Survey
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
UM PPS Lab Activities - HV Readout Long Run - Single Source Saturation Test PPS meeting April 30, 2012 Waveforms from 1 Run Last Week 4/30/2012 UM PPS Activities 2 HV Readout Long Run Setup • • • • • HV board with 11 lines [90,100] at 815V 7 out of 11 lines with the circuitry to read them out 4 consecutive HV lines 94-97 connected to the DRS Signal attenuation of 32 dB (40 times on amplitude) Source sitting on top of the 1 mm slit graphite collimator aligned over a single HV line (#96) • DRS threshold very low (60 mV) so that no matter what line had a pulse, the trigger line fired (Fan-in/Fan-out not OK) at the analysis lever a much harder threshold (200 mV) was used to select real hit-lines • Trick: DRS channel 3 signals is always smaller so 3230 dB 4/30/2012 UM PPS Activities 3 Number of HV Pulses/Event 125 2 4/30/2012 UM PPS Activities 4 HV Pulses Multiplicity per Channel Last week result on the left quite different from this long run: now almost only the closest line has hits, and they have a comparable rate. Important to check with a larger number of lines (small improvement the same test with the source on one of the two extreme lines) 4/30/2012 UM PPS Activities 5 HV Pulse Amplitude The trigger line (#3) has larger amplitude pulses (and #4 smaller) 4/30/2012 UM PPS Activities 6 HV Pulse Rise Time (10%-90%) 4/30/2012 UM PPS Activities 7 HV Pulse Width 4/30/2012 UM PPS Activities 8 HV Pulse Pseudo-Charge=|A|*W 4/30/2012 UM PPS Activities 9 Time Between Events Why this structure? 4/30/2012 UM PPS Activities 10 Saturation Test • Saturation: rate of incoming ionizing particles larger than the inverse of the pixel recovery time (RHV*Cpixel) limiting the number of discharges • PDP geometry fixes Cpixel measured ~10pF, and with HV quench resistor 200 MΩ RC~ 2ms max rate O(kHz) • Sources measured with a Geiger counter after one layer of glass: (1R=2.58*10-4 C/kg ~2.1*109 ion couples) – – 106Ru~130 mR/h ~7 ·104 ions/sec 90Sr~170 mR/h ~ 105 ions/sec over the entire source area ~1.3 cm2 (pixel ~1.5 mm2) • Idea: single HV line x 4 RO lines increasing the HV to maximize the probability of a plasma discharge in the gas. Above a certain threshold higher voltage should not produce more hits • Background events/rates are measured without any source and the data runs are only with 106Ru 4/30/2012 UM PPS Activities 11 Test with R(HV)=200 MΩ Based on the fit results at R(HV)=200 MΩ with C(pixel)=10 pF RC= 2 ms saturation @ 500 Hz reached at 1900.6 V 4/30/2012 UM PPS Activities 12 Test with R(HV)=1 GΩ Behavior not very linear. Hint of saturation at HV>930V (different HV line but same rate as before once RHV=200 MΩ s used) 4/30/2012 UM PPS Activities 13 Extended Test with R(HV)=1 GΩ The behavior seems more linear (except the first points) and the hint of saturation at HV>930V has disappeared 4/30/2012 UM PPS Activities 14 Full Test with R(HV)=1 GΩ Second set of points the day after: no hints of saturation! Jump of background events more and more important at higher HV 4/30/2012 UM PPS Activities 15 No Saturation. Really?! The ratio of the data rates with the two RHV values agrees with the ratio of the maximum rates based on the recovery time we were saturated the whole time! 4/30/2012 UM PPS Activities 16 Conclusions • The HV readout long test shows that almost always only one line has a pulse (are the nearby dead?) • A few features (like ΔT between events) not yet understood • Increasing the HV maybe/likely – increases the active pixel area – increases the active distance in the gas gap to have plasma discharges – reduces the recovery voltage to have a new discharge (only for low values of HV it is needed more than one recovery time to have back the line to a voltage high enough to produce another plasma discharge) • To test the saturation effect we will keep the voltage fixed and just change the quench resistor. We expect that starting from low RHV the rate will increase until a certain value after which it is constant 4/30/2012 UM PPS Activities 17