Survey
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
MSI 5A 5A Current input adapter Technical Reference Manual v 1.0 www.dewesoft.com MSI 5A Table of Contents 1 Technical data .................................................................................................................................. 3 1.1 2 Electrical specifications ........................................................................................................... 3 Connectors ....................................................................................................................................... 4 2.1 Input connector pinout ............................................................................................................. 4 2.2 Output connector pinout .......................................................................................................... 4 3 Safety instructions ............................................................................................................................ 5 4 Operation .......................................................................................................................................... 5 4.1 4.1.1 5 MSI adapters / TEDS sensor support ...................................................................................... 6 Manual operation ................................................................................................................. 7 Documentation Version .................................................................................................................... 8 Document version: 1.0 www.dewesoft.com Page 2 / 9 MSI 5A 1 Technical data 1.1 Electrical specifications Input current 5.00A (dc or acrms continuous) (1) Pulse load 25.00A @ 5.0sec, 120sec interval, continuous Shunt resistor 10.0mΩ Resistance Tolerance Calibrated to ±0.1%, calibration in TEDS Temperature Coefficient < ±30ppm/ºC typical (+20ºC to +60ºC) Resistor dielectric withstanding voltage 1000Vac Input connector type MSTB 2,5/ 3-STF-5,08 Phoenix Contact, mates with MSTB 2,5/ 3-GF-5,08 Connector info 2.5mm2 Nominal cross section TEDS MSI Compatible (1) Do not exceed absolute maximum rating! Document version: 1.0 www.dewesoft.com Page 3 / 9 MSI 5A 2 Connectors 2.1 Input connector pinout Wire connector, 3pin plug - + G Pin 1 2 3 Name + G I/O I, Power I, Power I, Signal Description Current Input Current Input + Analog Ground Illustration 1: 3pin plug Illustration 2: The figure shows a 10-position version of the plug 2.2 Output connector pinout DSUB 9 connector Pin 1 2 3 4 5 6 7 8 9 Name OE+ Out+ OEsnsAGND Reser. OEsns+ OutOETEDS I/O I, Power O, Signal I, Power I I/O I, Signal O, Signal I, Power I/O, Signal Description Output enable + Signal Output + Output enable Analog Ground Reserved / Not Connected Output Enable + Signal Output Output enable TEDS Illustration 3: 9 pin DSUB plug Document version: 1.0 www.dewesoft.com Page 4 / 9 MSI 5A 3 Safety instructions Your safety is our primary concern! Please be safe! WARNING Use MSI 5A adapter only with SIRIUSi - Isolated version. Signal Outputs are disconnected from DSUB connector contacts until adapter and its DSUB connector is connected to DAQ to protect the user from possible high voltage present on the contacts when current source input is already connected to the input 3pin plug. Protective switch is powered by DAQ Exc. Voltage. Illustration 5: MSI 5A Adapter partial schematic 4 Operation Signal output enable indicator Illustration 4: MSI 5A Adapter Signal output enable indicator LED is turned ON (green) when output signal is present on the Signal Output pin 2 and 7. Document version: 1.0 www.dewesoft.com Page 5 / 9 MSI 5A 4.1 MSI adapters / TEDS sensor support Since there is an inbuilt TEDS device in the adapter itself and if MSI adapters/TEDS sensors under Hardware setup is selected, adapter will be recognised and parameters will be set automatically. Please check if you are using the latest software where MSI 5A Adapter is supported. Illustration 6: Setting – Hardware setup Illustration 7: MSI adapters/TEDS sensors checkbox Illustration 7: MSI 5A adapter is recognized and set automatically Document version: 1.0 www.dewesoft.com Page 6 / 9 MSI 5A 4.1.1 Manual operation If MSI adapters/TEDS sensors is left unchechked under Hardware setup then sensor supply and range has to be set manualy. Illustration 9: MSI adapters/TEDS sensors checkbox is left unchecked Under Channel setup for channel N, set Excitation voltage to 12V. Signal Output Enable indicator LED will be turned on to indicate that measured signal is present on the signal outputs. Illustration 10: Excitation voltage setting Document version: 1.0 www.dewesoft.com Page 7 / 9 MSI 5A 5 Documentation Version Doc-Version Date [dd.mm.yyyy] Notes 0.9 09.05.2014 Pre-release version 1.0 21.05.2014 Initial version, amended electrical specs., new safety instructions, new schematic. ___________________ For support please contact support [at] dewesoft.com Document version: 1.0 www.dewesoft.com Page 8 / 9 MSI 5A Document version: 1.0 www.dewesoft.com Page 9 / 9