TB - Test Bench for Motors and
Generators
CINERGIA provides customized power electronic equipment
combined with mechanical systems for R&D laboratories and
manufacturers of electrical motors and generators.
7.5 kVA - 200 kVA
Regenerative function
Different motor couplings
available
Torque setpoints
Functional description
CINERGIA Test Benches allow testing motors and commercial
drives.
The control system can be done with our cards based in a TI
DSP or using real-time simulation systems.
They also enable the development and emulation of highlevel control algorithms for control of wind power systems
with HVDC power transmission.
The test bench is commanded via torque setpoints
introduced by the user.
The converter is based on a hardware topology allowing a
bidirectional power flow providing energy savings. This
regenerative functionality allows the use of the equipment in
applications where the test needs long time to stabilization.
Different options:
Induction motors Test Bench
Brushless motors Test Bench
Flywheel Test Bench
Applications:
TB - Test Bench for Motors and Generators
o
o
o
o
Motor test
Drive test
Powertrain test
Wind turbine test
www.cinergia.coop
1
TB - Test Bench for Motors and
Generators
Technical Diagram
Main test bench specifications
Rated Power:
Rated AC Voltage Vac:
Rated DC Voltage Vdc:
Rated current Iac:
Commutation Frequency fsw:
7.5-200kVA
0-480Vrms(max)
0-750Vdc (max)
230Arms (max)
15kHz (max)
TB - Test Bench for Motors and Generators
Induction motors Test Bench
www.cinergia.coop
2
TB - Test Bench for Motors and
Generators
Brushless motors Test Bench
TB - Test Bench for Motors and Generators
Flywheel Test Bench
www.cinergia.coop
3
TB - Test Bench for Motors and
Generators
Measurements options
Magnitude
Measurements
User interface (options)
Protections
Value
Input Voltage (Vrms) and Current (Irms)
Active and Reactive Input Power (P,Q)
Output Voltages (Vrms) and Currents (Irms)
Output Power
Temperatures
3.2” Touchscreen
Control port: 3 analog inputs/outputs, 5 inputs, 3 relay outputs
Communication Ports: Ethernet, RS485
Communication Protocols: Modbus/TCP
Customized communications for IEC61850, ERP or MATLAB®
Over Current
Shortcircuit
Over Voltage
Over temperature
TB - Test Bench for Motors and Generators
TB models
Model
Reference
TB_7
TB_10
TB_15
TB_20
S (Power)
7.5kVA
10 kVA
15 kVA
20 kVA
Regenerative
Current
±10A
±15A
±20A
±25A
TB_30
TB_40
TB_50
TB_60
TB_80
TB_100
TB_120
TB_160
TB_200
30 kVA
40 kVA
50 kVA
60 kVA
80 kVA
100 kVA
120 kVA
160 kVA
200 kVA
±40A
±50A
±65A
±80A
±105A
±130A
±155A
±185A
±230A
www.cinergia.coop