Each of the Charts on this page show the end-use data averages per each Climate Region. The Climate Regions include Blue as the coldest Region, with Green also cold, but less so. Yellow has mild winters and Red has little seasonal change. The data has been organized into different end-use combinations that are identified in these charts as Group 1, Group 2, and Group 3. Group 1 data clearly indicates that the Red, Green and Yellow Regions expend most of their energy use in climate control for the building. The colder regions spend most of their energy heating the building. The Yellow Region spend more energy on cooling the building. In the Red Region, the majority of energy shifts to the plug load and equipment category. Group 2 data combines building climate control into a single category of heating/cooling since the design approaches (including building envelope and load reduction strategies) are interrelated for these two systems. In this group the numbers for lighting and plug loads and equipment were also combined since the load reduction strategies for design of these systems are also interrelated (daylighting, specification of efficient components, controls to support load reductions). Group 3 data further consolidates the end-use numbers. In this configuration, the Fans/Pumps category has been added to the Heating/Cooling category because in a commercial application the fans and pumps are being utilized in the heating and cooling systems. Group 3 shows that approximately half of energy is utilized to support climate control and the other half for activity functionalism. Energy reduction strategies should balance climate control solutions with activities support solutions . For example, design of the building envelope should strike a balance between providing adequate insulation while also contributing daylighting. In comparing the charts for Group 1 and Group 3, it is apparent that the Red and Yellow Climate Regions would benefit from strategies which would lower plug load and equipment demands such as occupancy sensors and controls because they would also reduce internal heat 100% 90% 80% 70% 60% 50% Lighting Heating Cooling 40% 30% 20% 10% Fans/Pumps Plugs/Equip. Red Region Yellow Region Green Region Blue Region 0% Annual Total MMBtu Averages (Group 1) 100% 90% 80% 70% 60% 50% 40% 30% 20% Fans/Pumps Heat/Cool Light/Plug Red Region Yellow Region Green Region Blue Region 10% 0% Annual Total MMBtu Averages (Group 2) 100% 90% 80% 70% 60% 50% Light/Plugs/ Equip. 40% 30% 20% 10% Heat/Cool/ Fans/Pumps Red Region Yellow Region Green Region Blue Region 0% Annual Total MMBtu Averages (Group 3) gains and thereby reduce cooling costs.