* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download Power Quality Solutions Peak demand management systems
Survey
Document related concepts
Wireless power transfer wikipedia , lookup
Audio power wikipedia , lookup
Mains electricity wikipedia , lookup
Electric power system wikipedia , lookup
Voltage optimisation wikipedia , lookup
Electrification wikipedia , lookup
Switched-mode power supply wikipedia , lookup
History of electric power transmission wikipedia , lookup
Grid energy storage wikipedia , lookup
Intermittent energy source wikipedia , lookup
Immunity-aware programming wikipedia , lookup
Alternating current wikipedia , lookup
Power over Ethernet wikipedia , lookup
Transcript
Janitza electronics GmbH Vor dem Polstück 1 D-35633 Lahnau Germany +49 6441 9642-0 +49 6441 9642-30 [email protected] www.janitza.com GridVis Software ProData® data logger Peak demand management systems Power Quality Solutions Energy Management (ISO 50001) and Power Quality (EN 50160, ITIC, IEEE 519) Powerfull data logging The intelligent reduction of peak loads Improve your Power Quality Power Factor Correction GridVis-Basic Software is included in the scope of delivery of all UMG measurement devices and can be extended to versions Professional, Enterprise and Service. It offers optimum pre-conditions for Energy Management Systems and Power Quality Solutions. GridVis provides historical values, e.g. load profiles, which allow a trend analysis as well as online measurement values for monitoring the actual load scenario and much more. Data loggers are a mandatory equipment in energy management solutions, cost center applications or process data aquisition. Peak demand management systems are essential to minimize costly power peaks and avoid electrical distribution systems overloads. ProData® is a powerful data logger suitable for capturing and saving all consumption and process data as well as status messages (e.g. switch status) using pulse inputs. The energy bill is made up of three contributing factors, which are: Basic charges Peak demand charges Energy cost (kWh) Power quality as well as supply reliability are of major importance in todays business environment. Highly sensitive equipments and processes are heavily depending on a clearly defined power quality. In order to provide stable processes and an adequate power quality, despite increasing number of “polluting” equipments, countermeasures for power quality improvements are necessary. GridVis is a powerful tool for automatic collection of measurement data, for analysing and visualising the measurement results, e.g. the topologyview provides a quick overview of an actual online situation. Automatically generated reports for most common Power Quality Standards as well as reports for energy consumption can be freely scheduled by the user. The data can be used for analyzing energy consumption, operating hours or for monitor switches statuses or faults in buildings or production facilities. Load profile over a period of 24 hours ✔ Target value Power savings These charges individually contribute to your energy bill and have to be in line with your requirements. Managing your Peak Demand is an option that can be altered and has great potential to reduce your energy account and still allowing the same energy usage. Main features Integrated reporting and statistic Configurable user access Export of historical data (XLS-files) Easy linking with Building Management Systems (BMS), PLCs, SCADA Smart Energy & Power Quality Solutions Janitza electronics® is offering a comprehensive package for the improvement of power quality: Power Factor Correction Harmonic Filters (detuned & tuned) Dynamic PFC Key components for all above systems P in kW Item no.: 33.03.607 • Doc no.: 2.500.034.0 • Edition 09/2013 • All rights to technical changes are reserved. Smart Energy & Power Quality Solutions Main features 15 digital / impulse inputs 3 digital outputs, controllable via Modbus, Main features weekly timer, boundary value and temperature monitoring Temperature measurement input Ethernet interface (Modbus TCP, NTP …) RS485 (Modbus RTU, slave, up to 115 kbps) 32 MB flash memory Clock and battery function 64 weekly timers Modbus-Ethernet-Gateway functionality Including GridVis-Basic software Optimum limitation of effective power peaks Typically return on investment (ROI) within less than 2 years by: Up to 64 load shedding stages Reduction of reactive power and saving of Intelligent algorithm for controlling the peak Reduction of harmonic loading (THD-V) demand within the specified limits Wide range of communications: RS485, Modbus, Ethernet, Profibus Configuration on the device homepage (Emax App available for Profibus or Modbus) Harmonics display, monitoring of short-term interruptions consumed real energy (kWh) Elimination of transients and voltage sags Compensation of fast changing loads Cutting demand peaks Reduction of: electricity costs, maintenance costs, cost for production losses and capital expenditure. Quick Overview 277 / 480 V AC UMG 508*1 UMG 511 UMG 508 52.22.040 52.22.038 240 / 415 V AC*6 52.22.036 277 / 480 V AC 52.22.039 52.14.001 (52.14.005) 52.22.037 52.16.027 UMG 96RM P*2 M E*2 CBM*2 EL *2 52.22.035 UMG 96L UMG 96RM 52.16.001 UMG 605*1 UMG 96L UMG 605 UMG 604 52.16.002 52.20.002 EP*1 277 / 480 V AC UMG 511*1 52.21.001 52.19.001 417 / 720 V AC 417 / 720 V AC 480 V AC - 480 V AC 600 V AC 600 V AC 95 – 240 V AC; 135 – 340 V DC*3 95 – 240 V AC; 135 – 340V DC*3 - 20 – 250 V AC; 20 – 300 V DC 95 – 240 V AC; 80 – 340 V DC*3 95 – 240 V AC; 80 – 340 V DC*3 -/• 4 5.4 kHz 5,400 • 10 / 12 1. – 25. • • 0.2 % 0.5 (.../5 A) 3 • •/• 4 20 kHz 20,000 • 10 / 12 1. – 40. • • 0.2 % 0.5 (.../5 A); 1 (.../1 A) 2 2 4 1 Comparator • -/• 4 20 kHz 20.000 • 10 / 12 • 1. – 63. • 0,5 % 1 2 20 • •/• 4 20 kHz 20,000 • 10 / 12 1. – 40. • • 50 µs • 0,2 % 0.5 (.../5 A); 1 (.../1 A) 2 2 4 1 Jasic® (7 Prg.) • •/• 4 20 kHz 20,000 • 10 / 12 1. – 63. • • • 50 µs • 0.2 % 0,5 (.../5 A); 1 (.../1 A) 2 2 4 1 Jasic® (7 Prg.) • -/• 4 *5 2.5 / 3 kHz 50 1/1 1% 2 3 • •/• 4 21.33 / 25.6 kHz 21,330 / 25,600 • 10 / 12 • 1. – 40. • • 0.2 %; 0.5 % 0.5 (.../5 A); 1 (.../1 A) 4 4 - (3)*7 6 6 2 (5)*7 4 3 4 +2 4 2*8 Comparator • •/• 4 20 kHz 20,000 • 10 / 12 1. – 40. • • 50 µs • 0.1%; 0.2 % 0.2 (.../5 A) 8 5 4 Jasic® (7 Prg.) • •/• 4 20 kHz 20,000 • 10 / 12 1. – 63. • • • 50 µs • 0.1 %; 0.2 % • 0.2 (.../5 A) 8 5 4 Jasic® (7 Prg.) • - 4 MB • • - • • - • • • - • - • • - • • - • • - • • •/• • • - • • •*4 • • • •*4 GridVis • • • • •/• • • • • •*4 • - - - - • - - 3 - 256 MB • • • •*4 GridVis - - 256 MB • GridVis 128 MB 2 3 - 256 MB • • • GridVis 128 MB - Top Class Energy Management at economic cost • GridVis - - - • • GridVis • - • - • • • - • - • • •/• • • - • - • - • • - - • • • • • - - 256 MB • • • •*4 GridVis • • • •/• • • • • •*4 Class A ( IEC 61000-4-30 ) power quality analyser ( EN 50160 incl.) 480 V AC 90 – 276 V AC / DC Multifunctional power analyser – Ethernet, Profibus, Modbus, BACnet, SNMP - 95 – 240 V AC; 135 – 340 V DC*3 The most economic instrument for basic applications 480 V AC - Power quality analyser EN 50160 – IEEE 519 - WEB – Email – Ethernet – easily integrated into the network Clock Bi-metallic function Fault recording function Peak demand management Software for energy management and power quality Interfaces RS232 RS485 USB Profibus DP M-Bus Ethernet Web server / e-mail Protocols Modbus RTU Modbus gateway Profibus DP V0 Modbus TCP/IP, Modbus RTU over Ethernet, SNMP BACnet IP/MSTP UMG 604 E*1 277 / 480 V AC 277 / 480 V AC The Professional for the light tariff Three phase / four phase (L-N, L-L) Quadrants Scan frequency 50/60 Hz Measurement points per sec. Continuous measurement Effective value from periods (50/60 Hz) Differential current measurement Harmonics V / A Distortion factor THD-V / THD-I in % Unbalance Short/long-term flicker Transients Short-term interruptions (sag / swell) Accuracy V, A Class A acc. EN 61000-4-30 Effective energy classification (kWh) Digital inputs Digital / pulse output Current measurement channels Temperature input Integrated logic Minimum / maximum value memory Memory size 240 / 415 V AC UMG 20CM 14.01.625 Für die RCM-Differenz- und Betriebsstromüberwachung Nominal grid voltages For using in three phase / 4 wire systems with grounded neutral up to maximum For using in three phase systems without grounded neutral Auxiliary voltage P*1 52.20.001 52.18.001 UMG 104 *1 UMG 20CM UMG 104 UMG 103 UMG 103*1 Item number The Compact for master-slave-operation Quick Overview UMG Meters Type 256 MB • • • •*4 GridVis • • • •/• • • • • •*4 *1 UL-certified meters on request *2 ETL-certified meters on request *3 Other voltages are available as options *4Option *5 Not for effective and reactive power *6 In the 230 V version *7 Combination options for inputs and outputs: a) 5 digital outputs b) 2 digital outputs and 3 digital inputs *8 Combined function: Either analog / temperature / RCM input Note: For detailed, technical information, please refer to the respective operating instructions and the Modbus address lists. • : Included - : not included