REINFORCING THE TREATMENT CHAIN REINFORCING THE TREATMENT CHAIN Radiation therapy has evolved considerably during the past few decades, with the introduction of increasingly conformal treatment techniques as well as capabilities for on-board volumetric imaging in the treatment VOLUMETRIC IMAGING TREATMENT PLANNING rooms. This has enabled a new level of accuracy in the delivered dose distributions with a corresponding improvement in clinical outcomes. Looking at the treatment chain as a whole there is however still room for improvement. While many links are now strong, others remain weak. Only when all the links have been strengthened, the complete chain will be stronger. It’s time to continue the work of reinforcing the treatment chain. Image quality issues due to respiratory motion Information loss in multimodal imaging Lack of dynamic information SETUP OF IMOBILIZATION DEVICES Placement and adjustment errors PATIENT IDENTIFICATION PATIENT SETUP & POSITIONING Identity mix-ups Posture errors TREATMENT DELIVERY Undetected intrafraction motion Undetected anatomical changes Risk of collision Insufficient protection of risk organs Couch shift inaccuracies Patient health uncertainty ^ ^ ^ Works in progress. Not for sale in the US. OVERVIEW The Catalyst™ system consists of a next generation optical surface scanning and re-projection hardware device coupled with a highly optimized application software designed for work-flow integration. SETUP AND POSITIONING OF EQUIPMENT The Catalyst™ projects the patient specific setup instructions directly onto the couch surface. It also confirms the identity, placement, and configuration of the immobili-zation Installation requires only one hardware unit in the treatment room. The unit is mounted to the ceiling at the foot end of the couch where it has an unobstructed view of the patient independently of any motion of the gantry or its on-board imagers. To ensure a flexible installation and virtually eliminate the risk of interference from other equipment, the scanner unit is connected to the Catalyst™ workstation in the control area using a fiber optic link. devices according to the patientspecific setup. PATIENT IDENTIFICATION Patient identity is automatically verified through detection of biometric features. Identity mismatch is clearly indicated by an alarm. SETUP AND POSITIONING Reassuring Radiation therapy is a complex process, where many pieces of equipment, in many cases from different vendors, need to work together during the different steps of the treatment chain. The Catalyst™ provides automatic and independent verification of many critical parameters that were previously only possible to check manually. The Catalyst™ thus reinforces the treatment chain. DESIGNED FOR WORKFLOW INTEGRATION BACKGROUND Radiation therapy has evolved considerably during the past few decades, with the introduction of increasingly conformal treatment techniques as well as capabilities for on-board volumetric imaging in the treatment rooms. This has enabled a new level of accuracy in the delivered dose distributions with a corresponding improvement in clinical outcomes. Looking at the treatment chain as a whole there is however still room for improvement. While many links are now strong, others remain weak. Only when all the links have been strengthened, the complete chain will be stronger. THE TREATMENT CHAIN Volumetric Imaging The radiation therapy process begins with volumetric imaging, and everything that follows is based on the accuracy and fidelity of the patient´s planning CT data-set. While treatment planning systems are designed to work with conventionally acquired planning CTs, they will never rise to their full potential in the case of image blurring due to respiratory motion. The main challenge, of course, is to be able to precisely delineate the target structures and risk organs, since this is a requirement for reaching the goal of maximizing the target dose while minimizing the side effects to healthy tissue. It’s time to continue the work of reinforcing the treatment chain. The Catalyst™ works with modern oncology CTs, providing the required respiratory signal for OF PATIENTS Information on posture and positioning errors is continuously projected directly onto the patient’s skin. The calculated couch shift can be sent to a compatible couch control system, enabling auto-setup. Intuitive Requiring minimal user interaction, the Catalyst™ acts as an always present decision support system where the required information is projected directly on the couch or patient. The system’s high performance provides immediate and real-time feedback, which means that the therapist can keep focusing on ensuring the best possible patient comfort and treatment outcome. Connected The Catalyst™ software is built from the ground up for a networked environment. Tight integration with other systems in the clinic ensures a smooth work-flow where data is transferred automatically via industry standard or vendor specific interfaces. When the patient is selected in the R&V system, the same patient is automatically selected in the Catalyst™, and computed shifts can in most cases also be applied automatically. The central patient database ensures that the correct settings are always available even in cases where the patient needs to be treated in a different room. 4DCT reconstruction as well as prospectively gated imaging. The patient´s respiratory characteristics are also recorded, which makes it possible to verify that the same breathing pattern is reproduced in the treatment room. In cases where multi-modality imaging is employed to obtain a more complete picture, having a Catalyst™ in each room provides a common reference frame for performing image fusion using the captured data sets. Treatment Planning Even with today’s advanced treatment techniques, treatment planning is still typically done only once, before the first treatment fraction. Anatomical changes and other dynamic information cannot therefore be taken into account, which limits the accuracy of treatment delivery. By incorporating information on the actual patient movement during the fractions already delivered, the treatment plan for the remaining fractions can be adapted to compensate for any deviations, such as patient relaxation after initial positioning. Stochastic deviations can be analyzed for determining whether the patient is properly immobilized and whether the set PTV margin is appropriate. Setup of Immobilization Devices Immobilization devices play an important role in achieving a reproducible patient setup. It is therefore very important that the correct devi- ces be placed at the correct index positions on the couch, and that any adjustments be done properly for each patient. This critical information on the exact placement and configuration of devices is however often documented only as textual setup instructions in the patient journal, with no independent means of verification. With the Catalyst™, the patient specific setup is recorded once at the first treatment fraction or even at the time of the planning CT. In the treatment room, the setup instructions are projected directly onto the treatment couch. Placement of each immobilization device is verified as are any adjustments required. Patient Identification With the steadily increasing demands on time efficiency in combination with more flexible treatment scheduling options, making sure that each patient receives treatment according to the correct prescription is more challenging than ever. The obvious solution is to introduce safety procedures where the patient identity is checked manually by the therapy staff at each treatment fraction. With a Catalyst™, patient identity is instead verified as an integral part of the setup procedure, ensuring patient safety with minimal overhead. Any identity mismatch will be clearly indicated by an alarm. INTRA-FRACTION MOTION DETECTION The patient is continuously monitored during the entire fraction. Any deviations outside the set tolerances will be signaled by an audible and visual alarm, or alternatively a beam hold signal can be triggered. CONTINOUS RECORDING OF PATIENT POSITION AND POSTURE In adaptive therapy, a CBCT system is typically used to capture anatomical changes at each treatment fraction. Here, the Catalyst™ will record patient motion during the actual treatment delivery to complete the picture. RESPIRATORY GATING The Catalyst™ enables 4DCT or gated imaging during planning CT acquisition. In the treatment room, the patient’s respiratory motion is monitored to ensure the same breathing pattern as the one recorded in the CT is present. Finally, gated treatments are supported where the actual beam delivery is constrained to a specific respiratory phase or breath-hold state. ^ ^ ^ Works in progress. Not for sale in the US. HEALTH MONITORING In cases where a patient’s health needs to be monitored during diagnostic imaging or treatment delivery, the Catalyst™ will provide a continuous indication of the detected vital signs. COLLISION AVOIDANCE Through continuous monitoring of the couch, gantry, and patient, the Catalyst™ detects when there is a risk of collision and will then issue an audible alarm. IMAGE FUSION In order to get the most information from diagnostic imaging, there is sometimes a need to combine the acquired images from multiple modalities. The Catalyst™ can, by recording the patient’s position at each imaging session, provide a common coordinate system to which the data sets can be co-registered. Patient setup and positioning. While IGRT systems are often used for final positioning, body tattoos and room lasers are typically still used for initial setup, meaning that only three points on the skin surface are used as the basis for setting up the whole patient. Correcting a setup error means that the patient position must be shifted manually, and then both sides of the patient checked again for laser/tattoo alignment. Also, it is typically not possible to detect posture errors or misalignment of patient extremities with a classic ”3 point set up”. With the Catalyst™, a complete body surface is captured continuously and compared to the previously recorded reference setup image in real time. Any deviations in posture are immediately indicated by a projection directly onto the patient’s skin, ensuring a fully interactive work flow. The required couch shift is also shown, providing instructions for moving the patient to the treatment position, even if setup is done at a lower couch height. Treatment Delivery During treatment delivery, it is important to continuously monitor the patient to make sure that no clinically significant movements occur. This is traditionally done using in-room video cameras connected to TV monitors in the control area. While large patient movements can thereby often be detected, this requires the full attention of the therapists. The Catalyst™ continuously monitors the patient during the entire fraction. Any movements outside of clinician set tolerances will trigger an alarm and optionally pause the beam until the patient is again within tolerance. Gantry, couch, and patient are also monitored continuously for possible collision risks. Additionally, the patient’s vital signs can also be monitored to make sure that the patient is at good health during treatment delivery. TECHNOLOGY Optical Triangulation Measurement in the Catalyst™ system is based on the principle of optical triangulation. A rapid and near-invisible sequence of patterns is projected onto the surface of the object to be measured. At the same time, images are captured by a camera, which is mounted at an angle from the projector. By analyzing the recorded image sequence, a high resolution 3D surface model can immediately be reconstructed. Thanks to the speed and stability of the system´s components and mechanics, a complete surface can be captured in fractions of a second, with an accuracy of a few tenths of a millimeter – measured at a distance of several meters away. Re-projection and Visual Guidance While near-invisible light is employed for measurements, the Catalyst™ is also capable of projecting a high-resolution multicolor light field onto the measured surface (so called reprojection). Measurement and re-projection can be done in parallel which enables a fully interactive feedback loop where misalignment and required corrections are clearly indicated and continuously updated. Marker Tracking Apart from being a high-performance surface scanning system, the Catalyst™ platform also features direct, real-time identification and tracking of markers. This is useful where some objects to be detected are very similar in shape but still need to be uniquely identified (this is likely to be the case with e.g. immobilization devices). It can also be a benefit in cases where an object´s color, surface pro- High-performance measurement and computation allows the patient motion to be tracked and applied to a deformable volumetric model in real-time. Information on any set-up errors as well as the required couch shift to bring the target (red sphere) to the treatment position (blue sphere) is continuously re-projected directly on the patient’s skin, thus forming a complete feedback loop. perties or shape makes it difficult to locate reliably based on surface registration only. Non-rigid Registration The highly optimized non-rigid surface registration algorithms in the Catalyst™ system enable the real-time and continuous tracking of any motion of the patient’s skin surface, without requiring the presence of any markers or tattoos. This allows any setup errors to be immediately detected and provides information on any movement during treatment delivery. patient positioning and intra-fraction motion detection, where there is an interest in acting on the target position as well as the detected motion on the skin surface. By aggregation of the data collected during each complete respiratory cycle, the clinically relevant timeweighted average target position is modeled. Deformable Models With knowledge of the surface movements, a volumetric deformable model is used to predict the influence on the actual target position. This is useful for many applications such as AN INTERACTIVE SOLUTION WITH ADAPTATION TO PATIENT ANATOMY ^ ^ ^ Works in progress. Not for sale in the US. SP-002-110429-001-01 C-RAD AB Bredgränd 18 SE-753 20 Uppsala Sweden www.c-rad.se