* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download Silcon Technical Specs - Detailed
Power engineering wikipedia , lookup
Three-phase electric power wikipedia , lookup
Opto-isolator wikipedia , lookup
Voltage optimisation wikipedia , lookup
Alternating current wikipedia , lookup
Buck converter wikipedia , lookup
Electric battery wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Power electronics wikipedia , lookup
Mains electricity wikipedia , lookup
Solar micro-inverter wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Power inverter wikipedia , lookup
Manualzz Categories o Baby & children o Computers & electronics o Entertainment & hobby o Fashion & style o Food, beverages & tobacco o Health & beauty o Home o Industrial & lab equipment o Medical equipment o Office o Pet care o Sports & recreation o Vehicles & accessories Top types Air Handlers Boom Lifts Compact Excavator Electrical equipment & supplies Finishers Measuring, testing & control Noise Reduction Machine Oxygen Equipment Personal safety & protection Robotics Scrubber Spreader Tractor Trash Compactor Welding System other → Top brands AEG Bosch Canon Carrier Craftsman Dell Electrolux Emerson Epson Maytag Mitsubishi Sharp Siemens Whirlpool Yamaha other → Top types Alarm clocks Blood pressure units Digital body thermometers Electric toothbrushes Epilators Hair dryers Hair straighteners Hair stylers Hair trimmers & clippers Humidifiers Massagers Men's shavers Personal scales Shaver accessories Women's shavers other → Top brands Black & Decker Bosch Emerson HP JVC Miele Motorola Panasonic Philips Samsung Sharp Siemens Sony Whirlpool Yamaha other → Top types Pill Reminder Device Stairlifts other → Top brands Alber Bruno E-PIL Minivator Savaria other → Top types Audio & home theatre Cameras & camcorders Computer cables Computer components Computers Data input devices Data storage Networking Print & Scan Projectors Smart wearables Software Telecom & navigation TVs & monitors Warranty & support other → Top brands Asus Black & Decker Bosch Canon Cisco Craftsman Dell Epson HP Motorola Philips Samsung Sharp Sony Yamaha other → Top types Cars Electric scooters Motor vehicle accessories & components Motor vehicle electronics Motorcycles Motorhomes Offroad Vehicle Scooters Utility Vehicle other → Top brands Audiovox Black & Decker Bosch Craftsman Electrolux Emerson LG Maytag Mitsubishi Motorola Samsung Sharp Siemens Yamaha Zanussi other → Top types Infotainment Musical instruments Video games & consoles other → Top brands AMI Asus Califone Campbell Hausfeld Capcom CES Excalibur Magnasonic Manta Mattel Merit MERIT INDUSTRIES Sega Silvercrest VTech other → Top types Binding machines Boards Calculators Desk accessories & supplies Dust covers Equipment cleansing kit Folders, binders & indexes Hole punches Laminators Mail supplies Office furniture Paper cutters Paper shredders Writing instruments Writing paper other → Top brands Belkin Black & Decker Brother Canon Casio Craftsman Fujitsu HP Makita Panasonic Philips Samsung Sharp Targus Tripp Lite other → Top types Baby bathing & potting Baby furniture Baby safety Baby sleeping & bedding Baby travel Feeding, diapering & nursing Toys & accessories other → Top brands AMD Breville Chevrolet Chicco Cobra D-Link Delta Denon Eton Motorola Philips AVENT Radio Shack VTech Yamaha Zebra other → Top types Pet hair clippers other → Top brands Andis other → Top types Bicycles & accessories Bubble machines Camping, tourism & outdoor Fitness, gymnastics & weight training Martial arts equipment Skateboarding & skating Smoke machines Sport protective gear Target & table games Water sports equipment Winter sports equipment other → Top brands Black & Decker Carrier Chauvet Coleman CYBEX Daikin Emerson Epson Morphy Richards Pro-Form ProForm Sears Weider Weslo York other → Top types Bedding & linens Cleaning & disinfecting Do-It-Yourself tools Domestic appliances Home décor Home furniture Home security & automation Kitchen & houseware accessories Kitchenware Lighting other → Top brands Baumatic Bosch Char-Broil Cuisinart DeLonghi Electrolux Franke Hama KitchenAid Miele Panasonic Philips Siemens Smeg Tristar other → Top types Hot beverage supplies other → Top brands other → Top types Bags & cases Children carnival costumes Clothing care Clothing hangers Dry cleaners Fabric shavers Men's clothing Tie holders Ultrasonic cleaning equipment Watches Women's clothing other → Top brands Braun Grundig Mitsubishi Electric Olympia Omega Philips Sencor SEVERIN Shark Solac Termozeta Timex V7 Velleman Wenger other → Upload 1. No category Silcon Technical Specs - Detailed.doc SECTION 16611 STATIC UNINTERRUPTIBLE POWER SUPPLY PART 1 GENERAL 1.01 SUMMARY This specification describes a three-phase, on-line, continuous operation, solid-state uninterruptible power supply (UPS). The UPS shall operate as a active power control system, working in conjunction with the existing building electrical system to provide power conditioning, and on-line power protection for the critical loads. 1.02 SYSTEM DESCRIPTION A. Modes of operation: The UPS shall operate as an on-line system in the modes listed below. Normal: The main inverter and the delta inverter shall operate in an online manner to continuously regulate the power to the critical load. The delta inverter and main inverter also shall derive power from the AC input source and supply DC power to float charge the battery. Battery: Upon failure of the AC input source, the critical load shall continue being supplied by the main inverter without any switching. The inverter shall obtain its power from the battery. There shall be no interruption in power to the critical load upon failure or restoration of the AC input source. Recharge: Upon restoration of the AC input source, the delta inverter and main inverter shall simultaneously recharge the battery and regulate the power to the critical load. Bypass: The static bypass switch shall be used for transferring the critical load to mains supply without interruption. Automatic re-transfer to normal operation shall also be accomplished with no interruption in power to the critical load. The static bypass switch shall be capable of manual operation. External maintenance bypass [optional]: The external maintenance bypass switch shall be used for supplying the load directly from the mains supply, while the UPS is isolated for maintenance. 1. 2. 3. 4. 5. B. Future expansion: The UPS shall be capable of field-up-grade to allow parallel operation with additional UPS modules for increased capacity or for redundant operation. The parallel systems shall be capable of operation on a common DC bus or with a separate DC bus for each system module and shall provide proportional load sharing between all available modules. To provide a true fault tolerant control system, any individual UPS module shall be capable of automatically assuming control of the entire system. [The ability to expand system capacity for future requirements means that the entire UPS system does not have to be replaced each time the load requirements expand beyond the UPS system’s power rating. The ability to operate in a redundant configuration is important for applications where even momentary exposure to utility power (such as during maintenance) is to be avoided. Redundant systems assure no possible single points of failure.] 1.03 STANDARDS A. Safety: 1. USA/Canada: UL Listed to UL1778 - Standards for Uninterruptible Power Supply Equipment. cUL Listed to CSA 2. Europe: En 50091-1 B. Emission and Immunity: 1. 2. USA/CANADA: FCC Class A Europe: EN 50091-2 C. CE-Mark. 50 Hertz Models 1.04 SUBMITTALS A. Proposal submittals: 1. 2. 3. 4. 5. 6. 7. As bid system bill of materials. Product catalog sheets or equipment brochures. Product guide specifications. System single-line operation diagram. Installation information, including weights and dimensions. Information about terminal locations for power and control connections. Drawings for requested optional accessories. B. 2. Delivery submittals: Submit [____] of the following: Installation manual which includes instructions for storage, handling, examination, preparation, installation, and start-up of the UPS. User manual which includes UPS operating instructions. 1.05 QUALIFICATIONS A. Manufacturer experience: The manufacturer shall have a minimum 25 years of experience in the design, manufacture, and testing of UPS systems. B. ISO 9001 Certification: The manufacturer shall be ISO 9001 certified. 1. [ISO 9001 certification assures that the vendor’s quality system has been certified by an accredited registrar and meets internationally recognized standards.] 1.06 Environmental requirements: A. Storage ambient temperature: -58F to 131F (-50C to 55C). B. Operating ambient temperature: 32F to 104F (0C to 40C). (68F to 77F (15C to 25C), ideal for batteries). C. Relative humidity: 0 to 95%, non-condensing. 1.07 WARRRANTY A. 1. UPS module: The UPS manufacturer shall warrant the UPS module against defects in workmanship and materials for 1 year from the date of retail sale or the date of delivery to the initial user, whichever occurs first, however not exceeding 18 months from date of delivery. The warranty shall include coverage of all internal parts, including internal batteries. B. 1. External Batteries: For batteries connected to the UPS, the battery manufacturer’s standard warranty must be passed through to the end user. PART 2 PRODUCT 2.01 MANUFACTURER American Power Conversion: APC Silcon DP300E System. 2.02 SYSTEM CONFIGURATION Initially provided as a [single module][multiple module], [nonredundant][redundant] system, the UPS shall be field-upgradable for additional capacity or for redundant operation. 2.03 SYSTEM RATINGS AND OPERATING CHARACTERISTICS A. System continuous rating: [____] kVA, [____] kW at unity power factor. [Choose one (kVA = kW): 10; 15; 20; 30; 40; 60; 80; 120; 160; 240; 320; 400; 500; or specify other rating. Contact APC for other rating options] B. Battery capacity: The system must be capable of providing [____] minutes of battery back-up time at a [____] kW load. [Typically battery runtimes are specified at .8 power factor, F.ex. battery kW load = kVA * .8pf If you are specifying internal batteries select from the following based on the UPS kVA rating:] [10kVA = 22 minutes 7kW] [20kVA = 8 minutes 14kW] [40kVA = 8 minutes 28kW] [15kVA = 13 minutes [30kVA = 13 minutes 10.5kW] 21kW] C. Input voltage rating: [208*] [480] volts, ground. three-phase, four-wire plus D. Input voltage range: +15%, -15%. E. Input frequency: 60 Hz +/- 6% (other levels programmable). F. Magnetizing inrush current: NONE, if optional input isolating transformer is installed then 500% of nominal input current for less than one cycle. G. Power walk-in: 0 to 100% over a 10-second period (longer duration programmable). H. Input power factor: Min. 0.93 lagging on 25% load. Min. 0.99 lagging on 100% load. I. Input current distortion: 5% THD maximum at full rated load and nominal input voltage without additional harmonic filters. [A UPS system with low input distortion has minimal impact on the customer installation, particularly on sites with a diesel generator back-up.] J. Output voltage rating: [208*] [480] volts, three-phase, four-wire plus ground. [Note: This shall be the same as input voltage rating, see paragraph C.] K. Output voltage regulation (at default parameter settings): 1. +/- 1% steady state for a static 100% balanced load. 2. +/- 3% steady state for a static 100% unbalanced load. 3. +/- 5% for a 0 to 100% load step. L. Output frequency: 60 Hz +/- 0.1 Hz free running (battery operation). Mains synchronized in normal operation. M. Output power factor range: 0.9 leading to 0.8 lagging at rated kVA. The unit’s kVA capacity shall not require derating for a 1.0 load power factor. [Full unit kVA capacity at a 1.0 load power factor assures system compatibility for power factor corrected (PFC) loads.] N. 1. 2. 3. Output harmonic distortion: 3% THD maximum and 1% any single harmonic for a 100% linear load. 5% THD maximum for a 100% non-linear load (no crest factor limit), UPS 1060kVA and 120-500kVA. 6% THD maximum for a 100% non-linear load, (no crest factor limit), UPS 80kVA. O. 1. 2. Voltage transient response: +/- 3% for a 50% load step. +/- 5% for a 100% load step. P. Voltage transient recovery time: 50 milliseconds. Q. 1. 2. 3. Phase displacement: 120 degrees +/- 1 degree for balanced load. 120 degrees +/- 1 degree for 50% unbalanced load. 120 degrees +/- 3 degrees for 100% unbalanced load. R. 1. 2. 3. 4. 5. Overload capability: 200% for 60 seconds in normal operation. 125% for 10 minutes in normal operation. 150% for 30 seconds in battery operation. 125% continuously in bypass operation. 1000% for 500 milliseconds in bypass operation. [High UPS overload capability is important to ensure that the UPS system does not fail to protect the load during system start-up and intermittent load operations (such as motor on/off cycles or faulted overcurrent protection devices).] S. Short circuit withstand: The UPS must withstand a bolted-fault short circuit on the output without damage to the UPS module. [This capability means that the UPS system will not catastrophically fail even under the most adverse load conditions.] T. System AC to AC efficiency: [____]% at 100% linear load, nominal input voltage, with batteries fully charged. [Choose, depending on the input/output voltage and unit kVA/kW rating: 208V 10 15 20 30 40 60 80 kVA/kW kVA/kW kVA/kW kVA/kW kVA/kW kVA/kW kVA/kW = = = = = = = 93.6% 93.6% 94.5% 94.7% 95.0% 94.9% 95.1% 480V 10 kVA/kW = 94.3% 15 kVA/kW = 94.3% 20 kVA/kW = 94.9% 30 kVA/kW = 94.3% 40 kVA/kW = 95.0% 60 kVA/kW = 94.1% 80 kVA/kW = 95.1% 120 kVA/kW = 94.5% 160 kVA/kW = 95.8% 240 kVA/kW = 95.1% 320 kVA/kW = 95.8% 400 kVA/kW = 95.4% 500 kVA/kW = 95.9%] [High system operating efficiency results in an attractive overall costofownership profile and minimal UPS impact on the facility (i.e. air conditioning requirement).] U. Acoustical noise: dB(A) of noise, typical, measured at 1 meter from the operator surface: 70% load: [10kVA: 55 [15kVA: 55 [20kVA: 55 [30kVA: 55 [40kVA: 55 [60kVA: 65 [80kVA: 65 [120kVA: 69 [160kVA: 69 [240kVA: 69 [320kVA: 69 [400kVA: 69 [500kVA: 69 100% load: 10kVA: 55] 15kVA: 65] 20kVA: 65] 30kVA: 65] 40kVA: 65] 60kVA: 75] 80kVA: 75] 120kVA: 72] 160kVA: 72] 240kVA: 72] 320kVA: 72] 400kVA: 72] 500kVA: 72] [A low acoustical noise rating allows the UPS system to be placed in a normal working environment; no special equipment room is required.] 2.03 UPS DESIGN AND FABRICATION A. Mean time between failures: Field-proven minimum of 120,000 hours. B. Modular sub-assemblies: For ease of maintenance and service, the UPS must have field-replaceable modular sub-assemblies. C. Materials: All materials comprising the UPS module shall be new, of current manufacture, and shall not have been in prior service except as required during factory testing. The UPS module shall contain no PVCs. Inverter/Battery charger: The delta inverter and main inverter shall be a high-speed insulated-gate bi-polar transistor switch module type (IGBT)and shall be controlled by a pulse-width modulation technique to precisely regulate system output voltage and battery charge current. Output current limit: The main inverter shall be capable of supplying overload current of 150% of the system rating for 30 seconds. Temperature protection: The inverters shall be temperature protected. In case of inverter over temperature, the unit shall activate an alarm and automatically transfer to static bypass operation. Charging operation modes: a. Float charge: Under nominal operating conditions, the delta inverter and main inverter shall provide a precisely regulated nominal DC bus voltage (programmable). b. Boost charge: The delta inverter and main inverter shall provide a boost charge of 2.27 to 2.40 volts per cell (programmable) for a period of 1 to 24 hours (programmable). Battery charging temperature compensation: For protection of the batteries, the unit shall monitor the temperature of the batteries. To extend battery life, charge voltage must be compensated for changes in battery temperature. Battery charge current limit: The battery charging current limit must be limited to 10% of nominal DC discharge current (programmable to lower level). D. 1. 2. 3. 4. 5. 6. [The combined delta inverter and main inverter (no separate rectifier required) provides the UPS system with superior operating efficiency and low input current distortion without compromising on-line critical load protection.] E. 1. 2. 3. Static switch: The static switch shall be solid state, rated for continuous duty and be provided with it’s own dedicated, redundant power supply. The static bypass switch shall automatically transfer the critical load to mains supply without interruption after the logic senses one of the following conditions: a. Inverter overload beyond rating. b. Battery runtime expired and bypass available. c. Inverter failure. d. Battery circuit breaker open. e. Fatal error in control system. The static bypass switch shall automatically retransfer from bypass to the delta inverter and main inverter, when one of the following conditions occurs: a. After an instantaneous overload-induced transfer has occurred and the load current has returned to less than 100% of the system rating. b. The UPS delta inverter and main inverter are active (on). 2.04 BATTRY PLANT A. Battery type: [Sealed valve-regulated] [Flooded] battery cells designed for UPS high rate discharge. [Std internal batteries are sealed Valve-Regulated Lead-Acid with 5 year design life] Design Lifetime: [____] years [5] [10] [20 (optional for flooded cells only)] years. B. C. DC ripple: Max. 0.2C. [These low DC current charging characteristics meet and exceed the battery manufacturer requirements for optimum battery life.] D. Low battery voltage protection: To prevent total discharge or damage to the battery, the UPS shall transfer to standby operation when the battery voltage reaches a set minimum voltage level (programmable). If the AC input source has not returned within 10 minutes after low battery shutdown, the UPS shall electronically disconnect DC power from the battery to avoid deep discharge. E. Battery monitor: A battery monitor function shall be capable of monitoring and defining battery capacity. It shall be possible to program the unit to perform an automatic battery test every 90 days to test the condition of the battery. G. Battery manufacturing controls: Each battery cell shall be clearly identified as to cell type, voltage, and capacity. All cells in the battery have to be tested to verify 100% system capacity. The equipment shall be designed and manufactured under a quality assurance program which is controlled and documented by written policies, procedures, or instruction. H. Battery cabinet assembly: A free-standing, cabinet appearance of the UPS and is designed to allow for The battery cabinet assembly shall include battery a positive means of isolating the battery from the disconnects shall be capable of EPO operation I. Battery disconnect: For units with external batteries in racks, provide a positive means of isolating both the battery strings from the rest of the system. 2.05 DISPLAY AND CONTROLS A. Display unit: A microprocessor-controlled display unit shall be located at the front of the UPS cabinet. The display unit shall consist of an alphanumeric display with backlight, an alarm LED, and a touch keypad. B. UPS status messages: The display unit shall display the following UPS status messages: Normal operation: load power xxx%. Battery operation: time xxx minutes. 1. 2. that complements the ease of maintenance. disconnects to provide rest of the system. The 3. 4. 5. Bypass operation. Standby. System off C. Metered parameters: The display unit shall allow the user to display the following metered parameters: 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. Year, Month, Day, Hour, Minute, Second Mains Input AC voltage (line-to-line, three-phase simultaneous). Mains Input AC current (line-to-neutral, three-phase simultaneous). Output AC voltage (line-to-line, three-phase simultaneous). Output AC current (line-to-neutral, three-phase simultaneous). Output frequency. Battery voltage. Battery current (charge/discharge). Battery temperature. Output peak current. D. Alarms: The display unit shall allow the user to display a log of all active alarms. A minimum of 50 alarm conditions shall be monitored. E. Events log: The display unit shall allow the user to display a time- and date-stamped log of the 250 most recent UPS status and alarm events. F. Controls: The following control or programming functions shall be accomplished with the display unit: 1. 2. Silence an audible alarm. Set the alphanumeric display language to English or the alternate language. Display or program the time and date. Enable or disable the automatic restart feature. Transfer to or from static bypass operation. Program the unit for economy operation. Program the battery charger. Calculate battery back-up time. Test battery condition on demand. Program the unit to periodically test battery condition. Program voltage and frequency windows. Calibrate metered parameters. Enable or disable adaptive slew rate. Set maximum slew rate. Adjust set points for different alarms. Program the remote shutdown contact (enable/disable remote shutdown, polarity, delay). Set the delay for the common fault contact. Program the unit for soft start for use with a generator. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. G. UPS On and Off push buttons: Momentary UPS on and off push buttons shall be provided in a user-accessible compartment. Upon activation of the on push button, the UPS shall automatically connect the UPS output to the critical load. Upon activation of the off push button, the UPS shall remove power from the critical load. H. Potential free contacts: The UPS shall be equipped with two potential free contacts: Common fault alarm. 1. 2. Battery operation. Other potential free contacts shall be available as option. I. Communication interface board: A communication interface board shall provide the following communication ports, and it shall be possible to use two or more ports simultaneously. RS232 serial port #1. RS232 serial port #2. COM-PORT with the following normally open or normally closed potential free contacts: a. UPS on. b. Static bypass operation. C. Battery operation. d. Battery low. 1. 2. 3. J. External maintenance bypass: The external maintenance bypass shall supply the load from the bypass source while the UPS is isolated for maintenance. A UPS input, output, and bypass switch shall be housed in the same cabinet. Each switch must be monitored by the UPS via auxiliary contacts. The maintenance bypass must be housed in a wall mounted or freestanding enclosure that complements the appearance of the UPS. K. Battery charger temperature compensation: For units with external batteries, the battery charging temperature compensator shall monitor the temperature in one battery cabinet. L. Remote UPS monitoring kits: Remote UPS monitoring shall be possible via either RS-232 or contact closure of the UPS and an existing computer system. The UPS manufacturer shall have available interface kits to support remote monitoring for the following systems: systems: a. Microsoft Windows 3.1, 3.11 b. Microsoft Windows 95 c. Microsoft Windows NT d. OS/2 e. Netware 3.12, 4.1, 4.11 f. Apple d. DEC VMS g. DG-UX h. Silicon Graphics i. DEC OSF/1 j. SCO UNIX k. SCO XENIX l. SVR4 m. Interactive n. Unix Ware o. SUN Solaris p. SUN OS q. IBM AIX r. HP-UX M. SNMP adapter: The Ethernet/Token Ring SNMP adapter shall allow one or more network management systems (NMS) to monitor and manage the UPS in TCP/IP network environments. The management information base (MIB) shall be provided in DOS and UNIX tar formats. The SNMP interface adapter shall be connected to the UPS via the RS232 serial port on the standard communication interface board. N. Parallel operation: UPS modules shall be capable of running in parallel operation for increased capacity or for redundant operation. The parallel board shall ensure proper control of parallel units and proper load sharing. One parallel board shall be provided for each unit connected in parallel. MECHANICAL DESIGN: A. Enclosure: The UPS shall be housed in a freestanding enclosure. The enclosure shall be designed to blend into a computer room environment. The cabinet shall be equipped for fork truck lifting. The UPS cabinet shall be painted with the manufacturers standard color. All service access shall be from the front and top for 10-40kVA. 60kVA – 500kVA models require front access for field wiring terminations. B. UPS module dimensions: Height x Width x Depth. [Choose one, depending on UPS kVA/kW rating and input/output voltage: 10kVA/kW 208V/480V= 15kVA/kW 208V = 15kVA/kW 480V = 20kVA/kW 208V = 20kVA/kW 480V = 30kVA/kW 208V/480V = 40kVA/kW 208V/480V = 60kVA/kW 480V = 60kVA/kW 208V = 80kVA/kW 480V = 80kVA/kW 208V = 120kVA/kW 480V = 160kVA/kW 480V = 240kVA/kW 480V = 320kVA/kW 480V = 400kVA/kW 480V = 500kVA/kW 480V = C. 55.12 55.12 55.12 55.12 55.12 55.12 55.12 55.12 59.06 55.12 59.06 70.87 70.87 70.87 70.87 70.87 70.87 x x x x x x x x x x x x x x x x x 23.62 39.37 23.62 39.37 23.62 39.37 39.37 39.37 39.37 39.37 39.37 62.99 62.99 74.80 74.80 94.49 94.49 x x x x x x x x x x x x x x x x x 31.50 31.50 31.50 31.50 31.50 31.50 31.50 31.50 31.50 31.50 31.50 31.50 31.50 31.50 31.50 31.50 31.50 in. in. in. in. in. in. in. in. in. in. in. in. in. in. in. in. in. (1400 (1400 (1400 (1400 (1400 (1400 (1400 (1400 (1500 (1400 (1500 (1800 (1800 (1800 (1800 (1800 (1800 x x x x x x x x x x x x x x x x x 600 x 800 mm); 1000 x 800 mm); 600 x 800 mm); 1000 x 800 mm); 600 x 800 mm); 1000 x 800 mm); 1000 x 800 mm); 1000 x 800 mm); 1000 x 800 mm); 1000 x 800 mm); 1000 x 800 mm); 1600 x 800 mm); 1600 x 800 mm); 1900 x 800 mm); 1900 x 800 mm); 2400 x 800 mm); 2400 x 800 mm); Ventilation: The UPS shall be cooled by forced air and shall be equipped with fan monitoring circuits. External battery systems shall be cooled by free-air ventilation and convection. Part 3 EXECUTION 3.01 FACTORY ASSISTED START-UP [Optional] If a factory assisted UPS start-up is requested, factory trained service personnel shall perform the following inspections, test procedures, and on-site training: A. 1. 2. 3. 4. 5. Visual Inspection: Inspect equipment for signs of damage. Verify installation per manufacturer s instructions. Inspect cabinets for foreign objects. Verify correct electrolyte level of flooded cells (if applicable). Inspect battery cases. 6. 7. Inspect batteries for proper polarity. Verify all printed circuit boards are properly configured. B. 1. Mechanical Inspection: Check all UPS, external maintenance bypass cabinet, and DC disconnect switch internal control wiring connections. Check all UPS, external maintenance bypass cabinet, and DC disconnect switch internal power wiring connections. Check all UPS, external maintenance bypass cabinet, and DC disconnect switch terminal screws, nuts, and/or spade lugs for tightness. 2. 3. C. 1. 2. 3. 4. 5. 6. 7. Electrical Inspection: Check all UPS fuses for continuity. Verify correct input and bypass voltage. Verify correct phase rotation. Verify correct UPS control wiring and terminations. Verify correct termination and voltage of battery strings. Verify neutral and ground conductors are properly configured. Inspect external maintenance bypass switch for proper terminations and phasing. D. 1. 2. 3. 4. 5. 6. 7. 8. 9. Site Testing: Ensure proper system start-up. Verify proper firmware control functions. Verify proper firmware bypass operation. Verify proper maintenance bypass switch operation. Verify system set points. Verify proper inverter operation and regulation circuits. Simulate utility power failure. Verify proper charger operation. Document, sign, and date all test results. E. On-Site Operational Training: During the factory assisted start-up, operational training for site personnel shall include key pad operation, LED indicators, start-up and shutdown procedures, maintenance bypass and AC disconnect operation, and alarm information. 3.02 MANUFACTURER FIELD SERVICE A. Worldwide service: The UPS manufacturer shall have a worldwide service organization available consisting of factory trained field service personnel to perform start-up, preventative maintenance, and service of the UPS system and power equipment. The service organization shall offer a 24 hours a day, 7 days a week, 365 days a year service support. B. Replacement parts: Parts shall be available through the worldwide service organization 24 hours a day, 7 days a week, 365 days a year. The worldwide service organization shall be capable of shipping parts within 4 working hours or on the next available flight, so that the parts may be delivered to the customer site within 24 hours. 3.03 MAINTENANCE CONTRACTS A complete offering of preventative and full service maintenance contracts for the UPS system and the battery system shall be available. Contract work shall be performed by factory trained service personnel. 3.04 TRAINING UPS service training workshop: A UPS service training workshop shall be available from the UPS manufacturer. The service training workshop shall include a combination of lecture and practical instruction with hands-on laboratory sessions. The service training workshop shall include instruction about safety procedures, UPS operational theory, sub-assembly identification and operation, system controls and adjustment, preventative maintenance, and troubleshooting. Open as PDF Similar pages StruxureWare Data Center Expert 7.2.1 Release Notes Tripp Lite SmartOnline 120kVA Modular 3-Phase UPS System, On-line DoubleConversion International UPS Building Management Integration Card H-Series-3 Specifications PDF MGE Galaxy 5000 40-130 KVA PW 9315 400kVA American Power Conversion AP9615 Switch User Manual Catalogo UPS Trifase Wise33 WiseMP33 ZERO CURRENT/ VOLTAGE CROSSING AUTOMATIC VOLTAGE STABILIZER UPS Out-of-Band Management Card Manual Installation Product Overview Site Planning manualzz © 2017 ProjectZZ About us DMCA Abuse here