PRODUCT INFORMATION AND INSTALLATIONS OF
KABA MINI DELTA
PAGE
CONTENT
2
PRODUCT DESCRIPTION
3
CHOICES OF CENTRAL UNIT
4-5
PERFORMANCE OF DELIVERY, DIFFERENT MODELS.
6
MEASUREMENTS FOR KABA MINI DELTA
7
INSTALLATION OF KABA MINI DELTA
8-11
CENTRAL UNIT DC:1
Measurements / Technical specification
Product description
Connections, terminal blocks
Installation
12
CENTRAL UNIT DC:3
Measurements / Technical specification
Product description
Connections, terminal blocks
Installation
13-14
RELAY OUTPUTS DC-3
15
MAINTENANCE OF KABA MINI DELTA
16
TROUBLE-SHOOTING
R
R
Kaba AB reserve the rights to change the product without futher information
installationsanvisning Kaba mini delta /031218/HN/utgåva 3
1
PRODUCT DESCRIPTION
Kaba mini delta consists of three basic units: motorized strikingplate , central unit and forend.
Strikingplate. Consists of motor unit and forend. The forend is available in different kinds that suits the
most common locks on the market. The strikingplate usualy orders complete i.e. with forend.
- All details in the strikingplate is manufactured in stainless steel.
- The strikingplate has a hardened locking mechanism driven by an electrical motor.
- Locking and opening time approx. 0,3 s.
- A sensor for the bolt is placed in the strikingplates bolt opening, it senses the bolt of the lock and give
together with the door sensor, a pulse to the deltastrike to lock.
- A door sensor (magnet contact) is installed separately and connected to the central unit.
The door sensor give information of the door status (opened or closed) to the system. The strikingplate can
only lock, when the door is closed and the bolt is in place.
Central unit. Is available in two different models. The most simple model is named DC-1 and can be used in
installations that not include intruder detection system and RUS-regulation etc. The more advanced variant
is named DC-3 and offer considerable more in- and outputs and is better suited for installation that
comprise of demands from the insurance companies and where the strikingplate is a part of the intruder
detection system. Connect power, door opener pushbutton, reader, door sensor, door indication etc. to the
control unit. You will also find system adjustments, relays and the installation button.
Make sure that the following material is included in the package:
- Motorstrikingplate with forend. (forend/plate can also be deliverd separate)
- Central unit.
- Installation cable approx. 5 m.
- Fastening material for door that opens outwards: washer, nut, M6 screw
for door that opens inwards: washer, nut, M5 screw with brass ball, plastic plug
- Protection rivet in standard shape.
- Door sensor (magnet contact).
Extra accessories:
- Door indication. Gives optical and acoustic signal about the lock and door status. Functions can be
chosen in the function settings of the central unit. Can only be used together with central unit DC-3.
- Spring return handle. (for ASSA lockcases) Fitted on the lock as a usual knob, but contains a spring,
controlling that the lock bolt is lock out. By installing a spring return handle you obtain a function
identical with a usual latch lock, i.e. a comfortable and simple exit with automatic locking.
- Turning limiter. (for ASSA lockcases) Fitted as a cylinder extension behind the lock cylinder. The
turning limiter makes it impossible to withdraw the key unless the lock is locked. If the door shall be
unlocked, this must be carried out electrically.
- Protection cover. There are some different models of protection covers as accessory.
installationsanvisning Kaba mini delta /031218/HN/utgåva 3
2
CHOICES OF CENTRAL UNIT
Kaba mini delta
Kaba Delta motor strikingplate offers a solid locking device with high flexibility. Different door- and
lockfunction can be obtained together with the chosen lock housing (narrow profile lock, emergency
evacuate lock, hook latch bolt etc.). Kaba mini delta fit the most of the existing lock housing on the
market. It makes it possible to use the same motor locking (Kaba mini delta) to create a solid lock
installation that forfill the demands from the insurance companies. This makes it easy for service and
maintenance in the future and it make the planning easier.
This document describe the Kaba mini delta in a so called ”stand-alone”-installation, which means that the
Kaba Delta motor strikingplate is used for locking together with other manufacturers products. To do such
installation you must have one central unit for each Kaba Delta. This unit function is a interface to the
surrounding. You have two different central units to choose from, the more simpler unit is named DC-1 and
can be used in installations that not include intruder detection system and RUS-regulation etc. The more
advanced variant is named DC-3 and offer considerable more in- and outputs and is better suited for
installation that comprise of demands from the insurance companies and where the strikingplate is a part
of the intruder detection system. Both variants is presented i this product information.
Kaba mini delta with central unit DC-1
Kaba mini delta with central unit DC-3
R
R
installationsanvisning Kaba mini delta /031218/HN/utgåva 3
3
Performance of delivery
Kaba mini delta is normally delivered complete with forend. There are several models of forends fitting
different lock cases and doors.
Different models
Kaba mini delta can be received in many different models that is adapted to fit the different types of
lock housing on the markets.
Down below is the different models presented who can be received as standard.
The performance of the strikingplate can be cleared from the designation and will be
interpret as followed:
R
total length
The first letter i the designation indicate what type of lock that fits the
strikingplate.
R = Dead bolt lock (with or without latch).
H = Hook bolt (with or without latch).
EV = Assa Evolution lock case
Indicate the total length of the strikingplate in mm.
Indicate the lip width of the strikingplate in mm.
R
H 245 / 13 / V
Indicate if the strikingplate is
intended for a left (V) or right hang
(H) door. If the information (V or H)
is missing, are the strikingplate
turn able and can be used for both
left and right hanged doors.
lip width
Kaba mini delta for Dead bolt lock
Total length 245 mm.
R245/13, R245/16 ,R245/15/15 ,R245/15/26
Total length 410 mm.
R410/13/V, R410/13/H.
Continues on next page.
installationsanvisning Kaba mini delta /031218/HN/utgåva 3
4
Kaba mini delta for Hook bolt locks
Total length 245 mm.
EV245/13/V , EV245/13/H.
EV245-16-15V , EV245-16-15H , EV245-15-26V , EV245-15-26H
Total length 245 mm.
H245/13/V, H245/13/H,H245/16/V, H245/16/H.
Total length 410 mm.
H410/13/V, H410/13/H
NB!
Installations together with Assa 13787. The strikingplate with designation V
(for left handed door) and H (for right hanged door) must be switched.
Example. H245/13/V shall be used for a right hanged door and s H245/13/H
shall be used for a left hanged door.
- Lockcases there the hookbolt come from above and lock down the strikingplate H410-13H/V also must be switched.
installationsanvisning Kaba mini delta /031218/HN/utgåva 3
5
Kaba mini delta with screw connector
39
Measurements for Kaba mini delta
35,5
R
104,5
20
Installationhole in the frame has to be
200mm center from the bolthole in the delta.
36
245
160
3
7
R
Kaba Mini Delta16med skruvplint
104,5
50
42
22,5
7
20
From 2007-10-22 så levereras alla minidelta i detta utförande
Denna 7-polig skruvplint är jackbar för enklare installation.
CAT5 kabel levereras med i standardförpackningen.
Kaba mini delta connector
Klipp bort RJ45 i ena änden och skala upp kabeln.
Cut the RJ45 contact in one end and peel the 8 cables.
Anslut kablarna enligt färgschemat nedan.
Connect the cables into the connector according to this colours.
•
•
•
•
•
•
•
1 -
2 -
3 -
4 -
5 -
6 -
7 -
1-
Orange/vit
Orange/white
2Orange
Orange
Green/white
3Grön/vit
Blue/white
4Blå/vit
Green
Brown/white
5Grön
Blue and Brown (2 cables = ground)
6Brun/vit
7- the colours
Blå och
Brun
(2 kablar=
jord)
Important that
be right
connected
, otherwise
the functions can be incorrect.
Kontrollera att färgerna på kablarna är korrekt inkopplade innan
anläggningen spänningsätts.
KI 40446/art.nr. 285625/ 071120/LL/utgåva 9
6
Installation of Kaba mini delta
Installationen step by step.
R
Regardless of central unit, must the Kaba delta be installed according to this description.
Recommendation: If possible use a 24 V DC power supply, it gives you the best performance
concerning the opening and closing speed for the strikingplate (approx. 0,3 s). Lower
power supply give you a slower strikingplate which can be annoying for the user.
1. Make sure that you use the right model, the forend of the strikingplate have to fit with
the lockcase and the door.
2. Install the Kaba mini delta in the frame, the bolt for the lock have to be centred in the
strikingplate. To receive maximum strength in the lock unit, the screw that´s runs through
the strikingplate have to be installed.
3. Install the central unit that you want to use, close to the door. The delivered installation
cable is approx. 5 m long. If the distance between the strikingplate and the central unit is
longer must the loss of power be taken into consideration.
R
4. To get the best result, connect attached contact gear on the installation cable at the
strikingplate.
5. Connect the door sensor to the central unit. The sensor have to be closed when the
door is closed. Use the door sensor that is included in the delivered pack. Install the end
with the cord on a suitable place on the frame and connect the cables to the central unit.
Install the magnet part in the door at the same height as the part in the frame.
Drill a 19 mm hole for respective part. The detection ability for the magnet contact is approx. 50
mm for un-magnetically materials as aluminium, stainless steel or wood and approx. 10 mm for
magnetically material (steel). If the distance between the door and the frame is to large for the detection is
it necessary to use another type of sensor.
6. Set the required functions, use the jumpers and dip-switches (DC-3) in the central unit.
7. Switch on power to the installation.
8. Press the install-button in the central unit. Wait a few seconds for the information to be downloaded to
the strikingplate.
9. Make sure that the bolt is lock out and check the functions for the sensors (opener push button and
door sensor). The functions for the sensors is easy to check with help from the LED´s on the central unit
DC1.
10. If the dooredge doesnt cover the hollow for the bolt in the frame, can you install a protection cover on the door.
This avoid the possibility to be pitched by the strikingplate and make it hard put anything inside the
strikingplate that can cause unnecessary interruption.
11. Test the installation.
Moore detailed information about the electrical installation can you find for the central units (DC-1
and DC-3).
installationsanvisning Kaba mini delta /031218/HN/utgåva 3
7
Central unit DC-1
Central unit DC-1
Is used for simple installations and for installations where the unit is
communicating on the network (RS-485). This unit is equipped with the basic
functions for simple installations. For installations that need more function you
have to use the central unit DC-3.
Technical data
Supply voltage:
Supply current
excl strikingplate:
incl strikingplate:
Temperature:
Outputs
Output voltage:
Alarm:
Supply current relay:
Inputs
Opening signal:
Door input:
15-30V DC or 12-18V AC
at rest 20 mA at 12V
at rest 115 mA at 12V, 65 mA at 24V.
running 250 mA.
motorstart (50 mS) 1.400 mA at 12V
1.300 mA at 24V.
-5°C - +60°C
On output, same as supply voltage DC max 300 mA
Voltage output, breaks at tamper alarm
20 mA with activated relay
Data relay contacts
Function:
single pole variation
Breaking ability:
500 mA 50 V
Contact resistance:< 50 mOhm
Life cycle assessment: >50 milj. operations
1 opto-isolated input. 10-30V AC/DC
1 opto-isolated input. 10-30V AC/DC
Communication
RS 485.
Cable: Two pare in Cat 5. (Installations cable 4 x 2).
32,5
31,5
Measurements
98,85
Com 1
Bolt
Input
Com 2
Door
Power
120
R
DC-1
installationsanvisning Kaba mini delta /031218/HN/utgåva 3
8
Central unit DC-1
Description
DC-1 have one relay output, which can be programmed in two different
ways. The relay changes on locked as default, but if you move the
jumper on Lock indication to Door automatics, which means that the
relay change state within 5 s when Kaba delta is opened and is suited
to activate and open the door automatic.
DC-1 have a input for separate installed door sensor (magnet contact),
at delivery is the jumper set on Door. To achieve the maximum security
should the magnet contact in the delivered pack always be installed
and the jumper place on Door be removed.
DC-1 have a voltage output for sabotage alarm (tamper).
At delivery is the jumper placed at Spring return handle which mean
that the Kaba delta always opens on key or spring return handle. If the
lock is installed with cylinder from both sides, so-called dual cylinders,
must the jumper be removed.
Address for Group and Device is only used for installations there the
central unit is connected to a network on the attended terminal
(RS485).
For power supply is 12-18V AC or 15-30 V DC recommended, lower
voltage means slower opening and closing of the strikingplate, Lowest
accepted voltage is 12V DC. If the centralunit supply is over 30volt the unit be damage.
DC-1 is equipped with six LED:s as shows as follow:
Com 1
Com 2
Bolt
Door
Input
Power
= Communicating with Kaba delta = LED blinking.
= Not used.
= The bolt for the lock is indicated by the Kaba delta = LED on.
= Door status opened/closed. LED on = closed.
= Open signal exists = LED on.
= DC-1 power on = LED on.
Kaba mini delta is connected to DC-1 via contact gear RJ45. If possible use the delivered connection cable
(approx. 5 m).
Installation button (Inst) shall always be used in a new installation or if the settings in the DC-1 has
changes. If you push the Inst. button the central unit sends the actual setting and if possible the opening
codes to the Kaba mini delta.
Jumpers
RS 485
Tamper
Group
Device
Com1
Com2
Bolt
Door
Input
Power
Dörr
Larm
12Volt ut
Öppna
12-24Volt AC/DC
Chassiejord
NO
NC
C
Relä
Aut
Låst
RJ45
Inst.
Fjäder
installationsanvisning Kaba mini delta /031218/HN/utgåva 3
Aut Jumper in place give 5 s pulse on the relay when
the strikingplate is open. Suitable for door automatic
use.
Locked Jumper in place gives a continuous closing on
the relay when the door is locked.
Door. Jumper in place give by pass the door sensor
(magnet contact), this means that the door status will
be ignored at spring return handle.
Spring return handle. Jumper in place give spring
return handle which means that the Kaba delta opening
when the bolt and door disappear from closed
strikingplate. (If jumper for door is in place occurs the
opening when the bolt disappear from non opened
strikingplate.)
9
Central unit DC-1
Connections.
10-pole terminal.
1.
12-18V AC or 15-30V DC
2.
3.
Ground
4.
+12-24V DC out 100mA
5.
–12-24V DC out
6.
Open input (10-30V AC/DC. approx. 20 mA)
7.
8.
Door input. Potential-free closure.
9.
10.
Alarm. Continuous voltage (= direct voltage) is disrupted if
the door sensor or bolt disappear from the locked
strikingplate under the condition that neither of the jumper
”door” or ”string return handle” is in place. It even breaks
when the tamper contact is activated (cover is removed).
}
}
}
RS 485
Tamper
Group
Device
Com1
Com2
Bolt
Door
Input
Power
Dörr
Larm
12Volt ut
Öppna
12-24Volt AC/DC
Chassiejord
NO
NC
C
3-pole
1.
2.
3.
Relä
terminal for relay.
NO
NC
C
Aut
Låst
RJ45
Inst.
Fjäder
The relay can be change with a jumper to be
activated at locked alternative door
automatic.
Locked: The relay is activated when the door
input is closed (on), the bolt is in place (on)
and the Kaba delta is looked.
Door automatic: The relay is activated under
5 s when then Kaba delta is opened.
Installation button.
Connect the central unit with the Kaba delta. It must be used
for verify changes on the dipswitches and jumpers on the
central unit.
N.A! It is important to connect the central unit to ground (terminal 3). If it is connected to ground is the
installation protected against transients (type statically electricity). If its not connected to ground can it
mean disruption in the function or total failure of the unit.
installationsanvisning Kaba mini delta /031218/HN/utgåva 3
10
Central unit DC-1
Connection
Connection of power supply
Power supply is connected on terminal 1 and 2.
N.A. DC-1 has inbuilt overload protector on both
inputs and outputs. Any overload can mean that DC1 stop functioning complete or partly. It automatically
restore after max 30 s after the fault is corrected.
Connection of ground
Ground is connected on terminal 3. Should be
connected to protect the unit to avoid unnecessary
disruption from overload in the cables.
Connection of door sensor (magnet contact)
Door sensor is connected on terminal 8 and 9.
If possible use delivered door sensor (NO = closed
when the door is closed)
Connect as the picture is showing with the magnet
contact on terminal 8 and 9.
Connection of open signal
Open signal is connected on terminal 6 and 7.
Open signal with only closing (push button).
Connect as the picture is showing with the jumper
on 5 and 6 and potential-free closing (push button)
on 4 and 7. If several strikingplates shall be
monitored must the open signal with voltage be used
(see below).
Open signal with voltage.
10-30V AC/DC can be connected directly on terminal
6 and 7. The connection is independent of polarities.
N.A! f several strikingplates shall be monitored by
the same open signal e.g. from timeclock, do you
have to use the same power supply.
Connection of alarm
The output has a continuous 12-24V DC (depending on
supply voltage) this is interrupted if a alarm occurs. If the
door sensor is broken or the bolt is removed from a
looked strikingplate is this considered as a alarm, under
the condition that the jumper for ”door” and ”spring return
handle” is in place, and the tamper contact in DC-1 is
activated (cover is opened). If the alarm is desired as
potential-free closing have you to connect a mini relay
(Kaba 285555 or 285557) to the input.
installationsanvisning Kaba mini delta /031218/HN/utgåva 3
1 2 3 4 5 6 7 8 9 10
supply voltage
12-18V AC or 15-30V DC
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
contact at open
door
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
open signal
10-30V AC/DC
1 2 3 4 5 6 7 8 9 10
-
+
15-24V DC, depending
on supply voltage
11
Central unit DC-3
Central unit DC-3
Is used in installations when high security is wanted. Central unit DC-3 have many inputs and outputs,
that make the product flexible for many functions. Here you find controlling of door open automatics with
inputs for elbow contacts at the inside and outside. Central unit DC-3 have controlling of a sophisticated
burglar alarm system and can be used as a sensor for the burglar alarm system. It is possible to connect
door indication, acoustic and optical signals, as the insurance companies demands for certain
installations.
In addition to the motorized locking is the Control unit DC-3 equipped with a local surveillance function
with means that several points in the building can be surveillanced when the Kaba delta is locked.
In that way can the Kaba delta MS-3 together with the control unit DC-3 offer a simple burglar alarm and
most of all via a door indication panel (option) read out if the building is locked when the Kaba mini delta is
locking.
Connection 40-pol terminal.
}
installationsanvisning Kaba mini delta /031218/HN/utgåva 3
}
}
}
}
}
}
}
}
}
}
}
}
}
}
}
}
}
}
1. Relay 1 NO
2. Relay 1 NC
3. Relay 1 C
4. Relay 2 NO
5. Relay 2 NC
6. Relay 2 C
7. Relay 3 NO
8. Relay 3 NC
9. Relay 3 C
10. Tamper
Output tamper alarm
11. Tamper
12. Door sensor
Input door sensor
13. Door sensor
14. Alarm loop
Input extern slinga
15. Alarm loop
16. Blocking
Effect open input
17. Blocking
18. Elbow contact common
19. Elbow contact inside
20. Elbow contact outside
21. Door indication Open = green LED
22. Door indication Locked = red LED
23. Door indication Acoustic signal
24. +12V for ex. door indication panel
25. -12V for ex. open signal
26. Open input A
10-30V AC/DC
27. Open input A
28. Open input B
10-30V AC/DC
29. Open input B
30. Delta 1
Alt. connection.
31. Delta 2
Normalally use
32. Delta 3
RJ 45 contact for
33. Delta 4
connecting of the
34. Delta 5
Kaba mini delta.
35. Delta 6
36. Delta 7
37. Delta 8
38. Supply voltage 12-18V AC or
39. Supply voltage 15-30V DC
40. Ground. Connect to earth ground.
12
Relay outputs
Central unit DC-3
Relay outputs.
DC-3 has three configurable relays who is individual replaceable. For wished function for
respective relay you set a jumper. Each relay is equipped with a LED which indicates
when the relay is activated.
:::::::::::::
:::::::::::::
:::::::::::::
relay 1
relay 2
relay 3
Unlocked too long
Alarm unlocked too long
Door open to long
Alarm door open to long
Burglar alarm
Door automatic
Door status
Bolt status
Delta open
Delta locked
Day lock
Access allowed
System monitored
These output signals can be chosen:
position 1
:::::::::::::
position 2
:::::::::::::
position 3
:::::::::::::
position 4
:::::::::::::
System monitored. The relay change state if the central unit lose contact with
the strikingplate.
Access allowed. The relay change state when the Kaba delta gets a
allowed open signal and it will return when Kaba delta is locked again.
Day lock. The relay change state when the open signal is received on
open input B. It remains choppy under the time that the Kaba delta is
open, which as been set for the Kaba delta. Suitable for day lock
(electric strike).
Locked. The relay change state when the strikingplate is closed, door
and bolt is in place.
position 5
:::::::::::::
Strikingplate open. The relay change state when the strikingplate
is opened.
position 6
:::::::::::::
Bolt status. Bolt is disappearing from closed strikingplate.
Continuous on next page.
installationsanvisning Kaba mini delta /031218/HN/utgåva 3
13
Relay outputs
:::::::::::::
:::::::::::::
:::::::::::::
Central unit DC-3
relay 1
relay 2
relay 3
Unlocked too long
Alarm unlocked too long
Door open to long
Alarm door open to long
Burglar alarm
Door automatic
Door status
Bolt status
Delta open
Delta locked
Day lock
Access allowed
System monitored
position 7
:::::::::::::
Door status. The relay change state when the door is closed.
position 8
:::::::::::::
position 9
:::::::::::::
position 10
:::::::::::::
position 11
:::::::::::::
position 12
:::::::::::::
position 13
:::::::::::::
Open pulse to door automatic. The relay change state under 5 s. when
the strikingplate reaches opened.
Burglar alarm. The relay change state when the door or the bolt is
disappearing from a locked Kaba delta.
”Alarm” after "door open too long". The relay actives immediately after
the time for "door open to long" has run out. The relay remains
activated until the door is closed.
"Door open too long". The relay change state when the door have been
open to long. The time before the relay should change state and how
long it should be activated is configured on the switch ”pre-alarm door”.
”Alarm” after "door unlocked too long". The relay actives after the time
for "door unlocked to long" has been active or immediately in case the
door is broken up. Includes ”alarm” that is on the input of a extern
alarm circuit.
"Door unlocked too long". The relay change state when the Kaba delta
has been unlocked to long. The time before the relay should change
state and how long it should be activated is configured on the switch
”pre-alarm unlocked”. Includes ”alarm” that is on the input of a extern
alarm circuit.
installationsanvisning Kaba mini delta /031218/HN/utgåva 3
14
Maintenance
Kaba mini delta is designed to function in troublesome environment under a long time.
The design allows the strikingplate to be exposed to wear for way more than 50.000
locking cycles as is according to present locking standard. To obtain a interruption free
function shall the strikingplate be lubricate regular. The interval of service is depending on
the environment and the frequency of use. Lubricate and any cleaning must be done for at
least every 50.000 opening cycles, every six month or in need.
Lubricate: Use Kaba Cleaner which applies on motor axe and other moving parts (see
picture).
R
Emergency locking.
The locking mechanisim on the Kaba mini delta can in case of emergency be manoeuvred
with a screwdriver. This can be necessary if the installation is out of power or can´t be
manoeuvred of any reason. To lock the Kaba deltan, make it powerless and screw the
screw anti clockwise.
R
Locking with a screwdriver.
R
Apply the lubricate on the slid out- and
inside.
R
installationsanvisning Kaba mini delta /031218/HN/utgåva 3
15
Trouble-shooting
Problem at start-up.
Checking / Measures
- Com1-lamp in the control unit is off.
- No communication with the strikingplate.
Probable cause: The cable between the central unit and the
strikingplate is broken.
Check any cable joint and contacts.
When communication is establish will the Com1-lamp flash.
- Com1-lamp in the control unit is on
with fixed green light.
- Communication with the strikingplate has stopped.
Probable cause is that the equipment has been exposed to a
electric disturbance (example static electricity, thunder).
Make sure that the central unit is well protected and connected
to ground according to installation instructions.
Try to restart it by making the central unit powerless for a few
seconds. Observe that a electric disturbance can hurt the
electronics.
When communication is establish will the Com1-lamp flash.
- The strikingplate does not lock.
- Check that the bolt is in position and indicated in the central
unit (Bolt).
- Check that the magnet correctly installed and indicated in the
central unit (Door).
- The strikingplate does not open.
- Check that open signal is received in a correct way and
indicated in the central unit (Input).
- The strikingplate tries to lock but
turns and opens again. The attempt is
repeated once more.
- Check the physical assembly of the strikingplate. The
strikingplate tries to open but does not reach open. Can be
caused by a ”slide screw” tighten too much in the strikingplate,
a damaged forend of the strikingplate or other physical
obstracle for the locking mechanism.
- Can even be bad power supply. See below.
- Strikingplate open cycle is longer
then 0,3 s.
- Power supply is lower then 18V DC. The power supply for the
strikingplate effects the speed, recommended voltage is approx
24 V DC for best performance. The strikingplate function down
to 12 V DC, but the speed is much slower.
- Kaba deltan doesn´t open with string
bolt handle.
- Check the indication LED:s, Door and Bolt on the central unit,
that they is off when the door is open. If any of these is on
haven´t the condition for opening been received. Search fault on
these senors.
If the bolt sensor (Bolt) is off is there something wrong with the
strikingplate and with biggest probability must it be exchanged.
If the door sensor (Door) is off, adjust the door sensor (magnet
contact). If the sensor is broken and it can´t imminently be
changed, can it be bypassed temporary in the central unit DC1. See description DC-1, jumpers.
To high powersupply into the DC-1.
Could also be to high powersupply.
-Com1 lamp is not light up.
-The relay in DC-1 behave strange.
installationsanvisning Kaba mini delta /031218/HN/utgåva 3
16
Assembling of forend/strikingplate.
1. The deltastrike has to be in open position(A)
This position can be change by a screwdriver(B)
2. Place the bladespring (C) into the 2 rivets.
3. Place the metalslide (D) into the 2 rivets..
4. Choose forend. Put some pressure at the metalslide(D) when the forend is fit in position.
The forend must have some angle and then glide into position.
-Put the screws(stainless steel) in the forend , start with (G)1pcs M6x12 , then (F)4pcs
M2x4 , (E)2pcs M4x8. Dont use longer screws , this could damage the strike.
-Check that the strike is working.
-Close the strike (B) manually a little bit to check that it move easily.
If not , some part is not in correct position.
F
B
A
C
E
D
G
KI 40446/art.nr. 285625/ 071120/LL/utgåva 9
17
NOTICE!!!
Fitting and maintenance...
!
!
""
""
No drilling
clean holes
Not
!
!
or cutting dust! Finish cutting/drilling work and
from metallic residue before fitting the strikingplate.
waterproof!
No
paint!
No oil or grease! Only use lubricants approved by Kaba AB, e.g. Kaba Cleaner. For more
information call +46 16 161527.
installationsanvisning Kaba mini delta /031218/HN/utgåva 3