VCE Physics Unit 1 Topic 3 Medical Physics Unit Outline • This unit covers the following topics • • • • • applications of radioisotopes to medical diagnosis and treatment; the operation of optical fibres as endoscopes and other applications for diagnosis and treatment; the use of laser treatments considering a laser as an intense energy source; processes of medical imaging using two or more of ultrasound, Xrays, CT and PET make simple interpretations of images of the human body produced by ultrasound, X-rays, CT, PET and MRI. Chapter 1 Nuclear Medicine: Radioisotopes 1.0 Nuclear Medicine – A Little History Medical uses of radioactive elements had its beginnings in the work of the Curies, Pierre (1859 – 1906) and his wife Marie (1867 – 1934). Together they discovered two highly radioactive elements Polonium (400 times more radioactive than Uranium) and Radium (900 times more radioactive). The first recorded medical use of a radioactive substance occurred in France in 1901 when radium was used as a cancer treatment. The first recorded radium use in Australia was by a Melbourne dermatologist in 1903. The first diagnostic use of a radioisotope was in 1924 when a decay product of Radium was injected into the bloodstream and its movement through the body was recorded with a geiger counter. 1.1 Radioisotopes Radioisotopes (sometimes called radionuclides) are unstable atoms which, in searching for stability, emit either energy (in the form of gamma rays), or matter (in the form of neutrons, alpha or beta particles). Radioisotopes can be naturally occuring, eg Carbon-14 (14C) or man made, eg Cobalt-60 (60Co). Man made radionuclides are manufactured in either a Cyclotron (a particle accelerator) or in a nuclear reactor which, in Australia’s case, is located at Lucas Heights, just south of Sydney. Radioisotopes are used in many areas: In Agriculture - to investigate plant growth and fertiliser take up. In Industry - to check important welds in pipes etc, and to measure metal thickness. In Archaeology - to carbon date ancient objects. In Sewage Disposal - to trace water flows. In Medicine – to detect and treat disease. 1.2 Medical Radioisotopes When used in Medicine, radioisotopes fall into one of two groups: 1. Diagnostic Radionuclides 2. Therapeutic Radionuclides Radioisotope Half Life A representative list of medical radioisotopes is shown in the table Uses Sodium – 24 (24Na) 15 Hours Study of general biological processes Iron – 59 (59Fe) 46.3 Days Diagnosis of Blood Disease Technetium - 99m (99mTc) 6 Hours Diagnosis of various diseases Cobalt - 60 (60Co) 5.3 Years Treatment of Cancer Strontium - 90 (90Sr) 27.7 Years Treatment of Tumors Iodine – 131 (131I) 2.6 Minutes Treatment of thyroid cancers 1.3 Diagnostic Radioisotopes To be useful as a diagnostic tool, a radioisotope must meet certain criteria. It must: (a) have a short half life, ideally about the same as the time required to perform the diagnosis. (b) not emit alpha or beta radiation, because they would be trapped inside the patient and could not be detected externally. (c) emit gamma radiation which is energetic enough to allow its exact source to be identified. (d) be energetic enough to provide useful clinical information but not so energetic as to be dangerous to the patient. From a field of more than 2300 radioisotopes, only a handful come close to satisfying the criteria for use as diagnostic tools. Of these, the reactor produced Technetium – 99m, is by far the best, being used in more that 80% of all nuclear diagnostic tests performed. Note: the m in the symbol 99mTc means this is the “metastable” form of Tc, which radiates gamma rays and low energy electrons. 1.4 Technetium 99m The radioisotope most widely used in medicine is technetium-99m. It is an isotope of the reactor-produced element technetium and it has almost ideal characteristics for a nuclear medicine scan. These are: a. It has a half-life of six hours which is long enough to examine metabolic processes yet short enough to minimise the radiation dose to the patient. b. Technetium-99m decays by an "isomeric" process which emits gamma rays and low energy electrons. Since there is no high energy beta emission the radiation dose to the patient is low. c. The low energy gamma rays it emits easily escape the human body and are accurately detected by a gamma camera. Once again the radiation dose to the patient is minimised. d. The chemistry of technetium is so versatile it can form tracers by being incorporated into a range of biologically-active substances to ensure that it concentrates in the tissue or organ of interest. 1.5 Technetium Delivery Technetium generators are popularly known as “technetium cows” because they can be “milked” of technetium as needed. The generator consists of a lead pot enclosing a glass tube containing the radioisotope, is supplied to hospitals from the nuclear reactor where the isotopes are made. It contains molybdenum-99, with a half-life of 66 hours, which progressively decays to technetium-99m. The Tc-99m is washed out of the lead pot by saline solution when it is required. The generator is exhausted after approximately two weeks and returned for recharging. 1.6 The Gamma Camera Once produced, 99mTc is linked to chemical compounds which permit specific physiological processes to be scrutinised. It can be given by injection, inhalation or orally. The gamma ray photons are detected by a gamma camera which can view organs from many different angles. The camera builds up an image from the points from which radiation is emitted. This image is enhanced by a computer and viewed by a physician on a monitor for indications of abnormal conditions. Gamma Camera 1.7 Diagnosis Positioning of the radiation source within the body is the fundamental difference between nuclear medicine imaging and other imaging techniques such as x-rays. Gamma imaging provides a view of the position and concentration of the radioisotope within the body. Organ malfunction can be indicated if the isotope is either partially taken up in the organ (cold spot), or taken up in excess (hot spot). A series of images are taken over a period of time that show unusual patterns or rates of isotope movement could indicate malfunction in the organ. A distinct advantage of nuclear imaging over x-ray techniques is that both bone and soft tissue can be imaged very successfully. This has led to its common use in developed countries where the probability of anyone having such a test is about one in two and rising. 1.8 Therapeutic Radioisotopes Rapidly dividing cells are particularly sensitive to damage by radiation. For this reason, some cancerous growths can be controlled or eliminated by irradiating the area containing the growth. External irradiation can be carried out using a gamma beam from a radioactive cobalt-60 source, though in developed countries the much more versatile linear accelerators are now being utilised as a high-energy x-ray source (gamma and x-rays are much the same). Internal radiotherapy is by administering or planting a small radiation source, usually a gamma or beta emitter, in the target area. Iodine-131 is commonly used to treat thyroid cancer, probably the most successful kind of cancer treatment. Iridium-192 implants are used especially in the head and breast. They are produced in wire form and are introduced through a catheter to the target area. After administering the correct dose, the implant wire is removed to shielded storage. This procedure gives less overall radiation to the body, is more localised to the target tumour and is cost effective. 1.9 A Cure for Anything ! At present, approximately 35 radioisotopes are commonly used in the detection and treatment of illness or disease. Those used for treatment include: Radioisotope Cobalt – 60: Dysprosium-165: Iodine-125: Iodine-131: Phosphorus-32: Rhenium-188: Samarium-153: Boron – 10: Use External cancer radiation Treatment, arthritis Treatment, cancer of prostate, brain Treatment, cancer of thryoid Treatment, excess red blood cells Treatment, coronary artery disease Treatment, breast, prostate cancers Treatment, brain tumours Chapter 2 Optical Instruments: Endoscopes 2.0 Endoscopes The name endoscope is derived from two Greek words: endom (within) and skopein (view). The endoscope is an optical instrument used for viewing internal organs through natural openings (ear, throat, rectum, etc.) or through a small incision in the skin. There are 2 basic types of endoscopes: Rigid and Flexible Various rigid & flexible endoscopes In rigid endoscopes the image is conveyed by a relay of lenses. The classical rigid endoscopes have a number of periscopic and field lenses in order to convey the image from distal end to the eyepiece. Generally, a flexible endoscope is referred to as a fibrescope. In flexible endoscopes, a bundle of precisely aligned flexible optical fibres is used. 2.1 Endoscopes – Some History The concept of endoscopy originated in the early 19th century. Philip Bonzini, an Italian doctor, is credited with the first use of a rigid endoscope in humans in the early 1800’s In 1930, German medical student, Heinrich Lamm was the first person to assemble a bundle of optical fibres to carry an image. Lamm's goal was to look inside inaccessible parts of the body. During his experiments, he reported transmitting the image of a light bulb. However the image was of poor quality. The first endoscope made of optical fibres (fibrescope) was used for viewing the stomach and esophagus at the University of Michigan School of Medicine in 1957. Since then, there has been rapid progress in endoscope development. 2.2 Principles of Optical Fibres Total internal reflection (TIR) is the most important phenomenon for the guiding of light in optical fibres. With TIR light can be completely reflected at the optical fibre surface without any reflective coating. TIR can only occur for light travelling from a more dense to a less dense medium. Thus, in the diagram, the refractive index of the actual optical fibre n1 is greater than that of the cladding n2 . For TIR to occur the angle of incidence (θ) must be greater than the critical angle n1 > n2 Lost Light θ1 θ1 Some Reflected Light θ1< θC θC Critical Angle θ2 θ2 n2 Cladding n1 Optical Fibre All Light Reflected θ2> θC n2 Cladding For light with with θ < θC , much of the light is refracted out of the optical fibre For light with θ = θC , all light is refracted so it just grazes the surface of the fibre For light with θ > θC , light is totally internally reflected and will continue to do so whenever it strikes the fibre’s surface. 2.3 Optical Fibre Construction Usually optical fibres are Cross Section Refractive Index Profile Fibre Type flexible, thin, cylindrical and made of transparent RI materials such as glass Step r n1 n2 n1 and plastic. n2 Index r The most abundant and widespread material used to make optical fibre is RI n1 glass and most often this Graded r is an oxide glass based on n2 n1 Index n2 silica (SiO2) with some r additives. The required properties for an optical fibre are: optical quality, mechanical strength, and flexibility. For these reasons, plastic optical fibres have been made with polymethylmethacrylate (PMMA). They have a “tighter turning circle” than glass fibres. In general, optical fibres have a cylindrical core and are surrounded by a cladding. If both Refractive Indexes, (n1) and (n2) are uniform across their cross sections, the fibre is called a STEP INDEX FIBRE (SI) . If (n1) varies with the core radius (i.e., (n1) gradually decreases from the centre of the core to n2 at the outer radius), it is a GRADED INDEX FIBRE (GRIN). 2.4 Step vs Graded Fibres Cladding Core Fibre Accptance Cone Step Index Fibre In GRIN fibre, the gradient in the refractive index gradually bends the rays back toward the axis. In SI fibre, the light rays zigzag between the core/cladding on each side of the fibre axis. The Fibre Acceptance Cone represents the range of angles for which the incidence angles are greater than the critical angle Core Fibre Accptance Cone Graded Index Fibre 2.5 Fibre Bundles It is impossible for a single fibre to transmit an image. An individual fibre can transmit only a spot of a certain color and intensity. To transmit an image, a large number of single fibres must be aligned and fused together. This means assembly of optical fibres in which the fibres are ordered in exactly the same way at both ends of the bundle to create an image. This type of fibre bundle is called a Coherent Bundle (a) is a low power endoscope (b) is a high power endoscope Incoherent Bundles are groups of fibres which are not ordered at both ends. They are used as light pipes to bring light from an external source down the endoscope to illuminate the area under view. Object seen by endoscope Image projected to eyepiece Object seen by endoscope Image projected to eyepiece 2.6 Endoscope Construction Fibre Optic Endoscopes Endoscopic have a number of “Pictures” basic components: 1. A Coherent Bundle for bringing the image to the eyepiece (or video monitor). 2. An Incoherent Bundle for taking an external light source down the A Ball Bearing endoscope to lodged in the illuminate the viewing oesophagus area. 3. Optional tubes or channels for the passage of air, water, as well as remote control implements such as biopsy forceps or cytology Stomach Ulcer brushes. A piece of dried pork crackling stuck in oesophagus A coin in the stomach 2.7 Endoscope Man An incredible number of endoscopes have been developed for both diagnosis and treatment. Some of the more common are shown on “Endoscope Man” Ultra thin endoscope for investigating blood vessels ARTHROSCOPE Famous in “Aussie Rules” for investigating knee injuries Typical Rigid Endoscope Most commonly used endoscope in general surgery. Chapter 3 Lasers & Laser Treatments 3.0 Laser Basics "Laser" is an acronym for Light Amplification by Stimulated Emission of Radiation. Although there are many types of lasers, all have certain common features. In explaining laser operation, the common ruby laser will be used as an example. In a laser, the lasing medium (the ruby crystal) is so called Ruby Crystal “pumped” to get the electrons of the ruby atoms into an excited Ruby Atoms state. Flash Tube These excited electrons then release their excess energy Mirror as photons of red light. Ruby Atoms Partially silvered mirror These red photons rush back and forth finally exiting the tube as a coherent beam Typically, very intense flashes of light from a flash tube (or from an electrical discharge pump) enter the lasing medium and create a large collection of excitedstate atoms (atoms with higher- energy electrons). 3.1 Laser Types Since their development in 1960, lasers used in medicine and surgery have evolved, and while medical lasers have never become the "magic ray" that some had hoped, they have become powerful and indispensable tools in clinical practice. There are many medical laser systems available today, but they all use the principal of selective photothermolysis which means getting the right amount of the right wavelength of laser energy to the right tissue to damage or destroy only that tissue, and nothing else. Letters etched on a human hair using an Eximer Laser Note: YAG = YttriumAluminium- Garnett KTP = potassium-titanylphosphate Ruby Laser Some of the many medical and surgical lasers in use. 3.1 Laser Types & Treatments Laser CO2 Wavelength (nm) 10,600 Use Surgery (used as a “scalpel”) Er: YAG 2940 “Shaving” of skin to remove wrinkles Ho: YAG 2070 Shaving bones (eg, arthroscopes), kidney stone remov Nd: YAG 1064 Blue/black ink tattoo removal; hair removal Diode 800 to 900 Hair removal; dental surgery Alexandrite 755 Blue/black ink tattoo removal; hair removal Ruby 694 Treatment and removal of moles, freckles, birthmarks Pulsed Dye KTP 577 to 585 532 Argon 488 to 514 Eximer 193 Treatment of port wine birthmarks and spider veins Cutting tissue, red/yellow tattoo ink removal Retinal and ear surgery, removal of birthmarks Laser eye correction Tattoo removal using Nd:YAG laser Chapter 4 Ultrasound 4.0 Ultrasound Basics Definition of Ultrasound Sound consists of travelling pressure waves Speed of sound waves in human tissue: ~ 1500 ms-1. Frequency range: between 2 MHz and 10 MHz Ultrasound is produced using piezo-electric transducers, crystals which change shape under the action of an electric field. Quartz is the most commonly known piezo-electric material. The disk is placed between 2 electrodes and applying a voltage causes the crystal to vibrate. Better performing piezo – electric materials (such as BARIUM TITANATE or LEAD ZIRCONATE) is formed into disks. The crystal will vibrate at the same frequency as the supply voltage, producing sound waves with frequencies between 2 and 10 MHz Variable frequency A.C Voltage: V = VoCos 2π ft The crystal’s vibrations set up Ultrasonic sound waves in the medium around the crystal 4.1 Echo Location Ultrasound or ultrasonography is a medical imaging technique that uses high frequency sound waves and their echoes. The technique is similar to the echolocation used by bats, whales and dolphins, as well as SONAR used by submarines. The ultrasound signals generated as previously described leave the handpiece and are reflected back from various tissues and bones. These reflected waves strike the handpiece causing the piezo electric crystal to contract and expand. This change in shape causes a voltage to be generated which is then processed into a “picture”. 4.2 Ultrasonic Speeds When ultrasonic waves are applied to various body tissues they travel at varying speeds from a low of 1450 ms-1 through fat to a high of 4080 ms-1 through skull bone. Ultrasound image of yolk sac and fetus at 6 week gestation. 4.3 Sound Intensity Profile Field Zones Near Field - the region of a sound beam in which the beam diameter decreases as the distance from the transducer increases. This zone is called the Fresnel (Fra-nel, the s is silent) zone. Beam Properties: Focal Zone - the region where the beam diameter is most concentrated giving the greatest degree of focus. Longitudinal Waves - the wave in which the particle motion is parallel to the direction of the wave travel. A series of longitudinal waves make up the ultrasound beam. Far Field - the region where the beam diameter increases as the distance from the transducer increases. This zone is called the Fraunhoffer zone The best ultrasound images are produced with the transducer operating in the Focal Zone. 4.4 An Ultrasound Examination 1. 2. 3. 4. 5. 6. In ultrasound examination, the following events happen: Below is an Ultrasound image of a High-frequency sound pulses are growing fetus (approximately 12 transmitted into your body using a probe. weeks old) inside a mother's The waves travel into your body and hit a uterus. boundary between tissues (e.g. between This is a side view of the baby, fluid and soft tissue, soft tissue and bone). showing: Some of the sound waves get reflected back to the probe, while some travel on further until they reach another boundary and get reflected. The reflected waves are picked up by the probe and relayed to the machine. The machine calculates the distance from the probe to the tissue or organ (boundaries) using the speed of sound in tissue and the time of the each echo's return (usually on the order of millionths of Legs a second). Neck Head The machine displays the distances and Torso intensities of the echoes on the screen, forming a two dimensional image. 4.5 Ultrasound in 3D In the past few years, ultrasound machines capable of threedimensional imaging have been developed. In these machines, several two-dimensional images are acquired by moving the probes across the body surface or rotating inserted probes. The two-dimensional scans are then combined by specialized computer software to form 3-D images. 3-D ultrasound images Photo courtesy Philips Research The same computer technology is used to produce the famous “dancing babies” images 4.6 Doppler Ultrasound Doppler ultrasound is based upon the Doppler Effect. When the object reflecting the ultrasound waves is moving, it changes the frequency of the echoes, creating a higher frequency if it is moving toward the probe and a lower frequency if it is moving away from the probe. How much the frequency is changed depends upon how fast the object is moving. Doppler ultrasound measures the change in frequency of the echoes to calculate how fast an object is moving. Doppler ultrasound has been used mostly to measure the rate of blood flow through the heart and major arteries. Chapter 5 X Rays 5.0 X rays Wilhelm Conrad Roentgen (1845-1923) Roentgen found that, if the discharge tube is enclosed in a sealed, thick black carton to exclude all light, and if he worked in a dark room, a paper plate covered on one side with the compound barium platinocyanide placed in the path of the rays became fluorescent (gave out a greenish light) even when it was as far as two metres from the discharge tube Following this discovery, he asked his wife to hold her hand in In 1895 Röntgen was studying the path of rays between the tube what happened when an electric and a photographic plate. current was passed through a gas He observed, after developing the of extremely low pressure in plate, an image of his wife's hand apparatus called Crooke’s Tubes. which showed the shadows The thrown by the bones of her hand “first X ray” and that of a ring she was wearing. Because the nature of the new rays was then unknown, he gave them the name X-rays. Later it was shown that they are of the same electromagnetic nature as light, but differ from it only in the higher frequency of their vibration. 5.1 X Ray Production An x-ray machine, like that used in a doctor's or a dentist's office, is really very simple. X-rays are just like any other kind of electromagnetic radiation. They are produced in parcels of Individual Photon energy called photons, just like light. There are two different atomic processes that can produce xray photons. Inside the machine is an x- 1. The first is called Bremsstrahlung, which is a ray tube. An electron gun inside the fancy German name meaning "braking radiation." tube shoots high energy electrons at a target made of heavy atoms, such as 2. The other is called K-shell tungsten. emission. They can both occur X-rays come out because of in heavy atoms like tungsten. atomic processes induced by the energetic electrons shot at the target. 5.2 Types of X Rays 1. Bremsstrahlung. This form of X radiation occurs when the velocity of electrons fired towards the tungsten nucleus changes. 2. K Shell. The K-shell is the lowest energy state of an atom. The incoming electron can give the K shell electron enough energy to knock it out of its energy state. This electron slows down after swinging around the nucleus of a Then, a tungsten electron of higher energy tungsten atom and loses energy by (from an outer shell) can fall into the K-shell. The energy lost by the falling electron radiating x-rays. In this process, a lot of photons of shows up in an emitted x-ray photon. Meanwhile, higher energy electrons fall into different wavelengths are produced, but none of the photons the vacated energy state in the outer shell, has more energy than the electron and so on. had to begin with. K-shell emission produces higher-intensity After emitting the spectrum of xx-rays than Bremsstrahlung, and the x-ray ray radiation the original electron photon comes out at a single wavelength. is slowed down or stopped. 5.3 X Ray Diagnostics X rays are most commonly used for investigation of the skeleton, the diagnosis of broken bones and the display of the effects of trauma on the body. Steel spikes in wrist Shotgun Pellets Shattered Femur Broken Femur Chapter 6 CT Scans 6.0 CT Scans One of the first dedicated head CT scanners, in 1974 CT or Computerised Tomography, also know as CAT or Computerised Axial Tomography Scans use an X-ray source coupled with an X-ray detector on the opposite side of the body, which are rotated together to give a crosssectional picture of the body at one level or cut. CT scans are of greatest value for showing physical changes in tissue, although small tumours may be missed if absorption properties are like those of normal tissue. COMPUTED AXIAL TOMOGRAPHY CAT Scan of the Pelvic Region • Images the body using X-rays. • Initial research: 1960s • Applied research: 1970s-80s • X-rays are sent through the body at various angles, resulting in cross-sectional images. 6.1 CT - History Tomography is from the Greek word "tomos" meaning "slice" or "section" and graphia meaning "describing". CT was invented in 1972 by British engineer Godfrey Hounsfield of EMI Laboratories, England, and independently by South African born physicist Allan Cormack of Tufts University, Massachusetts. CT image of a normal brain using a state-of-the-art CT system and a 512 x 512 matrix image. The first clinical CT scanners were installed between 1974 and 1976. The original systems were dedicated to head imaging only, but "whole body" systems with larger patient openings became available in 1976. CT became widely available by about 1980. There are now 30,000 installed worldwide. The first CT scanner took several hours to acquire the raw data for a single scan or "slice" and took days to reconstruct a single image from this raw data. The latest multi-slice CT systems can collect up to 4 slices of data in about 350 ms and reconstruct a 512 x 512-matrix image from Original CT image from scanner millions of data points in less than a second. An circa 1975. This image is a coarse entire chest (forty 8 mm slices) can be scanned 128 x 128 matrix, showing a slice of in five to ten seconds using the most advanced the brain multi-slice CT system. Chapter 7 PET Scans 7.1 PET Scans Positron Emission Tomography, or PET, scanning is an imaging technique that uses radioactive positrons (positively charged particles) to detect subtle changes in the body's metabolism and chemical activities. PET Scanner Human Brain Performing A PET scan provides a color-coded image of a body organ in function rather than its structure. During a PET scan, a positron-producing radioisotope called a tracer is either injected into a vein or inhaled as a gas. This tracer is typically a chemical that is normally found in the body (carbon, nitrogen, oxygen) that has been altered to allow it to emit positrons. Once the tracer enters the body, it travels through the bloodstream to a specific target organ, such as the brain or heart. There the tracer emits positrons, which collide with electrons (negatively charged particles), producing gamma rays (similar to X-rays). These gamma rays are detected by a ringed-shaped PET scanner and analyzed by a computer to form an image of the target organ's metabolism or other functions. Chapter 8 MRI Scans 8.0 MRI - Basic Operation Typical MRI Scanner MRI (Magnetic Resonance Imaging) started out as a tomographic imaging (CT) technique, that is, it produced an image of a thin slice through the human body. MRI has advanced beyond a tomographic imaging technique to a volume imaging technique. The human body is primarily fat and water. Both fat and water have many hydrogen atoms which make the human body roughly 63% hydrogen atoms. MRI takes advantage of the fact that the nuclei of certain atoms, hydrogen and phosphorous, in particular, behave like a magnet. When the field is turned-off, the nuclei against the field spin and release a characteristic radiofrequency photon emission. In the absence of an external magnetic field, these hydrogen atoms are not lined up in any particular direction. When those atoms are placed in a strong magnetic field, their nuclei align the axis of spin either with or against the direction of the field. These emissions are collected and fed into a computer which produces the MRI image. 8.1 MRI Scans MRI scanners are good at looking at the non-bony parts or "soft tissues" of the body. In particular, the brain, spinal cord and nerves are seen much more clearly with MRI than with regular x-rays and CAT scans. Also, muscles, ligaments and Knee MRI Colour Enhanced tendons are seen quite well so that MRI scans are commonly used to look at knees and shoulders following injuries. An advantage of MRI is the radio waves used are a trillion times less energetic (and potentially less damaging) than X rays. Neck Brain Kidneys The Magnetic Fields used by MRI’s are about 1 million times stronger than the Earth’s field. So beware funny things can happen when these machines are switched on ! A disadvantage of MRI is it’s higher cost compared to a regular x-ray or CAT scan. Chapter 9 Image Interpretation 9.1 Image Interpretation: X Rays Bullet lodged in shoulder Coin lodged in child’s oesophageus Needle in child’s foot Broken Ulna Bone in forearm 9.2 Image Interpretation: CT Scans Brain Scan Cuts due to MVA Liver Scan Stroke – Bleeding into brain Brain Scan Calf (Lower Leg) Scan Sub Dural Haematoma – Bleeding inside skull due to head injury from MVA DVT (Deep Vein Thrombosis) Economy Class Syndrome 9.3 Image Interpretation: MRI Brain Scan Brain Tumor Ruptured Cruciate Ligaments Knee Scan Heart Scan Movie Spinal Scan Breast Scan Ruptured Disc Actual Colour Enhanced Breast Cancer 9.4 Image Interpretation: PET Scans Whole Body Brain scan – growing child Scan Brain Scan These days, scans are “colour coded” making them much easier to “read”. Dark Spots are cancers Scans comparing brain activity during various activities with the same brain in its resting state. Shows the remarkable increase in brain activity during the 1st year of life Resting Brain 9.5 Image Interpretation: Ultrasound Twins shown in colour enhanced scan 3-D scan of fetus with a Clubfoot Information sources: •Uranium Information Centre (UIC) •ANSTO •www.sciencephoto.com/htm •www.nlm.nih.gov/ •www.spine-inc.com/ •www.epub.org •www.cancer-therapy-options.com Ollie Leitl 2003