Survey
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
C o m p r e h e n si v e a n d R o u ti n e C h a r a c t e r i z ati o n o f P r o t e i n s a n d P e p ti d e s by LC / M S a n d LC / M S E Asish Chakraborty, St John Skilton, Weibin Chen and John C. Gebler Waters Corporation, Milford, MA, U.S. INT RODUC T ION biopharmaceutical informatics to deliver improvements in laboratory The comprehensive characterization of biopolymers as drug candidates is a requirement for safety and regulatory agencies. productivity. Tasks that took two weeks to complete, such as peptide mapping, can now be accomplished in a day. Challenges include the high molecular weight of biopolymers and There are good reasons to determine the intact mass of a mono- the heterogeneous nature of protein drugs, which require extensive clonal antibody (mAb): in addition to providing an accurate mass characterization to achieve regulatory approval. Comparability of the protein, intact mass analysis provides an overall view of during manufacturing changes must be demonstrated, or to provide the heterogeneity of the protein, showing relative amounts of the intellectual property (IP) protection against biosimilars. various forms. Minimal sample preparation and chromatographic The analyses described here show how different analyses can be performed to provide comprehensive information more quickly to meet these business objectives. All of these analyses can be done separation is required, so intact mass analysis provides results in minutes. Furthermore, generic methods can be used for rapid analysis of many different sample types. In an organization where there is a large increase in the number by non-specialists on the same platform. The combination of liquid chromatography and electrospray mass spectrometry (LC/MS) provides enabling technology for well-characterized and comparable biotherapeutics. LC/MS analysis of proteins of biopharmaceutical candidates advancing through the pipeline, such an approach provides results rapidly without having to request additional headcount. and peptides provides high levels of detail to aid characterization. For example, if there is a need to quickly confirm that the correct protein However, the ability to routinely generate and interpret LC/MS data has been made, samples may be submitted to the analytical character- in a timely manner has been challenging in the past because involve- ization group by biochemists or biologists who are not experts in mass ment of an expert was required. Additionally, a major hindrance has spectrometry. An accurate molecular weight of the protein would ensure been, until now, the lack of automated tools to complete the analysis. that the overall mass matches the expected mass. Without this confirma- In order to increase laboratory productivity, high-performance mass tion, the wrong protein may be tested in several expensive bioassays, spectrometers need to be made more accessible. increasing time and costs for the organization. The Waters Xevo™ QTof MS System is a benchtop instrument designed to provide organizations with easy access to the most sensitive, high-performance, accurate mass MS, MS , and MS/MS E analysis available. The system incorporates Waters’ design philosophy of Engineered Simplicity™ and features tools for automated calibration and system monitoring, allowing organizations to obtain the very best MS performance in routine analyses. This application note focuses on intact protein measurement and peptide mapping for biotherapeutics. We demonstrate a system solution that integrates ACQUITY UPLC® separations, application-specific column chemistries, Xevo QTof MS mass detection, and industry-leading MET HODS Sample preparation Intact monoclonal antibody (IgG1) A humanized IgG1 was received as a buffered solution (21.0 mg/mL). The solution was diluted to 0.5 mg/mL with 50 mM ammonium bicarbonate in preparation for intact mass analysis. Mass spectrometry conditions Reduced antibody The antibody sample was reduced with DTT at 37 °C for 20 min MS system: Waters Xevo QTof MS using a published method. The solution was diluted to 0.10 mg/mL Ionization mode: ESI positive (pH 3.0) with 2% (v/v) formic acid aqueous solution. Capillary voltage: 3.0 kV 1 Protein digest (for peptide mapping) Cone voltage: 25 V (peptide) / 45 V (protein) Desolvation temp.: 350 °C RapiGest™ SF (0.05% in final solution) was added to the monoclo- Source temp.: nal antibody (mAb) stock solution, and the sample was heated at Desolvation gas: 800 L/Hr 60 °C for 30 minutes. The protein was then reduced with 10 mM Acquisition range: m/z: 50 to 1990 (peptide) / 600 to 4500 DTT at 60 °C for 30 min, and alkylated with 13 mM of IAA in the dark for 45 minutes. Trypsin digestion was performed at 37 °C overnight (trypsin/protein ratio was 1:50). The digest was diluted to 0.015 mg/mL with 0.1% formic acid. 150 °C (protein) Informatics/data processing BiopharmaLynx™ Application Manager, v. 1.2, of MassLynx Software UPLC conditions LC system: Waters ACQUITY UPLC® System Columns: • For intact IgG protein: MassPREP™ Micro desalting column 2.1 x 5 mm, 20 µm, 1000Å SAMPLE PREPARATION P REPARE LIQUID CHROMATOGRAPHY • For separation of IgG heavy/light chains: ACQUITY UPLC® System ACQUITY UPLC C4 BEH300 RapiGest™ SF 1.7 µm, 2.1 x 50 mm • For peptide mapping: ACQUITY UPLC C18 BEH300 ANALYZE 1.7 µm, 2.1 x 150 mm Column temp.: • Intact IgG protein: 80 °C • Reduced monoclonal antibody: 80 °C • Peptide mapping: 60 °C Mobile phase A: 0.1% Formic acid (Water) LC SEPARATION ACQUITY UPLC® Column MASS SPECT ROMET RY INT ERPRE T Xevo Qtof ™ MS Mobile phase B: 0.1% Formic acid (ACN) Flow rates: 0.2 mL/min Gradients: • Intact monoclonal antibody: 10-90% B in 1.5 min. • Reduced monoclonal antibody: INFORMATICS BiopharmaLynx™ 1.2 DECIDE Application Manager for MassLynx™ Software 25-35 %B over 15 min. • Peptide mapping: 2% B - 40B% in 90 min. Figure 1. The general Waters LC/MS workflow logically steps from sample preparation to data analysis, with integrated instrumentation and software enabling the process to occur seamlessly. RESULT S AND DISCUSSION Analysis of humanized IgG was used as an example to demonstrate the general LC/MS workflow as well as Xevo QTof MS’s performance. changes in the protein’s heterogeneity with different cell lines, helping to reduce development and manufacturing costs. In QC functions, an intact mass analysis would give general confirmatory information. UPLC® Technology provides significant advantages for all of these Figure 2 shows mass spectra of an intact IgG from a traditional QTof analyses by avoiding the need for flow splitting and by providing mass spectrometer and the Xevo QTof MS, respectively. Both spectra increased sensitivity for MS detection show a charge envelope with a distribution of multiply-charged ion The therapeutic was analyzed in three ways: 1. As an intact antibody 2. In reduced form to show the masses of the light chain and peaks. Although great similarity between the two spectra can be found, the Xevo QTof MS data show a six-fold sensitivity increase in comparison to traditional QTofs. heavy chain after minimal chromatographic separation 3. Enzymatic digestion followed by LC/MS with the annotation of lions. In the worst case, if a protein is approved and later found to be incompletely characterized because of the presence of an undesired form, the product may have to be removed from the market, costing the company millions of dollars and hurting its reputation. For choosing the optimum cell line, determining the protein intact mass analysis is a powerful, high-throughput method used to show 51+ 46+ 69+ 39+ 50+ 100 Intensity to a delay in achieving regulatory approval, costing the company mil- Traditional QTof 1.5 µg injected 58+ 0 Information on heterogeneity is provided by intact mass measurement. Incomplete characterization of a candidate protein could lead Intact IgG Intensity % Analysis 1: Intact mass analysis 100 55+ Xevo QTof MS 0.5 µg injected 46+ % each peptidic element of the antibody 59+ 43+ 65+ 0 2000 2400 39+ 2800 m/z 3200 3600 4000 4400 Figure 2. Improved sensitivity of Xevo QTof for intact mass analysis. For the intact IgG analysis, the Xevo QTof MS showed a six-fold improvement in sensitivity in comparison to tradition quadrupole time-of-flight MS. In a manual analysis, a scientist typically transfers this data to a control sample and an analyte so that differences are easily seen software package to deconvolute the multiply-charged states to a (Figure 3). The use of such software removes the need for intermedi- zero charge molecular mass or distribution for the intact protein. ate manual transfers and avoids human bias. A large number of With BiopharmaLynx 1.2 software, spectral deconvolution is per- samples can be rapidly compared to a control and reports can be formed automatically on the acquired data. The user is provided generated automatically for external users. with an interactive browser page that displays a comparison of a Figure 3. Deconvoluted mass spectra of a humanized monoclonal antibody from BiopharmaLynx 1.2. Panel A and Panel B display the batch comparison of the same antibody to demonstrate the glycoform variation caused by the production process. Analysis 2: Analysis of heavy and light chains from a reduced monoclonal antibody formation) can be detected by analysis of partially reduced monoclonal antibodies (or of peptides from enzymatic digestion as discussed below) with chromatographic separation. Chromatographic separation of the heavy and light chains adds further detail to the characteristics of an mAb, confirms that the Figure 4 displays separate spectra for the heavy and light chains glycoprotein profiles of candidate expression clones match the from a reduced monoclonal antibody. The corresponding decon- expectation, or checks whether there are unusual distributions of voluted spectra for the light chain and heavy chain are also shown. glycoforms. When specific glycoforms are of interest, the separation The chromatogram shown in inset demonstrates that high resolution of light and heavy chains helps to examine glycoforms more closely. separation by an ACQUITY UPLC BEH C4 column enables the differentiation of minor isoforms of either heavy chain or light chains, The separation of light chain and heavy chain also allows the providing enhanced assessment on the heterogeneity of the sample. relative component quantitation to be achieved, and modifications specific to the light or heavy chains can be characterized. Mass changes associated with specific residues (such as succinimide Figure 4. LC/MS analysis of a reduced monoclonal antibody. Complete resolution of the light chain and heavy chain were achieved using a UPLC BEH C4 column. 21 Analysis 3: Peptide mapping analysis to traditional LC-UV/VIS detection. However, single-stage MS analysis In intact mass analysis, the overall heterogeneity of the protein is obtained. In order to characterize modifications that lead to small or no mass changes in the intact protein mass (e.g., deamidation or structural isomers of glycans), peptide mapping with MS detection provides a valuable technique for detailed and comprehensive modification coverage in a simple manner. may not be capable of resolving peptides that are isobaric, nor can suspected peptide modifications be identified and localized from MS data alone. MS/MS data are therefore used to generate fragment ion mass spectra. In the past, MS/MS data were acquired with selected peptides using a traditional data-dependent (or directed) MS/MS acquisition (DDA). We present here an approach that is a significant improvement on DDA by using MSE analysis to confirm sequence information. In LC/MS this can be done with ease using only one enzyme to digest the protein and obtain sequence coverage above 95%.The ability of a peptide map to highlight small changes in the primary structure of a protein makes it valuable for establishing the identity, purity, and composition of a protein. For example, in shelf life studies the ability to detect modifications is vital. In the optimization of in vitro folding processes the arrangement of disulfide bridges is crucial. MS E provides a comprehensive MS/MS picture without any prior knowledge of the sample and is applicable across all charge states. (See references 2-7 for details of MS E.) This means that the peptide map can be performed in an unbiased, systematic manner and provide consistent results without the need for an expert. The methodology also means that the same dataset could potentially be re-analyzed at a later stage for additional information without LC/MS analysis has greatly expanded the capability to develop having to re-run the samples – saving significant costs, time, and and interpret data from peptide mapping experiments, compared capital investment. 100 Normalized Intensity % Traditional QTof 30 pmol inj 0 10.00 30.00 50.00 100 90.00 Xevo QTof MS 10 pmol inj Normalized Intensity % 0 70.00 10.00 30.00 50.00 Time (min) Figure 5. Improved sensitivity of Xevo QTof MS for peptide mapping experiment. 70.00 90.00 In the BiopharmaLynx browser, the user is able to interac- In BiopharmaLynx 1.2, additional information on peptide sequence tively annotate data that might previously have been overlooked. is also provided. This confirms the sequence of the peptides from the Modifications are annotated automatically and disulfide bridges protein. Figure 6 shows a screenshot from the tabular browser display can be shown on the peptide map. Increased sensitivity provided presented to the user. In the right-most column shown, the by the Xevo QTof MS enhances the information available with no y- and b- ions are listed to indicate exactly which backbone fragments compromise in productivity. were automatically identified from the MS/MS spectra. The user is also able to select alternative sequences where they are presented or In Figure 5, an Enolase digest was analyzed by UPLC/MSE. The compari- reject them if the user prefers a different interpretation. son between a traditional QTof and the new Xevo QTof MS highlights the improvements in sensitivity for this workhorse instrument. Figure 6. Results of BiopharmaLynx-processed Xevo QTof MS data, showing MS and MS/MS (MSE) data. Fragment ions (b/y ions) are identified and listed in the Peak Match Data Table. 23 Figure 7 shows the sequence information superimposed on a spectrum in the BiopharmaLynx browser. The y-series amino acid sequence information is shown in red underneath the b-series sequence in blue. Figure 7. The Fragment Ion display from BiopharmaLynx 1.2 showing sequenced peptides on an MS/MS spectrum for a control (top) and an analyte (bottom). Additional information is available in the tabular display showing modifications and locations of these modifications. CONC LUSION References n 1. Wang L, Amphlett G, Blättler WA, Lambert JM, Zhang W. Pharm. Res. 2005; 22: 1338. This application note has demonstrated high-performance, routine characterization of intact proteins and peptide maps, saving days of time for providing a complete analysis. n This LC/MS system solution featured: • Optimized LC resolution, sensitivity, and speed with the ACQUITY UPLC System • Robustness and reproducibility with ACQUITY UPLC Columns and 1.7 µm particles • High-sensitivity, accurate mass MS E with the Xevo QTof Mass Spectrometer • Targeted, streamlined, and sophisticated conversion of data 2. Chakraborty AB, Berger SJ, Gebler JC. Rapid Commun. Mass Spectrom. 2007; 21: 730-744 3. Hoff ER; Chloupek RC. Methods Enzymol. 1996, 271: 51. 4. Williams KR, Stone KL. Methods Mol. Biol. 1995; 40: 157. 5. Bateman RH, Carruthers R, Hoyes JB, Jones C, Langridge JI, Millar A, Vissers JP. J. Am. Soc. Mass Spectrom. 2002; 13: 792. 6. Silva JC, Denny R, Dorschel CA, Gorenstein M, Kass IJ, Li GZ, McKenna T, Nold MJ, Richardson K, Young P, Geromanos S. Anal. Chem. 2005; 77: 2187. 7. Silva JC, Gorenstein MV, Li GZ, Vissers JP, Geromanos SJ. Mol. Cell. Proteomics 2006; 5: 589. into usable information with BiopharmaLynx informatics n We presented an improved system that provides more comprehensive and faster characterization of: • Intact proteins • Peptide maps n Automated peptide sequence confirmation is now possible with MS E and BiopharmaLynx. n The ACQUITY UPLC/Xevo QTof MS system combines into a comprehensive analytical workflow solution for the biopharmaceutical laboratory, intelligently integrating instrumentation with software to provide improvements in productivity and efficiency: from instrument performance, to data generation, to interpretation and decision-making. Waters, ACQUITY UPLC, and UPLC are registered trademarks of Waters Corporation. Xevo, RapiGest, BiopharmaLynx, MassLynx, MassPREP, Engineered Simplicity, and The Science of What’s Possible are trademarks of Waters Corporation. All other trademarks are the property of their respective owners. ©2009 Waters Corporation. Printed in the U.S.A. May 2009 720003046en AG-UM Waters Corporation 34 Maple Street Milford, MA 01757 U.S.A. T: 1 508 478 2000 F: 1 508 872 1990 www.waters.com