Survey
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Lovibond® Water Analysis Tintometer® Group Potable Water Test Kit Perfect systems for the control and optimisation of water quality Microbiological Tests Chemical Tests • • • • • • • • • • • • • MLC (2006) and ILO178 Compliance WHO Guide to Ship Sanitation References Simple Coliform and E.coli Screening Total Bacterial Monitoring (TVC, HPC) Pseudomonas Test Option Enterococci Test Portable Incubator No Hazardous Materials No Refrigeration Required www.lovibondwater.com Residual Chlorine Tests for Tanks and Outlets Superchlorination Test Digital Thermometer Long life, tablet reagents Logbook & Record Keeping • Step By Step Method Book • Logbook for Record Keeping • Video Training Guide Potable Water Supplies Disinfectant and pH Tests The Maritime Labour Convention (MLC, 2006) entered into force in August 2013 and presented the Maritime Industry with a legal requirement to supply quality, nutritious, consistent drinking water to crew members. Interpreting this obligation can be daunting, especially when presented with a range of international and flag state protocols. The WHO Guide to Ship Sanitation (3rd edition) is a good reference, but even this has been updated in the last few years to accommodate the control of more recently identified bacteria such as legionella. It is important to disinfect potable water prior to consumption, even if water has been produced from on-board evaporators. Adding trace levels of chlorine is a standard treatment but others, such as UV or chlorine dioxide are also possible. Technical Data The Lovibond® Marine Potable Water Test Kit has been developed to address all these protocols. It combines simple procedures to incorporate in to a vessel’s “Water Safety Plan” to help ensure the maintenance of high quality water throughout the potable network. Microbiological Tests It is important to screen potable water for harmful bacteria that may have inadvertently entered the water system, either through leaks, human error or even human/animal faecal contamination. Corroded or infrequently used sectinos of pipework can also harbour harmful bacteria. The Marine Potable Water Test Kit is supplied with simple, yet sensitive, tests that give a colour change in the presence of coliforms, E.coli, enterococci and pseudomonas - all harmful indicator bacteria which might be present through a breach in security of supply. Microbiological Tests Coliform/E.Coli Method Presence / Absence Sample Size 100ml Sensitivity 1 CFU / 100ml Incubation 24 Hours Coliform Colourless to Yellow (35°C) E.coli Test Fluorescence in UV (35°C) Pseudomonas Fluorescence in UV (38°C) Enterococci Yellow to Blue / Green (35°C) Total Bacteria Plate Test Chlorine is nearly always the preferred treatment at “shock doses” to facilitate the cyclical sterilisation of tanks, pipework and showerheads. The Lovibond® CHECKIT Comparator is included in the Potable Water Test Kit to enable chlorine and pH monitoring at all parts of the water system. Results are obtained in a few minutes. Add a reagent tablet to a 10ml sample of water. Cap the tube and shake to dissolve the tablet. Chlorine will turn the sample pink. Place the sample into the comparator and rotate to the colour disc to match and confirm the result. Method Dehydrated Selective Agar Sample Size 1ml Sensitivity 0-200 & 0-2000 CFU/ml Incubation 35°C / 48 Hours Total Bacteria Red Colony Count Disinfectant & pH Tests Method CHECKIT® Comparator Sample Size 10ml - instant result Sensitivity 0-1mg/l Cl2 0-4mg/l Cl2 10-300mg/l Cl2 pH 4-10 (tanks) (outlets) (disinfection) Incubator Range 5°C > Ambient to 40°C Resolution ± 0.5°C Operation 12V DC, 3 Amps Power Adaptors 12V (in-car) + 100-240V Universal (UK, EU, USA) Weight 1.7 kg DI 10 Portable Incubator Size 246 x 215 x 162 mm CE Conformity Yes The microbiological tests included require incubation at a fixed temperature to give an accurate result. The Lovibond® DI 10 unit is a compact, robust, digital device that operates at 12V and is supplied with universal power connectivity (UK, EU, USA). Excellent temperature stability is achieved with fan-assisted heating. Digital Thermometer Range 5°C to 1000°C Resolution ± 0.1°C Battery PP3, 200 Hours Weight 155 g Size 130 x 70 x 33 mm CE Conformity Yes Ordering Information P/N Description 56K002701 Marine Potable Water Test Kit 56K028901 Marine Potable Water Test Kit (excluding Pseudomonas) Accessories Total bacterial test plates are included to monitor general water quality. Add 1ml of water to a dehydrated plate and incubate for 48 hours. Count the number of red colonies to assess contamination levels. The Tintometer Ltd Lovibond House Solar Way, Solstice Park Amesbury, Wiltshire, SP4 7SZ Tel.: +44 (0)1980 664800 Fax.: +44 (0)1980 625412 [email protected] Lovibond® and Tintometer® are Registered Trade Marks of The Tintometer® Group. All translations and transliterations of LOVIBOND® & TINTOMETER® are asserted as Trade Marks of The Tintometer® Group. Registered Office: Lovibond House, UK. Registered in England No. 45024. Errors and Omissions Excepted - Content subject to alterations without notice. 56M000701 DI 10 Incubator 56M000801 Digital Thermometer 145000 CHECKIT® Comparator 56B008301 Total Bacteria Plates 56B001425 Coliform/E.coli Test Pack 56B002225 Pseudomonas Test Pack 56B002330 Enterococci Test Pack References International Health Regulations, 2005 Maritime Labour Convention (MLC, 2006) ILO 178 (2009) WHO Buide to Ship Sanitation (3rd Edition) www.lovibondwater.com