* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download Broadband Communications over Power Lines (BPL)
Electrical substation wikipedia , lookup
Spectral density wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Utility frequency wikipedia , lookup
Power engineering wikipedia , lookup
History of electric power transmission wikipedia , lookup
Mains electricity wikipedia , lookup
Distribution management system wikipedia , lookup
Broadband Communications over Power Lines (PLC) By Marc C. Tarplee, Ph.D. N4UFP ARRL Technical Coordinator SC Section What is PLC? • PLC (also known as BPL) is a technique for sending high speed data through the medium voltage power distribution network • The idea of sending data through the power distribution network is not new – Utilities use LF for network control and telemetry (typically < 0.200 MHz) – Schools have used carrier current system for “campus radio” systems that operate in the AM band (0.530 – 1.700 MHz) • What makes BPL different is that it uses frequencies between 2 and 80 MHz 2. Types of PLC • There are three major categories of PLC: – Access PLC uses electrical distribution lines, overhead or underground, to provide broadband Internet access to homes and businesses. • This is currently in the developmental stage – In-building PLC uses the electrical wiring within a building to network computers. • Most systems use the HomePlug standard which provides protection for amateur frequencies – Control PLC operates below 500 kHz, and is used by electric-utility companies to control their equipment using the power-lines as transmission lines. • These systems are not a problem, although it is interesting to note that utilities successfully lobbied against an amateur VLF allocation, claiming that amateur transmissions could disrupt their communications. 3. PLC Modulation Techniques Access PLC • Access PLC systems are presently under development. Current systems use OFDM (orthogonal frequency division multiplexing) in combination with some type of PSK . • Carrier frequencies can be between 2 and 30 MHz. • No filtering provisions are made to protect other users of the HF/VHF spectrum • Data throughput > 10 Mb/sec HomePlug • HomePlug uses a combination of OFDM (orthogonal frequency division multiplexing) and DQPSK (differential quadrature phase shift keying) to send data through power lines within the home. • Carrier frequencies are between 4.5 and 21 MHz. • The modem output has notches at 3.5, 7.0, 10.1, 14.0, and 18.1 MHz to reduce interference to amateurs. • Data throughput > 10 Mb/sec HomePlug • Software in the receiver continuously determines the transfer function of the medium and carrier frequencies are changed to use the best available spectrum. • HomePlug signal power is spread over the entire 4.5 – 21 MHz bandwidth as the carrier frequencies are changed. • HomePlug signals can pass through a residential service entry panel with less than 10 dB loss. HomePlug Spectral Mask Control/Carrier Current PLC • These use frequencies below 1.7 MHz. – Carrier current AM signals 0.53 – 1.70 MHz – LF telemetry/control signals used by utilities <0.2 MHz • Signals have narrow bandwidth ( < 10 KHz) and have carrier frequencies below all amateur bands. • These signals do not generally present serious interference problems to amateurs • Data throughput << 1 Mb/sec 4. RFI from Access Line PLC • Tests involving PLC systems in Japan and Europe indicate that PLC can cause significant interference to other users of the HF spectrum. • Medium voltage power distribution lines look very much like antennas at HF wavelengths. • The next slide shows the far-field pattern of a 328 ft (100 m) segment of a typical MV distibution line. The conductors are at a height of 10m (32 ft 10 in) and they are spaced 1.5 m (4ft 5in) apart. The load is assumed to be the primary of a neighborhood transformer, which is assumed to have an impedance of 10 – j25 ohms. Elevation patterns for radiation from MV Power Lines Perpendicular to Lines Parallel to Lines 28 MHz 14 MHz 7 MHz 3.5 MHz 0.15 MHz +5 dBi 28 MHz 14 MHz 7 MHz 3.5 MHz 0.15 MHz +9 dBi • As might be expected, the power lines look like long wire antennas at HF, with some gain and a complex multi-lobed radiation pattern • It is interesting to note that the signal transmitted from the power lines in the LF range (150 kHz) is less than – 70 dbi in any direction. • Utilities’ RFI experience in the LF range is no predictor of RFI problems in the HF range. • Because overhead power lines run in all directions, the resultant field produced by the entire power distribution system should be more or less isotropic in the azimuthal plane. • ARRL simulations indicate that a fully-deployed access line PLC system would raise the noise floor by 70 dB (9 s-units + 16 dB) Japanese PLC RFI Study Noise Floor • These measurements were made at 7 MHz on a 96 km long path in Japan. • PLC signals raised the noise field strength by 25 dB Effect of PLC on HF Coverage > 75% ~ 50% < 25% 20 m Coverage under normal conditions 20 m Coverage with access PLC in neighborhood ARRL PLC Video 5. RFI from HomePlug PLC • HomePlug uses a spectral mask that provides 30 dB of filtering in the amateur HF bands. • At current RF brightness levels of –80 dBm/Hz, HomePlug signals can cause interference to antennas (especially indoor) that run within 2 – 3 m of household power lines. • HomePlug signals can also leak into other households with < 10 dB of attenuation, causing problems for all homeowners sharing a common transformer. 6. What Can Be Done? • The FCC recently closed off comment on the PLC docket. Hundreds of amateurs did comment on the problems with PLC during the comment period. • Measurements need to be made. If a utility is deploying PLC in your area, please make measurements of the noise. We need to show the FCC what the problems are. • It is very likely that some form of PLC will be implemented – the economic potential is to great. It is important for amateurs to help steer the implementation so that our frequencies are protected