Download Multiple Cell Formation and Testing

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts
no text concepts found
Transcript
ENGLISH
Multiple Cell Formation and Testing
* Technical data and images may reflect optional equipment and are subject to change without notice.
Switch Mode Bidirectional Design
System
with 1024
circuits
Suitable for pilot line to mass production
Scalable system designed to form
or test cells from 0.5 – 5.5V
2A charge / discharge per circuit
High packing density – One thousand
circuits per square meter
Energy-efficient switch mode amplifiers
Energy recuperation by bidirectional
power supply
Ŷ TECHNICAL DATA*
Multiple Cell Formation & Testing
MCFT-BD
Ŷ DC DATA
Max. circuits per installation
Paralleling of circuits
Voltage range
Max. current per circuit
Max. power per circuit
Accuracy VDC
Accuracy ADC
unlimited**
yes
0.5V – 5.5V
2A
11W
< ± 0.025% FSR
< ± 0.05% FSR
Resolution U, I
Current rise time (10 – 90%)
Transition time charge/discharge
Data Acquisition Rate (DAR)
Energy recuperation
Cylindrical cell fixture
16 bit
≤ 1ms
≤ 1ms
100ms
regenerative DC-Link
Other current and voltage ranges available on request.
Ŷ AC DATA
wide range supply
≥ 0.99
< 5%
92%
yes
Mains connection
Rated power-factor
THD
Max. efficiency
Galvanic isolation to mains
DB37 cell connectors
(Agilent pin-compatible option)
Ŷ COOLING, ENVIRONMENTAL CONDITIONS
Cooling
Ambient temperature, operating
Humidity
forced air ventilation
5° – 45°C (41° – 113°F)
10% - 90% RH, non-condesing and noncorroding
Ŷ MODULE GENERAL DATA
Circuits per power module
32 – 64
Superior reliability by distribution of amplifiers across multiple CPUs
Protection level
IP20
Dimensions width, height
19” 3U
Ŷ OPTIONS & ACCESSORIES
Switchable current ranges
2A, 1A, 500mA, 250mA
Inverter for line regenerative discharge
Cell contacting fixtures for cylindrical, pouch, or prismatic cells
Pin-compatible with Agilent E4374A and E4375A
Software for formation, grading,
and laboratory
* Technical changes reserved.
rev300516
**dependant on hardware and software configuration
Aachen, Germany
+49 241 168 090
 +49 241 168 0919
 [email protected]
www.digatron.de

Shelton, (CT), USA
 +1 203 446 8000
 +1 203 446 8015
 [email protected]
www.digatron.com
Qingdao, China
 +86 532 8608 9988
 +86 532 8608 9909
 [email protected]
www.digatron.com
Pune, India
 +91 20 27472532
 +91 20 27475817
 [email protected]
www.digatron.com