator rated at 10 kVA, 230 V has a synchronous reactance of 1.2 ohms/phase and an armature resistance of 0.5 ohm/phase. What is the percent voltage regulation at full-load with 85% lagging power factor? A. 18.3% B. 24.7% C. 20.8% D. 22.5% Solution: πβ = ππΏ β3 ο· β 0° = 230 β3 β 0° πβ = 132.79β 0° ππππ‘π πΌπ = πΌπΏ = πππ‘ππ πππ ×1,000 β3 ππΏπππ‘ππ = 10,000 β3 (230) πΌπ = 25.1β β 31.79° π΄ππππππ πΈπ = πβ + πΌπ ππ πΈπ = 132.79β 0° + (25.1β β 31.79° )(0.5 + π1.2) ο· πΈπ = 160.45β 6.8° ππππ‘π %π. π = %π. π = ο· πΈπ βπβ × 100 πβ 160.45β132.79 132.79 100 %π½. πΉ = ππ. π% REE β September 2010 28. A three-phase, wye-connected wound rotor synchronous generator rated at 10 kVA, 230 V has a synchronous reactance of 1.2 ohms/phase and armature resistance of 0.5 ohm/phase. What is the percent voltage regulation at full-load with 80% leading power factor? A. β 0.92% B. β 5.14% C. β 3.08% D. β 3.91% Solution: πβ = ο· ππΏ β3 β 0° = 230 β3 β 0° πβ = 132.79β 0° ππππ‘π πΌπ = πΌπΏ = 10,000 β3 (230) β πππ β1 0.80 ο· πΌπ = 25.1β 36.87° π΄ππππππ πΈπ = πβ + πΌπ ππ = 132.79β 0° + (25.1β 36.87° )(0.5 + π1.2) 48 ο· πΈπ = 128.69β 14.22° ππππ‘π %π. π = ο· πΈπ βπβ πβ × 100 %π½. πΉ = βπ. ππ% REE β May 2010 29. A three-phase wye-connected wound rotor synchronous generator rated at 10 kVA, 230 V has synchronous reactance of 1.2 ohms per phase and armature resistance of 0.5 ohm per phase. What is the power factor such that the voltage regulation at full load is zero? A. 0.837 leading B. 0.894 leading C. 0.869 leading D. 0.877 leading Solution: πΌπ = πΌπΏ = 10,000 β3 (230) β 0° ο· πΌπ = 25.1β 0° π΄ππππππ πΌπ ππ = (25.1β 0° )((0.5 + π1.2) ο· πΌπ ππ = 32.63β 67.38° ππππ‘π πβ = ο· ππΏ β3 β 0° = 230 β3 β 0° and %π. π = πΈπ βπβ πβ × 100 = 0 πΈβ = πβ = 132.79β 0° ππππ‘π πΌπ ππ πΈβ πΌπ ππ πΌπ = πΌπΏ 67.38° πΌ π πΌπ π π πβ β ππ¦ πππ πππ πππ€: πΈβ 2 = πβ 2 + (πΌπ ππ )2 β 2(πβ )(πΌπ ππ )πππ πΌ (132.73)2 = (132.73)2 + (32.63)2 β 2(132.73)(32.63)πππ πΌ πΌ = πππ β1 [ 32.632 ] 2(132.73)(32.63) ο· πΌ = 82.94° π = 180° β 82.94° β 63.78° ο· π = 29.68° π. π = πππ π = cos 29.68° ο· π. π = π. πππ ππππ πππ 30. A 1, 000 kVA, 3kV, 50 Hz, thee-phase star-connected alternator has an armature effective resistance of 0.2 β¦. A field current of 40 A produces a short-circuit current of 200 A and an open-circuit e.m.f of 1, 040 V (line value). Calculate the full load percentage regulation at a power factor of 0.8 lagging. 49 A. β21.43% Solution: B. 21.43% C. β24.31% D. 24.31 3,000 πβ = β3 ο· πβ = 1, 732.1β 0° ππππ‘π πΌπ = πΌπΏ = ο· β3 (3,000) β β πππ β1 0.80 πΌπ = 192.45β β 36.87° π΄ππππππ πΈππΆ ππ = 1,000(1,000) = πΌππΆ ο· 1,040/β3 200 ππ = 3 πβππ ππ = βππ 2 β π π 2 = β32 β 0.22 ο· ππ = 2.99 πβππ πΈπ = πβ + πΌπ ππ = 1, 732.1β 0° + (192.45β β 36.87° )(3 + π2.99) ο· πΈπ = 2, 152.92β 11.72° ππππ‘π %π. π = ο· πΈπ βπβ πβ × 100 = 2,152.92β1,732.1 1,732.1 × 100 %π½. πΉ = ππ. π% 31. Adjustment of field excitation on one of the two alternators operating in parallel will A. increase its load B. change its frequency C. decrease its load D. change its power factor REE β September 2001 32. A generator is being synchronized to a large system. The actual system voltage and frequency are 13.7 kV and 60 Hz, respectively. The generator voltage and frequency are 13.6 kV and 60 Hz, respectively. When the generator is switched to the system, choose which one happens, A. generator delivers MVAR B. generator takes MVAR C. generator delivers MW D. generator delivers both MW and MVAR Solution: π ππππ π‘βπ πππππππ‘ππ π£πππ‘πππ ππ πππ π π‘βππ π‘βπ π π¦π π‘ππ π£πππ‘πππ π‘βπ πππππππππ πππππ π΄π½π¨πΉ ππππ π‘βπ π π¦π π‘ππ 33. A 25 kVA, 220 Volts, three-phase alternator delivers rated kVA at a power factor of 0.84. The effective ac resistance between armature winding terminals is 0.18 β¦. The field takes 9.3 Amperes at 115 Volts. If friction and windage loss is 460 watts and the core loss is 610 Watts. Calculate the percent efficiency. A. 87.82% B. 84.27% C. 86.41% D. 88.33% Solution: πππ’π‘ = 25(0.84) ο· πππ’π‘ = 21 ππ πΌπ = 25,000 β3 (220) ο· πΌπ = 65.61 π΄ππππππ β π β πππππππ‘ππ π π = ο· π π‘ 2 = 0.18 2 π π = 0.09 πβππ π³πππππ: 1. πππππ‘π’ππ π€ππππππ 50 ππ = 3πΌπ 2 π π = 3(65.612 )(0.09) ππ = 1, 162.26 πππ‘π‘π 2. πππππ π€πππππππ ππ = ππ πΌπ = (115)(9.3) ππ = 1. 069.5 πππ‘π‘π 3. πππππ‘πππ πππ π€ππππππ πππ π πππ€ = 460 πππ‘π‘π 4. ππππ πππ π ππ = 610 πππ‘π‘π π‘ππ‘ππ πππ π ππ = ππ + ππ + πππ€ + ππ = 1, 162.26 + 1, 069.5 + 460 + 610 ο· Ι³= π‘ππ‘ππ πππ π ππ = 3, 301.76 πππ‘π‘π πππ’π‘ πππ’π‘ +ππππ π ππ ο· = 21 21+3.302 Ι³ = ππ. ππ% 34. When the speed of an alternator is changed from 3, 600 rpm to 1, 800 rpm, the generated emf/phase will become A. one half B. twice C. four times D. one fourth REE β September 2009 35. Two alternators operating in parallel supply 2, 500 kW to a load at a power factor of 80% lagging. If one machine delivers 1, 200 kW at a power factor of 95% lagging, what is the power supplied by the other machine? A. 1, 400 kW B. 1, 600 kW C. 1, 300 kW D. 1, 500 kW Solution: ππ‘ = π1 + π2 π2 = ππ‘ β π1 π2 = 2, 500 β 1, 200 ο· π·π = π, πππ ππΎ 36. Two exactly similar turbo-alternators are rated 20 MW each. They are running in parallel. The speed load characteristics of the driving turbines are such that the frequency of alternator one drops uniformly from 50 Hz on no-load to 48 Hz on full-load, that of the alternator two from 50 Hz to 48.5 Hz. How will the two machines share a load of 30, 000 kW? A. 14.56 MW, 15.44 MW B. 12.80 MW, 17.20 MW C. 17.47 MW, 12.53 MW D. 16.92 MW, 13.08 MW Solution: β πππ ππππππππππ π 50βπ 50β48 = ππ1 20 ο· ππ1 = 500 β 10π β πππ ππππππππππ π 50βπ 50β48.5 = β ππππππππ π ππ2 20 ππ2 = 666.67 β 13.33π 30 β ππ1 = 666.67 β 13.33π ο· ππ1 = 13.33π β 636.67 β ππππππππ π β ππππππππ π = ππππππππ π 500 β 10π = 13.33π β 636.67 51 π= 500+636.67 13.33+10 ο· π = 48.72 π»π§ ππ1 = 500 β 10π ππ1 = 500 β 10(48.72) ο· π΄πΎπ = ππ. π π΄πΎ ππ2 = 666.67 β 13.33π ππ2 = 666.67 β 13.33(48.72) ο· π΄πΎπ = ππ. π π΄πΎ 37. Each of two single-phase alternators has an armature winding whose resistance and synchronous reactance are respectively, 0.025 and 0.06 ohm. If the machines are operating without load, calculate the circulating current in the windings if the alternators are paralleled, when the emfs are equal at 230 Volts, but are displaced 30° from a position of phase opposition. A. 915 A B. 1, 830 A C. 457.5 A D. 119 A Solution: ππ 1 = ππ πΏ = π π + πππ ππ 1 = 0.025 + π0.06 ο· ππ 1 = 0.065β 67.38° β¦ π΅π¦ πΎππΏ: πΈ1 β πΌπ (ππ 1 + ππ 2 ) β πΈ2 = 0 πΌπ = πΌπ = πΈ1 βπΈ2 ππ 1 +ππ 2 230β 0°β230β β30° 2(0.065β 67.38°) ο· π°π = πππ. ππβ π. ππ° π¨ππππππ 38. A 3-phase 11 kV, 10 MVA alternator has a sequence reactances of positive sequence, π1 = π0.15 π. π’ ; negative sequence, π2 = π0.15 π. π’ and π0 = π0.15 π. π’, with negligible neutral wire reactance. If the alternator is on no-load, calculate the line to ground and 3-phase fault currents. A. 4, 499 A and 3, 499 A B. 2, 814 A and 2, 187 A C. 4, 499 A and 3, 030 A D. 1, 842 A and 854 A Solution: β πππ ππππ π‘π ππππ’ππ πππ’ππ‘ πΌπΉ = 3πΌπΏ πππ‘ππ ( πΌπΉ = 3 [ 1 π1 ππ’ +π2 ππ’ +π0 ππ’ 10×106 ]( β3 (11×103 ) ) 1 ) 0.15+0.15+0.15 ο· π°π = π, πππ π¨ππππππ β πππ π‘βπππ β πβππ π πππ’ππ‘ πΌπΉ = 3πΌπΏ πππ‘ππ ( πΌπΉ = 3 [ ο· 1 π1 ππ’ 10×106 ) ]( β3 (11×103 ) 1 0.15 ) π°π = π, πππ π¨ππππππ 39. In Problem No.37, when the voltages are in phase opposition, but one voltage is 230 and the other is 200 Volts. A. 462 A B. 231 A C. 400 A D. 800 A 52 Solution: β π΅πππ: ππ %π2 ππ πππ‘ πππ£ππ π‘βππ ππ π π’ππ π‘βππ‘ ππ‘ ππ πππ’ππ π‘π %π1 πΌπ = πΌπ = πΌπ = πΈ1 βπΈ2 ππ 1 +ππ 2 230β 0°β200β 0° 2(0.065β 67.38°) 230β 0°β200β 0° 2(0.065β 67.38°) ο· π°π = πππ. ππβ β ππ. ππ° π¨ππππππ 40. A 600 kVA, 2.4kV, 3-phase alternator has a zero phase sequence reactance of 12%, and a positive and negative phase sequence reactances of 8%. If the alternator resistance is negligible, determine the fault currents that the alternator can sustain if a three-phase fault occurs at its terminals. A. 1, 042 A B. 1, 804 A C. 3, 125 A D. 602 A Solution: β πππ π‘βπππ β πβππ π πππ’ππ‘ πΌπΉ = πΌπΏ πππ‘ππ ( πΌπΉ = [ ο· 100 ) %π1 600(1,000) 100 β3 (2,400) ]( 8 ) π°π = π, πππ. ππ π¨ππππππ 41. In Problem No. 40, determine the fault currents delivered if a phase to phase fault occurs at the alternator terminals. A. 1, 562 A B. 902 A C. 1, 804 A D. 3, 125 A Solution: /πΌπ /=/πΌπ /= β3 [πΌβ πππ‘ππ ( 100 %π1 +%π2 600(1,000) 100 /πΌπ /=/πΌπ /= β3 [ β3 (2,400) ]( 8+8 )] ) ο· /π°π /=/π°π /= π, πππ π¨ππππππ a πΌπ πΌπ fault b πΌπ c 53