Survey
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
First Results from the First G-APD Cherenkov Telescope Adrian Biland, ETH Zurich for the FACT Collaboration: TU Dortmund, U Geneva, EPF Lausanne, U Wuerzburg ETH Zurich The FACT Project Key Question: can newly developed Si-based photosensors [G-APD, SiPM, MPPC,…] be used in Cherenkov Telescopes ? - reduction of operation complexity (less fragile, no HV) - stable remote operation - eventually lower cost and higher efficiency by profiting from development for large market for Si-based technology Main Problem: PMTs and G-APD have rather different features ==> 'difficult' to compare datasheets Solution: Build a CT using these new photosensors and try ==> First G-APD Cherenkov Telescope [email protected] FACT ICRC 2011, Aug 17, Beijing 2 Prototype Results (2009) [email protected] FACT ICRC 2011, Aug 17, Beijing DRS-2 with known cross-talk problems two additional PMT in +/-7m distance 3 Prototype Results (2009) Final proof that self-triggered measurements of Cherenkovshowers feasible with G-APD Next step: build real telescope [email protected] FACT ICRC 2011, Aug 17, Beijing 4 Refurbished HEGRA-CT3 Telescope at La Palma: - new mirrors installed (refurbished from CT1) - new drive system installed - new container as 'counting house' - awaiting camera …. Aug 17,2Beijing 9.2m2 [email protected] mirror area (next toFACT MAGIC ICRC with2011, 2x 236m mirror…) 5 FACT Camera Tests at ETH Zurich integrated ~40cm ~200kg ~1kW 1440Pixels [email protected] FACT electronics ICRC 2011, Aug 17, Beijing 6 The FACT Project Poster T.Bretz 1132 Main Components: - Refurbished HEGRA CT3 telescope at LaPalma (9.2m2 mirror area, f/d = 1.4, new drive system) Camera: - G-APDs (HAMAMATSU MPPC S10362-33-050C) - Solid Light-Concentrators Poster B. Huber 0136 - Electronics (DRS-4 based) in camera Talks P. Vogler 0389, T. Kraehenbuehl 0529 - readout using standard ethernet [email protected] FACT ICRC 2011, Aug 17, Beijing 7 G-APD Basics Geiger-mode Avalanche Photodiode: (also called: SiPM, MPPC, PPD, …) Pixelized Si-based photosensor: a (single) photon hiting a cell has some probability to create a 'breakdown' -> always same signal Many small cells ==> total signal analogue sum of the isochronous single-cell signals cell-sizes: 100x100 µm2 better PDE 50x 50 µm2 better NSB [email protected] FACT ICRC 2011, Aug 17, Beijing 3x3mm8 2 Why Solid Light Concentrators Liouville theorem: can not shrink phase-space Area <----> Angular Distribution FACT: ~80mm2 9.0mm2 (7.8mm2) ==> Solid cones allow higher area-concentration! (important for small photosensors with high cost/mm2) [email protected] FACT ICRC 2011, Aug 17, Beijing 9 Why Solid Light Concentrators In case of sealed camera: less Fresnel reflection needs 'perfect' optical coupling ==> glue but: absorption ==> do not want too large G-APD area Can use inexpensive casting (UV transparent PMMA) Complicated shapes possible (FACT: square -> hexagon) [email protected] FACT ICRC 2011, Aug 17, Beijing 10 Solid Cone Problems Too high pressure during casting reduces overall transmission (also micro-bubbles) Tedious and time consuming glueing minor PMMA inpuritiesFACT destroyICRC UV transmission [email protected] 2011, Aug 17, Beijing 11 FACT Status - Telescope: Ready - Camera: - Hardware: Ready (1435 Pixel ok, 2 dead, - Firmware: operational - Control Software: operational 3 strange) Tests of full camera going on … [email protected] FACT ICRC 2011, Aug 17, Beijing 12 Recent Test Results Random-Trigger ==> Dark Counts [email protected] FACT ICRC 2011, Aug 17, Beijing x 0.5ns 13 Recent Test Results Random-Trigger ==> Dark Counts 1 cell == 1 photo-electron (~10mV) [email protected] FACT ICRC 2011, Aug 17, Beijing x 0.5ns 14 Recent Test Results Random-Trigger ==> Dark Counts 2 cells == 2 photo-electrons -> cross-talk 1 cell == 1 photo-electron (~10mV) [email protected] FACT ICRC 2011, Aug 17, Beijing x 0.5ns 15 Recent Test Results 1 p.e. @ room temp. 2 p.e. very simple pulse extraction (not taking into account e.g. known pulse shape) ==> all pix. very similar 3 p.e. 4 p.e. ~5MHz dark counts <10% cross-talk Sum of 1435 Pixels without (ADC) calibration!! [email protected] FACT ICRC 2011, Aug 17, Beijing 16 Recent Test Results Illuminating camera with test-pulse: ==> All pix. very similar (without (ADC) calibration) Arrival-time distrib. <0.5ns (rms) !!! (without calibration !!!!) [email protected] FACT ICRC 2011, Aug 17, Beijing 17 Summary and Outlook - FACT camera assembled, first system tests look very promising - Will be installed in refurbished HEGRA-CT3 at La Palma this year - Gain experience with G-APDs under CT conditions [email protected] FACT ICRC 2011, Aug 17, Beijing 18 Summary and Outlook - FACT camera assembled, first system tests look very promising - Will be installed in refurbished HEGRA-CT3 at La Palma this year - Gain experience with G-APDs under CT conditions Will next generation G-APDs be better than PMTs (price, performance, …) ???? [email protected] FACT ICRC 2011, Aug 17, Beijing 19