* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download 80-800 - Detex Corporation
Electric battery wikipedia , lookup
Wireless power transfer wikipedia , lookup
Standby power wikipedia , lookup
Electrical substation wikipedia , lookup
Three-phase electric power wikipedia , lookup
Pulse-width modulation wikipedia , lookup
Power inverter wikipedia , lookup
History of electric power transmission wikipedia , lookup
Electrification wikipedia , lookup
Audio power wikipedia , lookup
Electric power system wikipedia , lookup
Immunity-aware programming wikipedia , lookup
Buck converter wikipedia , lookup
Earthing system wikipedia , lookup
Power engineering wikipedia , lookup
Voltage optimisation wikipedia , lookup
Power electronics wikipedia , lookup
Amtrak's 25 Hz traction power system wikipedia , lookup
Alternating current wikipedia , lookup
Power supply unit (computer) wikipedia , lookup
Power over Ethernet wikipedia , lookup
Power supply wikipedia , lookup
Switched-mode power supply wikipedia , lookup
103156, APRIL 17, 2007 Detex Corporation, 302 Detex Drive, New Braunfels, Texas 78130-3045 (830)629-2900 / 1-800-729-3839 / Fax (830)620-6711 E-MAIL: [email protected] INTERNET: www.detex.com INSTRUCTIONS FOR 80-800 80-800 FILTERED AND REGULATED POWER SUPPLY 1.0 AMP @ 24 VOLTS DC Optional Battery p/n 70-24B (24 volt, 4.5 Ah) 103156 Page 1 80-800 STANDARD POWER SUPPLY GREEN WHITE 120VAC BLACK JUMPER PLATE (SEE #2 BELOW) Wires to optional battery backup. Battery p/n: 70-24B (24 volt, 4.5 Ah) DC power out (SEE #6 BELOW) N/C Fire Alarm Loop DETEX MODEL 80-800 STANDARD POWER SUPPLY CONNECTION DIAGRAM AND INSTRUCTIONS The 80-800 is a regulated and filtered power supply. It has a selectable output voltage of either 12 or 24 volts DC. For Detex systems always select 24 volts DC. Refer to the drawing of the power supply for connections and adjustments. All connections and adjustment must be made with the power supply de-energized AND main power switch (item 3) in the OFF position. 1: Main power connection. Observe correct terminal connections. Color code requires connections made per NFPA72. Leave circuit de-energized while installing and servicing unit. 2: Fire loop control. The fire loop control is bypassed with a factory jumper unless the power supply is supplied with a delayed egress device. If not used with delayed egress device proceed to step 3. With delayed egress devices, the jumper plate is not provided, and connections to the building fire alarm system are required. Connect the building fire system closed relay to the (-) and C terminals. The power supply will operate normally as long as the connection between the (-) and (C) is maintained. When the building fire alarm system opens the circuit, the power supply de-energizes the output voltage. Fire loop uses 24 volt sense voltage. Note: Each power supply should have an independent fire alarm relay. 3: Main ON-OFF switch. This switch can be used to de-energize the power supply for service and adjustments. High voltage is still present inside the enclosure as long as the main power feed is energized, so caution should still be used when service is performed using this switch. 4: 1 Amp circuit breaker. This is intended to protect the device against high current loads and is part of the AC input circuit. It is a thermal device and can be reset once the cause of the overload is corrected. 5: Output voltage select switches. These must both be set to the 24 volt position. They should be preset at the factory and require no adjustment. If they need adjustment, de-energize the unit first. 6: Output terminals. Outputs 24 volts at 1 amp maximum. The output is protected by a PTC thermally resetable fuse element. The fuse will reset once the cause of the overload is found and corrected. Observe correct polarity when making connections. 103156 Page 2 7: Optional battery backup connections. This output is intended for lead acid batteries and is also at 24 volts. Typically, two 12 volt batteries are connected in series for this application. Approximate battery life is charted on the label inside the cover of the power supply. RECOMMENDED WIRE SIZES: WIRE GAUGE MAXIMUM LENGTH OF TWO CONDUCTOR CABLE 20 AWG 10 FEET 18 AWG 40 FEET 80-800 Power Supply with Detex Delayed Egress device GREEN WHITE 120VAC BLACK SEE 2 Wires to optional battery backup Fire Alarm Loop To Exit Device Door #1 DETEX RECOMMENDS THE POWER SUPPLY BE LOCATED WITHIN 40 FEET OF THE DEVICE To Exit Device Door #2 (if req'd) Closed Fire Alarm Loop (must be supplied) From (-) terminal to pin #2 on exit device From (+) terminal to pin #1 on exit device BLK WHT BLK WHT 1 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 7 8 9 10 11 12 INSTALL JUMPER WIRE FROM TERMINAL 3 TO TERMINAL 4 AS SHOWN 9V Alkaline Battery To Exit Device(s) To disable the low-battery indication, disconnect AC power and battery before cutting "DB" jumper wire. (PC BOARD ASSEMBLY INSIDE DELAYED EGRESS DEVICE) 103156 Page 3