Survey
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
1. Turbine inlet valve 1.1 Guaranteed Technical Particulars --------------------------------------------------------------------------------------------------------ITEM DESIGNATION VALUE REMARKS --------------------------------------------------------------------------------------------------------1. General 2. i) Manufacturer ii) Place of manufacture iii) Type designation Main data i) Maximum leakage from main valve when fully closed against rated head of 143 m (with new seal). a) Through seal b) Maximum leakage from bypass valve at rated head of 143 m ii) Maximum head loss through the valve at a flow required for rated turbine output at rated net head. iii) Maximum torque required to close the valve with a flow corresponding to iv) a) Rated turbine output at rated net head. b) Specified turbine overload output at rated net head. Main dimensions of inlet valve a) Inside diameter b) Length of valve body (excluding extension). c) Maximum distance from horizontal centre line of valve to lowest portion assembly. v) Lowest factor of safety (referred to design stress) for any hydraulically loaded part of the valve. vi Valve operating oil pressure. a) Minimum b) Maximum 1 1.2 Other technical particulars --------------------------------------------------------------------------------------------------------ITEM DESIGNATION VALUE REMARKS --------------------------------------------------------------------------------------------------------1 Head loss through the valve at a flow required for rated turbine output. i) At net head of 143 m. ii) 2 3 Servomotor i) Make ii) Nominal design oil pressure. iii) Active volume iv) Range of opening time. v) Range of closing time. I) Guaranteed closing time of MIV at rated load and rated head of 143 m. ii) Guaranteed closing time of MIV at over load of (110 %) and max. head of 161.447m Guaranteed maximum opening time at rated head iii) iv) 4 5 At Gross head of 161.447 m Guaranteed maximum opening time at Max.head Weight i) Weight of complete shut off valve. ii) Weight of complete oil pressure unit with pump set equipment. iii) Estimated shipping weight of valve. iv) Maximum weight of valve assembly to be handled by power house crane. Dimensions i) Minimum floor opening required for valve installation/ removal. a) Width b) Length 2 2.0 Runner 2.1.1 Guaranteed Technical Particulars --------------------------------------------------------------------------------------------------------ITEM DESIGNATION VALUE REMARKS --------------------------------------------------------------------------------------------------------1 RUNNER i) Runner ii) Material iii) No. of blades iv) Runner diameter(throat) v) Inlet diameter vi) Weight vii) Dia. at centre line of distributor (D). viii) Blade angle at inlet & outlet. ix) Runner labyrinth x) xi) 2 a) Material, standard, surface hardness (BHN). b) Method of fixing and removal of runner. Details of hard abrasion coating on a) Blades b) Labyrinths. Hydraulic flow velocity in turbine. a) Absolute at inlet. b) Peripheral at inlet. c) Relative at inlet. d) Absolute at outlet. e) Peripheral of outlet. f) Relative at outlet. Centralised grease lubrication system. i) No. of pumps. ii) Type and make of pump. iii) Capacity of grease reservoir. iv) Rating of pump. v) Number of grease distributions. vi) No. of point fed by grease vii) Frequency of lubrication. 3 viii) Recommended type and grade of grease. ix) Piping material. x) Points served by system for turbine. xi) Make of pump motors. xii) Grease consumption per cycle, per week, per month (Kg.) xiii) Rate of grease flow into turbine greasing points during application of grease (LPM). 4 3 Governing System 3. 1 Guaranteed Technical Characteristics ----------------------------------------------------------------------------------------------------Item Designation Value Remarks ---------------------------------------------------------------------------------------------------1 General i) ii) iii) 2 Manufacturer a) Control b) Hydraulic unit Place of manufacture a) Control b) Hydraulic unit Type designation a) Control b) Hydraulic unit Main data i) Sensitivity of governor to respond to min. speed change of rated speed ii) Max. dynamic pressure for total load rejection of all three turbines working in parallel on 110% load at max. net head of 143 m. iii) Max. speed rise for total load rejection of all three turbines under working conditions as per (2-ii) in percentage of rated speed iv) Governor operating oil pressure v) a) Minimum b) Maximum c) Rated Range of adjustment of gain control a) Proportional gain b) Derivative gain c) Integral gain vi) Type actuator & emergency valve type vii) Minimum wicket gate setting a) Closing b) Opening 5 3 4 5 6) 7) 8 Governor oil pumps i) Number of main oil pumps ii) Type of oil pumps iii) Unit governor oil pump discharge pressure iv) Power rating of main pump motor v) Power rating of jockey pump motor vi) Type of pressure switches Pressure accumulator i) Total oil volume ii) Design pressure iii) Minimum possible operating cycles of wicket gates (close -open) without recharging tank iv) Dimensions of tank ( H x Dia.) Sump tank i) Total oil volume ii) Size of sump (L x W x depth ) Hydraulic oil i) Total quantity of oil required for complete system including servomotors. ii) Type of governor oil Oil quantity i) Oil pressure vessels ii) Number of vessel & capacity iii) Dimensions iv) Normal working pressure v) Minimum working pressure for safe operation vi) Number of complete operations Weight of complete governor actuator cabinet with pump set equipment. 6 4.0 AVR system 4.1 Guaranteed Technical Particulars --------------------------------------------------------------------------------------------------------ITEM DESIGNATION VALUE REMARKS --------------------------------------------------------------------------------------------------------1 Manufacture 2 Place of manufacture 3 Type designations 4 Applicable standards 5 Rating of excitation system at rated generator output and rated power factor (hot rotor winding) i) field voltage ii) field current iii) field power iv) No load excitation voltage v) No load field current vi) field flashing current and duration. 6 Ceiling voltage in per units of rated field voltage. i) Ceiling voltage at no load ii) Ceiling voltage at rated load. 7 Field current at rated ceiling voltage. 8 Excitation system voltage response ratio. 9 Response time to reach 95% of the difference between rated ceiling voltage and full load field voltage. 10 Time to reach +0.5% of ceiling voltage from rated voltage. 11 Maximum time period for 7 operation at ceiling voltage power factor 0.9 and maximum generator power. 12 Data of excitation system at 110% rated generator terminal voltage, power factor 0.9 and maximum generator power. 13 i) field voltage ii) field current Maximum continuous output capability of excitation system. 14 i) maximum field current ii) maximum field voltage Maximum duration of over excitation period 15 Time to reach 5% limit of generator terminal voltage in case of load rejection 16 Maximum overshoot of generator terminal voltage in case of load rejection. 17 Setting time to reach 0.5% limit of generator terminal voltage after over speed conditions. 18 Range of voltage level setting 19 i) Range for manual control of excitation. ii) Frequency range of operation iii) % transformer drop compensation 20 Excitation transformer i) Type ii) Transformer continuous three Phase power rating. iii) Transformer voltage ratio iv) Transformer no-load losses 8 (three-phase) at rated voltage, and rated frequency. v) Vector group/ connection. vi) Transformer total losses (75oC three-phase) at full load at rated voltage and rated frequency. vii) No-load current at rated voltage and frequency. viii) Impedance voltage (75oC) at rated frequency on 100% rated kVA. ix) Transformer temperature rise after continuous operation with rated kVA, under rated conditions. - winding (by resistance) - core x) Transformer rated voltage at rated frequency and no-load. a) high- voltage b) low voltage xi) Standard applicable xii) Material a) Core b) Conductor 21 xiii) Class of insulation xiv) BIL xv) Temperature rise Voltage Regulating system. i) Make ii) Type iii) Accuracy of voltage regulation iv) Range of voltage setting. v) a) Auto mode b) Manual mode Voltage regulation from no 9 load to full load. 22 Rectifiers i) Type of rectifiers ii) Type of thyristor iii) Number of thyristor per Interchangeable module. iv) Number of modules per bridges of stacks. v) Number of bridges or stacks vi) Number of parallel paths. vii) Number of thyristor a) In series b) In parallel per path viii) Rated current of rectifier ix) Rated voltage of rectifier x) Average forward current rating per thyristor. xi) Forward voltage drop per thyristor xii) Maximum safe operating temperature. xiii) Maximum surge current rating. xiv) Max. permissible duration of surge current. xv) Cooling fans for rectifiers (if necessary) number of fans. xvi) Fan ratings. xvii) Electrical fan motor ratings a) Rated voltage b) Rated power consumption xviii) Auxiliary transformer(s) for cooling fans and other a) Ratings 10 b) Rated primary voltage c) Rated secondary voltage 23 24 Field circuit breaker i) Rated current ii) Rated voltage iii) Rated breaking current iv) Total opening time v) Total closing time vi) Operating sequence AC- field flashing equipment i) Duration of flashing ii) Power rating of field flashing transformer. iii) 25 Rated voltages of transformer a) primary side b) secondary side DC- field flashing equipment i) Power requirements ii) Supply voltage 11 5.0 Protection System 5.1 Guaranteed Technical Particulars --------------------------------------------------------------------------------------------------------ITEM DESIGNATION VALUE REMARKS --------------------------------------------------------------------------------------------------------- 1. General features A Protective devices i) Manufacturer ii) Whether entire system from same manufacture iii) Whether static type iv) Whether numeric type v) Year of commissioning of first plant with identical equipment vi) D.C. infeed : a) Supply voltage b) D.C/D.C converter included c) Tolerances of supply Voltage vii) Overload protection viii) Short-circuit protection ix) Power consumption per cubicle x) Insulation accuracy to IEC 255-A xi) Indication : a) hand reset flag b) Light emitting diodes xii) Accuracy : Time error of calibration/ repeatability 2. Protection cubicles : i) Type 12 ii) Protection class iii) Dimension (L x W x H ) iv) Maximum weight 3. Trip circuit supervision : i) Type/designation ii) Continuous/on command iii) Time delay iv) Fixed setting (approx.) v) Auxiliary elements : Hand reset vi) Supervision current 4. Max. trip circuit supervision current Test devices : i) Type/designation ii) Provided for each assembly B. Relays : 1. Differential relay : i) Type/designation ii) Current setting : a) Differential elements b) Differential current c) Bias iii) High set over current elements : Operating time : less than 3 x IN iv) Harmonic restraint : - Based on second harmonic content included 13 v) Relay Stability 2. Through – fault Stator earth fault relay : i) Type/designation ii) Voltage setting iii) Time setting 3. Over current relay : i) Type/designation ii) Setting range of time relay iii) Setting range of instantaneous element iv) Setting range of over current v) Setting range of instantaneous element 4. Over voltage relay i) Type/designation ii) Setting range of the pick-up values a) Delayed trip b) Instantaneous trip iii) Time setting range iv) Reset ratio 5. Under voltage relay : i) Type/designation ii) Definite time iii) Inverse time iv) Two setting levels v) Voltage setting : a) Setting range b) Start element reset at 14 c) Continuously variable d) Steps vi) Operating time : 6. a) Continuously variable b) Steps c) Setting range Negative phase sequence relay (46) i) Type/designation ii) Adjustable pick-up value a) First stage b) Second stage iii) Tripping time-laq adjustable 7. a) First stage b) Second stage Field Failure relay i) Type/designation ii) Setting range of pick-up generator iii) Time setting : a) First Stage b) Second Stage iv) Time integrator setting : 8. a) Pick-up b) Drop-out Reverse power relay: i) Type/designation ii) Two setting ranges iii) Pick-up range iv) Pick – up 2nd range 15 v) Maximum torque angle vi) Reset ratio vii) Direction reversible during operation viii) Operating time : 9. a) Continuously variable b) Step c) Definitive d) 1st time setting range e) 2nd time setting range Directional over-current & earth fault relay i) Type/designation ii) Setting range of time delay iii) Setting range of instantaneous element iv) Setting range of over current 10. Synchro-check relay (25) i) Type/designation ii) 2 channel device iii) Independent check on criteria (3) a) Voltage b) Power 16 6.0 24 kV Switchgear Guaranteed Technical Particulars --------------------------------------------------------------------------------------------------------ITEM DESIGNATION VALUE REMARKS --------------------------------------------------------------------------------------------------------A PANELS 1. Manufacturer’s name 2. Overall dimensions a.) Length b.) Breadth in mm. c.) Height in mm. 3. Overall weight 4. Shipping wt. Of the largest package 5. Dynamic and static load on the floor 6. Shipping dimension a.) Length b.) Breadth in mm. c.) Height in mm. B. CIRCUIT BREAKER 1. Type and make of circuit breaker 2. Place of manufacturer 3. Standard to which circuit breakers are manufactured 4. No. of phases 5. Frequency 6. Normal current capacity(Standard) 7. Derated current capacity(site) 8. Rated making capacity 9. Service voltage and system 10. Insulating media 11. Rated power frequency insulation level to earth for one minute 12. Rated power frequency insulation level to earth across open contacts for one minute 13. Rupturing capacity of circuit breaker offered MVA in mm. in mm. 17 14. Method of closing 15. Method of tripping 16. Normal voltage for operation of :a.) Closing mechanism b.) Tripping mechanism 17. Power at normal voltage for closing coil(Watts) 18. Rated impulse insulation level to earth . 19. Rated insulation level to earth across open contacts 20. Nominal pressure/vacuum bar (if applied) 21. Making capacity peak current KA 22. Breaking capacity 23. 24. 25. a.) Symmetrical KA b.) Asymmetrical KA Short time currents a.) One sec. KA b.) Three sec. KA Operating time from the instant trip coil received its tripping impulse to the instant at which the contacts separates. a.) Without current(Seconds) b.) For given breaking current(Seconds) i.) 10% ii.) 30% iii.) 60% iv) 100% v.) Short circuit Arc duration from from separation of arcing contacts to instant of arc extinction stated for breaking currents of no. of loops at :i.) 10% short circuit ii.) 30% short circuit iii.) 60% short circuit iv.) 100% short circuit 18 26. Time for closing of contact switch to complete of closing stroke with rated making current including closing of series break if any (sec.) 27. Nos of current interrupting breakers in series per phase 28. Speed of break (100%) S.C. current 29. Type of a) Main contacts b) Arcing contacts 30. Type of arc control device 31. Type of device ,if any to limit rate of rise of re-striking voltage 32. High voltage test on completely assembled circuit breaker a) 50 HZ test voltage of 1 min. KV. b) Impulse test with stand voltage on 1/50 KV full wave 33. Minimum clearance in air a) b) Between phases Line parts to earth 34. Watts and voltage of operating mechanism 35. Surface protection and the metal enclosure. a)From inside b) 36. From out side. a) Year when the first vacuum circuit breaker was put in commercial service b) Nos .of years the particular design of the circuit breaker offered has been in service. 37. Dimension of switchgear. 38. Total weight of the switchgear. 39. Max. Nos of opening and closing operation which can be performed at 100% making and breaking capacity 40. D.C. supply for panel 19 41. Capacitive switching of the equipment. 42. Earth quake loading at o.5g in all directions and dynamic forces of C.B. (C) P.T. 1. Name of manufacturer 2. Type (Please mention whether electro-magnetic or capacitive voltage trf. Etc.) 3. Rated primary voltage 4. Rated secondary voltage/ voltages 5. Rated out put per phase. 6. Rated frequency in HZ. 7. Standard values of rated voltage factor 8 Limits of temp. rise. 9. one min. power frequency with stand test voltage in KV. (rms) 10. 1.2/50 micro sec. impulse withstand voltage test in KV.( Peak) 11. Total weight (Kg) 12. Limits of voltage error and phase displacement in 5% 13. Error angle 14. Voltage error 15. Accuracy class 16. Voltage factor and rated time 17 Test to be conducted by the manufacturer at works/site (D) a) Type testes b) Routine test C.T. ( Particulars for different groups of C. T. be given on separate sheet ). 1. Name of manufacturer 20 2. Type 3. Manufacturer type designation 4. Rated voltage 5. Normal continuous rating 6. Normal ratio of transformations 7. Rated primary current 8. Rated secondary current 9. One sec. over current factor time rated current 10. Rated current dynamic ( Peak value) in amp. 11. Rated continuous thermal current temperature rise over ambient in centigrade 12. one min. power frequency dry with stand test voltage in KV. (rms) 13. one min. power frequency wet with stand test voltage in KV. (rms) 14. 1.2/50 micro sec. impulse withstand test voltage in KV. ( Peak) 15. one min. power frequency with stand test voltage on secondary in KV. (rms) 16. Max. front of wave spark over voltage 17. Magnetizing curve of CT cores 18. Mounting details 19. Overall dimensions 20. Test proposed by the manufacturer at work at site (E) i) Type test ii) Routine test LIGHTNING ARRESTOR 1. Name of manufacturer 2. Type 3. Rated voltage 4. Frequency 21 5. Nominal discharge voltage 6. Max. 100%, 1.2/50 micro impulse spark over voltage 7. Max. Power frequency with stand voltage 8. Max. front of wave spark over voltage 9. Max. residual voltage 10. L.A. standard adopted 11. Total weight (Kg) 12. Mounting details 13. Overall dimensions 22 7.0 LTAC Board Guaranteed Technical Particulars --------------------------------------------------------------------------------------------------------ITEM DESIGNATION VALUE REMARKS --------------------------------------------------------------------------------------------------------A Panels i. Panel manufacturer name ii. Type of the current iii. Rated operational voltage iv. Rated insulation voltage v. Limits of operation vi. Rated voltage of auxiliary circulation vii. Short circuit rating viii. Degree of protection ix. Service conditions i.e. indoor or outdoor x. Overall dimensions of panel a Length b Height c Breath xi. Shipping dimensions:- a Length b Breadth c Height xii. Weight of panel xiii. Shipping weight of largest package B POWER CONTACTORS : Name of manufactures Manufacturer’s type designation 23 i. RATINGS: Number of poles ii. Rated operational voltage iii. Normal current iv. Rated insulation voltage C CONSTRUCTIONAL FEATURES: i) Type and material of main contacts. ii) Type and material of arcing contacts and /or control devices. iii) a) Overall dimensions: Length b) Breadth c) iv) Height Shipping dimensions: a) Length b) Breadth c) Height CURRENT TRANSFORMERS a) Name of manufacturer and manufacturer’s type designation. b) Rated voltage c) Frequency d) The rated primary and secondary current e) Rated output f) Accuracy class g) Highest system voltage h) Rated insulation level i) j) Rated short time thermal current with rated time. Rated dynamic current k) Resistance of secondary winding 24 l) Accuracy limit factor m) Exciting current n) Instrument security factor o) Class of insulation a) The following type test certificates shall be enclosed:Short time current tests. b) Temperature rise test. c) Power frequency withstand tests on primary and secondary windings. POTENTIAL TRANSFORMERS:- a) Name of manufacturer and manufacturer’s type designation b) The rated primary and secondary voltage c) Rated frequency d) Rated output e) Accuracy class f) Highest system voltage g) Rated voltage factor and corresponding rated time h) Single phase or three phase i) No. of phases and method of connection j) k) Type of transformers (earthed or unearthed) Class of insulation The following type test certificates shall be enclosed a) Power frequency withstand test on primary and secondary windings b) Temperature rise test. MOULDED CASE CIRCUIT BREAKERS: Name of manufacturer and manufacturer’s type designation 25 i) RATING: No. of poles ii) Rated operational voltage iii) Normal current iv) Frequency v) Short circuit performance category vi) Rated short circuit breaking capacity vii) Rated short circuit making capacity viii) Rated short circuit withstand current (1 second) ix) Rated insulation voltage x) Normal rating at 40 0C ambient temp. b) De-rating for 500C ambient temp. xi) Overload and short circuit release a) Whether thermal overload adjustment provided and its range of adjustment. b) Whether magnetic short circuit protection adjustment provided and its range of adjustment. c) Definite time lag. d) Total operating time for complete clearance of fault. The following test certificates to be enclosed:- i) Test certificate for P-2 category test ii) Test certificate for mechanical life. iii) iv) Certificate or report of short circuit breaker is fitted with making current release. Whether the breaker is trip free. v) Weight of the circuit breaker. vi) Overall dimensions of the breaker (attach dimensional drawings) 26 i) ii) OPERATING PARTICULARS: Opening time Arc durations to be stated for the breaking current. OVERCURRENT AND EARTHFAULT RELAYS: Name of manufacturer and manufacturer’s type designation. RATING:- i) No. of over current relays per circuit breaker. ii) No of earth fault relays per circuit breaker. iii) Current ratings iv) Settings range v) Pick up current (% of set value) vi) Operating current *% of set value) vii) viii) Drop out current (% of set value) Time settings ix) x) Burden on C.T. at various settings C.T. requirements xi) Thermal ratings xii) Accuracy xiii) Auxiliary units and operation indicators. xiv) Coil ratings of auxiliary units and its burden xv) Contact ratings xvi) Insulation withstand voltage OVERALL DIMENSIONS:- i) Length ii) Breadth iii) Height 27 7.0 Station Battery (110 volts 200AH lead acid type with plante positive plates) Guaranteed Technical Particulars ---------------------------------------------------------------------------------------------------------------ITEM DESIGNATION VALUE REMARKS ----------------------------------------------------------------------------------------------------------------1. Manufacture’s name and place. 2. Capacity of battery at 10 hours discharge rate (AH). 3. Cell designation in accordance with IS-1652 4. 5. i) Nominal voltage of each cell. ii) Voltage of each cell during floating condition. iii) Voltage of each cell during boosting condition. i) Type of positive plates ii) Type of negative plate Size and material of connectors and method of connections between cells. 6. i) Recommended starting rate of charging. ii) Recommended finishing rate of charging. 7. Voltage per cell at the end of charge at the finishing rate. 8. i) Recommended float charging rates (Max. Min.) ii) Boost charge. iii) Equalizing charge 9. Thickness, type and material of container. 10. Thickness, type and material of the separators. 11. a) Amount of electrolyte per cell required for first filling. b) Specified gravity of electrolyte. 12. Recommended specify gravity of electrolyte at the end of full charge. 13. Expected specific gravity of electrolyte at the end of discharge of 10 hours discharge rate. 14. Overall dimensions of each cell. 15. Distance between the centers of cell when erected. 16. Weight of each cell complete with acid/electrolyte. 17. Maximum number of charge/discharge cycles, the cell can withstand. 18. Short circuit current rating of battery. 19. Size and type of cable recommended for connection of battery with charging equipment. 28 20. Ampere hour and watt-hour efficiency at 10 hours discharge rate. 21. Internal resistance of cell. 22. Maximum electrolyte temperatures that cell can withstand without affecting the service life of the battery. 23. a) Continuously. b) For short period. Recommended maximum period of storage before the first charge. 24. Estimated life of battery. 25. Water still. i) Make ii) Capacity iii) Type 26. Recommended total input (AH) (initial charging) 27. Wooden stand dimensions required for the battery bank.. 29