Gamma instabus Technical Product Information RL 513D23 Switching actuator (relay), 3 x 6A 5WG1 513-4DB23 · Switching actuator for independent switching of three lighting luminaire groups or other loads ● ● ● Siemens AG Building Technologies Division Control Products and Systems P. O. Box 10 09 53, D-93009 Regensburg one relay contact (6A, AC 230V) per output as switching element, screwless terminals for connection and through-wiring of untreated single-core, stranded or multi-core conductors, 0.5 ... 2.5mm², ● ● Betrieb der Elektronik über Busspannung, ● ● ● ● Funktion bei Konfiguration mit der ETS Einbaugerät zur Montage in einer getrennt zu bestellenden Automationsmodulbox AP 118 oder Raumautomationsbox AP 641 counting of operating hours with threshold monitoring of the operating hours, counting of load cycles with threshold monitoring of the load cycles, integrated 8-bit scene control and linking of each output into up to 8 scenes, RL 513D23 Update: http://www.siemens.com/gamma-td ã Siemens AG 2015 Subject to change without further notice April 2015 Types Order number Type Applications KNX PL-Link 5WG1 513-4DB23 RL 513D23 · Switching of lighting circuits or other loads · Installation in an AP 118 Control Module Box or an AP 641 Room Control Box Yes Purchased parts package ● Module for installation in AP 118 Control module box or in AP 641 Room control box Accessories Type Order number Description 5WG1 118-4AB01 Automationsmodulbox AP 118 5WG1 641-3AB01 Raumautomationsbox AP 641 Features The RL 513D23 Switching actuator (relay) with mounting frame is a KNX device with three switching outputs. The device is installed in an AP 118 Control Module Box or an AP 641 Room Control Box. The bus is connected via a bus terminal block. The actuator electronics are supplied via the bus voltage. Usage The RL 513D23 can switch resistive loads (e.g. electrical heaters, incandescent lamps, high voltage halogen lamps), inductive loads (e.g. motor, low voltage halogen lamps with intermediate conventional transformers), or capacitive loads (e.g. low voltage halogen lamps with intermediate electronic transformers). Functions (configuration with ETS) The actuator output may be configured independently to provide switching, manual override, forced control, logical gate, and status reporting. Furthermore, if required, time-limited switching instead of permanent switching on can be enabled for each channel via an optional "Night mode" object (e.g. for lighting while cleaning), if need be with a warning before switching off by multiple switching the output on and off (flashing). Amongst others, the application program includes optional a switching cycle and operating hours count with threshold monitoring for each output and an integrated 8-bit scene control, in which the output can be incorporated into up to 8 scenes. Each output of the actuator may be set to one of the following operating modes: - Normal operation - Timer operation 2 / 10 Update: http://www.siemens.com/gamma-td April 2015 RL 513D23 ã Siemens AG 2015 Subject to change without further notice Siemens AG Building Technologies Division Control Products and Systems P. O. Box 10 09 53, D-93009 Regensburg Behavior at bus voltage failure / recovery Because the device electronics are powered by bus voltage a mains power failure only leads to a functional failure of the actuator if the bus voltage fails due to a failure of the mains voltage. Each actuator output is individually configurable regarding which switching position it shall take on bus voltage failure (Off, On, or No change) and which switching position it shall take on bus voltage recovery (Value prior to bus voltage failure, On, Off, or No change). On bus voltage failure the current switching status value is saved for restoration on bus voltage recovery. On bus voltage recovery the configured actions are executed and, if applicable, new status values are reported. Building site function The building site function provided ex-factory enables switching the building site lighting on and off via bus wall switches and actuators, even if these devices have not yet been commissioned with ETS. Factory default state In the default factory state all channels (outputs) are set to the function “switching” for the building site function. Behavior on unloading the application program When the application program is unloaded with ETS the device does not function. Resetting the device to factory default settings A very long push of the programming button (> 20 s) effects a reset to factory settings. This is indicated by constant flashing for 8 seconds. All configuration settings are lost. The building site function is re-activated. Addressing mode A short push of learning button (< 2 s) enables the addressing mode. This is indicated by a continuously lit programming mode LED. A second push disables this mode. Note A long push of the learning button (> 5 s and <20 s ) enables the Connection Test for commissioning with Desigo. Any time this mode can be disabled by a short push of the learning button. Application programs The RL 513D23 Switching actuator (relay) needs the application program “07 B0 A1 Switch actuator 982D02.” The device is configured and commissioned with the ETS (Engineering Tool Software) version ETS3 v3.0f or later. Example of Operation binary output RL513D23 3 / 10 Siemens AG Building Technologies Division Control Products and Systems P. O. Box 10 09 53, D-93009 Regensburg RL 513D23 Update: http://www.siemens.com/gamma-td ã Siemens AG 2015 Subject to change without further notice April 2015 Location and Function of the Display and Operating Elements, Interfaces A1 LED for indicating normal operating mode (LED off) or addressing mode (LED on); returns to normal operating mode automatically after receiving the physical address A2 Learning button for switching between normal operating mode and addressing mode and for receiving the physical address A short push of learning button (< 2 s) enables the addressing mode. This is indicated by a continuously lit programming mode LED. A second push disables this mode. Note: A long push of the learning button (> 5 s and <20 s) enables the Connection Test for commissioning with Desigo. Any time this mode can be disabled by a short push of the learning button. Factory settings: A very long push of the learning button (> 20s) effects a reset to factory settings. This is indicated by constant flashing of the addressing LED for 8 seconds. A3 Bus connection pins of the module for connection of the bus terminal block for single core conductors with 0.6…0.8 mm Ø A4 Type label (with space for physical address of the actuator) A5 Distance plate A6 Terminal Channel A A7 Terminal Channel B A8 Terminal Channel C A9 Distance plate A10 Terminal L A11 Identification number of the device Product Documentation Additional information like operating and mounting instruction, application program description, product database, additional software, product image, CE declaration etc. is available here: http://www.siemens.com/gamma-td Installation Notes Safety · The device is intended for installation in an AP 118 Control Module Box or an AP 641 Room Control Box. DANGER · · · · The device must be mounted and commissioned by an authorized electrician. A safety disconnection of the device must be possible. The device must not be opened. For planning and construction of electric installations, the relevant guidelines, regulations and standards of the respective country are to be considered. · When looping through the L-conductor, take care that the maximum permissible terminal load current of 16A is not exceeded! 4 / 10 Update: http://www.siemens.com/gamma-td April 2015 RL 513D23 ã Siemens AG 2015 Subject to change without further notice Siemens AG Building Technologies Division Control Products and Systems P. O. Box 10 09 53, D-93009 Regensburg Mounting and Wiring Mounting RL module B2 RL module B3 Type label B4 Mounting location for RS / RL module in AP 118 Control Module Box or AP 641 Room Control Box B8 Learning button B9 LED for indicating - normal operating mode (LED off), - programming mode (LED on) B10 Bus connection pins of the module for connection of the associated bus terminal block of the internal bus wire B11 Insertion point for bus terminal block B12 Bus terminal block for single core conductors with 0,6 … 0,8 mm Æ B13 Hinge joint for mounting hinge of the RL module B14 Terminals Mounting of an RL module - Remove the lid of the AP 118 Control Module Box respectively of the AP 641 Room Control Box. - AP 641: Remove the SELV (Clas 2) cover - Insert the RL module (B2) into the hinge (B13) of the mounting location (B4). The terminals (B14) point away from the insertion point for the bus terminal (B11). The typle label (B3) is on top. - Swivel the RL module (B2) down until it audibly snapy into the mounting location (B4). - Insert the bus terminal (B12) of the mounting location (B4) onto the bus connection pins (B10) of the RL module (B2). - For assignment of the Phyiscal address press the learning button (B8) for a maximum of 2 seconds. The addressing mode is indicated when the LED is on (B9). It returns to normal operating mode (LED off) automatically after receiving the physical address. - AP 641: Mount the SELV (class 2) cover again. - Mount the lid again. Dismounting an RL module - Remove the lid of the AP 118 Control Module Box respectively of the AP 641 room control box. - AP 641: Remove the SELV (Class 2) cover. - Remove the wiring from the terminals (B14). - Remove the bus terminal (B12). - To remove the RL module (B2), insert a screw driver between the module and the mounting location on the bus terminal side and push it up to release it from the snap-in hooks. - Swivel the RL module (B2) up, pull it down out of the hinge (B13) and remove it from the mounting location (B4). - AP 641: Mount the SELV (class 2) cover again. - Mount the lid again. 5 / 10 Siemens AG Building Technologies Division Control Products and Systems Postfach 10 09 53, D-93009 Regensburg RL 513D23 ã Siemens AG 2015 Änderungen vorbehalten Update: http://www.siemens.de/gamma-td April 2015 Wiring Slipping off/on bus connection blocks The bus terminal block (C2) consists of two components (C2.1 and C2.2) with four terminal contacts each. Take care not to damage the two test sockets (C2.3) by accidentally connecting them to the bus cable or with the screw driver (e.g. when attempting to unplug the bus terminal block). Slipping off bus connection blocks - Carefully put the screw driver to the wire insertion slit of the bus terminal block’s grey component (C2.2) and - pull the bus terminal block (C2) from the module. Note: Don’t try to remove the bus connection block from the bottom side. There is a risk of shorting-out the device! Slipping on bus connection blocks - Slip the bus terminal block (C2) onto the guide slot of the module and - press the bus terminal block (C2) down to the stop. D1 D2 D2 Connecting bus cables - The bus terminal block (D2) can be used with single core conductors Ø 0.6 … 0.8 mm. - Remove approx. 5 mm of insulation from the conductor (D1) and plug it into the bus terminal block (D2) (red = +, grey = -) Disconnecting bus cables - Unplug the bus terminal block (D2) and remove the bus cable conductor (D2.4) while simultaneously wiggling it. Connecting/disconnecting mains and load circuit Connect wires - The load circuits are connected via screwless plug-in terminals (E1). - Remove approx. 9…10 mm of insulation from the wire (E 1.1) and plug it into the terminal (E1). - The terminals are designed for connection of two wires allowing to loop through the terminal block. Note: The maximum permissible terminal load current is 16A. Remove wires Press the terminal interlocking ot the terminal (F1) with a screwdriver and remove the wire (F2) from the terminal (F1). 6 / 10 Update: http://www.siemens.com/gamma-td April 2015 RL125/23 ã Siemens AG 2015 Subject to change without further notice Siemens AG Building Technologies Division Control Products and Systems P. O. Box 10 09 53, D-93009 Regensburg Technical data Power Supply Power Supply via the bus line KNX bus voltage DC 24V (DC 21…30V) via KNX/EIB bus line KNX bus current < 10 mA Thermal dissipation los Device: 0,15 W (=min. total thermal dissipation loss) per output: 0,022 * (Ieff)² [W] min. total thermal dissipation loss: 0,15 W(load: 0A) max. total thermal dissipation loss: 2,09 W (load: 2x 6A, 1x 4A) Outputs Number 3 outputs Switching output, potential-free relay contacts - rated voltage: AC 230V, 50/60 Hz - rated current: 6A (resistive load) - switching current at AC 230V: 0,01 … 6A resistive load switching current at DC 24V: 6A resistive load 4A inductive load (4R=7ms) - max. relay position changes per minute: 60 Switching characteristic Set in parameter list according to application program Switching capacity at AC 230V For incandescent lamp load max. 1000W For fluorescent lamp load (LL) - uncompensated LL, cosj = 0,5: max. 500W parallel compensated LL, cosj = 1 (at Cges <= 14mF): 2 x 58W oder 3 x 36W oder 6 x 18W - Duo-configuration, cosj = 1: max. 1000W - OSRAM ECG for 58W LL: max. 10 pieces - OSRAM ECG for 36W LL: max. 15 pieces - OSRAM EVG for 18W LL: max. 20 pieces Display elements 1 red LED for monitoring bus voltage and for displaying normal mode / addressing mode Control elements 1 learning button for switching between normal operating mode and addressing mode Connections Bus line bus connection pins for connection of the screwless bus terminal block (red-black), 0,6 … 0,8 mm Ø single-core, strip insulation 5mm Load circuit 7 / 10 Siemens AG Building Technologies Division Control Products and Systems P. O. Box 10 09 53, D-93009 Regensburg screwless terminals 0,5 … 2,5 mm2 single-core, stranded or multi-core, untreated, strip insulation 9 … 10 mm RL 513D23 Update: http://www.siemens.com/gamma-td ã Siemens AG 2015 Subject to change without further notice April 2015 Physical specifications Housing plastic Dimensions (L x W x D) 86,5 x 47,8 x 36,2 mm Weight approx. 62 g Fire load approx. 2 MJ Installation Mounting location for RS / RL module in AP 118 Control Module Box (5WG1 118-4AB01) or AP 641 Room Control Box (5WG1 641-3AB01) Environment and safety regulations Degree of pollution (according to IEC 60664-1) Overvoltage category (according to IEC 60664-1) 2 III Protection type (in accordance with EN 60529) IP 20 Electrical Safety Bus safety extra low voltage SELV DC 24V Device complies with EN 50428 Relay with µ- contact Electromagnetic compatibility complies with EN 50428 Environmental conditions Climatic conditons EN 50090-2-2 Ambient operating temperature -5…+45°C Storage temperature -25 … +70°C Relative humidity (not condensing) 5 % to 93% Reliability Failure rate 395 fit at 40 °C Markings KNX EIB CE mark Complies with the EMC regulations (residential and functional buildings), low voltage regulations, and RoHS Directive 8 / 10 Update: http://www.siemens.com/gamma-td April 2015 RL 513D23 ã Siemens AG 2015 Subject to change without further notice Siemens AG Building Technologies Division Control Products and Systems P. O. Box 10 09 53, D-93009 Regensburg Dimension Drawing Dimensions in mm Support General Notes · The operating instructions must be handed over to the client. A faulty device shall be returned with a Return Good Note for Service provided by the appropriate Siemens sales office. If you have further questions concerning the product please contact our technical support. ' +49 (911) 895-7222 7 +49 (911) 895-7223 * [email protected] www.siemens.de/automation/support-request 9 / 10 Siemens AG Building Technologies Division Control Products and Systems P. O. Box 10 09 53, D-93009 Regensburg RL 513D23 Update: http://www.siemens.com/gamma-td ã Siemens AG 2015 Subject to change without further notice April 2015 Published by Siemens AG Building Technologies Division Control Products and Systems P. O. Box 10 09 53, D-93009 Regensburg © 2015 Copyright Siemens AG Subject to change without further notice Update: http://www.siemens.com/gamma-td 10 / 10 April 2015