VersaMax 5/12VDC Input Modules October 2008 GFK-2545 Product Description Module Characteristics Discrete input modules IC200MDL643 and BXIOID16512 provide two groups of 8 discrete inputs. Discrete input modules IC200MDL644 (shown below) and BXIOID32512 provide four groups of 8 discrete inputs. Inputs in each group can be either positive logic inputs that receive current from input devices and return the current on the common, or negative-logic inputs that receive current from the common and return current to the input device. Input devices are connected between the input terminals and common terminals. The module supports positive and negative logic inputs. For the inputs to be compatible with TTL devices, the negative logic configuration should be used. I 1 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Module ID IC200MDL643, BXIOID16512: FFFF8008 IC200MDL644, BXIOID32512: 80088008 Isolation: User input to logic (optical) and frame ground: 250VAC continuous; 1500VAC for 1 minute Point to point: None IC200MDL644 INPUT POS/NEG GRP IC200MDL643, BXIOID16512: 16 (2 groups of 8) IC200MDL644, BXIOID32512: 32 (4 groups of 8) Group to Group: 250VAC continuous; 1500VAC for 1 minute OK 2 Points LED indicators One LED per point shows individual point ON/OFF status OK LED indicates backplane power is present Backplane current consumption (5V output) IC200MDL643, BXIOID16512: 70mA maximum IC200MDL644, BXIOID32512: 140mA maximum External power supply None Thermal derating None Configuration parameters Input response times Input Characteristics 5/12VDC 32PT Input voltage 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 1234567 831 0 to +15VDC, +5/12 VDC nominal User input current 1.8mA typ. @ 5VDC, 4.9mA typ. @ 12VDC Input impedance 2.4K Ohm typ. @ 12VDC On state voltage Off state voltage +4.2 to +15VDC 0 to +2.6VDC On state current Off state current 1.45mA minimum 0 to 0.7mA maximum On response time Off response time 0.25ms maximum Power for module operation comes from the backplane. Intelligent processing for the module is performed by the CPU or NIU. Configurable filter time 0 ms, 1.0ms (default), or 7.0ms I OK Product Revision History LED Indicators Rev Individual green LEDs indicate the on/off state of each input point. The green OK LED is on when backplane power is present to the module. Preinstallation Check Carefully inspect all shipping containers for damage. If any equipment is damaged, notify the delivery service immediately. Save the damaged shipping container for inspection by the delivery service. After unpacking the equipment, record all serial numbers. Save the shipping containers and packing material in case it is necessary to transport or ship any part of the system. Configuration Parameters The module’s basic input on/off response time is 0.25ms. 1 Description October 2008 IC200MDL643D BXIOID16512D IC200MDL644D BXIOID32512D April 2005 Improvement to latching mechanism IC200MDL643C IC200MDL644C April 2004 Changed to V0 plastic for module housing. IC200MDL643B IC200MDL644B January 2004 ATEX approval for Group 2 Category 3 applications. BXIOID16512C BXIOID32512C January 2004 Changed to V0 plastic for module housing. ATEX approval for Group 2 Category 3 applications. IC200MDL643A BXIOID16512A IC200MDL644A BXIOID32512A For some applications, it may be preferable to add additional filtering to compensate for conditions such as noise spikes or switch bounce. Input filter times of 0ms, 1.0ms, or 7.0ms are selectable via software configuration, for total response times of 0.25ms, 1.25ms, and 7.25ms respectively. The default is 1.0ms filter time (total response time is 1.25ms). Date IC200MDL643E BXIOID16512E IC200MDL644E BXIOID32512E Updated Power Supply OK signal circuitry. November 1999 Initial product release VersaMax 5/12VDC Input Modules October 2008 GFK-2545 Wiring Connections for Carriers with Two Rows of Terminals Installation in Hazardous Locations • • • • Row B connections shown below are for 32-point modules only. EQUIPMENT LABELED WITH REFERENCE TO CLASS I, GROUPS A, B, C & D, DIV. 2 HAZARDOUS LOCATIONS IS SUITABLE FOR USE IN CLASS I, DIVISION 2, GROUPS A, B, C, D OR NON-HAZARDOUS LOCATIONS ONLY (+) + (-) I1 WARNING - EXPLOSION HAZARD - SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS I, DIVISION 2; A B 1 I3 2 1 I4 3 2 I17 WARNING - EXPLOSION HAZARD - WHEN IN HAZARDOUS LOCATIONS, TURN OFF POWER BEFORE REPLACING OR WIRING MODULES; AND I2 I18 4 I19 I6 5 5 I21 A18 Connection Input 1 Input 2 Input 3 Input 4 Input 5 Input 6 Input 7 Input 8 Input 9 Input 10 Input 11 Input 12 Input 13 Input 14 Input 15 Input 16 Inputs 1-8 Common Inputs 9-16 Common B18 8 8 I23 I9 9 9 I24 I10 10 10 I25 11 11 I13 12 11 I26 I12 12 I27 I14 13 13 I28 I29 I15 14 14 I30 (+) (+) I16 15 15 16 16 I31 17 17 I32 18 18 (+) (+) (+) + (-) (+) Wiring Connections for Carriers with Three Rows of Terminals Side B connections shown below are for 32-point modules only. + (-) Terminal B1 B2 B3 B4 B5 B6 B7 B8 B9 B10 B11 B12 B13 B14 B15 B16 B17 I8 7 7 I22 Field Wiring Terminals Terminal A1 A2 A3 A4 A5 A6 A7 A8 A9 A10 A11 A12 A13 A14 A15 A16 A17 I7 6 6 I20 + (-) WARNING - EXPLOSION HAZARD - DO NOT DISCONNECT EQUIPMENT UNLESS POWER HAS BEEN SWITCHED OFF OR THE AREA IS KNOWN TO BE NONHAZARDOUS. I5 4 3 (+) + (-) I13 Connection Input 17 * Input 18 * Input 19 * Input 20 * Input 21 * Input 22 * Input 23 * Input 24 * Input 25 * Input 26 * Input 27 * Input 28 * Input 29 * Input 30 * Input 31 * Input 32 * Inputs 17-24 Common * Inputs 25-32 Common * 13 I14 14 I7 7 8 1 9 I2 2 16 I9 I8 I1 A 15 17 I10 10 I3 3 (+) I16 I15 4 + (-) 11 13 7 12 14 B 1 15 8 9 I18 2 16 I25 I26 I19 3 17 10 + (-) 18 I27 11 I20 4 (+) (+) I32 I31 I24 I17 I6 6 I30 I23 I12 I5 5 I29 18 I11 I4 + (-) (+) 12 I21 5 I28 I22 6 Operating Note If hot insertion of a module is done improperly, the operation of other modules on the same backplane may be disrupted. See Installing a Module on a Carrier in the VersaMax Modules Manual, GFK-1504. * Inputs available on 32-point modules only. The 32 inputs form groups of 8. Each group has a common connection. Each group may be wired for positive or negative logic inputs. For the 16-point modules, if additional bussed terminals are needed, the B terminals can be made available using a shorting bar. The shorting bar has a maximum current-carrying capacity of 2 Amps per point. See the VersaMax I/O Modules Manual, GFK-1504 for information about using a shorting bar. 2