* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download SpectrAlert Selectable Output Series Wall Speaker/Strobes for Fire
Power over Ethernet wikipedia , lookup
Electric power system wikipedia , lookup
Ground (electricity) wikipedia , lookup
Electrical ballast wikipedia , lookup
Loudspeaker enclosure wikipedia , lookup
Power inverter wikipedia , lookup
Current source wikipedia , lookup
Immunity-aware programming wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Transmission line loudspeaker wikipedia , lookup
Electrical substation wikipedia , lookup
Pulse-width modulation wikipedia , lookup
Three-phase electric power wikipedia , lookup
Loudspeaker wikipedia , lookup
Solar micro-inverter wikipedia , lookup
Power engineering wikipedia , lookup
Schmitt trigger wikipedia , lookup
Distribution management system wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Audio power wikipedia , lookup
History of electric power transmission wikipedia , lookup
Power MOSFET wikipedia , lookup
Voltage regulator wikipedia , lookup
Power electronics wikipedia , lookup
Buck converter wikipedia , lookup
Stray voltage wikipedia , lookup
Surge protector wikipedia , lookup
Voltage optimisation wikipedia , lookup
Alternating current wikipedia , lookup
Switched-mode power supply wikipedia , lookup
INSTALLATION AND MAINTENANCE INSTRUCTIONS SpectrAlert Selectable Output Series Wall Speaker/Strobes for Fire Protective Signaling Systems 6581 Kitimat Rd., Unit #6, Mississauga, Ontario, L5N 3T5 1-800-SENSOR2, FAX: 905-812-0771 www.systemsensor.ca For use with models: SP2R1224MCA-25, SP2R1224MCA-70, SP2W1224MCA-25, SP2W1224MCA-70. Add suffix ‘-F’ for French, ‘-B’ for Bilingual. Specifications: Speaker Mechanical Input Terminals: 12 to 18 AWG (3.31 to 0.82 mm2) Speaker Size: 4 inches (101 mm) Overall Dimensions:8.25″ × 4.9″ CAUTION 12-volt candela selections when model MDLA synchronous module is used: 10.5 to 17.5 volts 24-volt candela selections when model MDLA synchronous module is used: 17 to 33 volts Flash Rate: 1 flash per second Selectable Light Outputs: 12 Volt Application – 15 and 15/75 candela. 24 Volt Application – 15, 15/75, 30, 75, and 110 candela. All candelas are selectable via a manual slide switch. 15/75 is listed at 15 candela per UL 1971 but will provide 75 candela on axis (straight ahead). 15, 30, 75, and 110 are rated for that candela. Note for Strobes: Do not exceed 1) 16-33 or 9.5-17.5 Voltage range limit, 2) Maximum number of 70 strobe lights when connecting the MDLA Sync module with a maximum line impedance of 4 Ohms per loop and 3) Maximum line impedance as required by the fire alarm control manufacturer. Electrical Voltage Input: 25 volts or 70.7 volts (nominal) Frequency Range: 400 – 4000 Hz 1 Power: ⁄4, 1⁄2, 1 and 2 Watts Operating Temperature Range:32° to 120°F (0° to 49°C) Listings: ULC Specifications: Strobe 12 or 24 Volt Operation: Automatic electronic selection feature. Operating Voltage Range Limits: 12-Volt candela selections:9.5 to 17.5 Volts DC or FWR 24-Volt candela selections:16 to 33 Volts DC or FWR The series SP2R1224MCA and SP2W1224MCA strobes incorporate a new patent-pending voltage booster design that has a more consistent flash bulb voltage over the range of the candela selections. The benefit to the customer is a high quality strobe device. NOTICE: This manual shall be left with the owner/user of this equipment. currents do not exceed the current capability of the panel. Calculations are based on using the device current found in Table 2 and must be the current specified for the type of panel power supply used. General Description The SpectrAlert SP2 series speaker/strobes are designed to meet the requirements of most agencies governing these devices, including: NFPA, ADA, The National Fire Alarm Code, ULC. Also, check with your local Authority Having Jurisdiction for other codes or standards that may apply. Wire Sizes The designer must be sure that the last device on the circuit has sufficient voltage to operate the device within its rated voltage. When calculating the voltage available to the last device, it is necessary to consider the voltage drop due to the resistance of the wire. The thicker the wire, the less the voltage drop. Generally, for purposes of determining the wire size necessary for the system, it is best to consider all of the devices as “lumped” on the end of the supply circuit (simulates “worst case”). The SpectrAlert SP2 series speakers can be operated with distribution amplifiers having an output voltage of either 25 volts or 70.7 volts. The speakers operate at any one of four input power levels. The output sound level is selected at the time of installation, but can be changed, if necessary. Typical wire size resistance: 18 AWG solid: Approximately 16 AWG solid: Approximately 14 AWG solid: Approximately 12 AWG solid: Approximately The speaker is also equipped with a capacitive input to allow for DC supervision. The SpectrAlert SP2 series strobe can be installed in systems using 12 or 24-volt panels having DC or full-wave rectified (FWR) power supplies. The strobes can also be installed in applications requiring synchronization (module MDL or compatible equivalent required) or applications that do not require synchronization (no module required). ohms/1,000 ohms/1,000 ohms/1,000 ohms/1,000 ft. ft. ft. ft. Example: Assume you have 10 devices on a zone and each requires 50 mA average and 2000 Ft. of 14 AWG wiring (total length=outgoing+return). The voltage at the end of the loop is 0.050 amps per device × 10 devices × 3 ohms/1,000 ft. × 2000 ft =3 volts drop. Power Supply Considerations For Strobes Panels typically supply DC filtered voltage or FWR (fullwave rectified) voltage. The system design engineer must calculate the number of units used in a zone based on the type of panel supply. Be certain the sum of all the device D900-29-00 8 5 3 2 The same number of devices using 12 AWG wire will produce only 2 volts drop. The same devices using 18 AWG wire will produce 8 volts drop. Consult your panel manu1 I56-2564-000 facturer’s specifications, as well as SpectrAlert’s operating voltage range to determine acceptable voltage drop. Note: If class “A” wiring is installed, the wire length may be up to 4 times the single wire length in this calculation. Figure 2. Speaker Voltage and Power Selection: Installation All wiring must be installed in compliance with the Canadian Electrical Code (NEC) and applicable local codes as well as special requirements of the authority having jurisdiction, using the proper wire size. This also includes all applicable NFPA Standards, ANSI/UL 1480, UL 1971. CORRECT SPEAKER 2W 2W 1W 1W SW1 SW1 Electrical 1. Connect the speaker/strobe as shown in Figure 1. Keep in mind that even though the speaker and strobe are a single mechanical unit, they are electrically independent and require separate power sources. NOTE: Do NOT loop electrical wiring under terminal screws. Wires connecting the device to the control panel must be broken at the device terminal connection in order to maintain electrical supervision. Figure 1. Electrical connections: INCORRECT 1/2W 1/2W 1/4W 1/4W A0102-00 Table 1. Sound levels for each transformer power tap: ULC Anechoic (dBA @ 10 ft.) STROBE 2W 1W 1/2 W 1/4 W 91 88 85 82 A0103-00 TO NEXT SPEAKER OR EOL INPUT FROM AMPLIFIER INPUT FROM POWER SUPPLY CAUTION Signal levels exceeding 130% rated signal voltage can damage the speaker. Consequently, an incorrect tap connection may cause speaker damage. This means that if a 25V speaker is used when a 70.7V amplifier is being used, speaker damage may result. Therefore, be sure to select the proper speaker/taps for the amplifier voltage/input power level combination being used. TO NEXT STROBE OR EOL NOTE: Supply power for strobe must be continuous for proper operation. 2. See Figure 2 as an example of how to select a 1/4 Watt input. Table 1 lists the ULC reverberant and anechoic output sound levels for each power tap on the SP2 series speaker/strobes. A0101-00 Table 2. Strobe current draw measurements – 12/24 Volt applications: NOTE: All 12V strobe candelas were tested only at the 9.5-17.5 Volt-FWR/DC limits. All 24V strobe candelas were tested only at the 16-33 Volt-FWR/DC limits. This does not include the 80% low end or 110% high end voltage limits. Average Mean Method: 9.5V Candela 15 15/75 30 75 110 AVERAGE MEAN CURRENT (mA) At 12V At 24V 12V 17.5V 16V 24V DC FWR DC FWR 99 119 NA NA NA 84 111 NA NA NA 65 79 NA NA NA DC FWR DC 59 49 44 52 69 58 52 62 NA NA NA 80 NA NA NA 144 NA NA NA 194 FWR DC FWR 47 55 87 130 171 42 48 57 100 130 38 43 68 90 118 33V 9.5V PEAK CURRENT (mA) At 12V At 24V 12V 17.5V 16V 24V DC FWR DC FWR DC FWR 40 44 53 81 103 38 41 58 72 93 221 243 NA NA NA 227 578 NA NA NA 174 175 NA NA NA 159 254 NA NA NA DC 155 147 NA NA NA FWR DC FWR 135 194 NA NA NA 151 157 193 305 366 137 206 194 534 506 DC 129 129 159 251 314 33V 9.5V IN RUSH CURRENT (mA) At 12V At 24V 12V 17.5V 16V 24V FWR DC FWR DC FWR DC FWR DC 165 170 206 430 370 301 330 322 518 434 62 47 NA NA NA 79 61 NA NA NA 87 91 129 91 79 93 121 83 NA NA NA 89 NA NA NA 77 NA NA NA 95 133 127 155 217 270 49 51 NA NA NA FWR DC FWR 117 107 119 115 113 DC 133 123 131 119 131 33V FWR DC FWR 177 171 175 175 181 265 253 253 255 247 189 185 177 183 181 Average RMS Method: 9.5V Candela 15 15/75 30 75 110 AVERAGE RMS CURRENT (mA) At 12V At 24V 12V 17.5V 16V 24V DC FWR DC FWR DC 105 124 NA NA NA 110 149 NA NA NA 74 89 NA NA NA 56 63 60 65 67 72 72 75 NA NA 92 111 NA NA 161 161 NA NA 210 209 D900-29-00 77 89 NA NA NA FWR DC FWR DC FWR 47 55 67 117 150 58 64 96 121 151 33V DC FWR 44 49 59 94 120 59 64 89 106 131 2 I56-2564-000 Candela Selections: Figure 3. For strobe candela selections, adjust slide switch located on the rear of the product while watching the viewing window on the side of the reflector. attach the speaker/strobe to the back box. Do not insert any mounting screws at this point. B.Use two 8-32 × 13/4″ pan head screws to attach the speaker to the back box with extension ring with prethreaded holes. C.Plug the remaining two holes that will not be used for attachment with the plugs provided. NOTE: Two drywall screws (provided) may be used to fasten the mounting plate to the wall. To use the drywall screws, it will be necessary to first remove the strobe and hinge the strobe module away from the mounting plate (Fig. 7). Figure 4: Reversible strobe module Viewing Window A0133-00 NOTE: SpectrAlert Selectable Output strobes, set at 15 and 15/75cd, automatically work on both 12V and 24V power supplies. NOTE: The strobe is not listed for 12V operating voltages when set to 30, 75 or 110 candela. Use only those settings marked as OK in this chart: A0105-01 Permissible Candela Settings: Candela Setting Figure 5: Flush mount back box Operating Voltage 12V 24V 15 OK OK 15/75 OK OK 30 OK 75 OK 110 OK 4-INCH BACK BOX EXTENSION RING WARNING When using a 12V panel, this device will yield required light output only in the 15 or 15/75 candela setting. A0106-00 Mounting Reversible strobe module Should the back box be located near an obstruction such as a doorway, the strobe module is field-reversible (Fig. 4). Figure 6. Removal of strobes from mounting plates To remove units from mounting plates, insert Quick Click Removal Tool as shown to unlock snap. While pushing in Removal Tool to release the snap, pull back on the strobe. Hinge the strobe module, disengage the Locking Rib, and lift the strobe away from the mounting plate. To reverse the strobe module: first remove the strobe from the mounting plate (Fig. 6). Turn the module so that it is upside down from its original position, re-insert the module into the mounting plate (be sure to insert the Locking Tab into the slot), and press the module into the mounting plate. The strobe module will make a “click” when it has locked into place. Turn the entire assembly so that the word “FIRE” is right side up. The unit can now be mounted. SNAP LEVER Flush mount back box The speaker/strobe can be flush mounted on a 4″×4″× 21/8″ back box with extension ring with pre-threaded holes (Fig. 5) as follows: A.Select the appropriate pair of diagonally opposite mounting holes in the speaker grille that will be used to D900-29-00 LOCKING RIB SLOT 3 INSERT REMOVALTOOL LOCKING RIB A0100-00 I56-2564-000 Surface mount with BBS-SP2 back box skirt Figure 6: Surface mount with SP2-BBS back box skirt An optional back box skirt is available to provide a finished appearance. Mount the skirt to the back box using the mounting screws provided with the speaker/strobe as follows: A.Use the two 8-32 × 13/4″ pan head screws to attach the speaker to the back box. B.Plug the two holes that will not be used for attachment, using plugs provided. 4-INCH BACK BOX BBS-SP2 DRYWALL SCREWS (OPTIONAL) A0107-00 NOTE: Two drywall screws (provided) may be used to fasten the BBS-SP2 to the wall. NOTE: The back box or back box with extension ring combination must be 4″ × 4″ with pre-threaded holes and a minimum of 21/8″ deep if using a BBS-SP2. NOTE: To surface mount the SP2 series speaker/strobe, the minimum depth required in the back box/ extension ring combination, is 25/8″. Figure 7: Mounting to irregular surfaces DRYWALL SCREWS (OPTIONAL A0108-00 LOCKING RIB SLOT Please refer to insert for the Limitations of Fire Alarm Systems WARNING The Limitations of If either of the voltage select or power select shunts is not plugged into one of the appropriate option positions, the speaker will not sound and there will be no trouble indication at the panel. Always make sure that the individual speakers are tested after installation per CAN/ULC S536 regulations. Speaker/Strobes The signal strobe may not be seen. The electronic visual warning signal uses an extremely reliable xenon flash tube. It flashes at least once every second. The strobe must not be installed in direct sunlight or areas of high light intensity (over 60 foot candles) where the visual flash might be disregarded or not seen. The strobe may not be seen by the visually impaired. The speaker may not be heard. The loudness of the speaker meets (or exceeds) the current Underwriters Laboratories’ of Canada standards. However, the speaker may not attract the attention of a sound sleeper or one who has recently used drugs or has been drinking alcoholic beverages. The speaker may not be heard if it is placed on a different floor from the person in hazard or if placed too far away to be heard over the ambient noise. Traffic, air conditioners, machinery, or music appliances may prevent even alert persons from hearing the alarm. The speaker may not be heard by persons who are hearing impaired. The signal strobe may cause seizures. Individuals who have positive photic response to visual stimuli with seizures, such as persons with epilepsy, should avoid prolonged exposure to environments in which strobe signals, including this strobe, are activated. The signal strobe cannot operate from coded power supplies. Coded power supplies produce interrupted power. The strobe must have an uninterrupted source of power in order to operate correctly. System Sensor recommends that the horn and signal strobe always be used in combination so that the risks from any of the above limitations are minimized. Three-Year Limited Warranty Department, RA #__________, 6-6581 Kitimat Rd. Mississauga ON, L5N System Sensor warrants its enclosed speaker/strobe to be free from 3T5. Please include a note describing the malfunction and suspected defects in materials and workmanship under normal use and service for a cause. The Company shall not be obligated to repair or replace units period of three years from date of manufacture. System Sensor makes no which are found to be defective because of damage, unreasonable use, other express warranty for this speaker/strobe. No agent, representative, modifications, or alterations occurring after the date of manufacture. In dealer, or employee of the Company has the authority to increase or alter no case shall the Company be liable for any consequential or incidental the obligations or limitations of this Warranty. The Company’s obligation damages for breach of this or any other Warranty, expressed or implied of this Warranty shall be limited to the repair or replacement of any part whatsoever, even if the loss or damage is caused by the Company’s of the speaker/strobe which is found to be defective in materials or worknegligence or fault. Some states do not allow the exclusion or limitation of manship under normal use and service during the three year period comincidental or consequential damages, so the above limitation or exclusion mencing with the date of manufacture. After phoning System Sensor’s toll may not apply to you. This Warranty gives you specific legal rights, and free number 800-SENSOR2 (736-7672) for a Return Authorization numyou may also have other rights which vary from state to state. ber, send defective units postage prepaid to: System Sensor, Returns FCC Statement SpectrAlert Speaker/Strobes have been tested and found to comply with frequency energy and, if not installed and used in accordance with the the limits for a Class B digital device, pursuant to part 15 of the FCC instruction manual, may cause harmful interference to radio communicaRules. These limits are designed to provide reasonable protection against tions. operation of this equipment in a residential area is likely to cause harmful interference when the equipment is operated in a commercial harmful interference in which case the user will be required to correct the environment. This equipment generates, uses, and can radiate radio interference at his own expense. D900-29-00 4 I56-2564-000 ©System Sensor 2004