INTERFACE Analog
MACX Analog / MCR Analog
Order key MACX MCR-UI-UI-... (Standard configuration entered as example)
Input
Order No.
2811459
Output
/
IN03
IN40
IN24
IN41
IN25
IN43
IN44
IN26
IN27
IN28
IN66
IN29
IN50
IN30
IN52
IN05
IN03
IN67
IN32
IN39
IN68
IN69
2811459 =
...-UI-UI-UP
2811585 =
...-UI-UI-UP-SP
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
0...50 mV
0...60 mV
0...75 mV
0...100 mV
0...120 mV
0...150 mV
0...200 mV
0...300 mV
0...500 mV
0...1000 mV
0...1.0 V
0...1.5 V
0...2.0 V
0...3.0 V
0...5 V
0...10 V
0...15 V
0...20 V
0...30 V
0...50 V
0...100 V
IN53
IN13
IN54
IN14
IN56
IN57
IN15
IN16
IN17
IN78
IN18
IN63
IN19
IN65
IN21
IN22
IN79
IN23
IN80
IN81
IN82
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
Limit frequency
/
-50...+50 mV
-60...+60 mV
-75..+75 mV
-100..+100 mV
-120...+120 mV
-150...+150 mV
-200...+200 mV
-300...+300 mV
-500...+500 mV
-1000...+1000 mV
-1.0...+1.0 V
-1.5...+1.5 V
-2.0...+2.0 V
-3.0...+3.0 V
-5...+5 V
-10...+10 V
-15...+15 V
-20...+20 V
-30...+30 V
-50...+50 V
-100...+100 V
IN06 = 1...5 V
IN04 = 2...10 V
IN70
IN71
IN72
IN73
IN36
IN37
IN74
IN01
IN75
IN76
IN77
=
=
=
=
=
=
=
=
=
=
=
0...1.0 mA
0...1.5 mA
0...2.0 mA
0...3.0 mA
0...5 mA
0...10 mA
0...15 mA
0...20 mA
0...30 mA
0...50 mA
0...100 mA
IN83
IN84
IN85
IN86
IN33
IN34
IN87
IN35
IN88
IN89
IN90
=
=
=
=
=
=
=
=
=
=
=
-1.0...+1.0 mA
-1.5...+1.5 mA
-2.0...+2.0 mA
-3.0...+3.0 mA
-5...+5 mA
-10...+10 mA
-15...+15 mA
-20...+20 mA
-30...+30 mA
-50...+50 mA
-100...+100 mA
OUT01
OUT19 = 0...2.5 V
OUT05 = 0...5 V
OUT03 = 0...10 V
OUT15 = 0...5 mA
OUT16 = 0...10 mA
OUT01 = 0...20 mA
OUT20 = -2.5...+2.5 V
OUT13 = -5...+5 V
OUT14 = -10...+10 V
OUT21 = -5...+5 mA
OUT22 = -10...+10 mA
OUT23 = -20...+20 mA
OUT24 = 0.5...+2.5 V
OUT06 = 1...5 V
OUT04 = 2...10 V
OUT25 = 1...5 mA
OUT26 = 2...10 mA
OUT02 = 4...20 mA
OUT27 = 2.5...0 V
OUT11 = 5...0 V
OUT09 = 10...0 V
OUT28 = 5...0 mA
OUT29 = 10...0 mA
OUT07 = 20...0 mA
/
30
30 = 30 Hz
10K = 10 kHz
Factory calibration
certificate
/
NONE
= Without certificate
= With factory
calibration
certificate (fee)
YESPLUS = Factory
calibration
certificate with
5 measuring
points (fee)
NONE
YES
IN91 = 1...5 mA
IN92 = 2...10 mA
IN02 = 4...20 mA
Application example: Level measurement and active analog input card
MACX MCR-UI-UI-UP
IN
Level sensor
4.2
0...20mA
24V
4.1
5.2
5.1
OUT
±50mV... ±1000mV
±1mA... ±5mA
–
active
±10mA... ±100mA
3.2
+
3.1
GND
2.2
passive
±1V... ±100V
2.1
Power
24V ...230V AC/DC
1.2
≃
1.1
Control system
Power
24V ...230V AC/DC
Application example: Shunt measurement and Inline terminal with analog input channels within an Inline station
MACX MCR-UI-UI-UP
M
IN
4.2
Shunt
resistor
mV
4.1
5.1
–
±10mA... ±100mA
–
active
3.2
D
+
3.1
AI2
5.2
+
OUT
±50mV... ±1000mV
±1mA... ±5mA
GND
±1V... ±100V
2.2
passive
1
2.1
Power
24V ...230V AC/DC
2
1
1
2
2
3
3
4
4
1.2
≃
1.1
Battery
Power
24V ...230V AC/DC
IB IL AI 2/SF
(Information about automation solutions from Phoenix Contact is given in the AUTOMATION catalog or under www.phoenixcontact.com)
Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108
[email protected] - 800-843-9859 - www.powermation.com
PHOENIX CONTACT
359