Gas leak detectors RV 130.01-05-12 Wall mounted gas detector For operating normally open or normally closed low voltage 12 Vdc manual reset solenoid valves or mains powered 230 V solenoid valves. Semiconductor electronic sensor or optional precalibrated ARTICLE CODE MOD. RV130.01M B B RV130.05M* A MEHANE A RV130.12M* RV130.01G B LPG RV130.05G* A RV130.12G* Domestic gas detector without solenoid valve connection Gas detection unit with 230 volt solenoid valve control Gas detection unit with 12 volt solenoid valve control Domestic gas detector without solenoid valve connection Gas detection unit with 220 volt solenoid valve control Gas detection unit with 12 volt solenoid valve control *One local or remote RV 130.04 sensor can be included in the system and combined with a number of cascaded detectors. RV 130.04 catalytic module. Continuous functioning diagnostics. Conforms to EN 50194. TECHNICAL CHARACTERISTICS Power supply 230 Vac +/-10% 50/60Hz Max. 3.5VA consumption Solenoid valve Via 8 A relay control ** Semiconductor Sensor electronic Green ACTIVE Device switched on signal Yellow FAULT Device error signal Red ALARM Device alarm status signal Acoustic 85 dB buzzer signal Functioning Control button on device keys Index of IP 42 protection Colour RAL 9001 UL94 Casing 145x67x47 Catalytic module Optional ** Model A only Wall mounted gas detector Local or remote sensor. Temperature-compensated, semiconductor electronic sensor. Continuous functioning diagnostics. Conforms to EN 50194. RV130.04M RV130.04G LPG METHANE ARTICLE CODE Can be connected to article RV130.05/12M Can be connected to article RV130.05/12G TECHNICAL CHARACTERISTICS Power supply from RV130.05/12 (G/M) Max. 1VA consumption Solenoid valve control Semiconductor Sensor electronic Green ACTIVE Device switched on signal Yellow FAULT Device error signal Red ALARM Device alarm status signal Acoustic 85 dB buzzer signal Index of IP 42 protection Colour RAL 9001 UL94 Casing 103x75x32 [A·02] Gas leak detectors LOW COST VERSION Gas detector for controlling 230 Vac mains powered manual and automatic reset solenoid valves. Temperature-compensated, semiconductor electronic sensor. Continuous functioning diagnostics. 85 dB piezoelectric buzzer. Visual display of active/error/alarm status. The RV130.30 is specially designed to protect domestic environments against accidental leaks of methane, LPG or town gas. Provided a few simple positioning and installation rules are followed, the device guarantees perfect stability and safety over time. Permits monitoring of single areas, and controls mains powered normally open or normally closed automatic reset solenoid valves. Conforms to the latest design standards and to CEI UNI EN 50194 standard governing gas detectors. RV131.06M Wall mounted gas detector Index of protection IP 42 Colour Casing RAL 9001 UL94 103x75x32 ARTICLE CODE RV130.04M METHANE Wall mounted methane or LPG domestic gas detector TECHNICAL CHARACTERISTICS 230Vac +/-10% Power supply 50/60Hz Max. 1,5VA consumption Solenoid valve Via 8 A relay control Semiconductor Sensor electronic Green ACTIVE Device switched on signal Yellow FAULT Device error signal Red ALARM Device alarm status signal Acoustic 85 dB buzzer signal Functioning No test RV130.04G LPG RV 130.30 Can be connected only to 230 V NO/NC solenoid valves. TECHNICAL CHARACTERISTICS Power supply 12 V cc +/- 10% Consumption 2W @ 12V. Relay contact capacity The RV131.06M uses an internal sensor to detect either methane or LPG, depending on functioning mode. Sensitivity is calibrated to 10% of the LEL. The device has a built-in relay to operate solenoid valves, sirens and other warning and alarm devices. A jumper inside the device can be set for pulsed or continuous relay functioning. Because the relay is voltage free, more than one detector can be installed on a single solenoid valve to monitor a number of environments. A special electronic circuit verifies the efficiency of the detection sensor and gives a visual warning signal in the event of an error. Its technical specifications make the RV131.06M ideal for use in civil environments, campers and boats. Conforms to EN 50194, EN 61779 (replaces EN50054), and EMC (EN50270). [A·02] Explosive gas sensor Explosive gas alarm threshold 10 A 250 V resistive -5 A 30 Vdc resistive Semiconductor 10% of the LEL Detector threshold for explosive gases Immediate Visual and acoustic alarm signalling LED and buzzer Sensor failures detected by diagnostic circuit Operating temperature range Operating humidity range Electromagnetic compatibility External index of protection Mounting Casing material Overall dimensions power failure, short circuit or decay -10°C to +40°C 0 to 90% RH, noncondensing CE reference standard EN 50270 IP30 External wall mounting Self-extinguishing ABS 112x50x36 Gas leak detectors RVK Wall mounted gas detector kit RVK05 The box contains everything you need to create a complete and reliable domestic gas detection system. Available for 1/2” or 3/4” NO/NC solenoid valves. RVK30 METHANE LPG METHANE LPG ARTICLE CODE RVK05.G11 RVK05.G12 RVK05.G21 RVK05.G22 RVK05.M11 RVK05.M12 Conforms to CEI UNI EN 50194. GAS DETECTOR SERIES RV130.05G SOLENOID VALVE SERIES EV131.11 1/2” NO EV131.12 3/4” NO EV131.29 1/2” NC EV131.30 3/4” NC EV131.11 1/2” NO VOLTS TECHNICAL CHARACTERISTICS RVK05 Power supply 230Vac +/-10% 50/60Hz Max. consumption 3.5 VA Solenoid valve control Via 8 A relay Sensor Semiconductor electronic Green ACTIVE signal Device switched on Yellow FAULT signal Device error Red ALARM signal Device alarm status Acoustic signal 85 dB buzzer Functioning test Test button on device RVK30 1.5 VA 3/4” NO EV131.12 1/2” NC EV131.29 RVK05.M22 3/4” NC EV131.30 RVK30.G11 1/2” NO EV131.11 RVK30.G12 3/4” NO EV131.12 1/2” NC EV131.29 RVK30.G22 3/4” NC EV131.30 RVK30.M11 1/2” NO EV131.11 RVK30.M12 3/4” NO EV131.12 Index of protection IP 42 1/2” NC EV131.29 Colour RAL 9001 UL94 3/4” NC EV131.30 Casing 145x67x47 RVK05.M21 RVK30.G21 RVK30.M21 RV130.05M RV130.30G RV130.30M RVK30.M22 230 RV131.04M No 103x75x32 Wall mounted gas detector This gas detector has been designed and made in compliance with European standards to detect toxic and/or explosive gases. A built-in microprocessor provides complete detection and control functionality and makes this device particularly suitable for domestic use. The device can detect methane with a trip sensitivity of 10% of the LEL as well carbon monoxide. CO can be detected when a maximum concentration is exceeded or when lower concentrations persist in the environment and could build up in the body to create a risk to health. The device’s built-in relay can be used to operate solenoid valves, sirens and other warning and alarm devices. Clever technical solutions make this detector extremely versatile, reliable, precise and safe to use. Because the relay is voltage free, more than one detector can be installed on a single solenoid valve to monitor a number of environments. A special electronic circuit monitors the efficiency of the sensors and signals any error condition. The outer casing boasts an index of protection of IP42. Conforms to standards: EN 50194 for explosive gases EN 50291 for toxic gases - CO TECHNICAL CHARACTERISTICS Use Domestic type A Detection Explosive and toxic gases Control system microprocessor External index IP42 of protection [A·02]