Gas leak detectors
RV 130.01-05-12
Wall mounted gas detector
For operating normally open or normally
closed low voltage 12 Vdc manual
reset solenoid valves or mains powered
230 V solenoid valves. Semiconductor
electronic sensor or optional precalibrated
ARTICLE
CODE
MOD.
RV130.01M
B
B
RV130.05M*
A
MEHANE
A
RV130.12M*
RV130.01G
B
LPG
RV130.05G*
A
RV130.12G*
Domestic gas detector without solenoid
valve connection
Gas detection
unit with 230 volt
solenoid valve
control
Gas detection
unit with 12 volt
solenoid valve
control
Domestic gas detector without solenoid
valve connection
Gas detection
unit with 220 volt
solenoid valve
control
Gas detection
unit with 12 volt
solenoid valve
control
*One local or remote RV 130.04 sensor can be included
in the system and combined with a number of cascaded
detectors.
RV 130.04
catalytic module. Continuous functioning
diagnostics.
Conforms to EN 50194.
TECHNICAL CHARACTERISTICS
Power supply
230 Vac +/-10% 50/60Hz
Max.
3.5VA
consumption
Solenoid valve
Via 8 A relay
control **
Semiconductor
Sensor
electronic
Green ACTIVE
Device switched on
signal
Yellow FAULT
Device error
signal
Red ALARM
Device alarm status
signal
Acoustic
85 dB buzzer
signal
Functioning
Control button on device
keys
Index of
IP 42
protection
Colour
RAL 9001 UL94
Casing
145x67x47
Catalytic
module
Optional
** Model A only
Wall mounted gas detector
Local or remote sensor.
Temperature-compensated, semiconductor
electronic sensor. Continuous functioning
diagnostics.
Conforms to EN 50194.
RV130.04M
RV130.04G
LPG METHANE
ARTICLE
CODE
Can be connected to article
RV130.05/12M
Can be connected to article
RV130.05/12G
TECHNICAL CHARACTERISTICS
Power supply
from RV130.05/12 (G/M)
Max.
1VA
consumption
Solenoid valve
control
Semiconductor
Sensor
electronic
Green ACTIVE
Device switched on
signal
Yellow FAULT
Device error
signal
Red ALARM
Device alarm status
signal
Acoustic
85 dB buzzer
signal
Index of
IP 42
protection
Colour
RAL 9001 UL94
Casing
103x75x32
[A·02]
Gas leak detectors
LOW COST VERSION
Gas detector for controlling 230 Vac mains
powered manual and automatic reset solenoid valves.
Temperature-compensated, semiconductor
electronic sensor. Continuous functioning
diagnostics. 85 dB piezoelectric buzzer.
Visual display of active/error/alarm status.
The RV130.30 is specially designed to protect domestic environments against accidental leaks of methane, LPG or town gas.
Provided a few simple positioning and
installation rules are followed, the device
guarantees perfect stability and safety over
time.
Permits monitoring of single areas, and
controls mains powered normally open or
normally closed automatic reset solenoid
valves.
Conforms to the latest design
standards and to CEI UNI EN 50194
standard governing gas detectors.
RV131.06M
Wall mounted gas detector
Index of protection
IP 42
Colour
Casing
RAL 9001 UL94
103x75x32
ARTICLE
CODE
RV130.04M
METHANE
Wall mounted methane or LPG domestic gas detector
TECHNICAL CHARACTERISTICS
230Vac +/-10%
Power supply
50/60Hz
Max.
1,5VA
consumption
Solenoid valve
Via 8 A relay
control
Semiconductor
Sensor
electronic
Green ACTIVE
Device switched on
signal
Yellow FAULT
Device error
signal
Red ALARM
Device alarm status
signal
Acoustic
85 dB buzzer
signal
Functioning
No
test
RV130.04G
LPG
RV 130.30
Can be connected only
to 230 V NO/NC solenoid
valves.
TECHNICAL CHARACTERISTICS
Power supply
12 V cc +/- 10%
Consumption
2W @ 12V.
Relay contact
capacity
The RV131.06M uses an internal sensor to
detect either methane or LPG, depending on functioning mode. Sensitivity is
calibrated to 10% of the LEL. The device
has a built-in relay to operate solenoid
valves, sirens and other warning and alarm
devices. A jumper inside the device can be
set for pulsed or continuous relay functioning. Because the relay is voltage free, more
than one detector can be installed on a
single solenoid valve to monitor a number
of environments. A special electronic circuit verifies the efficiency of the detection
sensor and gives a visual warning signal in
the event of an error.
Its technical specifications make the
RV131.06M ideal for use in civil environments, campers and boats.
Conforms to EN 50194, EN 61779
(replaces EN50054), and EMC
(EN50270).
[A·02] Explosive gas
sensor
Explosive gas alarm
threshold
10 A 250 V resistive
-5 A 30 Vdc resistive
Semiconductor
10% of the LEL
Detector threshold
for explosive gases
Immediate
Visual and acoustic
alarm signalling
LED and buzzer
Sensor failures
detected by
diagnostic circuit
Operating
temperature range
Operating humidity
range
Electromagnetic
compatibility
External index of
protection
Mounting
Casing material
Overall dimensions
power failure, short
circuit or decay
-10°C to +40°C
0 to 90% RH, noncondensing
CE reference standard
EN 50270
IP30
External wall mounting
Self-extinguishing ABS
112x50x36
Gas leak detectors
RVK
Wall mounted gas detector kit
RVK05
The box contains everything you need to
create a complete and reliable domestic
gas detection system.
Available for 1/2” or 3/4” NO/NC solenoid
valves.
RVK30
METHANE
LPG
METHANE
LPG
ARTICLE CODE
RVK05.G11
RVK05.G12
RVK05.G21
RVK05.G22
RVK05.M11
RVK05.M12
Conforms to CEI UNI EN 50194.
GAS DETECTOR SERIES
RV130.05G
SOLENOID VALVE SERIES
EV131.11
1/2” NO
EV131.12
3/4” NO
EV131.29
1/2” NC
EV131.30
3/4” NC
EV131.11
1/2” NO
VOLTS
TECHNICAL
CHARACTERISTICS
RVK05
Power supply
230Vac +/-10% 50/60Hz
Max. consumption
3.5 VA
Solenoid
valve control
Via 8 A relay
Sensor
Semiconductor electronic
Green
ACTIVE
signal
Device switched on
Yellow
FAULT signal
Device error
Red ALARM
signal
Device alarm status
Acoustic
signal
85 dB buzzer
Functioning
test
Test button
on device
RVK30
1.5 VA
3/4” NO
EV131.12
1/2” NC
EV131.29
RVK05.M22
3/4” NC
EV131.30
RVK30.G11
1/2” NO
EV131.11
RVK30.G12
3/4” NO
EV131.12
1/2” NC
EV131.29
RVK30.G22
3/4” NC
EV131.30
RVK30.M11
1/2” NO
EV131.11
RVK30.M12
3/4” NO
EV131.12
Index of
protection
IP 42
1/2” NC
EV131.29
Colour
RAL 9001 UL94
3/4” NC
EV131.30
Casing
145x67x47
RVK05.M21
RVK30.G21
RVK30.M21
RV130.05M
RV130.30G
RV130.30M
RVK30.M22
230
RV131.04M
No
103x75x32
Wall mounted gas detector
This gas detector has been designed and
made in compliance with European standards to detect toxic and/or explosive
gases.
A built-in microprocessor provides complete detection and control functionality
and makes this device particularly suitable
for domestic use. The device can detect
methane with a trip sensitivity of 10% of
the LEL as well carbon monoxide. CO can
be detected when a maximum concentration is exceeded or when lower concentrations persist in the environment and could
build up in the body to create a risk to
health.
The device’s built-in relay can be used to
operate solenoid valves, sirens and other
warning and alarm devices. Clever technical solutions make this detector extremely
versatile, reliable, precise and safe to use.
Because the relay is voltage free, more
than one detector can be installed on a
single solenoid valve to monitor a number
of environments.
A special electronic circuit monitors the
efficiency of the sensors and signals any
error condition. The outer casing boasts an
index of protection of IP42.
Conforms to standards:
EN 50194 for explosive gases
EN 50291 for toxic gases - CO
TECHNICAL CHARACTERISTICS
Use
Domestic type A
Detection
Explosive and toxic gases
Control system microprocessor
External index
IP42
of protection
[A·02]