318 PHOENIX CONTACT Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com INTERFACE Analog Modular converters for MCR technology The modular MCR converters for MCR technology avoid the distortion of analog signals caused by external disturbance variables. With accurate conversion, isolation, filtering or adaptation of analog signals, they provide safe and increased transmission quality, and thus the quality of closed-loop control circuits. This is reflected in the following product segments: MINI Analog The modular, 6 mm wide system offers state-of-the-art technology for the most demanding requirements throughout the signal conversion range. MACX Analog / MCR Analog Multifunctional devices with highprecision transmission performance: – Configurable via DIP switch or software – Universally applicable and hence reduced storage costs – High level of availability – Digital displays for displaying analog standard signals, frequencies, pulses and times – Setpoint adjuster for the specification of analog current or voltage values, with a manual and automatic ramp function PACT Analog Space-saving current transformer range: – Depth of only 30 mm is uniformly used for all transformer sizes – Flexible installation position is possible, e.g. horizontal for branch exits – Up to 4000 A AC – 3000 versions – Also available in a calibration-capable and calibrated version Program overview Product overview 320 Basics 322 MINI Analog Isolation Temperature Conversion Control Accessories 328 330 340 343 345 347 MACX Analog / MCR Analog Isolation Temperature Conversion Control Power Configuration software 356 358 370 378 380 390 389 Digital displays Analog standard signals Frequencies, pulses, times Setpoint adjuster 383 385 386 PACT Analog Current transformer (cannot be calibrated) Current transformer (can be calibrated) Accessories 400 403 413 419 Function Line (...-FL-...) The multi-functional modules can be used universally; they increase the system availability and reduce storage costs. Standard Line (...-SL-...) The compact, space-saving and low-cost modules are particularly suitable for serial applications. Install, connect, finished! Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com PHOENIX CONTACT 319 INTERFACE Analog Product overview MINI Analog Product type Product details Isolation 3-way isolation amplifier 4-way signal duplicator 3-way repeater power supply 2-way passive isolator Page - Configurable - Fixed signal combinations - Configurable - Power supplied to input loops MINI MCR-SL-U...-...-UI MINI MCR-SL-SHUNT-UI MINI-MCR-SL-...-... MINI-MCR-SL-UI-2I MINI-MCR-SL-RPS... MINI-MCR-SL-...CP-I-I 330 332 335 336 337 338 - Power supplied to output loops Temperature Temperature transducers Page Universal, active Universal, passive RTD (e.g. Pt 100), active RTD (e.g. Pt 100), passive MINI-MCR-SL-PT100-UI... MINI-MCR-SL-PT100-LP 339 341 Thermocouples, active MINI-MCR-SL-TC-UI 342 Conversion Page Frequency transducers Potiposition transducers MINI-MCR-SL-UI-F MINI-MCR-SL-R-UI Control Threshold value switches Isolating switching amplifiers Setpoint adjusters Digital display 343 344 Page Temperature signals Analog standard signals MINI-MCR-SL-UI-REL 346 NAMUR sensors Current, voltage Setpoint potentiometer Constant voltage source Analog standard signals MINI-MCR-SL-NAM-2RNO 345 Frequencies, pulses, times Power Current transducers Universal, AC/DC currents Alternating current, AC, active Alternating current, AC, passive Voltage transducers Current transformers (cannot be calibrated) Current transformers (can be calibrated) Current protectors DC voltage AC voltage Bus-bar transformers Plug-in transformers Winding transformers Bus-bar transformers Plug-in transformers Accessories Configuration DIN rail adapters System cabling Bridging the supply voltage Page Configuration software Cables System components 1:1 feed-through terminal block Adapters, cables MINI-MCR-SL-TB 350 347 System components Power terminal, system power supply unit, DIN rail connectors 348 Transparent cover, insert strips, Zack marker strip for flat-ribbon labeling 347 Marking material Mounting material 320 PHOENIX CONTACT Current transformers Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com INTERFACE Analog Product overview MACX Analog / MCR Analog Digital displays PACT Analog Page MACX MCR-UI-UI... MCR-C-UI-UI...-DCI MCR-C-...-DC MCR-FL-C-UI-2UI-DCI MACX MCR-SL-RPSSI-I... MCR-SL-1CLP-I-I-00-4KV MCR-...CLP-I-I-00 MCR-CLP-UI-I-4 358 360 364 362 365 368 369 367 Page MCR-T-UI-... MCR-FL-T-LP-I MCR-FL-HT-T-I MCR-PT100-...(-DC) MCR-SL-PT100-LP-I MCR-SL-HT-PT100-I 370 374 376 372 375 377 Page MCR-F-UI-DC 378 Page MCR-T-UI-... MCR-SL-PT100-SP MCR-PSP-DC MCR-2SP-UI-DC 370 373 380 381 EMG 30-SP-...LIN MCR-PS-24DC-10DC 387 388 Page MCR-FL-D-U-I-2SP-... 383 MCR-SL-D-SPA-UI 386 MCR-FL-D-U-I-2SP-... MCR-SL-D-U-I MCR-SL-D-FIT 383 384 385 Page MCR-S-1-5-UI-...-DCI MCR-S-10-50-UI-...-DCI MACX MCR-SL-CAC-5-I-... MCR-SL-S-...00-U MCR-SL-S-...00-I-LP MCR-SLP-1-5-UI-0 MCR-SL-S-16-SP-24 MCR-VDC-UI-B-DC MCR-VAC-UI-0-DC Page 390 391 393 394 395 396 397 398 399 PACT MCR-V1-... PACT MCR-V2-... PACT MCR-V3-... PACT MCR-V1C-... PACT MCR-V2C-... Page MCR/PI-CONF-WIN Adapter, cable Page Page 389 389 MCR-SL-D-RA DIN rail connectors 403 404 412 413 414 387 PACT MCR-RA 419 Copper sleeves, secondary terminal cover, insulating caps 419 348 Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com PHOENIX CONTACT 321 INTERFACE Analog Basics - technical data Input Maximum input signal The maximum input signal describes the value at which no damage to the module and the signal generator has occurred yet. If these values are exceeded, suppressor diodes, which short circuit this input when a surge voltage is detected, can be triggered. The transmission range of the analog signals is only located within the given input ranges. Input resistance The input resistance of an isolation amplifier or measuring transducer is designed such that the input signal is loaded only slightly. This yields a low-resistance input for current inputs and a highresistance input for voltage inputs. Voltage drop In case of passive isolators, the input voltage drop occurs as a result of the voltage drop of the operational load and the auxiliary power requirements of the module. The more the auxiliary power requirements of the passive isolator, the smaller the operational output load may be. Low auxiliary power requirements are the measure of the quality of a device. Common mode rejection In case of isolation amplifiers, operational amplifiers are used internally for transmission. Theoretically, operational amplifiers have an ideal transmission and amplification behavior. In practice, however, things are different. When both input voltages are changed in the same direction, i.e. exactly the same voltage to ground is applied to both input terminal blocks, this leads to an unintended output signal. Theoretically, no output signal should appear with an ideal operational amplifier, since the differential input signal is "0 V". The common mode rejection indicates the factor (in dB) by which the common input voltage at both inputs is amplified less than the difference in voltage between the two inputs. 322 PHOENIX CONTACT (True) r.m.s. value According to the definition, the r.m.s. value of an alternating current has the same magnitude as a direct current that develops the same heat energy and has the same force effects on other conductors carrying a current. Many measuring transducers measure the rectified mean value which is then adapted to the r.m.s. value. However, this measuring technique is precise only with sinusoidal signals. If distorted and higher frequency and mixed signals can be measured accurately, this is known as true r.m.s. measurement. Binary output Analog output Transistor A PNP transistor switching output transmits 24 V DC switching signals from up to approximately 100 mA. Maximum output signal If the devices operate without disturbances, an override at the input cannot cause greater values at the output. Zero/span adjustment When the zero point is set, the zero point of an analog output is adjusted and set in relation to the input signal. When the "amplification" span is set, the analog output is adjusted in relation to the input signal. In this case, the output characteristic curve is increased or decreased by an amplification factor. Load The load on the output side indicates the load-carrying capacity of a measuring transducer or an isolation amplifier. Current outputs can generally drive a maximum of 500 Ω; voltage outputs can be loaded with a minimum of up to 10 kΩ.. Residual ripple / ripple A superposed ripple can appear on the output signal due to signal conditioning required by the circuit. The residual ripple is given in mVPP or mVrms. Open circuit response With some measuring transducers, the input signal is permanently monitored for possible open circuits in the signal cable. If the signal exceeds or falls below a tolerance limit, an open circuit is detected and a defined output signal is sent. With programmable devices, the output signal can be freely selected. Relay Numerous products with a relay output that are shown in the catalog are made with hard-gold-plated relay contact material. The voltage range is important when utilizing this contact material. When voltage ranges up to 30 V AC/ 36 V DC are used, up to 50 mA can be transmitted. Even very small currents are transmitted perfectly. If the previously mentioned voltage range is exceeded and values of 250 V AC/DC are processed, currents of up to 2 A can flow. The subsequent transmission of small currents, however, can then no longer be guaranteed. General data Supply voltage In the product range, DC and AC power supply units are offered depending on the item. A 24 V DC version is available as a standard power supply unit that works in the voltage range of 20...30 V DC. The different supply voltages can be found in the technical data. Current consumption The value given here describes the auxiliary power requirements of the devices. In addition, there are the output current and the load of the switching output, if any. Transmission error The transmission precision is a gauge of the quality of a measuring transducer. It is the deviation from the ideal transmission characteristic curve and includes linearity, span, and offset errors. Non-linearity Non-linearity is the deviation from the ideal transmission precision without span and offset errors. The non-linearity of a signal makes it possible to evaluate the course from zero to span. Normally, the linearity errors that are given indicate a deviation from the ideal transmission characteristic curve as a percentage. Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com INTERFACE Analog Basics - technical data Temperature coefficient The temperature coefficient evaluates the deviating precision if the ambient temperature around an isolation amplifier or measuring transducer changes. In most cases this data is given as a percentage. An alternative definition is ppm/K (parts per million/Kelvin). Example: 250 ppm/K correspond to 0.025%/K. Limit frequency Isolating amplifiers are basically designed to transmit DC signals. Signal changes, though, require a dynamic behavior that is determined by the limit frequency and therefore offer the possibility of transmitting small AC quantities (normally: 30 Hz) as well. At the same time, a low limit frequency suppresses higher-frequency AC components. Step response The step response indicates the response time of the output signal when an input signal step occurs (10...90%). The step response is inversely proportional to the limit frequency. This means that the response time decreases when the limit frequency increases. Test voltage The test voltage defines the dielectric strength of an isolated distance and is determined by type tests. In this test, a 50 Hz voltage is applied for one minute, and it describes a value at which no disruptive electrical charge to another potential level takes place in the device. Safe isolation "Safe isolation" is defined as protection from currents dangerous to the human body. When modules are specified in accordance with EN 61010, one distinguishes between faultless and disturbed operation. With faultless operation, nominal supply voltages of 30 V AC/ 60 V DC are valid. Ambient temperature range The temperature limits given here are only for operation. These limits do not apply to storage and transport. The temperature limits of the materials used are decisive for those cases. If the devices should be outside of the given temperature range during assembly, they must be brought back to the given temperature range first before the system startup. It is important to make sure that no condensation occurs. Protective circuit In order to protect the MCR modules against surge voltage, suppressor diodes are connected upstream of the signal and supply paths. These diodes behave in a similar manner to conventional Zener diodes. In contrast, the suppressor diode has faster response times and a higher maximum current. Information regarding directives and standards When non-independent items (components) are further processed, the applicable specifications for installation must be observed. For installation in devices, the specifications of the respective device also apply. (Standards that are applicable at the time of printing the catalog) Directives EU International Electromagnetic Compatibility Directive (EMC) 2004/108/EC - Low-voltage directive (LVD) 2006/95/EC - Ex directive (ATEX) 94/9/EC - Electronic equipment for use in electrical power installations and their assembly into electrical power installations EN 50178:1997 - Safety regulations for electrical measurement, control and laboratory equipment Part 1: General requirements EN 61010-1:2001 IEC 61010-1:2004 Programmable logic controllers Part 2: Equipment requirements and tests EN 61131-2:2007 IEC 61131-2:2007 EMC - Part 6-2: Generic standards - noise immunity for industrial sectors EN 61000-6-2:2005 IEC 61000-6-2:2005 EMC - Part 6-4: Generic standards - noise emission for industrial sectors EN 61000-6-4:2007 IEC 61000-6-4:2006 Electrical equipment for measurement systems, control systems and laboratory use EMC requirements EN 61326-1:2006 IEC 61326-1:2005 Electrical operating equipment for potentially gas-explosive areas Part 0: General requirements EN 60079-0:2006 IEC 60079-0:2007 Explosive atmosphere Part 11: Device protection through intrinsic safety "i" EN 60079-11:2007 IEC 60079-11:2006 Electrical operating equipment for potentially gas-explosive areas Part 15: construction, testing and labeling of electrical equipment of the protection type "n" EN 60079-15:2005 IEC 60079-15:2005 Product standards EMC ATEX Environmental tests Environmental factors Part 2-1: Test method - test A: cold EN 60068-2-1:2007 IEC 60068-2-1:2007 Environmental factors Part 2-2: Test method - test B: heat EN 60068-2-2:2007 IEC 60068-2-2:2007 Environmental factors Part 2-6: Test method - test Fc: waves (sinusoidal) EN 60068-2-6:2008 IEC 60068-2-6:2008 Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com PHOENIX CONTACT 323 INTERFACE Analog Basics - isolation Active isolation 3-way isolation Input signal Input isolation IN OUT Output signal Input signal Repeater power supply IN OUT Output signal POWER POWER In the case of modules with this isolation system, all components that are connected to the input, output, or supply are protected from each other against interferences. All three directions (input, output, and supply) are correspondingly electrically isolated from one another. The 3-way isolation provides electrical isolation between the measurement sensor and the controller as well as between the controller and actuator. On the input side, the modules need active signals. On the output side, they provide a filtered and amplified signal. OUT Output signal In the case of modules with this isolation system, the electronics connected on the output side (e.g. the controller) are to be protected from interferences from the field. For this reason, only the input is electrically isolated from the output and the supply, which lie on the same potential. On the input side, the modules need active signals (e.g. from measurement sensors). On the output side, they provide a filtered and amplified signal – e.g. from the controller. Repeater power supplies use the signalinput side not only for measured value acquisition, but also to provide the necessary power to the passive looppowered measurement sensors connected on the input side. On the output side, they provide a filtered and amplified signal – e.g. from the controller. The isolation method of these modules is that of input isolation. Applications Passive isolation, supplied on the input side Input signal IN POWER Passive isolation Feed-in using signal Feeding the measuring transducer Input signal IN OUT Passive isolation, supplied from the output side (loop-powered) Output signal Input signal The modules obtain the power required for signal transmission and electrical isolation from the active input circuit. A conditioned current signal for the controller or for actuators is available on the output side. This passive isolation allows signal conditioning (interrupting of ground loops) and filtering without an additional power supply. Problem: Disruptive radiation I Feed-in using signal IN OUT RE Output signal The modules obtain the power needed for signal transmission and electrical isolation from the active output circuit, ideally from a PLC input card that supplies power. On the output side, the loop-powered modules work with a 4...20 mA standard signal. On the input side, the passive isolator processes active signals. When this isolation technique is used, it is important to make sure that the active signal source connected on the output side (e.g. an active PLC input card) is able to supply power to the passive isolator as well as to operate its load. Solution: I RE Problem: Voltage difference in the ground potential RE PGround 1 Ground current loop P Ground 2 Solution: RE PGround 1 324 PHOENIX CONTACT Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com No ground current loop PGround 2 INTERFACE Analog Basics - temperature Resistance thermometers Resistance thermometer: Resistance change as a function of the temperature Two-wire connection method The resistance i R thermometer is connected to the MCR measuring R transducer using a two-wire conductor. Please note that the cable resistances are added to the measured resistance and consequently distort the result. A distance of 10 m should not be exceeded. L2 Pt 1000 1000 Pt 100 100 800 600 700 400 500 200 300 0 100 -200 Pt 10 -100 Resistance [Ω] L1 10000 Temperature [°C] Resistance thermometers (e.g. Pt100, Ni 1000) change their resistance value depending on the temperature. The MCR temperature transducers detect this change and convert it to a proportional analog signal. To avoid unwanted self-heating of the sensor, the constant measured current used is kept as low as possible (MCR-T-UI... → 250 µA). Example: A 50 m long copper cable with a cross-section of 0.5 mm2 has a specific resistance of 3.4 Ω. A Pt 100 sensor has a resistance change of 0.384 Ω per 1 K temperature change. This corresponds to an error of 8.8°C. Three-wire connection method A three-wire system is i R normally used in order to minimize the influence of the R cable resistances. An R additional conductor is connected to the resistance thermometer, so that the latter is measured using two measurement circuits, one of which acts as a reference. The cable resistance is thus compensated. L1 L2 L3 Identical cable lengths and an identical ambient temperature are essential here. Since this is more or less the case in the majority of applications, the threeconductor system is the one most commonly encountered today. Conductor alignment is not necessary. Four-wire connection method The four-wire connection method is an ideal connection method for resistance thermometers. The measurement result is affected neither by cable resistances nor by their temperature-dependent fluctuations. The voltage drop on the supply and return lines can thus be measured and compensated for separately. Conductor alignment is not necessary. Thermocouples 80 Typ E Typ J 60 Typ K Typ N 40 Typ R Typ T 20 Typ S Typ B 1600 1800 1200 1400 800 1000 400 600 0 200 0 -200 Thermocouple voltage [mV] Thermocouples: Thermocouple voltage change as a function of temperature Temperature [°C] In contrast to the resistance thermometers, thermocouples are active sources that generate a voltage in the mV range. The temperature difference measured between the measurement junction and the cold junction is converted to an absolute temperature with the help of cold junction compensation. Functional principle: If different metals are joined together, a thermal voltage is produced at the metal atoms as a result of the different binding energies of the electrons. This voltage is dependent firstly on the metals themselves and secondly on the temperature. If the same temperature Fe Cu prevails at the measuring junction (ϑ1) and the cold Cu CuNi junction (ϑ2), no current will flow because the generated partial voltages cancel each other out. However, if the temperatures at the measuring junction and the cold junction are different, different voltages are produced. These voltages do not completely cancel each other out, and thus current flows. A thermocouple thus always measures only a temperature difference. This is derived from the difference between the thermal voltages at the measuring junction and at the cold junction. The voltage produced by the thermoelectric effect is very low, only a few microvolts per Kelvin. Only the difference between the thermal voltages of constantan (Cu-Ni) and iron is therefore relevant. A role is also played by the temperature at the terminal point. If it is known, the temperature at the measuring junction can be derived by adding the thermal voltage measured at the same junction. The MCR temperature transducers for thermocouples therefore detect the temperature at the terminal points and compensate this value, which is also referred to as the cold junction. This process is sometimes called cold junction compensation. Example: If a thermocouple type J (FE-CuNi) is connected to a copper terminal, thermal voltages with opposite signs will be generated (at the iron-copper and copper-constantan transitions) and cancel each other out. Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com PHOENIX CONTACT 325 INTERFACE Analog Basics - power Current measurement If purely ohmic loads (incandescent lamps, heaters etc.) are operated in a conventional 230 V power system, no distortions are produced on this system. As non-linear loads increase as a result of phase angle-controlled regulation components, pure sine waves gradually take on a trapezoidal curve shape. The majority of current and voltage transducers are calibrated for sinusoidal alternating currents, so that they can only indicate the r.m.s. value of an alternating current by mean-value generation. True r.m.s. measuring transducers are independent of specific form factors and will accept any curve shape. Measurement of root mean square (r.m.s.) values according to the transformer principle True r.m.s. (TRMS) measurement according to the Rogowski principle True r.m.s. (TRMS) measurement using a Hall sensor Analog out According to Faraday's law of induction, a magnetic flux which changes over the course of time produces an induced voltage at the terminals of a coil. A circuit arrangement consisting of two electrically isolated but magnetically coupled circuits is known as a transformer. This method of current transfer is one of the simplest and most commonly used methods. The Rogowski principle is a special method used to measure sinusoidal and non-sinusoidal alternating currents in a transformer. This non-ferrous induction coil (air-core coil), known as the Rogowski coil, measures the magnetic voltage along a closed circumference around a currentconducting wire. The output signal of the Rogowski coil is then conditioned so that an exact replica of the primary current is obtained. The magnetic flux generated by the primary current IP is condensed in the magnetic circuit and measured in the air gap using a Hall sensor. The output signal of the Hall sensor is then conditioned so that an exact replica of the primary current is obtained. Mean-value generation True r.m.s. value (r.m.s. value) The r.m.s. value of an AC current corresponds to the steady-state value that results from the instantaneous values of this current. This steady-state value generates the same thermal work in an ohmic resistor as a DC current of identical magnitude. The term "true r.m.s. value" simply means that distorted, direct and pulsating currents may also be measured. The measuring transducer is independent of the curve shape. For a sinusoidal AC current this means: I US Irm = S Ur = √2 √2 326 PHOENIX CONTACT Arithmetic average value The arithmetic average value serves to measure DC currents or filter a DC portion from a pulsating current. Using the arithmetic average value on a symmetrical AC current would result in a measured value with the value "0". The arithmetic average value makes it possible to make DC currents available as standard analog signals at the output. The polarity can be evaluated by means of a bipolar output signal. IS Irms Iaverage For the 230 V/50 Hz power system, this means the following for the voltage levels: Urms = 230 V US = 325 V Uaverage = Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com 0V INTERFACE Analog Basics - control Digital displays Parameterization of the characteristic curve with base points With non-linear input signals, the received analog values can be assigned to the value to be displayed by means of a programmable characteristic curve. This curve can consist of up to 24 base points. Flow sensors with a non-linear characteristic curve can be adapted in this way, for instance. The analog signal digital displays in the Function Line additionally feature a summing function which, to take an application example from bottling technology, switches over from the instantaneous value (= flow rate in l/min) to the total flow integrated in the background, and displays this in any unit of measurement on the display at the touch of a key. This saves space and money because there is no need for a second digital display. Limit values too can be called up simply by pressing a key. Limit values 1 and 2 can be assigned to either the actual value or the cumulative value. If the latter value is exceeded, one of the two output relays is energized. Other applications include indicating liquid levels, pressures and temperatures. With servo motors, the analog output signals (0...10 V) generated by the tachogenerator can be supplied to the input of the digital display in order to indicate the motor speed. Application 1: Pressure measurement and display on MCR-SL-DUI 4...20 mA bar Table: Analog signal Base point 1 4 mA 15 bar Base point 2 20 mA 30 bar Display value Characteristic curve: Measured value Use of the freely programmable characteristic curve The freely programmable characteristic curve, i.e. the assignment of the displayed value to the input value, is important in process applications for indicating flow rates or liquid levels. The purpose of level measurements is very often not to determine how much liquid is still inside the tank, but rather to establish how much has been drawn out of it. In this case, the characteristic curve can simply be inverted in order to display the required value. Base point 2 Base point 1 Pressure Application 2: Pressure measurement and display on MCR-FL-D-U-I... Pr1 1 Pr2 2 L min P Flow meter 24 V 0...20 mA Mains voltage Switching behavior of relay or transistor outputs: A different switching behavior can be defined for each relay or each transistor when it reaches a preset switching point. All the possible settings for the switching behavior are shown and explained in the list: – The first two options include a hysteresis, i.e. the behavior of the relay depends on the direction from which a switching point is reached – For the remaining options, with the exception of the last two ("on" and "off"), a switching tolerance is taken into account to prevent the relay contact from "chattering". The relay is not switched until the switching point plus switching tolerance has been reached – In the "on" state, the relay is permanently picked up. It only responds if there is an open circuit and if it has been set to drop in this event – In the "off" state, the relay only responds if there is an open circuit and it has been set to pick up in this event Possible settings for the switching behavior Relay picks up when the value is below SPL, hysteresis active Relay picks up when SPH is exceeded, hysteresis active Relay picks up when value is below SPL Relay picks up when SPL is exceeded Relay picks up when value is below SPH Relay picks up when SPH is exceeded Relay picks up between SPL and SPH Relay picks up outside SPL and SPH Relay is permanently dropped Relay is permanently picked up SPL = Set Point Low (low switching point) SPH = Set Point High (high switching point) Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com PHOENIX CONTACT 327 INTERFACE Analog MINI Analog MINI Analog - Saves space in your control cabinet 328 PHOENIX CONTACT Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com INTERFACE Analog MINI Analog Conversion Temperature Isolation State-of-the-art technology for highest requirements The unit with a design width of only 6.2 mm makes it possible to isolate signals electrically, convert signals, record temperatures or switch threshold values. The MINI Analog range by Phoenix Contact offers these and various other functions. Isolation: – Configurable and standard 3-way isolation amplifiers – Configurable signal duplicators – Repeater power supplies – Passive isolators Power bridging – The bridging from below via DIN rail connectors allows replacement of individual devices without disturbing the group Temperature: – Configurable temperature transducers for Pt 100 – Configurable loop-powered temperature transducers for Pt 100 – Configurable temperature transducers for type J and K thermocouples Conversion: – Configurable analog frequency transducers – Configurable potiposition transducers Features In addition to the extensive range, MINI Analog offers a wide spectrum of features that provide direct operational advantages. In many applications, the analog signal transmission on 6 mm comprises a large number of channels in a small space. Errorfree, time-efficient and cost-saving wiring solutions therefore have utmost significance in this regard. In addition to an intelligent supply concept using a DIN rail connector, the system cabling ensures the lowest wiring cost. DIP switches that can be accessed from the sides allow a simple and quick configuration of modules without complicated software parameterization. Power bridging Operational reliability Operational reliability – 3-way isolation increases the operational reliability in face of disturbances in the system Approvals An extensive approval package allows problem-free usage in different fields. For example, the ATEX approval in accordance with the "n" protection type allows the modules to be used in the Ex zone 2 (gas atmosphere). System cabling System cabling – Time-saving system wiring with the MINI analog system adapter Low current consumption – This results in minimum self-heating and maximum service life. Low current consumption Connection method – Clear wiring thanks to eight connections, with a choice of screw or spring-cage terminal blocks. Control Labeling – Labeling options using Zack marker strips and/or cover with inserted label. Control: – Configurable NAMUR switching amplifiers – Configurable threshold value switches Configuration Modules can either be ordered preconfigured or can be configured using the DIP switches. Connection method Labeling Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com PHOENIX CONTACT 329 INTERFACE Analog MINI Analog Configurable 3-way isolation amplifiers 6,2 Isolation 102,5 93,1 IN U,I U,I OUT MINI MCR-SL-UI-UI SL POWER Configurable 3-way isolation amplifiers uF Ex: X U Housing width 6.2 – – – – Configurable input and output signals 3-way isolation Low power consumption Power supply possible through the foot element (T-Connector) IN UI 1 GND1 2 I,U U U,I 5 OUT UI 6 GND2 DC DC solid Screw connection Spring-cage conn. stranded [mm2] AWG 0.14-2.5 0.2-2.5 26-12 0.2-2.5 0.2-2.5 24-12 Screw M3 DC 7 UB + 8 GND3 UB + 3 GND3 4 ME 6,2 TBUS-... The MINI MCR-SL-UI-UI three-way isolation amplifiers are used for electrical isolation, conversion, amplification and filtering of standard signals. The devices that can be adjusted via DIP switches are electrically isolated from each other in the input, output and supply circuit. A new type of connection concept makes the devices very low-loss with regard to their power consumption. This is expressed in low self-heating and has a significant influence on the service life. Thanks to the possibility of power bridging via the foot element, the devices can be connected to the power supply both simply and quickly. The desired input and output signal combination must be specified when ordering pre-configured modules (refer to the order key). If specification details are incorrect or missing, the devices will be supplied with the standard configuration (input signal 0...10 V, output signal 0...20 mA). Accessories: Information about components for energy bridging, system cabling and marking is given from page 347. Description Type Order No. MCR 3-way isolation amplifier, for electrical isolation of analog signals, Order configuration Screw connection Order configuration Spring-cage conn. Standard configuration Screw connection Standard configuration Spring-cage conn. MINI MCR-SL-UI-UI MINI MCR-SL-UI-UI-SP MINI MCR-SL-UI-UI-NC MINI MCR-SL-UI-UI-SP-NC 2864383 2864710 2864150 2864163 Technical data Input data Input signal Input resistance Output data Output signal Maximum output signal No-load voltage Short-circuit current Load RB Ripple General data Supply voltage UB Nominal supply voltage Current consumption Power consumption Transmission error, max. Temperature coefficient Limit frequency (3 dB) Step response (10-90%) Test voltage, input/output/supply Degree of protection Ambient temperature (operation) Assembly Housing material Conformance / approvals Conformity ATEX UL, USA / Canada GL 330 PHOENIX CONTACT U input 0 ... 5 V / 1 ... 5 V 0 ... 10 V / 2 ... 10 V Approx. 100 kΩ U output 0 ... 5 V / 1 ... 5 V 0 ... 10 V / 2 ... 10 V Approx. 12.5 V Approx. 22 mA ≥ 10 kΩ < 20 mVPP (on 10 kOhm) U output 19.2 V DC ... 30 V DC 24 V DC < 9 mA (Voltage output, at 24 V DC incl. load) < 200 mW (Voltage output) ≤ 0.1% (of end value) < 0.01%/K, Typ. < 0.002%/K Approx. 100 Hz Approx. 3.2 ms 1.5 kV (50 Hz, 1 min.) IP20 -20°C ... 65°C Any PBT I input 0 ... 20 mA / 4 ... 20 mA Approx. 50 Ω I output 0 ... 20 mA / 4 ... 20 mA 28 mA Approx. 12.5 V < 500 Ω (at 20 mA) < 20 mVPP (at 500 Ω) I output < 19 mA (Current output, at 24 V DC incl. load) < 450 mW (Current output) CE compliant X II 3 G Ex nA II T4 X UL 508 Recognized Class I, Div. 2, Groups A, B, C, D T5 GL EMC 2 D Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com Pcs. / Pkt. 1 1 1 1 INTERFACE Analog MINI Analog Order key MINI MCR-SL-UI-UI (Standard configuration entered as example) Input Order No. 2864383 Output / 2864383 = ...-UI-UI IN03 IN01 IN02 IN03 IN04 IN05 IN06 2864710 = ...-UI-UI-SP = = = = = = 0...20 mA 4...20 mA 0...10 V 2...10 V 0...5 V 1...5 V Factory calibration certificate / OUT01 / NONE NONE = Without certificate OUT01 = 0...20 mA YES = With factory calibration OUT02 = 4...20 mA certificate (fee) OUT03 = 0...10 V OUT04 = 2...10 V YESPLUS = Factory calibration certificate OUT05 = 0...5 V with 5 measuring OUT06 = 1...5 V points (fee) Combination table for input and output signals Input 0 - 10 V Output 0 - 20 mA 4 - 20 mA 0 - 10 V 2 - 10 V 0-5V 1-5V 0 - 20 mA 4 - 20 mA 0 - 10 V 2 - 10 V 0-5V 1-5V 0 - 20 mA 4 - 20 mA 0 - 10 V 2 - 10 V 0-5V 1-5V 0 - 20 mA 4 - 20 mA 0 - 10 V 2 - 10 V 0-5V 1-5V 0 - 20 mA 4 - 20 mA 0 - 10 V 2 - 10 V 0-5V 1-5V 0 - 20 mA 4 - 20 mA 0 - 10 V 2 - 10 V 0-5V 1-5V 2 - 10 V 0-5V 1-5V 0 - 20 mA 4 - 20 mA DIP 1 OFF OFF ON ON ON ON OFF OFF ON ON ON ON OFF OFF ON ON ON ON OFF OFF ON ON ON ON OFF OFF ON ON ON ON OFF OFF ON ON ON ON DIP switch SW 2 DIP 3 DIP 4 OFF OFF OFF OFF ON OFF ON OFF OFF OFF OFF OFF OFF ON OFF OFF ON ON ON OFF OFF ON OFF OFF OFF OFF OFF OFF ON OFF ON OFF OFF OFF OFF OFF OFF ON OFF OFF ON ON ON OFF OFF ON OFF OFF OFF OFF OFF OFF ON OFF ON OFF OFF OFF OFF OFF OFF ON OFF OFF ON ON ON OFF OFF ON OFF OFF DIP 2 OFF OFF OFF OFF ON ON OFF OFF OFF OFF ON ON OFF OFF OFF OFF ON ON OFF OFF OFF OFF ON ON OFF OFF OFF OFF ON ON OFF OFF OFF OFF ON ON DIP 5 OFF OFF OFF OFF OFF OFF ON OFF ON OFF ON OFF OFF OFF OFF OFF OFF OFF ON OFF ON OFF ON OFF OFF OFF OFF OFF OFF OFF ON OFF ON OFF ON OFF DIP switch SW 1 DIP 1 DIP 2 OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON DIP 6 OFF ON OFF ON OFF ON OFF OFF OFF OFF OFF OFF OFF ON OFF ON OFF ON OFF OFF OFF OFF OFF OFF OFF ON OFF ON OFF ON OFF OFF OFF OFF OFF OFF Application example: Level measurement 24V Level sensor 0...10V 0...20mA 1 IN OUT 5 2 GND1 GND2 6 Control system 3 UB+ UB+ 7 4 GND3 GND3 8 MINI MCR-SL-UI-UI 24V Mains voltage Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com PHOENIX CONTACT 331 INTERFACE Analog MINI Analog Configurable 3-way isolation amplifiers 6,2 Isolation 102,5 93,1 IN U U,I OUT MINI MCR-SL-SHUNT-UI SL POWER Configurable 3-way isolation amplifiers uF Housing width 6.2 – Conversion from mV voltages into standard signals – Configurable input and output signals – 3-way isolation – Low power consumption – Power supply possible through the foot element (T-Connector) The MINI MCR-SL-SHUNT-UI 3-way isolation amplifiers convert mV voltages into standard signals. Amplification, filtering and electrical isolation of signals takes place here. These devices make it possible to record direct currents flowing through a shunt resistor. The resulting voltage drop of a few millivolts is converted into a standard signal using an isolation amplifier and can be forwarded by a control system. The DIP switch accessible on the housing side allows the configuration of the input signal ranges and the desired output signal. The desired configuration must be specified when ordering pre-configured modules (refer to the order key). If specifications are incorrect or missing, the devices will be supplied with the standard configuration. Accessories: Information about components for energy bridging, system cabling and marking is given from page 347. IN U 1 GND1 2 PHOENIX CONTACT U,I 5 OUT UI 6 GND2 DC DC solid Screw connection Spring-cage conn. stranded [mm2] AWG 0.14-2.5 0.2-2.5 26-12 0.2-2.5 0.2-2.5 24-12 Screw M3 DC 7 UB + 8 GND3 UB + 3 GND3 4 ME 6,2 TBUS-... Description Type Order No. MCR-3-way isolation amplifier, for realization of mV voltages in standard signals, Order configuration Screw connection Order configuration Spring-cage conn. Standard configuration Screw connection Standard configuration Spring-cage conn. MINI MCR-SL-SHUNT-UI MINI MCR-SL-SHUNT-UI-SP MINI MCR-SL-SHUNT-UI-NC MINI MCR-SL-SHUNT-UI-SP-NC 2810858 2810874 2810780 2810793 Technical data Input data Input signal (configurable using the DIP switch) Maximum input signal Input resistance Output data Output signal (configurable using the DIP switch) Maximum output signal Load RB Ripple General data Supply voltage UB Nominal supply voltage Power consumption Transmission error, max. Temperature coefficient Limit frequency (3 dB) Step response (10-90%) Test voltage, input/output/supply Degree of protection Ambient temperature (operation) Ambient temperature (storage/transport) Assembly Housing material Conformance / approvals Conformity ATEX UL, USA / Canada GL 332 Ex: X // Applied for: UL-EX LIS / CUL-EX LIS Pcs. / Pkt. 0 ... 50 mV, please indicate any different setting when ordering Approx. 30 V DC Approx. 100 kΩ U output I output 0 ... 5 V / 1 ... 5 V 0 ... 20 mA / 4 ... 20 mA 0 ... 10 V / 2 ... 10 V -5 ... 5 V / -10 ... 10 V (The bi-polar output can be used only for bi-polar input signals.) 12.5 V ≥ 10 kΩ < 20 mVPP (on 10 kOhm) 28 mA < 500 Ω (at 20 mA) < 20 mVPP (at 500 Ω) 19.2 V DC ... 30 V DC 24 V DC < 450 mW (Current output) ≤ 0.2% < 0.01%/K (100 Hz / 30 Hz switchable) 3.5 ms (at 100 Hz) 1.5 kV (50 Hz, 1 min.) IP20 -20°C ... 65°C -40°C ... 85°C Any PBT CE compliant X II 3 G Ex nA II T4 X UL 508 Recognized Class I, Zone 2, Groups A, B, C, D T5 applied for GL EMC 2 D Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com 1 1 1 1 INTERFACE Analog MINI Analog Order key MINI MCR-SL-SHUNT-UI-... (Standard configuration entered as example) Input Order No. 2810858 2810858 = ...-SHUNT-UI 2810874 = ...-SHUNT-UI-SP Output / IN40 IN40 IN24 IN41 IN42 IN25 IN43 IN44 IN26 IN45 IN27 = = = = = = = = = = 0...50 mV 0...60 mV 0...75 mV 0...80 mV 0...100 mV 0...120 mV 0...150 mV 0...200 mV 0...240 mV 0...300 mV IN28 IN46 IN47 IN48 IN29 IN49 IN50 IN30 IN51 IN52 = = = = = = = = = = 0...500 mV 0...600 mV 0...750 mV 0...800 mV 0...1.0 V 0...1.2 V 0...1.5 V 0...2.0 V 0...2.4 V 0...3.0 V IN53 IN13 IN54 IN55 IN14 IN56 IN57 IN15 IN58 IN16 / = = = = = = = = = = -50...+50 mV -60...+60 mV -75..+75 mV -80...+80 mV -100..+100 mV -120...+120 mV -150...+150 mV -200...+200 mV -240...+240 mV -300...+300 mV IN17 IN59 IN60 IN61 IN18 IN62 IN63 IN19 IN64 IN65 = = = = = = = = = = -500...+500 mV -600...+600 mV -750...+750 mV -800...+800 mV -1.0...+1.0 V -1.2...+1.2 V -1.5...+1.5 V -2.0...+2.0 V -2.4...+2.4 V -3.0...+3.0 V Limit frequency OUT01 OUT01 OUT02 OUT03 OUT04 OUT05 OUT06 = = = = = = 0...20 mA 4...20 mA 0...10 V 2...10 V 0...5 V 1...5 V / 100 30 = 30 Hz 100 = 100 Hz OUT13 = -5...+5 V OUT14 = -10...+10 V Factory calibration certificate / NONE = Without certificate = With factory calibration certificate (fee) YESPLUS = Factory calibration certificate with 5 measuring points (fee) NONE YES Note: A bipolar output (-5...+5 V, -10...+10 V) is useful only in case of a bipolar input signal. Combination table for input and output signals Input 0...50 mV 0...60 mV 0...75 mV 0...80 mV 0...100 mV 0...120 mV 0...150 mV 0...200 mV 0...240 mV 0...300 mV 0...500 mV 0...600 mV 0...750 mV 0...800 mV 0...1 V 0...1.2 V 0...1.5 V 0...2 V 0...2.4 V 0...3 V -50...50 mV -60...60 mV -75...75 mV -80...80 mV -100...100 mV -120...120 mV -150...150 mV -200...200 mV -240...240 mV -300...300 mV -500...500 mV -600...600 mV -750...750 mV -800...800 mV -1...1 V -1.2...1.2 V -1.5...1.5 V -2...2 V -2.4...2.4 V -3...3 V -10...+10 V x x x x x x x x x x x x x x x x x x x x Voltage output 2...10 V -5...+5 V x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x 0...10 V x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x 0...5 V x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x Current output 0...20 mA 4...20 mA x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x 1...5 V x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x Application example: Monitoring of loading and discharging currents G M Shunt resistor 1 IN OUT 5 ±...mV U/I 2 GND1 GND2 6 Control system + – 3 UB+ UB+ 7 4 GND3 GND3 8 MINI MCR-SL-SHUNT-UI 24V Battery Supply Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com PHOENIX CONTACT 333 INTERFACE Analog MINI Analog Configurable 3-way isolation amplifiers 93,1 Isolation 102,5 6,2 IN U U,I OUT MINI MCR-SL-U-UI POWER SL Configurable 3-way isolation amplifiers uF Ex: X U Housing width 6.2 – – – – – Processing voltages of up to 30 V Configurable input and output signals 3-way isolation Low power consumption Power supply possible through the foot element (T-Connector) The MINI MCR-SL-U-UI 3-way isolation amplifiers are used for electrical isolation, conversion, amplification and filtering of voltages up to 30 V. These can be the output voltages of power supply units or UPS. The devices that can be adjusted via DIP switches are electrically isolated from each other in the input, output and supply circuit. This 3-way isolation prevents different sensor circuits interfering with each other and thereby improves the quality of your measuring circuit. The desired configuration must be specified when ordering pre-configured modules (refer to the order key). If specifications are incorrect or missing, the devices will be supplied with the standard configuration. Accessories: Information about components for energy bridging, system cabling and marking is given from page 347. IN U 1 GND1 2 Screw connection Spring-cage conn. OUT DC Screw M3 2 GND1 GND2 Type Order No. MCR 3-way isolation amplifier, for electrical isolation of analog signals, Order configuration Screw connection Order configuration Spring-cage conn. Standard configuration Screw connection Standard configuration Spring-cage conn. MINI MCR-SL-U-UI MINI MCR-SL-U-UI-SP MINI MCR-SL-U-UI-NC MINI MCR-SL-U-UI-SP-NC 2864053 2811213 2865007 2810078 Technical data Input data Input signal Input resistance Output data Output signal (configurable using the DIP switch) 0 ... 24 V / 0 ... 30 V Approx. 125 kΩ U output 0 ... 5 V / 1 ... 5 V 0 ... 10 V / 2 ... 10 V ≤ 12.5 V Maximum output signal No-load voltage Short-circuit current Load RB Ripple General data Supply voltage UB Power consumption Transmission error, max. Temperature coefficient Limit frequency (3 dB) Step response (10-90%) Test voltage, input/output/supply Ambient temperature (operation) Housing material Conformance / approvals Conformity ATEX UL, USA / Canada 3 UB+ 2864053 = ...-U-UI 6 UB + 7 2811213 = ...-U-UI-SP 4 GND3 GND3 MINI MCR-SL-U-UI 8 24V ≤ 22 mA > 10 kΩ < 20 mVPP (on 10 kOhm) Output IN39 IN38 IN39 = 0...24 V = 0...30 V / OUT01 OUT01 OUT02 OUT03 OUT04 OUT05 OUT06 = = = = = = 0...20 mA 4...20 mA 0...10 V 2...10 V 0...5 V 1...5 V Mains voltage PHOENIX CONTACT 28 mA ≤ 12.5 V < 500 Ω (at 20 mA) < 20 mVPP (at 500 Ω) CE compliant X II 3 G Ex nA II T4 X UL 508 Recognized Class I, Div. 2, Groups A, B, C, D T5 GL EMC 2 D Input / I output 0 ... 20 mA / 4 ... 20 mA 19.2 V DC ... 30 V DC < 450 mW < 0.1% (of end value) < 0.01%/K, Typ. < 0.002%/K 100 Hz Approx. 3.5 ms 1.5 kV (50 Hz, 1 min.) -20°C ... 65°C PBT Signal conversion to uninterruptible power supply (UPS) 334 7 UB + 8 GND3 UB + 3 GND3 4 Description 2864053 5 5 OUT UI 6 GND2 ME 6,2 TBUS-... Order No. 0...10V IN U U,I DC DC stranded [mm2] AWG 0.14-2.5 0.2-2.5 26-12 0.2-2.5 0.2-2.5 24-12 Order key MINI MCR-SL-U-UI (Standard configuration entered as example) 1 U solid GL 0...24V U Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com Pcs. / Pkt. 1 1 1 1 INTERFACE Analog MINI Analog Standard signal 3-way isolation amplifiers 93,1 Isolation 102,5 6,2 IN U,I U,I OUT MINI MCR-SL-U-I(I-U) SL POWER 3-way isolation amplifier uF Ex: X // Applied for: UL-EX LIS / CUL-EX LIS Housing width 6.2 – – – – – Processing standard signals Fixed setting of input and output signals 3-way isolation Low power consumption Power supply possible through the foot element (T-Connector) The MINI MCR-SL-U-I(I-U) 3-way isolation amplifiers are used for electrical isolation, conversion, amplification and filtering of analog standard signals. The devices are electrically isolated from each other in the input, output and supply circuit. A new type of connection concept makes the devices very low-loss with regard to their power consumption. This is expressed in low self-heating and has a significant influence on the service life. Thanks to the possibility of power bridging via the foot element, the devices can be connected to the power supply both simply and quickly. IN 1 GND1 2 DC DC Screw connection Spring-cage conn. stranded [mm2] AWG 0.14-2.5 0.2-2.5 26-12 0.2-2.5 0.2-2.5 24-12 Screw M3 DC 7 UB + 8 GND3 UB + 3 GND3 4 ME 6,2 TBUS-... Description Order No. MCR 3-way isolation amplifier, for electrical isolation of analog signals, Screw connection 0 ... 10 V 0 ... 20 mA Spring-cage conn. 0 ... 10 V 0 ... 20 mA MINI MCR-SL-U-I-0 MINI MCR-SL-U-I-0-SP 2813512 2813570 1 1 Screw connection Spring-cage conn. 0 ... 10 V 0 ... 10 V 4 ... 20 mA 4 ... 20 mA MINI MCR-SL-U-I-4 MINI MCR-SL-U-I-4-SP 2813525 2813583 1 1 Screw connection Spring-cage conn. 0 ... 20 mA 0 ... 20 mA 0 ... 10 V 0 ... 10 V MINI MCR-SL-I-U-0 MINI MCR-SL-I-U-0-SP 2813541 2813554 1 1 Screw connection Spring-cage conn. 4 ... 20 mA 4 ... 20 mA 0 ... 10 V 0 ... 10 V MINI MCR-SL-I-U-4 MINI MCR-SL-I-U-4-SP 2813538 2813567 1 1 Screw connection 0 ... 20 mA, 4 ... 20 mA 0 ... 20 mA, 4 ... 20 mA 0 ... 10 V, -10 ... 10 V 0 ... 10 V, -10 ... 10 V 0 ... 20 mA, 4 ... 20 mA 0 ... 20 mA, 4 ... 20 mA 0 ... 10 V, -10 ... 10 V 0 ... 10 V, -10 ... 10 V MINI MCR-SL-I-I 2864406 1 MINI MCR-SL-I-I-SP 2864723 1 MINI MCR-SL-U-U 2864684 1 MINI MCR-SL-U-U-SP 2864697 1 Spring-cage conn. Spring-cage conn. Technical data Input data Input resistance Output data Maximum output signal No-load voltage Short-circuit current Load RB Ripple General data Supply voltage UB Nominal supply voltage Current consumption Transmission error, max. Temperature coefficient Limit frequency (3 dB) Step response (10-90%) Degree of protection Test voltage, input/output/supply Ambient temperature (operation) Housing material Conformance / approvals Conformity ATEX UL, USA / Canada GL Input signal Output signal Pcs. / Pkt. Type Screw connection Accessories: Information about components for energy bridging, system cabling and marking is given from page 347. 5 OUT 6 GND2 U U input Approx. 100 kΩ U output 12.5 V Approx. 2 mA ≥ 10 kΩ < 20 mVPP (on 10 kOhm) I input Approx. 50 Ω I output 28 mA Approx. 12.5 V ≤ 500 Ω < 20 mVPP (at 500 Ω) 19.2 V DC ... 30 V DC 24 V DC < 20 mA ≤ 0.1% (of end value) < 0.01%/K, Typ. < 0.002%/K Approx. 100 Hz Approx. 3.5 ms IP20 1.5 kV (50 Hz, 1 min.) -20°C ... 65°C PBT CE compliant X II 3 G Ex nA II T4 X UL 508 Recognized Class I, Div. 2, Groups A, B, C, D T5 applied for GL EMC 2 D Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com PHOENIX CONTACT 335 INTERFACE Analog MINI Analog Configurable signal duplicator 93,1 6,2 102,5 OUT1 Isolation I IN U,I OUT2 I MINI MCR-SL-UI-2I POWER SL Configurable signal duplicator uF Ex: X U Housing width 6.2 URef – – – – Configurable input and output signals 4-way isolation Two current output signals Power supply possible through the foot element (T-Connector) The MINI MCR-SL-UI-2I 4-way signal duplicators are used for electrical isolation, duplicating and filtering of analog standard signals. The devices are electrically isolated from each other in the input, output and supply circuit. 4-way isolation prevents different sensor circuits interfering with each other and thereby improves the quality of your measuring circuit. The input signal can be switched over between the current and voltage signal via a DIP switch and the two current output signals can be switched independently between 0...20 mA and 4...20 mA. The desired configuration must be specified when ordering pre-configured modules (refer to the order key). If specifications are incorrect or missing, the devices will be supplied with the standard configuration. Accessories: Information about components for energy bridging, system cabling and marking is given from page 347. IN UI 1 2 solid Screw connection Spring-cage conn. stranded [mm2] AWG 0.14-2.5 0.2-2.5 26-12 0.2-2.5 0.2-2.5 24-12 Input 2864794 = ...-UI-2I 2864804 = ...-UI-2I-SP 1) / IN03 IN01 IN02 IN03 IN06 = = = = 0...20 mA 4...20 mA 0...10 V 1...5 V OUT I2 3 GND2 4 PHOENIX CONTACT DC DC DC DC 7 UB + 8 GND4 Type Order No. MCR signal duplicator, for duplicating and electrical isolation of analog signals Order configuration Screw connection Order configuration Spring-cage conn. Standard configuration Screw connection Standard configuration Spring-cage conn. MINI MCR-SL-UI-2I MINI MCR-SL-UI-2I-SP MINI MCR-SL-UI-2I-NC MINI MCR-SL-UI-2I-SP-NC 2864794 2864804 2864176 2864189 Technical data Input data Input signal Maximum input signal Input resistance Output data Output signal (configurable using the DIP switch) Maximum output signal No-load voltage Load RB Ripple General data Supply voltage UB Current consumption Power consumption Transmission error, max. Temperature coefficient Limit frequency (3 dB) Step response (10-90%) Test voltage, input/output/supply Ambient temperature (operation) Housing material Conformance / approvals Conformity ATEX UL, USA / Canada 0 = Analog behavior 1 = Limit Factory calibration certificate / NONE NONE = Without certificate YES = With factory calibration certificate (fee) YESPLUS = Factory calibration certificate with 5 measuring points (fee) U input 0 ... 10 V / 1 ... 5 V 30 V Approx. 100 kΩ I input 0 ... 20 mA / 4 ... 20 mA 50 mA Approx. 50 Ω 2x ; 0 ... 20 mA / 4 ... 20 mA 24 mA 9V ≤ 250 Ω (at 20 mA) < 20 mVPP (at 250 Ω) 19.2 V DC ... 30 V DC < 25 mA (at 24 V DC incl. load) < 600 mW ≤ 0.2% (of end value), Typ. < 0.1% < 0.01%/K, Typ. < 0.004%/K Approx. 35 Hz Approx. 10 ms 1.5 kV (50 Hz, 1 min.) -20°C ... 60°C PBT CE compliant X II 3 G Ex nA II T4 X UL 508 Recognized Class I, Div. 2, Groups A, B, C, D T5 GL EMC 2 D Explanation of the output combination: Output 1 A 0...20 mA B 0...20 mA C 4...20 mA For explanations see adjacent text on the right, for further details see data sheet: www.phoenixcontact.com 336 5 OUT I1 6 GND1 mC Description Output Behavior of the analog combination 1) outputs / A / 0 A B C D ME 6,2 TBUS-... GL Order key MINI MCR-SL-UI-2I (Standard configuration entered as example) Order No. 2864794 Screw M3 A Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com Output 2 0...20 mA 4...20 mA 4...20 mA Pcs. / Pkt. 1 1 1 1 INTERFACE Analog MINI Analog Repeater power supply with and without HART 6,2 102,5 Isolation 93,1 POWER I OUT I IN MINI MCR-SL-RPSS-I-I POWER SL Repeater power supply for supplying 2 and 3-conductor transmitters with HART transmission Ex: X Housing width 6.2 IN 1 – 3-way isolation – Supplying of 2 or 3-conductor transmitters – lternatively bidirectional HART transmission – Power supply possible through the foot element (T-Connector) Sensor Power solid Screw connection Spring-cage conn. stranded [mm2] AWG 0.14-2.5 0.2-2.5 26-12 0.2-2.5 0.2-2.5 24-12 Description MCR repeater power supplies with HART® protocol with HART® protocol Technical data Input data Input signal 4...20mA 3 4 OUT I 5 GND2 GND1 UB + GND1 6 GND3 MINI MCR-SL-RPSS-I-I Control system 7 7 UB + 8 GND3 8 24V Screw connection Spring-cage conn. Screw connection Spring-cage conn. Type Order No. MINI MCR-SL-RPSS-I-I MINI MCR-SL-RPSS-I-I-SP MINI MCR-SL-RPS-I-I MINI MCR-SL-RPS-I-I-SP 2864079 2810230 2864422 2864752 Pcs. / Pkt. 1 1 1 1 MINI MCR-SL-RPS-I-I 0 ... 20 mA, isolator operation / 4 ... 20 mA Approx. 50 Ω 16.5 V 0 ... 20 mA, isolator operation / 4 ... 20 mA Approx. 50 Ω 14.7 V DC ... 25.5 V DC (UB max. 4.5 V for load 0 mA ... 20 mA) 0 ... 20 mA / 4 ... 20 mA 21 mA Approx. 12.5 V ≤ 500 Ω (at I = 20 mA) < 20 mVrms (at 500 Ω) 0 ... 20 mA / 4 ... 20 mA 28 mA Approx. 12.5 V ≤ 500 Ω (at I = 20 mA) < 20 mVrms (at 500 Ω) 20.4 V DC ... 30 V DC 24 V DC 19.2 V DC ... 30 V DC 24 V DC < 900 mW (at 24 V DC and in repeater power supply operation) ≤ 0.2% (of end value), Typ. ≤ 0.1% (of end value) < 0.005%/K, Typ. < 0.002%/K > 125 Hz (typ.) HART specification in both operating modes (RPSS isolator / RPSS repeater power supply) < 900 mW (at 24 V DC and in repeater power supply operation) ≤ 0.2% (of end value), Typ. ≤ 0.1% (of end value) < 0.01%/K, Typ. < 0.002%/K Approx. 100 Hz - Step response (10-90%) Test voltage, input/output/supply Degree of protection Ambient temperature (operation) Assembly Housing material Conformance / approvals Conformity ATEX UL, USA / Canada < 2 ms (typ.) 1.5 kV (50 Hz, 1 min.) IP20 -20°C ... 60°C Any PBT Approx. 3.5 ms 1.5 kV (50 Hz, 1 min.) IP20 -20°C ... 60°C Any PBT CE compliant X II 3 G Ex nA II T4 X - GL - CE compliant X II 3 G Ex nA II T4 X UL 508 Recognized Class I, Div. 2, Groups A, B, C, D T5 GL EMC 2 D Input resistance Transmitter supply voltage Output data Output signal Maximum output signal No-load voltage Load RB Ripple General data Supply voltage UB Nominal supply voltage Power consumption Temperature coefficient Limit frequency (3 dB) Communication IN I DC GND1 3 GND1 4 MINI MCR-SL-RPSS-I-I Transmission error, max. Power OUT DC DC OUT 2 Screw M3 ME 6,2 TBUS-... Accessories: Information about components for energy bridging, system cabling and marking is given from page 337. 1 5 OUT I 6 GND2 U The MINI MCR-SL-RPS(S)-I-I repeater power supplies have the task of supplying 2 or 3-conductor transmitters located in the field and transmitting the analog signals electrically isolated from the transmitter. Besides this basic function, the MINI MCR-SL-RPSS-I-I repeater power supply is also capable of transmitting the HART protocol bidirectionally. For this, the digital signals of data communication are super imposed on the analog current signals. In addition, a pure isolator operation is also possible. Both devices are electrically isolated from each other in the input, output and supply circuit. 2 Sensor I Mains voltage Repeater power supply operation with a passive sensor Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com PHOENIX CONTACT 337 INTERFACE Analog MINI Analog One and two-channel passive isolators 6,2 Isolation 102,5 93,1 IN I I OUT MINI MCR-SL-...CP-I-I SL One or two-channel passive isolators uF Ex: u Housing width 6.2 OUT IN – Electrical isolation without additional auxiliary power supply – Current signals 0(4)...20 mA – One and two-channel versions – Input loop-supplied = 5 (+) 0-20mA 6 (–) GND (+) 0-20mA 1 2 (–) GND = 5 (+) 0-20mA 6 (–) GND solid Screw connection Spring-cage conn. The MINI MCR-SL-...CP-I-I passive isolators are used for electrical isolation and filtering of analog 0(4)...20 mA standard signals. The devices perform electrical isolation between the control electronics and process peripherals. Furthermore, interference signal parts above 75 Hz are effectively suppressed. Input and output circuits do not require separate auxiliary power, the modules obtain it from the input signal. When passive loop-powered isolators are used, one must make sure that the current sourcing voltage of the measuring transducer UB is sufficient to drive the maximum current of 20 mA via the passive loop-powered isolator with the voltage drop UV = 1.7 V and the load RB. This means: UB ≥ UE = 1.7 V + 20 mA x RB stranded [mm2] AWG 0.14-2.5 0.2-2.5 26-12 0.2-2.5 0.2-2.5 24-12 (+) 0-20mA 1 2 (–) GND Screw M3 (+) 0-20mA 3 4 (–) GND Description Type Order No. MCR passive isolator, for electrical isolation of current signals without auxiliary power two-channel Screw connection two-channel Spring-cage conn. single-channel Screw connection single-channel Spring-cage conn. MINI MCR-SL-2CP-I-I MINI MCR-SL-2CP-I-I-SP MINI MCR-SL-1CP-I-I MINI MCR-SL-1CP-I-I-SP 2864655 2864781 2864419 2864749 Technical data Input data Input signal Voltage drop Response current Maximum input current / overload Maximum input voltage Output data Output signal Load RB Ripple General data Transmission error, max. Additional error per 100 Ω load Temperature coefficient Limit frequency (3 dB) Step response (10-90%) Test voltage input/output Degree of protection Ambient temperature (operation) Assembly Housing material Conformance / approvals Conformity UL, USA / Canada GL 0 ... 20 mA / 4 ... 20 mA 1.7 V (at I = 20 mA) Approx. 190 µA 40 mA 18 V 0 ... 20 mA / 4 ... 20 mA < 600 Ω (at I = 20 mA output signal) < 10 mVrms (at 600 Ω) ≤ 0.1% (of end value) 0.03% (of measured value / 100 Ω load) ≤ 0.002%/K (of measured value / 100 Ω load) 75 Hz 5 ms (at 600 Ω load) 1.5 kV (50 Hz, 1 min.) IP20 -20°C ... 65°C Any PBT CE compliant UL 508 Recognized GL EMC 2 D UB UV = 1,7 V I UE I I RB I MINI MCR-SL-1CP-I-I 338 PHOENIX CONTACT 7 (+) 0-20mA 8 (–) GND = Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com Pcs. / Pkt. 1 1 1 1 INTERFACE Analog MINI Analog Configurable temperature transducer for Pt 100 6,2 102,5 Temperature 93,1 IN U,I OUT PT100 SL MINI MCR-SL-PT100-UI-200 POWER Configurable temperature transducer for Pt 100 temperature sensors for measuring ranges of -50...200°C uF Ex: X U Housing width 6.2 The MINI MCR-SL-PT100-UI-200 temperature transducers convert the measured values of Pt 100 sensors (IEC 60751/EN 60751) into analog standard signals. These temperature transducers are optimized for measuring ranges of -50 to 200°C. 2, 3 and 4-conductor Pt 100 sensors can be connected to the input. The DIP switches are accessible at the side of the housing and allow the following parameters to be configured: Connection method, temperature span to be measured, output signal, and type of error evaluation. The desired configuration must be specified when ordering pre-configured modules (refer to the order key). If specifications are incorrect or missing, the devices will be supplied with the standard configuration. Accessories: Information about components for energy bridging, system cabling and marking is given from page 347. 1 2 3 Screw connection Spring-cage conn. stranded [mm2] AWG 0.14-2.5 0.2-2.5 26-12 0.2-2.5 0.2-2.5 24-12 Screw M3 Description 2 Wire Pt 100 solid 4 Wire Pt 100 Measuring ranges from –50°C to 200°C 2, 3 or 4-conductor Pt 100 sensors Configurable output signals 3-way isolation Diagnostics LED and fault evaluation Power supply possible through the foot element (T-Connector) 3 Wire Pt 100 – – – – – – Iref A D 5 OUT UI 6 GND1 mC 4 DC DC DC 7 UB+ 8 GND2 ME 6,2 TBUS-... Type Order No. MINI MCR-SL-PT100-UI-200 MINI MCR-SL-PT100-UI-200-SP MINI MCR-SL-PT100-UI-200-NC MINI MCR-SL-PT100-UI-200-SP-NC 2864309 2864192 2864370 2864202 Pcs. / Pkt. MCR temperature transducer, for PT100 temperature sensors Order configuration Order configuration Unconfigured Unconfigured Screw connection Spring-cage conn. Screw connection Spring-cage conn. Technical data Input data Input signal (configurable via DIP switch) Temperature range Measuring range span Output data Output signal (configurable via DIP switch) Maximum output signal Load RB Ripple General data Supply voltage UB Current consumption Power consumption Transmission error for the full/set measurement range Temperature coefficient Step response (10-90%) Test voltage, input/output/supply Ambient temperature (operation) Housing material Conformance / approvals Conformity ATEX UL, USA / Canada GL 1 1 1 1 Pt 100 (IEC 60751/EN 60751) : 2, 3, 4-wire -50°C ... 200°C (configurable) Min. 50 K I output U output 0 ... 20 mA / 4 ... 20 mA 0 ... 5 V / 1 ... 5 V 20 ... 0 mA / 20 ... 4 mA 0 ... 10 V / 10 ... 0 V 23 mA Approx. 12.5 V < 500 Ω (at 20 mA) > 10 kΩ < 20 mVPP (at 500 Ω) < 20 mVPP (on 10 kOhm) 19.2 V DC ... 30 V DC < 21 mA (for 24 V DC) < 500 mW ≤ 0.25% ; ((50 K / ∆ Temp)+ 0.05)% < 0.02%/K < 200 ms 1.5 kV (50 Hz, 1 min.) -20°C ... 65°C PBT CE compliant X II 3 G Ex nA II T4 X UL 508 Recognized Class I, Div. 2, Groups A, B, C, D T5 GL EMC 2 D Order key MINI MCR-SL-PT100-UI-200 (Standard configuration as example) Measuring range [°C] Output Failure Factory calibration Failure information (depends on the output signal range): information 1) certificate Start End Measured value overrange Open circuit / 0 / 100 / OUT01 / A / NONE 0...20 mA 4...20 mA 0...10 V 0...20 mA 4...20 mA 0...10 V 20.5 mA 10.25 V 21 mA 21 mA 10.5 V 0 Area OUT01 = 0...20 mA A NONE = Without certificate A 20.5 mA B 20.5 mA 20.5 mA 10.25 V 21 mA 21 mA 10.5 V 2864309 = -5 (width of step) OUT02 = 4...20 mA B YES = With factory C 20 mA 20 mA 10 V 21 mA 21 mA 10.5 V calibration ...-PT100-UI-200 3 = 3-wire -10 OUT03 = 0...10 V C D 20 mA 20 mA 10 V 0 mA 4 mA 0V certificate (fee) -15 0...200 (5 K) OUT05 = 0...5 V D Measured value underrange Short circuit 2864192 = 4 = 4-wire -20 OUT06 = 1...5 V YESPLUS = Factory calibra0...20 mA 4...20 mA 0...10 V 0...20 mA 4...20 mA 0...10 V tion certificate ...-PT100-UI-200-SP -30 OUT07 = 20...0 mA with 5 measuring A -40 OUT08 = 20...4 mA 0 mA 4 mA 0V 0 mA 4 mA 0V B 0 mA 3.5 mA 0V 0 mA 3 mA 0V points (fee) -50 OUT09 = 10...0 V C 0 mA 4 mA 0V 21 mA 21 mA 10.5 V 1) For explanations see adjacent text on the right, for further details see data sheet: www.phoenixcontact.com D 0 mA 4 mA 0V 0 mA 4 mA 0V Order No. 2864309 Connection method / 3 2 = 2-wire Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com PHOENIX CONTACT 339 INTERFACE Analog MINI Analog Configurable temperature transducer for Pt 100 6,2 102,5 Temperature 93,1 IN U,I OUT PT100 MINI MCR-SL-PT100-UI POWER SL Configurable temperature transducer for Pt 100 temperature sensors for measuring ranges of -150°C ... 850°C uF Ex: X U Housing width 6.2 The MINI MCR-SL-PT100-UI temperature transducers convert the measured values of Pt 100 sensors (IEC 60751/EN 60751) into analog standard signals. These temperature transducers are optimized for measuring ranges of -150 to 850°C. 2, 3 and 4-conductor Pt 100 sensors can be connected to the input. The DIP switches are accessible at the side of the housing and allow the following parameters to be configured: Connection method, temperature span to be measured, output signal, and type of error evaluation. The desired configuration must be specified when ordering pre-configured modules (refer to the order key). If specifications are incorrect or missing, the devices will be supplied with the standard configuration. Accessories: Information about components for energy bridging, system cabling and marking is given from page 347. 1 2 3 Screw connection Spring-cage conn. stranded [mm2] AWG 0.14-2.5 0.2-2.5 26-12 0.2-2.5 0.2-2.5 24-12 Screw M3 Description 2 Wire Pt 100 solid 4 Wire Pt 100 Measuring ranges from –150°C to 850°C 2, 3 or 4-conductor Pt 100 sensors Configurable output signals 3-way isolation Diagnostics LED and fault evaluation Power supply possible through the foot element (T-Connector) 3 Wire Pt 100 – – – – – – Iref A D 5 OUT UI 6 GND1 mC 4 DC DC DC 7 UB+ 8 GND2 ME 6,2 TBUS-... Type Order No. MINI MCR-SL-PT100-UI MINI MCR-SL-PT100-UI-SP MINI MCR-SL-PT100-UI-NC MINI MCR-SL-PT100-UI-SP-NC 2864435 2864736 2864273 2864286 Pcs. / Pkt. MCR temperature transducer, for PT100 temperature sensors Order configuration Order configuration Unconfigured Unconfigured Screw connection Spring-cage conn. Screw connection Spring-cage conn. Technical data Input data Input signal (configurable via DIP switch) Temperature range Measuring range span Output data Output signal (configurable via DIP switch) 1 1 1 1 Pt 100 (IEC 60751/EN 60751) : 2, 3, 4-wire -150°C ... 850°C (configurable) Min. 50 K I output U output 0 ... 20 mA / 4 ... 20 mA 0 ... 5 V / 1 ... 5 V 20 ... 0 mA / 20 ... 4 mA 0 ... 10 V / 10 ... 0 V 23 mA Approx. 12.5 V < 500 Ω (at 20 mA) ≥ 10 kΩ < 20 mVPP (at 500 Ω) < 20 mVPP (on 10 kOhm) Maximum output signal Load RB Ripple General data Supply voltage UB Current consumption Power consumption Transmission error for the full/set measurement range Temperature coefficient Step response (10-90%) Test voltage, input/output/supply Ambient temperature (operation) Housing material Conformance / approvals Conformity ATEX UL, USA / Canada 19.2 V DC ... 30 V DC < 21 mA (for 24 V DC) < 500 mW ≤ 0,2% ; ((100 K / set measurement range [K]) + 0.1)% < 0.02%/K < 160 ms 1.5 kV (50 Hz, 1 min.) -20°C ... 65°C PBT CE compliant X II 3 G Ex nA II T4 X UL 508 Recognized Class I, Div. 2, Groups A, B, C, D T5 GL EMC 2 D GL Order key MINI MCR-SL-PT100-UI (Standard configuration entered as example) Order No. 2864435 2864435 = ...-PT100-UI Connection method / 3 2 = 2-wire 3 = 3-wire 2864736 = 4 = 4-wire ...-PT100-UI-SP 1) Measuring range [°C] Output Failure Factory calibration information 1) certificate Start End / 0 / 100 / OUT01 / A / NONE 0 Area OUT01 = 0...20 mA A NONE = Without certificate -10 (width of step) OUT02 = 4...20 mA B YES = With factory calibration -20 OUT03 = 0...10 V C certificate (fee) -30 0...100 (5 K) OUT05 = 0...5 V D -40 110...300 ±10 K OUT06 = 1...5 V YESPLUS = Factory calibration certificate -50 320...700 (20 K) OUT07 = 20...0 mA with 5 measuring -100 750...850 (50 K) OUT08 = 20...4 mA points (fee) -150 OUT09 = 10...0 V For explanations see adjacent text on the right, for further details see data sheet: www.phoenixcontact.com 340 PHOENIX CONTACT Failure information (depends on the output signal range): Measured value overrange Open circuit 0...20 mA 4...20 mA 0...10 V 0...20 mA 4...20 mA 0...10 V A 20.5 mA 20.5 mA 10.25 V 21 mA 21 mA 10.5 V B 20.5 mA 20.5 mA 10.25 V 21 mA 21 mA 10.5 V C 20 mA 20 mA 10 V 21 mA 21 mA 10.5 V D 20 mA 20 mA 10 V 0 mA 4 mA 0V A B C D Measured value underrange 0...20 mA 4...20 mA 0...10 V 0 mA 4 mA 0V 0 mA 3.5 mA 0V 0 mA 4 mA 0V 0 mA 4 mA 0V Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com Short circuit 0...20 mA 4...20 mA 0...10 V 0 mA 4 mA 0V 0 mA 3 mA 0V 21 mA 21 mA 10.5 V 0 mA 4 mA 0V INTERFACE Analog MINI Analog Configurable loop-powered temperature transducer for Pt 100 IN I PT100 POWER 6,2 102,5 Temperature 93,1 OUT MINI MCR-SL-PT100-LP SL Configurable loop-powered temperature transducer for Pt 100 temperature sensors for measuring ranges of -150...300°C u Housing width 6.2 The MINI MCR-SL-PT100-UI-LP loop-powered temperature transducers convert the measured values of Pt 100 sensors (IEC 60751/EN 60751) into analog standard signals. These temperature transducers are optimized for measuring ranges of -150 to 300°C. 2, 3 and 4-conductor Pt 100 sensors can be connected to the input. On the output side, the module is operated in a 4...20 mA current loop, which simultaneously provides the power supply needed for signal conversion. The DIP switches are accessible at the side of the housing and allow the following parameters to be configured: Connection method, temperature span to be measured, output signal, and type of error evaluation. The desired configuration must be specified when ordering pre-configured modules (refer to the order key). If specifications are incorrect or missing, the devices will be supplied with the standard configuration. I 2 Screw M3 2 Wire Pt 100 Screw connection Spring-cage conn. stranded [mm2] AWG 0.14-2.5 0.2-2.5 26-12 0.2-2.5 0.2-2.5 24-12 3 solid URef U 1 4 Wire Pt 100 No separate voltage supply Measuring ranges from –150°C to 300°C 2, 3 or 4-conductor Pt 100 sensors Configurable output signals 2-way isolation Diagnostics LED and fault evaluation 3 Wire Pt 100 – – – – – – Applied for: UL-EX LIS / CUL-EX LIS J D 5 OUT I 6 GND 1 mC 4 DC DC 7 NC 8 NC Description Type Order No. MCR temperature transducer, for Pt 100 temperature sensors, loop-powered Order configuration Screw connection Order configuration Spring-cage conn. Unconfigured Screw connection Unconfigured Spring-cage conn. MINI MCR-SL-PT100-LP MINI MCR-SL-PT100-LP-SP MINI MCR-SL-PT100-LP-NC MINI MCR-SL-PT100-LP-NC-SP 2810298 2810382 2810308 2810395 Technical data Input data Input signal (configurable via DIP switch) Temperature range Measuring range span Output data Output signal Maximum output signal Load RB Ripple General data Supply voltage UB Current consumption Power consumption Transmission error for the full/set measurement range Temperature coefficient Step response (10-90%) Test voltage, input/output/supply Degree of protection Ambient temperature (operation) Assembly Housing material Conformance / approvals Conformity ATEX UL, USA / Canada Pcs. / Pkt. 1 1 1 1 Pt 100 (IEC 60751/EN 60751) : 2, 3, 4-wire -150°C ... 300°C (configurable) Min. 50 K 4 ... 20 mA / 20 ... 4 mA 23 mA (output limit) ((Usupply - 12 V) / 22 mA) < 20 mVPP (at 500 Ω) 12 V DC ... 30 V DC < 3.5 mA (without signal current) < 42 mW (without signal current) ≤ 0.25% ; ((90 K / set measuring range [K]) + 0.05)% < 0.02%/K < 200 ms 1.5 kV (50 Hz, 1 min.) IP20 -20°C ... 65°C Any PBT CE compliant X II 3 G Ex nA II T4 X UL 508 Recognized Class I, Div. 2, Groups A, B, C, D T5 applied for Order key MINI MCR-SL-PT100-LP (Standard configuration entered as example) Order No. 2810298 2810298 = ...-PT100-LP 2810382 = ...-PT100-LP-SP 1) Connection method / 3 2 = 2-wire 3 = 3-wire 4 = 4-wire Measuring range [°C] Output Failure Factory calibration information 1) certificate Start End / 0 / 100 / OUT02 / 1 / NONE 0 Area NONE = Without certificate -10 (width of step) OUT02 = 4...20 mA 1 YES = With factory calibration -20 OUT08 = 20...4 mA 2 certificate (fee) -30 0...300 (5 K) 3 -40 4 YESPLUS = Factory calibration certificate with -50 5 measuring -100 points (fee) -150 For explanations see adjacent text on the right, for further details see data sheet: www.phoenixcontact.com Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com Failure information: Measured value overrange 1 2 21.5 mA 3 3.5 mA 4 21.5 mA 1 2 3 4 Measured value underrange 21.5 mA 3.5 mA 3.5 mA Open circuit Measuring range start 21.5 mA 3.5 mA 21.5 mA Short circuit Measuring range start 21.5 mA 3.5 mA 3.5 mA PHOENIX CONTACT 341 INTERFACE Analog MINI Analog Configurable temperature transducer for Type J and K thermocouples 6,2 102,5 Temperature 93,1 IN U,I OUT MINI MCR-SL-TC-UI POWER SL Configurable temperature transducer for thermocouples for measuring ranges of -150...1350°C uF Ex: X U Housing width 6.2 URef – – – – – Measuring ranges from –150°C to 1350°C Configurable output signals 3-way isolation Diagnostics LED and fault evaluation Power supply possible through the foot element (T-Connector) TC J D 5 OUT UI 6 GND1 mC solid Screw connection stranded [mm2] AWG 0.14-2.5 0.2-2.5 26-12 2 3 DC DC Screw M3 CJC DC 7 UB + 8 GND2 ME 6,2 TBUS-... The MINI MCR-SL-TC-UI temperature transducers convert the measured values of thermocouple sensors (IEC 60584-1/ EN 60584-1) of types J and K into analog standard signals. Both type J and type K thermocouples can be connected at the input. The DIP switches are accessible at the side of the housing and allow the following parameters to be configured: Connection method, temperature span to be measured, output signal, and type of error evaluation. The desired configuration must be specified when ordering pre-configured modules (refer to the order key). If specifications are incorrect or missing, the devices will be supplied with the standard configuration. Accessories: Information about components for energy bridging, system cabling and marking is given from page 347. Description Order configuration Unconfigured Screw connection Screw connection Technical data Input data Input signal (configurable via DIP switch) Temperature range Maximum output signal No-load voltage Short-circuit current Load RB Ripple General data Supply voltage UB Power consumption Transmission error for the full/set measurement range Cold point errors Temperature coefficient Step response (10-90%) Test voltage, input/output/supply Ambient temperature (operation) Housing material Conformance / approvals Conformity ATEX UL, USA / Canada Measuring range [°C] Output Failure Factory calibration information 1) certificate Start End / 3 / 0 / 1000 / OUT01 / A / NONE J = Type J 0 Area OUT01 = 0...20 mA A NONE = Without certificate -10 (width of step) OUT02 = 4...20 mA B YES = With factory calibration K = Type K -20 OUT03 = 0...10 V C certificate (fee) -30 OUT05 = 0...5 V D -40 0...300 ±10 K OUT06 = 1...5 V YESPLUS = Factory calibration certificate -50 320...700 (20 K) OUT07 = 20...0 mA with 5 measuring -100 750...1350 (50 K) OUT08 = 20...4 mA points (fee) -150 OUT09 = 10...0 V For explanations see adjacent text on the right, for further details see data sheet: www.phoenixcontact.com 342 PHOENIX CONTACT MINI MCR-SL-TC-UI MINI MCR-SL-TC-UI-NC 2864448 2864299 Pcs. / Pkt. 1 1 Thermocouples type J, K (IEC 584-1) Typ J : -150°C ... 1200°C (configurable) Typ K : -150°C ... 1350°C Min. 50 K I output U output 0 ... 20 mA / 4 ... 20 mA 0 ... 5 V / 1 ... 5 V 20 ... 0 mA / 20 ... 4 mA 0 ... 10 V / 10 ... 0 V 23 mA Approx. 12.5 V Approx. 12.5 V Approx. 10 mA < 500 Ω (at 20 mA) ≥ 10 kΩ < 20 mVPP (at 500 Ω) < 20 mVPP (on 10 kOhm) Measuring range span Output data Output signal (configurable via DIP switch) Sensor type 1) Order No. MCR temperature transducer, for thermocouples 19.2 V DC ... 30 V DC < 500 mW ≤ 0,2% ; ((150 K / set measurement range [K]) + 0.1)% < 3 K ( Typ. < 2 K ) < 0.02%/K < 30 ms 1.5 kV (50 Hz, 1 min.) -20°C ... 65°C PBT CE compliant X II 3 G Ex nA II T4 X UL 508 Recognized Class I, Div. 2, Groups A, B, C, D T5 GL EMC 2 D GL Order key MINI MCR-SL-TC-UI (Standard configuration entered as example) Order No. 2864448 Type Failure information (depends on the output signal range): Measured value overrange Open circuit 0...20 mA 4...20 mA 0...10 V 0...20 mA 4...20 mA 0...10 V A 20.5 mA 20.5 mA 10.25 V 21 mA 21 mA 10.5 V B 20.5 mA 20.5 mA 10.25 V 21 mA 21 mA 10.5 V C 20 mA 20 mA 10 V 21 mA 21 mA 10.5 V D 20 mA 20 mA 10 V 0 mA 4 mA 0V A B C D Measured value underrange 0...20 mA 4...20 mA 0...10 V 0 mA 4 mA 0V 0 mA 3.5 mA 0V 0 mA 4 mA 0V 0 mA 4 mA 0V Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com INTERFACE Analog MINI Analog Configurable analog frequency transducer 93,1 Conversion 102,5 6,2 IN U,I f OUT MINI MCR-SL-UI-F POWER SL Configurable analog frequency transducer uF Ex: X // Applied for: UL-EX LIS / CUL-EX LIS Housing width 6.2 URef – Conversion from analog to frequency and PWM signals – Adjustable interference filter – Configurable input and output signals – Diagnostics LED and fault evaluation – 3-way isolation – Power supply possible through the foot element (T-Connector) The MINI MCR-SL-UI-F analog frequency transducers are used to convert analog standard signals to frequency signals. These can then be further processed with the digital input of a controller. The standard analog signals can also be converted to pulse width modulated (PWM) signals (5-95%). A filter can be set to smooth interference on the input signal. DIP switches on the side of the housing allow the following parameters to be set: input signal, output signal, behavior of the signal in the event of measuring overrange or underrange, type of filter. Accessories: Information about components for energy bridging, system cabling and marking is given from page 347. Frequency output T T T T T T Variable frequency / Period duration T IN UI 1 GND 1 2 D 5 OUT + 6 GND - mC solid Screw connection Spring-cage conn. stranded [mm2] AWG 0.14-2.5 0.2-2.5 26-12 0.2-2.5 0.2-2.5 24-12 A DC DC Screw M3 DC UB+ 3 GND 2 4 7 UB+ 8 GND2 ME 6,2 TBUS-... Description Type Order No. MINI MCR-SL-UI-F MINI MCR-SL-UI-F-SP 2864082 2810243 Pcs. / Pkt. MCR frequency transducer Screw connection Spring-cage conn. Technical data Input data Input signal (configurable via DIP switch) Maximum permissible input level Input resistance Behavior in the event of an error Output data Output signal (configurable via DIP switch) Minimum load Load current maximum Maximum switching voltage Overrange/underrange Protective circuitry General data Supply voltage UB Nominal supply voltage Current consumption Power consumption Transmission error, max. Temperature coefficient Step response (10-90%) Test voltage, input/output/supply Degree of protection Ambient temperature (operation) Assembly Housing material Conformance / approvals Conformity ATEX UL, USA / Canada GL 1 1 I input U input 0 ... 20 mA / 4 ... 20 mA 0 ... 5 V / 1 ... 5 V 0 ... 10 mA / 2 ... 10 mA 0 ... 10 V / 2 ... 10 V 100 mA 30 V DC Approx. 50 Ω Approx. 110 kΩ Alarm in the form of a LED red Frequency output PWM output 0 Hz ... 10 kHz / 0 Hz ... 5 kHz 7.8 kHz (10 bit) / 3.9 kHz (10 bit) 0 Hz ... 2.5 kHz / 0 Hz ... 1 kHz 1.9 kHz (12 bit) / 977 Hz (12 bit) 0 Hz ... 500 Hz / 0 Hz ... 250 Hz 488 Hz (14 bit) / 244 Hz (14 bit) 0 Hz ... 100 Hz / 0 Hz ... 50 Hz 122 Hz (16 bit) / 61 Hz (16 bit) 6000 Ω 2000 Ω 20 mA 30 V Can be set (via DIP switch) Short circuit protection, polarity reversal protection 19.2 V DC ... 30 V DC 24 V DC < 10 mA (for 24 V DC) < 200 mW < 0.1% < 0.02%/K < 15 ms / < 1 s (with the largest filter) 1.5 kV (50 Hz, 1 min.) IP20 -20°C ... 65°C Any PBT CE compliant X II 3 G Ex nA II T4 X UL 508 Recognized Class I, Div. 2, Groups A, B, C, D T5 applied for GL EMC 2 D PWM output (pulse width modulation) T T T T T T Variable pulse-pause ratio / Fixed period duration T Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com PHOENIX CONTACT 343 INTERFACE Analog MINI Analog Configurable potiposition transducer 93,1 Conversion 102,5 6,2 IN R U,I OUT MINI MCR-SL-R-UI POWER SL Configurable potiposition transducer uF Ex: X // Applied for: UL-EX LIS / CUL-EX LIS Housing width 6.2 – For potentiometers from 100 Ω to 100 kΩ – Automatic potentiometer detection – Configurable measuring range and output signals – "Teach in" function for limit values – Signaling the measurement overrange and underrange – 3-way isolation – Power supply possible through the foot element (T-Connector) 1 2 3 DC DC 4 DC solid Screw connection Spring-cage conn. stranded [mm2] AWG 0.14-2.5 0.2-2.5 26-12 0.2-2.5 0.2-2.5 24-12 Screw M3 5 OUT UI 6 GND1 mC 7 UB+ 8 GND2 ME 6,2 TBUS-... Description Type Order No. MINI MCR-SL-R-UI MINI MCR-SL-R-UI-SP 2864095 2810256 Pcs. / Pkt. MCR potiposition transducer The MINI MCR-SL-R-UI potentiometer measuring transducers convert potentiometer positions into an analog standard signal. The devices can be used for potentiometers with a resistance value of 0...100 Ω to 0...100 kΩ. If the potentiometer range cannot be utilized to the full for technical reasons, externally accessible trimmers/switches provide for simple and precise compensation of the analog signal. An additional LED lights up if the measuring range is exceeded or fallen below. Accessories: Information about components for energy bridging, system cabling and marking is given from page 347. Lifting platform M ACTUAL SETPOINT 0...10V 0...10V Actuator motor Potentiometer Screw connection Spring-cage conn. Technical data Input data Potentiometer Reference voltage source Output data Output signal Maximum output signal No-load voltage Short-circuit current Load RB Ripple Behavior in the event of a sensor error General data Supply voltage UB Nominal supply voltage Current consumption Power consumption Transmission error, max. Temperature coefficient Step response (10-90%) Test voltage, input/output/supply Degree of protection Ambient temperature (operation) Assembly Housing material Conformance / approvals Conformity ATEX UL, USA / Canada GL 100 Ω ... 100 kΩ < 3.6 V U output 0 ... 5 V / 1 ... 5 V 0 ... 10 V / 10 ... 0 V 12.5 V Approx. 10 mA > 10 kΩ < 20 mVPP (on 10 kOhm) Configurable 0% ... 105% OUT 1 CE compliant X II 3 G Ex nA II T4 X UL 508 Recognized Class I, Div. 2, Groups A, B, C, D T5 applied for GL EMC 2 D 5 GND1 Control system 6 UB + 3 GND2 4 MINI MCR-SL-R-UI 7 8 24V Mains voltage Height adjustment of a lifting platform with setpoint and actual value control 344 PHOENIX CONTACT < 500 Ω (20 mA) < 20 mVPP (at 500 Ω) 19.2 V DC ... 30 V DC 24 V DC < 25 mA (for 24 V DC) < 500 mW < 0.2% < 0.02%/K < 30 ms 1.5 kV (50 Hz, 1 min.) IP20 -20°C ... 65°C Any PBT Controller 2 I output 0 ... 20 mA / 4 ... 20 mA 20 ... 0 mA / 20 ... 4 mA 23 mA Approx. 12.5 V Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com 1 1 INTERFACE Analog MINI Analog Configurable NAMUR switching amplifier 93,1 Control 102,5 6,2 IN OUT MINI MCR-SL-NAM-2RNO SL POWER Configurable NAMUR switching amplifier uF Housing width 6.2 IN – For operating proximity sensors, floating switching contacts and switching contacts with resistance circuit – Configurable N/O contacts – 3-way isolation – Power supply possible through the foot element (T-Connector) The MINI MCR-SL-NAM-2RNO isolation amplifiers condition, isolate and duplicate signals from proximity sensors in acc. with IEC 60947-5-6, EN 50227. It is also possible to connect floating switching contacts or switching contacts with resistance circuit. The isolation amplifiers detect line faults on the input side and switch the outputs to a deenergized state when an error is detected. If the second N/O contact is used as an alarm output, the relay is activated when an error is detected. The DIP switches are accessible at the side of the housing and allow the following parameters to be configured: – Second N/O contact can be used to duplicate signals or as an alarm output – Line fault detection can be deactivated (necessary when switching contacts are connected) – Switchover between operating current and quiescent current (inverted switching behavior) Accessories: Information about components for energy bridging, system cabling and marking is given from page 347. Ex: X // Applied for: UL-EX LIS / CUL-EX LIS + 1 - 2 5 13 OUT1 6 14 DC DC DC solid Screw connection Spring-cage conn. stranded [mm2] AWG 0.14-2.5 0.2-2.5 26-12 0.2-2.5 0.2-2.5 24-12 Screw M3 13 3 OUT2 14 4 7 UB+ 8 GND ME 6,2 TBUS-... Description Type Order No. MINI MCR-SL-NAM-2RNO MINI MCR-SL-NAM-2RNO-SP 2864105 2810269 Pcs. / Pkt. MCR NAMUR switching amplifier Screw connection Spring-cage conn. Technical data Input data Input signal Control circuit No-load voltage Switching points (in acc. with IEC 60947-5-6) Line error detection Switching output Relay output Contact material Max. switching voltage Max. switching current Min. contact current Switching frequency General data Supply voltage UB Nominal supply voltage Current consumption Power consumption Test voltage, input/output/supply Degree of protection Ambient temperature (operation) Assembly Housing material Conformance / approvals Conformity ATEX UL, USA / Canada GL 1 1 NAMUR proximity sensors Floating switching contacts Switching contacts with resistance circuit 8.2 V DC ±10% < 1.2 mA (disabling) > 2.1 mA (conducting) > 6 mA (in the event of a short circuit) < 0.1 mA (with wire break) 2 N/O contacts AgSnO2, hard gold-plated 250 V AC 2A 1 mA (for 5 V DC) 10 Hz 19.2 V DC ... 30 V DC 24 V DC < 25 mA < 600 mW 1.5 kV (50 Hz, 1 min.) IP20 -20°C ... 60°C Any PBT CE compliant X II 3 G Ex nAC IIC T4 X UL 508 Recognized Class I, Div. 2, Groups A, B, C, D T5 applied for GL EMC 2 D Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com PHOENIX CONTACT 345 INTERFACE Analog MINI Analog Configurable threshold value switch 93,1 Control 102,5 6,2 IN U,I OUT MINI MCR-SL-UI-REL SL POWER Threshold value switch with relay output uF Ex: X U Housing width 6.2 – 3-way isolation – Adjustable limit values, hysteresis and delay time – Operating current / Quiescent current switchover – Power supply possible through the foot element (T-Connector) The MINI MCR-SL-UI-REL threshold value switches are used for monitoring standard signals. The devices that can be adjusted via DIP switches and potentiometers are electrically isolated from each other in the input, output and supply circuit. The limit value of the analog input signal 0...10 V or 0(4)...20 mA can be preselected with a DIP switch and accurately set via a potentiometer. If the input signal reaches the limit value, a PDT relay contact is actuated at the output. If necessary, a DIP switch can be used to switch a hysteresis around the limit value. The response behavior of the PDT relay can also be set via a DIP switch using the operating current or quiescent current principle. Two LEDs signal the relay status (yellow) and alarm (red). Accessories: Information about components for energy bridging, system cabling and marking is given from page 347. 346 PHOENIX CONTACT IN UI 5 GND1 6 1 2 3 4 mC D solid Screw connection Spring-cage conn. stranded [mm2] AWG 0.14-2.5 0.2-2.5 26-12 0.2-2.5 0.2-2.5 24-12 A N.C. 14 11 12 DC Screw M3 DC 7 UB + 8 GND2 ME 6,2 TBUS-... Description Type Order No. MINI MCR-SL-UI-REL MINI MCR-SL-UI-REL-SP 2864480 2864493 Pcs. / Pkt. MCR threshold value switch Screw connection Spring-cage conn. Technical data Input data Input signal (configurable via DIP switch) Maximum permissible input level Input resistance Specification of the switching point Switching output Relay output Contact material Max. switching voltage Limiting continuous current Hysteresis (configurable using the DIP switch) Operating and closed circuit current behavior Setting range of the response delay (configurable using the DIP switch) General data Supply voltage UB Nominal supply voltage Current consumption Power consumption Linearity error Temperature coefficient Step response (10-90%) Test voltage input/power supply Degree of protection Ambient temperature (operation) Assembly Housing material Conformance / approvals Conformity ATEX UL, USA / Canada UL, USA UL, Canada GL I input 0 ... 20 mA 100 mA 50 Ω With 25-speed potentiometer U input 0 ... 10 V 30 V > 100 kΩ 1 PDT AgSnO2, hard gold-plated 250 V AC 2A (0.1%; 1%; 2.5%; 5%) Switchable using DIP switch 0 s ... 10 s (0 s; 1 s; 2 s; 3 s; 4 s; 6 s; 8 s; 10 s) 19.2 V DC ... 30 V DC 24 V DC < 14 mA (for 24 V DC) < 330 mW (for 24 V DC) < 0.05% (of end value) < 0.02%/K < 35 ms 1.5 kV AC (50 Hz, 1 min.) IP20 -20°C ... 65°C Any PBT CE compliant X II 3 G Ex nAC IIC T4 X UL 508 Recognized Class I, Zone 2, AEx nC IIC T6 Class I, Zone 2, Ex nC IIC T6 GL EMC 2 D Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com 1 1 INTERFACE Analog MINI Analog Accessories Feed-through terminal blocks The 6.2 mm wide MINI MCR-SL-TB feed-through terminal block helps in 1:1 forwarding of signals in the MINI Analog unit. The inner structure consists of a simple direct connection without conversion or electrical isolation of the generated signals. The feed-through terminal block can be used in the standard unit as well as as an addition for the system cabling. For example, if a system cabling is desired and only seven signals are present, the gap can be cost-effectively filled using a feedthrough terminal block. For more information about how you can make use of the numerous advantages of the system cabling, see page 350. solid Screw connection stranded [mm2] AWG 0.14-2.5 0.2-2.5 24-12 Screw M3 MINI MCR-SL-TB Description Type Order No. MINI MCR-SL-TB 2811420 Pcs. / Pkt. MCR feed-through terminal block Technical data General data Degree of protection Ambient temperature (operation) Assembly Housing material 1 IP20 -20°C ... 65°C Any PBT Accessories Marking material MINI MCR DKL and MINI MCRDKL-LABEL allow flexible labeling of MINI Analog modules. The hinged transparent cover is snapped onto the module and a stamped insert strip is pushed into the side of the cover. Moreover, labeling is possible with the flat Zack marker strip ZBF 6 marker labels. MINI MCR DKL Description Type Order No. Pcs. / Pkt. Fold up transparent cover, for labeling MINI Analog modules with insert strips Insert strips, stamped, for transparent cover MINI MCR DKL 2308111 10 MINI MCR-DKL-LABEL 2810272 10 Flat-ribbon labeling (see CLIPLINE catalog) ZBF 6... Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com PHOENIX CONTACT 347 INTERFACE Analog MINI Analog Accessories Power terminals – Redundant supply possible – For up to 80 MINI analog modules – With signal LED The MINI MCR-SL-PTB power terminal with the same shape allows redundant supply of the supply voltage through the foot element (T-connector). The diode-decoupled redundant infeed increases the system availability. The power terminal is snapped conveniently onto the foot element and can thus supply up to 80 MINI analog modules. The current carrying capacity of the power terminal is 2 A. A green power LED signals the applied supply voltage. A LED red at each input signals a supply voltage applied with reverse polarity on the power terminal. Recommended fuse for power terminal: Fuse in acc. with IEC 60127-2/V Nominal current: 2.5 A Characteristics: Slow-blow (e.g. Wickmann 5 x 20 mm/No. 195 - glass fuse) solid Screw connection Spring-cage conn. stranded [mm2] AWG 0.14-2.5 0.2-2.5 26-12 0.2-2.5 0.2-2.5 24-12 Screw M3 MINI MCR-SL-PTB Description MCR power terminal Screw connection Spring-cage conn. Technical data Input data Input voltage range Current consumption Output data Output voltage Output current General data Degree of protection Ambient temperature (operation) Assembly Housing material Conformance / approvals Conformity ATEX UL, USA / Canada GL Type Order No. MINI MCR-SL-PTB MINI MCR-SL-PTB-SP 2864134 2864147 Pcs. / Pkt. 1 1 0 V DC ... 30 V DC Max. 2 A (Input voltage - 0.8 V) 2A IP20 -20°C ... 65°C Any PBT CE compliant X II 3 G Ex nA II T4 X UL 508 Recognized GL EMC 2 D Accessories DIN rail connector The T-connector ME 6,2 TBUS-... serves to bridge the supply voltage. MINI Analog modules can thus be connected quickly and with less wiring. This makes module replacement during the process less complicated. The T-connectors can be extended between each other and can be snapped onto 35 mm DIN rails acc. to EN 60715. A T-connector supplies power to two MINI Analog modules each. The maximum current carrying capacity is 8 A transverse (parallel to the DIN rail when using the system current supply) as well as 2 A to the MINI Analog module (even when using the power terminal). 348 PHOENIX CONTACT ME 6,2 TBUS-2... Description Type Order No. Pcs. / Pkt. DIN rail connector (T bus), for bridging the supply voltage, can be snapped onto 35 mm DIN rails as per EN 60715, with UL approval ME 6,2 TBUS-2 1,5/5-ST-3,81 GN 2869728 10 Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com INTERFACE Analog MINI Analog Accessories System power supply MINI SYS POWER The DIN rail connector of the system power supply allows additional modules of the same system to be supplied with a regulated 24 V DC voltage. The low height of just 102.5 mm allows installation in flat control cabinets. MINI POWER EX Power compact for the decentral automation. The power supply unit complies with standard EN 60079-15 and may be installed within the potentially explosive area in which category 3G items are necessary. MINI 24 V DC/1.5 A(/EX) Pcs. / Pkt. Description Type Order No. System power supply unit, primary-switched with zone 2 approval. More information is given in the INTERFACE Power Supply catalog part. System power supply unit, primary-switched (not for zone 2) More information is given in the INTERFACE Power Supply catalog part. MINI-PS-100-240AC/24DC/1.5/EX 2866653 1 MINI-SYS-PS-100-240AC/24DC/1.5 2866983 1 Accessories DIN rail connector The T-connector ME 17,5 TBUS-... serves to bridge the supply voltage when using a MINI POWER system power supply unit. If the system power supply unit is used, two T-connectors ME 17,5 TBUS are required to establish a connection to the T-connectors ME 6,2 TBUS of the MINI Analog unit and to supply them effectively with power. ME 17,5 TBUS 1,5/ 5-ST-3,81 GN Description Type Order No. Pcs. / Pkt. DIN rail connector, for bridging the supply voltage, can be snapped onto 35 mm DIN rails as per EN 60715, with UL approval, two pieces are required per system power supply ME 17,5 TBUS 1,5/ 5-ST-3,81 GN 2709561 10 Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com PHOENIX CONTACT 349 INTERFACE Analog MINI Analog Accessories System cabling In many applications, analog signal transmission on 6 mm means a high number of channels in confined spaces. Error-free, time-efficient and cost-saving wiring solutions therefore have utmost significance in this regard. The MINI Analog system cabling enables quick, easy and error-free wiring of up to eight channels. System cabling can be implemented using different methods. System cabling with front adapters This includes: – 16-pos. FLK cable – The V8 system adapter for MINI Analog modules – One front adapter that must be specifically selected for the analog card of the control system In this solution, the components simply need to be plugged together. There is virtually no further wiring cost. In addition, it is no longer possible to make mistakes in wiring since the pre-assembled components already have the correct assignment. System cabling without front adapters This ideal substitute is the version that does not use a front adapter. A 16-pos. FLK cable with open ends on one side is used in this case. The open ends are provided with ferrules and numbers. As a result, you can connect this system cable to almost every module that is not equipped with a front adapter. It is advantageous owing to the fast, quick and error-free system cabling on the module side. V8 system adapter for MINI Analog 16-pos. FLK cable Front adapter for analog card System cabling with front adapters Project planning help is given in the following table. Please visit our website or contact us to get information regarding other solutions. Project planning help for MINI Analog system cabling Control system Analog card Front adapter Siemens SIMATIC S7-300 / ET 200 M 6ES7-331-7KF02-0AB0 6ES7-331-7KB02-0AB0 6ES7-331-7KB81-0AB0 6ES7-331-7TF00-0AB0 6ES7-332-8TF01-0AB0 FLKM 16-PA-S300/MINI-MCR (On page 210 in the catalog) 6ES7-331-1KF01-0AB0 (For current signals) FLKM 16-PA-331-1KF/I/MINI-MCR (On page 211 in the catalog) 6ES7-331-5HF00-0AB0 (For current signals) FLKM 16-PA-332-5HF/I/MINI-MCR (On page 211 in the catalog) Yokogawa Centum CS 3000 R3 AAI 141 Not required AAI 143 FLK cable V8 system adapter for MINI Analog FLK 16/EZ-DR/.../KONFEK (Non-molded connector, on page 264 in the catalog) MINI MCR-SL-V8-FLK 16-A (On page 352 in the catalog) CABLE-40/2/FLK16/.../YUC (Non-molded connector, on page 223 in the catalog) 2 x MINI MCR-SL-V8-FLK 16-A (On page 352 in the catalog) CABLE-FLK16/OE/0,14/...M (Non-molded connector, on page 260 in the catalog) Other control systems / actuators / sensors All cards Not required or optionally VIP-CAB-FLK16/FR/OE/0,14/...M (Molded connector, on page 260 in the catalog) 350 PHOENIX CONTACT Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com MINI MCR-SL-V8-FLK 16-A (On page 352 in the catalog) INTERFACE Analog MINI Analog V8 system adapter for MINI Analog Pluggable connection 16-pos. VIP or FLK cable with open ends Innovative concept System cabling without front adapters Innovative concept The MINI MCR-SL-V8-FLK 16-A MINI Analog system adapter can be used on the input as well as output sides due to the innovative design concept. As a result, there is nothing preventing the system cabling of input and output modules using the same components. More protection The new VIP cables with molded FLK connectors provide increased protection in rough industrial environments. In the case of system cabling without front adapters, you have the option of using the advantages of the new VIP cable on the system adapter side. Complete flexibility The proven FLK selecting cables and series offers complete flexibility when selecting and is the ideal solution for system cabling with front adapters. The flat, stranded connector connections allow problem-free accommodation in any analog module. Supplement If system cabling with less than eight channels needs to be implemented, the MINI MCR-SL-TB feed-through terminal block (page 347) is the ideal substitute. Complete flexibility More protection Supplement Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com PHOENIX CONTACT 351 INTERFACE Analog MINI Analog Accessories MINI Analog system adapter Thanks to its new plug-in concept, the MINI Analog system adapter MINI MCRSL-V8 FLK 16-A provides a time-saving wiring solution. Eight MINI Analog signal converters are connected to a control unit easily by means of pluggable system cabling. Therefore, the cabling cost and the wiring error risk in applications with greater signal quantities are reduced considerably in comparison with the PLS-side singleconductor wiring. Universal "Plug and Play" solutions can be offered in connection with the INTERFACE cabling products. MINI MCR-SL-V8-FLK 16-A System adapter uF Ex: X // Applied for: UL-EX LIS / CUL-EX LIS Description Type Order No. MINI MCR-SL-V8-FLK 16-A 2811268 Pcs. / Pkt. System adapter, for MINI analog modules with screw connection Technical data Connection to the signal level Insertion/withdrawal cycles (System adapter / FLK 16 ) Contact resistance Current carrying capacity Test voltage Ambient temperature (operation) Vibration resistance Surge voltage category / Pollution degree Dimensions W / H / D Conformance / approvals ATEX UL, USA / Canada GL 352 PHOENIX CONTACT Flat-ribbon cable connector, 16-pos.(FLK 16) 10 / Min. 200 < 10 mΩ Max. 1 A 500 V (50 Hz, 1 min. from channel to channel) -20°C ... 60°C Max. 0.7 g III / 2 50.4 mm / 45.5 mm / 46.2 mm X II 3 G Ex nA II T4 X UL 508 Recognized Class I, Div. 2, Groups A, B, C, D T5 applied for GL EMC 2 D Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com 1 INTERFACE Analog MINI Analog YOKOGAWA Centum CS3000 R3 Motherboard for MINI Analog system cabling The MINI Analog motherboard UM1222KS40 enables effective connection of 16 MINI Analog modules to Yokogawa analog modules. Furthermore, a redundant feed, an alarm via a relay in the event of a power failure, and a redundant connection to two analog modules are possible. The motherboard is delivered with all components for assembly with MINI Analog modules. Only the isolation amplifiers required for the application must be selected and ordered. More motherboard solutions are available on the Internet. For the relevant system cables for connecting the motherboard to the analog modules, see page 223. H W D UM122-2KS40/16/MINI-MCR/UNI Motherboard for up to 16 MINI analog modules Description Type Order No. UM122-2KS40/16/MINI-MCR/UNI 2319210 Pcs. / Pkt. Motherboard, for MINI Analog system cabling Technical data General data Connection to the field level Connection to the control system level Supply voltage Protection against polarity reversal Operating voltage monitoring 1 Directly to MINI analog modules 40-pos. KS connectors 19.2 V DC ... 30 V DC Yes The failure of one of the two supplies is indicated by the respective LED green extinguishing and by the relay contact opening. Safety monitoring Fusing is indicated by a red illuminated LED and the relay contact opening. Ambient temperature range Housing material Dimensions W / H / D -20°C ... 55°C PVC 216 / 122 / 140 mm Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com PHOENIX CONTACT 353 INTERFACE Analog MINI Analog Accessories Surge protection LINETRAB LIT An ideal supplement to MINI Analog the innovative surge protection solution in a 6.2 mm housing. Owing to the uniform shape of the housings of LINETRAB LIT and MINI Analog, the numerous advantages of system cabling can be used. The combination of MINI Analog and LINETRAB LIT is advantageous for you since you get a space-saving, perfectly coordinated and protected signal chain from the sensor to the control system. Project planning help for the MINI Analog / LINETRAB combination options is given in the following tables. The components and the combination options for implementing system cabling between MINI Analog and LINETRAB are listed on the left side. Details regarding system cabling between MINI Analog and the control system side are given on page 350. Detailed information regarding LINETRAB LIT surge protection modules is given in the TRABTECH catalog. Assembled 16-pos. round cable VIP-CAB-FLK16/FR... V8 system adapter for MINI Analog LINETRAB LIT Surge protection modules Safe measurement using the LINETRAB LIT and MINI Analog system Project planning help for LINETRAB LIT - MINI Analog Cabling via MINI Analog system adapter (8 modules) LINETRAB LIT (surge protection) Type LIT 1X2-24 MINI Analog Order No. Type Order No. 2804610 MINI MCR-SL-UI-UI MINI MCR-SL-UI-UI-NC MINI MCR-SL-U-UI-NC MINI MCR-SL-U-I-0 MINI MCR-SL-U-I-4 MINI MCR-SL-I-U-0 MINI MCR-SL-I-U-4 MINI MCR-SL-I-I MINI MCR-SL-U-U MINI MCR-SL-UI-2I MINI MCR-SL-UI-2I-NC MINI MCR-SL-RPS-I-I MINI MCR-SL-RPSS-I-I MINI MCR-SL-1CP-I-I MINI MCR-SL-UI-F MINI MCR-SL-NAM-2RNO MINI MCR-SL-UI-REL MINI MCR-SL-SHUNT-UI MINI MCR-SL-SHUNT-UI-NC 2864383 2864150 2865007 2813512 2813525 2813541 2813538 2864406 2864684 2864794 2864176 2864422 2864079 2864419 2864082 2864105 2864480 2810858 2810780 Components required for system cabling Available 16-pos. VIP... round cable Type V8 system adapter for MINI Analog Length Order No. VIP-CAB-FLK16/FR/FR/0,14/0,5M 0.5 m 2900154 VIP-CAB-FLK16/FR/FR/0,14/1,0M 1.0 m 2900155 VIP-CAB-FLK16/FR/FR/0,14/2,0M 2.0 m 2900156 Special lengths of VIP... round cable are available on request. 354 PHOENIX CONTACT Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com Type 2 x MINI MCR-SL-V8-FLK 16-A (On page 352 in the catalog) INTERFACE Analog MINI Analog VIP system cable The new VIP cables offer safe and rugged connection in rough industrial environments as well. Innovative concept The MINI Analog system adapter offers the option of input and output-side system cabling. An error-free and quick cabling is also possible using LINETRAB surge protection modules. More protection In addition to the advantages of electrical isolation, filtering, amplification and conversion of analog standard signals using MINI Analog, it also offers effective surge protection. Surge protection Surge protection is effective and provides reliable protection against system damage and downtimes. LINETRAB limits transient surge voltages safely and without affecting the signals - and all that in a design width of just 6.2 mm! VIP system cable Innovative concept Project planning help for LINETRAB LIT - MINI Analog Manual cabling LINETRAB LIT (surge protection) Type LIT 1X2-24 More protection MINI Analog Order No. 2804610 LIT 2X2-24 2804623 LIT 2-12 (For 2-wire connection method) 2804665 LIT 4-12 (For 3 and 4-wire connection method) 2804678 LIT 1X2-24 2804610 LIT 4-24 2804678 Type Order No. MINI MCR-SL-UI-UI MINI MCR-SL-UI-UI-NC MINI MCR-SL-UI-UI-SP MINI MCR-SL-UI-UI-SP-NC MINI MCR-SL-SHUNT-UI-SP MINI MCR-SL-SHUNT-UI-SP-NC MINI MCR-SL-U-UI-SP MINI MCR-SL-U-UI-SP-NC MINI MCR-SL-U-I-0-SP MINI MCR-SL-U-I-4-SP MINI MCR-SL-I-U-0-SP MINI MCR-SL-I-U-4-SP MINI MCR-SL-I-I-SP MINI MCR-SL-U-U-SP MINI MCR-SL-UI-2I-SP MINI MCR-SL-UI-2I-SP-NC MINI MCR-SL-RPS-I-I-SP MINI MCR-SL-RPSS-I-I-SP MINI MCR-SL-1CP-I-I-SP MINI MCR-SL-2CP-I-I MINI MCR-SL-2CP-I-I-SP MINI MCR-SL-PT100-UI-200 MINI MCR-SL-PT100-UI-200-NC MINI MCR-SL-PT100-UI-200-SP MINI MCR-SL-PT100-UI-200-SP-NC MINI MCR-SL-PT100-UI MINI MCR-SL-PT100-UI-NC MINI MCR-SL-PT100-UI-SP MINI MCR-SL-PT100-UI-SP-NC MINI MCR-SL-PT100-UI-LP MINI MCR-SL-PT100-UI-LP-NC MINI MCR-SL-PT100-UI-LP-SP MINI MCR-SL-PT100-UI-LP-SP-NC MINI MCR-SL-UI-F-SP MINI MCR-SL-NAM-2RNO-SP MINI MCR-SL-UI-REL-SP MINI MCR-SL-R-UI MINI MCR-SL-R-UI-SP 2864383 2864150 2864710 2864163 2810874 2810793 2811213 2810078 2813570 2813583 2813554 2813567 2864723 2864697 2864804 2864189 2864752 2810230 2864749 2864655 2864781 2864309 2864370 2864192 2864202 2864435 2864273 2864736 2864286 2810298 2810308 2810382 2810395 2810243 2810269 2864493 2864095 2810256 Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com Surge protection PHOENIX CONTACT 355 INTERFACE Analog MACX Analog / MCR Analog Modular converters for MCR technology 356 PHOENIX CONTACT Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com INTERFACE Analog Isolation MACX Analog / MCR Analog Isolation: – Configurable and standard 3-way isolation amplifiers with electrical isolation between input, output, and supply – Configurable signal multipliers to double analog standard signals – Repeater power supplies for supply and signal transmission – Configurable loop-powered isolators and standard passive isolators The signal isolators are used to electrically isolate, amplify, filter and adjust analog signals. Temperature Isolation Temperature: – Programmable temperature transducers – Configurable temperature transducers for Pt 100 – Temperature relays for Pt 100 – Configurable temperature transducers for thermocouples of the types J and K – Programmable loop-powered temperature transducers The temperature transducers convert the input signals (e.g. Pt 100, Ni 1000, ... or thermocouples of the types J, K, ...) into standard signals. Conversion Temperature Conversion: – Programmable frequency transducers for frequencies of up to 120 kHz The measuring transducers convert different signal values to analog signals suitable for the control system. Analog signals are just as easy to adapt to the control level as are frequencies, rotational speeds and potentiometer positions. Control Conversion Control: – Programmable threshold value switches for resistance thermometers, thermocouples and analog standard signals – Threshold value switches for analog standard signals – Constant voltage source for presetting a reference voltage of 10 V – Programmable digital displays Monitoring modules are also used in measuring and control technology in addition to the common control systems such as PLCs and PCs. They record analog signals and control and monitor a function depending on the signal value. Power Control Power: – Current transducers for sinusoidal and non-sinusoidal alternating currents of up to 100 A, 200 A or 400 A – Configurable and programmable true r.m.s. value current transducers for converting DC, AC and distorted currents of up to 11 A or 55 A – Active and passive r.m.s. value current transducers for converting sinusoidal AC currents of up to 1 A or 5 A – Current protectors for sinusoidal alternating currents of up to 16 A The current and voltage transducers convert currents and voltages into analog standard signals. Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com Power PHOENIX CONTACT 357 INTERFACE Analog MACX Analog / MCR Analog Configurable 3-way isolation amplifiers 99 114,5 Isolation FL 12,5 IN U,I U,I OUT MACX MCR-UI-UI-UP POWER Configurable 3-way isolation amplifier with safe isolation and long range supply. Housing width 12.5 OUT – 3-way isolation – Configurable input and output signals – Long range supply of 19.2 V AC/DC ... 253 V AC/DC – + solid The MACX MCR-UI-UI 3-way isolation amplifiers are used for electrical isolation and conversion of standard analog signals. 3-way isolation prevents different sensor circuits interfering with each other and thereby improves the quality of your measuring circuit. DIP switches enable the inputs and outputs of the isolation amplifier to be reconfigured, allowing more than 1600 signal conversions to be set. The desired input and output signal combination must be specified when ordering pre-configured modules (refer to the order key). If specification details are incorrect or missing, the devices will be supplied with the standard configuration (input signal 0...10 V, output signal 0...20 mA). Pluggable screw connection Spring-cage conn. stranded [mm2] 0.2-2.5 0.2-2.5 AWG 24-14 0.2-1.5 24-16 4.2 3.1 4.1 Passiv + Screw M3 Description – 2.2 5.2 GND 2.1 5.1 ± 1V ... ± 100V 1.2 Type Order No. MACX MCR-UI-UI-UP MACX MCR-UI-UI-UP-SP MACX MCR-UI-UI-UP-NC MACX MCR-UI-UI-UP-SP-NC 2811459 2811585 2811297 2811569 Pcs. / Pkt. MCR 3-way isolation amplifier, for electrical isolation of analog signals with long-range power supply Order configuration Order configuration Standard configuration Standard configuration Screw connection Spring-cage connection Screw connection Spring-cage connection Technical data Input data Input signal (configurable using the DIP switch) Maximum input signal Input resistance Output data Output signal (configurable using the DIP switch) Maximum output signal Load RB General data Supply voltage UB Transmission error, max. Temperature coefficient ZERO / SPAN adjustment Limit frequency (3 dB) Step response (10-90%) Test voltage, input/output/supply Rated insulation voltage Degree of protection Ambient temperature (operation) Assembly Housing material Conformance / approvals Conformity ATEX IECEx UL, USA / Canada Functional safety (SIL) GL PHOENIX CONTACT 3.2 ± 50mV ... ± 1000mV ± 1mA ... ± 5mA ± 10mA ... ± 100mA 1.1 Power dissipation 358 0.2-1.5 IN Aktiv 1 1 1 1 U input I input 0 ... 10 V, please indicate any different setting when ordering ± 100 V ± 100 mA Approx. 1 MΩ Approx. 10 Ω (± 1 V DC ... ± 100 V DC) (± 10 mA DC ... ± 100 mA DC) U output I output 0 ... 20 mA, please indicate any different setting when ordering 15 V 35 mA ≥ 1 kΩ (10 V) active: ≤ 600 Ω (20 mA) (passive: ≤ (UB-2 V) / Ioutmax) 24 V AC/DC ... 230 V AC/DC (-20%/+10%, 50/60 Hz) < 0.8 W (at 24 V DC / 20 mA) < 0.9 W (at 230 V AC / 20 mA) ≤ 0.1% (compared to the final value) 0.0075%/K ± 4% / ± 4% 10 kHz (Can be switched to 30 Hz) 35 µs (at 10 kHz) 11 ms (at 30 Hz) 2.5 kV (50 Hz, 1 min.) 300 V AC IP20 -20°C ... 70°C Any Polyamide (PA 6.6) CE compliant X II 3 G Ex nA nL II T4 Ex nA nL II T4 UL applied for SIL 2 according to EN 61508 GL applied for Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com INTERFACE Analog MACX Analog / MCR Analog Order key MACX MCR-UI-UI-... (Standard configuration entered as example) Input Order No. 2811459 Output / IN03 IN40 IN24 IN41 IN25 IN43 IN44 IN26 IN27 IN28 IN66 IN29 IN50 IN30 IN52 IN05 IN03 IN67 IN32 IN39 IN68 IN69 2811459 = ...-UI-UI-UP 2811585 = ...-UI-UI-UP-SP = = = = = = = = = = = = = = = = = = = = = 0...50 mV 0...60 mV 0...75 mV 0...100 mV 0...120 mV 0...150 mV 0...200 mV 0...300 mV 0...500 mV 0...1000 mV 0...1.0 V 0...1.5 V 0...2.0 V 0...3.0 V 0...5 V 0...10 V 0...15 V 0...20 V 0...30 V 0...50 V 0...100 V IN53 IN13 IN54 IN14 IN56 IN57 IN15 IN16 IN17 IN78 IN18 IN63 IN19 IN65 IN21 IN22 IN79 IN23 IN80 IN81 IN82 = = = = = = = = = = = = = = = = = = = = = Limit frequency / -50...+50 mV -60...+60 mV -75..+75 mV -100..+100 mV -120...+120 mV -150...+150 mV -200...+200 mV -300...+300 mV -500...+500 mV -1000...+1000 mV -1.0...+1.0 V -1.5...+1.5 V -2.0...+2.0 V -3.0...+3.0 V -5...+5 V -10...+10 V -15...+15 V -20...+20 V -30...+30 V -50...+50 V -100...+100 V IN06 = 1...5 V IN04 = 2...10 V IN70 IN71 IN72 IN73 IN36 IN37 IN74 IN01 IN75 IN76 IN77 = = = = = = = = = = = 0...1.0 mA 0...1.5 mA 0...2.0 mA 0...3.0 mA 0...5 mA 0...10 mA 0...15 mA 0...20 mA 0...30 mA 0...50 mA 0...100 mA IN83 IN84 IN85 IN86 IN33 IN34 IN87 IN35 IN88 IN89 IN90 = = = = = = = = = = = -1.0...+1.0 mA -1.5...+1.5 mA -2.0...+2.0 mA -3.0...+3.0 mA -5...+5 mA -10...+10 mA -15...+15 mA -20...+20 mA -30...+30 mA -50...+50 mA -100...+100 mA OUT01 OUT19 = 0...2.5 V OUT05 = 0...5 V OUT03 = 0...10 V OUT15 = 0...5 mA OUT16 = 0...10 mA OUT01 = 0...20 mA OUT20 = -2.5...+2.5 V OUT13 = -5...+5 V OUT14 = -10...+10 V OUT21 = -5...+5 mA OUT22 = -10...+10 mA OUT23 = -20...+20 mA OUT24 = 0.5...+2.5 V OUT06 = 1...5 V OUT04 = 2...10 V OUT25 = 1...5 mA OUT26 = 2...10 mA OUT02 = 4...20 mA OUT27 = 2.5...0 V OUT11 = 5...0 V OUT09 = 10...0 V OUT28 = 5...0 mA OUT29 = 10...0 mA OUT07 = 20...0 mA / 30 30 = 30 Hz 10K = 10 kHz Factory calibration certificate / NONE = Without certificate = With factory calibration certificate (fee) YESPLUS = Factory calibration certificate with 5 measuring points (fee) NONE YES IN91 = 1...5 mA IN92 = 2...10 mA IN02 = 4...20 mA Application example: Level measurement and active analog input card MACX MCR-UI-UI-UP IN Level sensor 4.2 0...20mA 24V 4.1 5.2 5.1 OUT ±50mV... ±1000mV ±1mA... ±5mA – active ±10mA... ±100mA 3.2 + 3.1 GND 2.2 passive ±1V... ±100V 2.1 Power 24V ...230V AC/DC 1.2 ≃ 1.1 Control system Power 24V ...230V AC/DC Application example: Shunt measurement and Inline terminal with analog input channels within an Inline station MACX MCR-UI-UI-UP M IN 4.2 Shunt resistor mV 4.1 5.1 – ±10mA... ±100mA – active 3.2 D + 3.1 AI2 5.2 + OUT ±50mV... ±1000mV ±1mA... ±5mA GND ±1V... ±100V 2.2 passive 1 2.1 Power 24V ...230V AC/DC 2 1 1 2 2 3 3 4 4 1.2 ≃ 1.1 Battery Power 24V ...230V AC/DC IB IL AI 2/SF (Information about automation solutions from Phoenix Contact is given in the AUTOMATION catalog or under www.phoenixcontact.com) Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com PHOENIX CONTACT 359 INTERFACE Analog MACX Analog / MCR Analog Configurable 3-way isolation amplifiers FL Isolation 17,5 114,5 99 IN U,I U,I OUT MCR-C-UI-UI-DCI POWER Configurable 3-way isolation amplifiers with more than 225 signal conversion functions uPFz Ex: U Housing width 17.5 IN – 3-way isolation – Configurable input and output signals – Alternatively limit frequency 30 Hz or 450 Hz Pluggable screw connection The MCR-C-UI-UI-DCI 3-way isolation amplifiers are used for electrical isolation and conversion of standard analog signals. 3-way isolation prevents different sensor circuits interfering with each other and thereby improves the quality of your measuring circuit. DIP switches enable the inputs and outputs of the isolation amplifier to be reconfigured, allowing more than 225 signal conversions to be set. The desired configuration of the input and output signal can be stated in the order (refer to the order key and the combination table). If the customer order details are incorrect or missing, the devices are supplied with the standard configuration (input signal 0...10 V, output signal 0...10 V). PHOENIX CONTACT AWG 24-14 MCR 3-way isolation amplifier, for electrical isolation of analog signals, with limit frequency (3 dB) 30 Hz Order configuration with limit frequency (3 dB) 30 Hz Standard configuration with limit frequency (3 dB) 450 Hz, Order configuration without GL and UL approval Technical data Input data Input signal (configurable using the DIP switch) Maximum input signal Input resistance Output data Output signal (configurable using the DIP switch) Maximum output signal Load RB General data Supply voltage UB Current consumption Transmission error, max. Temperature coefficient ZERO / SPAN adjustment Limit frequency (3 dB) Step response (10-90%) Test voltage input/output Test voltage power supply/signal Degree of protection Ambient temperature (operation) Assembly Housing material Conformance / approvals Conformity UL, USA / Canada 7 OUT I 8 OUT U 9 GND 2 U, U Screw M3 Description GL 360 stranded [mm2] 0.2-2.5 0.2-2.5 IN U/I 1 GND 1 2 GND 1 3 solid OUT 10 +24V DC 11 GND 3 12 GND 3 Type Order No. MCR-C-UI-UI-DCI MCR-C-UI-UI-DCI-NC MCR-C-UI-UI-450-DCI 2810913 2810939 2810887 Pcs. / Pkt. 1 1 1 U input I input 0 ... 10 V, please indicate any different setting when ordering 30 V 50 mA 1 MΩ 50 Ω U output I output 0 ... 10 V, please indicate any different setting when ordering 15 V 30 mA ≥ 10 kΩ ≤ 500 Ω MCR-C-UI-UI-DCI MCR-C-UI-UI-450-DCI 18 V DC ... 30 V DC 18 V DC ... 30 V DC < 30 mA (without load) < 30 mA (without load) ≤ 0.1% (of end value) ≤ 0.1% (of end value) 0.0075%/K 0.0075%/K ± 2% / ± 2% ± 2% / ± 2% 30 Hz 450 Hz 11 ms 0.8 ms 1.5 kV (50 Hz, 1 min.) 1.5 kV (50 Hz, 1 min.) 1 kV (50 Hz, 1 min.) 1 kV (50 Hz, 1 min.) IP20 IP20 -20°C ... 65°C -20°C ... 65°C Any Any Polyamide PA non-reinforced Polyamide PA non-reinforced CE compliant Class I, Div. 2, Groups A, B, C, D or non-hazardous locations Germanischer Lloyd Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com CE compliant - INTERFACE Analog MACX Analog / MCR Analog Order key MCR-C-UI-UI-...-DCI (Standard configuration entered as example) Output Order No. Factory calibration certificate / NONE Input 2810913 / 2810913 = MCR-C-UI-UI-DCI 2810887 = MCR-C-UI-UI-450DCI IN03 IN01 IN02 IN03 IN05 IN06 IN13 IN14 IN15 IN16 IN17 = = = = = = = = = = 0...20 mA 4...20 mA 0...10 V 0...5 V 1...5 V -60...+60 mV -100..+100 mV -200...+200 mV -300...+300 mV -500...+500 mV IN18 IN19 IN20 IN21 IN22 IN23 IN24 IN25 IN26 IN27 IN28 = = = = = = = = = = = / -1...+1 V -2...+2 V -2.5...+2.5 V -5...+5 V -10...+10 V -20...+20 V 0...60 mV 0...100 mV 0...200 mV 0...300 mV 0...500 mV IN29 IN30 IN31 IN32 IN33 IN34 IN35 IN36 IN37 = = = = = = = = = 0...1 V 0...2 V 0...2.5 V 0...20 V -5...+5 mA -10...+10 mA -20...+20 mA 0...5 mA 0...10 mA OUT03 OUT01 OUT02 OUT03 OUT05 OUT06 OUT13 OUT14 OUT15 OUT16 = = = = = = = = = 0...20 mA 4...20 mA 0...10 V 0...5 V 1...5 V -5...+5 V -10...+10 V 0...5 mA 0...10 mA = Without certificate = With factory calibration certificate (fee) YESPLUS = Factory calibration certificate with 5 measuring points (fee) NONE YES Combination table for input and output signals Input 0...60 mV 0...100 mV 0...200 mV 0...300 mV 0...500 mV 0...1 V 0...2 V 0...2.5 V 0...5 V 0...10 V 0...20 V -60...+60 mV -100 ...+100 mV -200 ...+200 mV -300 ...+300 mV -500 ...+500 mV -1...+1 V -2...+2 V -2.5...+2.5 V -5...+5 V -10...+10 V -20...+20 V 0...5 mA 0...10 mA 0...20 mA -5...+5 mA -10...+10 mA -20...+20 mA 1...5 V 4...20 mA 0...10 V x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x Voltage output -10...+10 V 0...5 V -5...+5 V x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x 1...5 V x x x x x x x x x x x 0...5 mA x x x x x x x x x x x x x x x x x x x Current output 0...10 mA 0...20 mA x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x 4...20 mA x x x x x x x x x x x x x x x x Application example: Level measurement Level sensor 0...20mA 3 GND 1 MCR-C-UI-UI-DCI ZERO 2 GND 1 SPAN U/I POWER 1 OUT T 24V 7 POWER (+) 24V U 8 GND 3 11 GND 2 9 GND 3 12 10 24V Mains voltage 0...10V Control system Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com PHOENIX CONTACT 361 INTERFACE Analog MACX Analog / MCR Analog Configurable signal multiplier 99 17,5 Isolation 114,5 OUT1 FL U,I IN U,I U,I OUT2 MCR-FL-C-UI-2UI-DCI POWER Signal multiplier with configurable input and two outputs uPz Ex: U Housing width 17.5 OUT – 4-way isolation – Configurable input and output signals – Balanced signal combinations solid The MCR-C-UI-2UI-DCI signal multiplier is used for electrical isolation and conversion of analog signals. Module input, both outputs, and supply are electrically isolated from one another. Modules can therefore be used for electrical isolation, signal conversion, and signal amplification on site as well as near the controller. A green power LED indicates that supply voltage is present. Each of the two outputs has one current output and one voltage output which can be used in parallel. It is possible to switch between a signal selected within the limits of the order key or the signal conversions listed in the configuration table, using DIP switches. It is not necessary to calibrate after reconfiguration because each transmission type has already been calibrated and stored in the device. The desired configuration of the input and output signal can be stated in the order (refer to the order key and the combination table). If the customer order details are incorrect or missing, the devices are supplied with the standard configuration (input signal 0...20 mA, output signal 0...20 mA). 362 PHOENIX CONTACT Pluggable screw connection stranded [mm2] 0.2-2.5 0.2-2.5 OUT I2 1 OUT U2 2 GND 2 3 AWG 24-14 Screw M3 D A D IN I 4 IN U 5 GND 3 6 OUT A 7 OUT I1 8 OUT U1 9 GND 1 +24V DC GND 4 12 GND 4 10 A 11 D IN Description Type Order No. MCR signal multiplier, for multiplying and electrical isolation of analog signals, Order configuration Standard configuration MCR-FL-C-UI-2UI-DCI MCR-FL-C-UI-2UI-DCI-NC 2814854 2814867 Technical data Input data Input signal Measuring range span Maximum input signal Input resistance Output data Output signal (configurable using the DIP switch) Maximum output signal Load RB General data Supply voltage UB Current consumption Transmission error, max. Temperature coefficient Limit frequency (3 dB) Step response (10-90%) Test voltage, input/output/supply Degree of protection Ambient temperature (operation) Assembly Housing material Conformance / approvals Conformity UL, USA / Canada U input 0 V ... 12 V (freely selectable in 0.1 V steps) Min. 4 V 30 V 200 kΩ U output refer to the order key 15 V ≥ 10 kΩ Pcs. / Pkt. I input 0 mA ... 24 mA (freely selectable in 0.1 mA steps) Min. 8 mA 50 mA 50 Ω I output refer to the order key 35 mA ≤ 600 Ω 20 V DC ... 30 V DC < 25 mA ≤ 0.15% (of end value), Typ. 0.05% (of end value) < 0.015%/K, Typ. 0.0075%/K 30 Hz 12 ms 1.5 kV (50 Hz, 1 min.) IP20 -25°C ... 55°C Any Polyamide PA non-reinforced CE compliant Class I, Div. 2, Groups A, B, C, D or non-hazardous locations Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com 1 1 INTERFACE Analog MACX Analog / MCR Analog Order key MCR-FL-C-UI-2UI-DCI (Standard configuration entered as example) Order No. 2814854 Input signal range (standard and special signals) Initial value Final value / 0.0 / 20.0 Input signal / I I = Current U = Voltage Output signal (standard signals) Output 1 Output 2 / OUT01 / OUT01 0.0 = 0.0 mA I : Freely selectable between 0.0...24.0 mA 20.0 = 20.0 mA I : Freely selectable between 0.0...24.0 mA U : Freely selectable between 0.0...12.0 mA U : Freely selectable between 0.0...12.0 mA OUT01 OUT02 OUT03 OUT04 OUT05 OUT06 OUT16 = = = = = = = 0...20 mA 4...20 mA 0...10 V 2...10 V 0...5 V 1...5 V 0...10 mA OUT01 OUT02 OUT03 OUT04 OUT05 OUT06 OUT16 = = = = = = = Factory calibration certificate / NONE = Without certificate = With factory calibration certificate (fee) YESPLUS = Factory calibration certificate with 5 measuring points (fee) 0...20 mA 4...20 mA 0...10 V 2...10 V 0...5 V 1...5 V 0...10 mA NONE YES Measuring range span min. 8.0 mA/4.0 V Increment 0.1 mA /0.1 V Ordering examples: 2814854 / Input signal range (standard and special signals) Initial value Final value / 5.3 / 13.3 I I = Current I = 5.3 mA I Output signal (standard signals) Output 1 Output 2 / OUT01 / OUT01 = 13.3 mA OUT01 = 0...20 mA Factory calibration certificate / NONE OUT01 = 0...20 mA NONE = Without factory NONE = Without factory Measuring range span 8.0 mA, i.e. order is possible. 2814854 / U / U = Voltage 7.8 / U = 7.8 V 11.8 / U = 11.8 V OUT01 / OUT01 = 0...20 mA OUT03 / OUT03 = 0...10 V NONE Measuring range span 4.0 V, i.e. order is possible. Combination table for input and output signals set with DIP switches Input 0...20 mA 4...20 mA 0...10 mA 0...20 mA 4...20 mA 0...10 mA 2...10 mA 0...10 V 2...10 V 0...5 V 1...5 V x x x x x x x x x x x x x x x x Output 1 0...10 V 0...5 V 1...5 V 2...10 V x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x 0...20 mA 4...20 mA 0...10 mA x x x x x x x x x x x x x x x x Output 2 0...10 V 0...5 V 1...5 V 2...10 V x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x Application example: Level measurement with subsequent signal multiplication Level sensor 0...20mA 24V 0...20mA IN OUT 2 I2 I 1 5 U 2 U2 6 GND 3 3 GND 2 POWER 4 MCR-FL-C-UI-2UI-DCI 7 POWER +24V U1 8 GND 4 11 GND 1 9 GND 4 12 OUT 1 I 10 Control system 0...10V 15m3 24V Mains voltage Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com PHOENIX CONTACT 363 INTERFACE Analog MACX Analog / MCR Analog Standard signal 3-way isolation amplifiers 99 Isolation 114,5 12,5 IN U,I U,I OUT MCR-C-...-DC SL POWER 3-way isolation amplifier uPz Housing width 12.5 IN – Processing standard signals – Fixed setting of input and output signals – 3-way isolation The MCR-C-...-DC 3-way isolation amplifiers are used for electrical isolation and conversion of standard analog signals. The devices are electrically isolated from each other in the input, output and supply circuit. The isolation amplifier allows electrical isolation of the sensor circuit from the evaluation circuit, thus also preventing reciprocal interference between several sensor circuits. As a result of the 3-way isolation, the modules can be used both on site or close to the control unit for signal conversion and electrical isolation, as well as on the transmission route to bridge high load resistances. Pluggable screw connection stranded [mm2] 0.2-2.5 0.2-2.5 Description PHOENIX CONTACT AWG 24-14 5 OUT I/U 6 GND 2 U, U Screw M3 7 +20...30V 8 GND 3 Input signal Output signal MCR 3-way isolation amplifier, for electrical isolation of analog signals, 0 ... 10 V 0 ... 20 mA 0 ... 10 V 4 ... 20 mA 0 ... 20 mA 4 ... 20 mA 4 ... 20 mA 0 ... 20 mA 4 ... 20 mA 0 ... 10 V 0 ... 20 mA, 0 ... 20 mA, 4 ... 20 mA 4 ... 20 mA 0 ... 20 mA, 0 ... 10 V, -20 ... 20 mA -10 ... 10 V 0 ... 10 V, 0 ... 10 V, -10 ... 10 V -10 ... 10 V Pcs. / Pkt. Type Order No. MCR-C-U-I- 0-DC MCR-C-U-I- 4-DC MCR-C-I-I-04-DC MCR-C-I-I-40-DC MCR-C-I-U- 4-DC MCR-C-I-I-00-DC 2814472 2814537 2814540 2814524 2814511 2814508 5 5 5 5 5 5 MCR-C-I-U- 0-DC 2814498 5 MCR-C-U-U-DC 2814469 5 Technical data Input data Input signal U input 0 ... 10 V / -10 ... 10 V Maximum input signal Input resistance Output data Output signal Maximum output signal Load RB Linear transmission range (in reference to the output range end value) 30 V 200 kΩ U output 0 ... 10 V / -10 ... 10 V 15 V > 10 kΩ -10% ... 110% -110% ... 110% (bipolar signals) General data Supply voltage UB Current consumption Transmission error, max. 20 V DC ... 30 V DC < 15 mA (without load) ≤ 0.3% (of end value), Typ. < 0.2% (of end value) Temperature coefficient Limit frequency (3 dB) Step response (10-90%) Test voltage, input/output/supply Ambient temperature (operation) Assembly Housing material Conformance / approvals Conformity 364 IN I/U 1 GND 1 2 solid OUT < 0.015%/K 30 Hz 11 ms 1.5 kV (50 Hz, 1 min.) -25°C ... 60°C Any Polyamide PA non-reinforced CE compliant Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com I input 0 ... 20 mA / 4 ... 20 mA -20 ... 20 mA 50 mA 50 Ω I output 0 ... 20 mA / 4 ... 20 mA 30 mA ≤ 500 Ω -5% ... 105% INTERFACE Analog MACX Analog / MCR Analog Repeater power supply HART 12,5 POWER 7 114,5 Isolation 99 I I OUT IN SL MACX MCR-SL-RPSSI-I POWER Repeater power supply for supplying 2 and 3-conductor transmitters with HART transmission Housing width 12.5 IN – – – – – – – Input 0/4...20 mA (feeding or non-feeding) Output 0/4...20 mA (active or passive) HARTable Up to SIL 2 according to EN 61508 Galvanic 3-way isolation Installation in zone 2 permissible Power supply via DIN rail connector possible The repeater power supply MACX MCR-SL-RPSSI-I has been designed for the operation of measuring transducers and mA current sources. The 2-wire measuring transducers are supplied with power, and analog 0/4...20 mA measured values are transferred from the field. 4-wire measuring transducers and mA current sources can be operated via a nonfeeding input. The module output can be operated actively or passively. The analog measured value can be overlayed with digital (HART) communication signals and transmitted bidirectionally. An additional resistance can be switched in the output circuit in order to increase the HART impedance in low-ohmic systems using a terminal point. Receptacles are integrated into the COMBICON connectors for connecting the HART communicators. OUT 4.2 4.1 Connection data Screw connection Torque Spring-cage conn. solid stranded [mm2] AWG 0.2-2.5 0.2-2.5 24-14 0.5...0.6 Nm 0.2-1.5 0.2-1.5 24-16 5.2 Screw M3 5.1 – + – + Source 4.2 3.2 4.1 3.1 - + Sink + - 2.2 5.2 250 W 5.1 2.1 - + 1.2 GND 1.1 +24V ME 6,2 TBUS-... Description Type Order No. MACX MCR-SL-RPSSI-I MACX MCR-SL-RPSSI-I-SP 2865955 2924207 Pcs. / Pkt. MCR repeater power supply with HART protocol Screw connection Spring-cage conn. Technical data Input data Input signal Transmitter supply voltage Voltage drop Output data Output signal 0 mA ... 20 mA / 4 mA ... 20 mA > 16 V (at 20 mA) < 3.5 V (in input isolation amplifier operation) 0 mA ... 20 mA (active) 4 mA ... 20 mA (active) 0 mA ... 20 mA (passive, ext. source voltage 14...26 V) 4 mA ... 20 mA (passive, ext. source voltage 14...26 V) < 600 Ω < 20 mVrms Load Output ripple General data Supply voltage range Current consumption Power dissipation Temperature coefficient Step response (10-90%) Transmission error, typical Transmission error, max. Under/overload range Electrical isolation 19.2 V DC ... 30 V DC < 60 mA (for 24 V DC) < 1.1 W (at 24 V DC / 20 mA) < 0.01%/K < 600 µs (for jump 4 mA ... 20 mA) < 0.05% (of end value) < 0.1% (of end value) as per NE 43 Input/output/power supply Accessories: Information about the supply and error evaluation module as well as about the DIN rail connectors and marking material can be found from page 445. Input/output Input/power supply Ambient temperature range Status indication SMART communication Signal bandwidth Protocols supported Housing material Conformance / approvals Conformity ATEX IECEx UL, USA / Canada Functional safety (SIL) 1 1 2.5 kV (50 Hz, 1 min., test voltage) 300 Vrms (rated insulation voltage, surge voltage category II; pollution degree 2, safe isolation as per EN 61010, EN 50178) 375 V (peak value in accordance with EN 60079-11) 375 V (peak value in accordance with EN 60079-11) -20°C ... 60°C (any mounting position) LED green (supply voltage) Yes As per HART specifications HART Polyamide (PA 6.6) CE-compliant, additionally EN 61326 X II 3 G Ex nA nL II T4 Ex nA nL II T4 UL applied for SIL 2 according to EN 61508 Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com PHOENIX CONTACT 365 INTERFACE Analog MACX Analog / MCR Analog Repeater power supply HART 17,5 POWER 114,5 Isolation 99 I I OUT IN SL MACX MCR-SL-RPSSI-I-UP POWER Repeater power supply for supplying 2 and 3-conductor transmitters with HART transmission, with long range supply Housing width 17.5 IN Input 0/4...20 mA (feeding or non-feeding) Output 0/4...20 mA (active or passive) HARTable Up to SIL 2 according to EN 61508 Galvanic 3-way isolation Installation in zone 2 permissible Long range supply of 19.2 V AC/DC ... 253 V AC/DC The repeater power supply MACX MCR-SL-RPSSI-I-UP has been designed for the operation of measuring transducers and mA current sources. The 2-wire measuring transducers are supplied with power, and analog 0/4...20 mA measured values are transferred from the field. 4-wire measuring transducers and mA current sources can be operated via a nonfeeding input. The module output can be operated actively or passively. The analog measured value can be overlayed with digital (HART) communication signals and transmitted bidirectionally. An additional resistance can be switched in the output circuit in order to increase the HART impedance in low-ohmic systems using a switch on the front of the device. The power supply has been designed as a long range supply (UP). Receptacles are integrated into the COMBICON connectors for connecting the HART communicators. 4.3 4.2 Connection data Screw connection Torque Spring-cage conn. stranded [mm2] AWG 0.2-2.5 0.2-2.5 24-14 0.5...0.6 Nm 0.2-1.5 0.2-1.5 24-16 4.1 solid 4.1 Source 250 W 3.2 S1 4.3 4.2 – + 3.1 1.2 1.1 Description - Sink + + ≃ 24 ... 230 V AC/DC Type Order No. MACX MCR-SL-RPSSI-I-UP MACX MCR-SL-RPSSI-I-UP-SP 2865968 2924210 Pcs. / Pkt. MCR repeater power supply with HART protocol Screw connection Spring-cage conn. Technical data Input data Input signal Transmitter supply voltage Voltage drop Output data Output signal 0 mA ... 20 mA / 4 mA ... 20 mA > 16 V (at 20 mA) < 3.5 V (in input isolation amplifier operation) 0 mA ... 20 mA (active) 4 mA ... 20 mA (active) 0 mA ... 20 mA (passive, ext. source voltage 14...26 V) 4 mA ... 20 mA (passive, ext. source voltage 14...26 V) 0 V ... 5 V (internal resistance, 250 Ω, 0.1%) 1 V ... 5 V (internal resistance, 250 Ω, 0.1%) < 600 Ω (I output) < 20 mVrms Load Output ripple General data Supply voltage range 24 V AC/DC ... 230 V AC/DC (-20%/+10%, 50/60 Hz) Current consumption Power dissipation Temperature coefficient Step response (10-90%) Transmission error, typical Transmission error, max. Under/overload range Electrical isolation < 75 mA (for 24 V DC) < 1.8 W < 0.01%/K < 600 µs (for jump 4 mA ... 20 mA) < 0.05% (of end value) < 0.1% (of end value) as per NE 43 Input/output/power supply Ambient temperature range Status indication SMART communication Signal bandwidth Protocols supported Housing material Conformance / approvals Conformity ATEX IECEx UL, USA / Canada Functional safety (SIL) PHOENIX CONTACT 4.2 Screw M3 Input/output Input/power supply 366 – + - 3.3 S2 250 W – – – – – – – OUT 2.5 kV (50 Hz, 1 min., test voltage) 300 Vrms (rated insulation voltage, surge voltage category II; pollution degree 2, safe isolation as per EN 61010, EN 50178) 375 V (peak value in accordance with EN 60079-11) 375 V (peak value in accordance with EN 60079-11) -20°C ... 60°C (any mounting position) LED green (supply voltage) Yes As per HART specifications HART Polyamide (PA 6.6) CE-compliant, additionally EN 61326 X II 3 G Ex nA nL II T4 Ex nA nL II T4 UL applied for SIL 2 according to EN 61508 Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com 1 1 INTERFACE Analog MACX Analog / MCR Analog Configurable loop-powered isolator 17,5 114,5 99 Isolation FL IN U,I POWER I OUT MCR-CLP-UI-I-4 Loop-powered isolator with a configurable input uPz Ex: U Housing width 17.5 IN – – – – – No separate voltage supply Electrically isolated input Configurable input 4...20 mA output Zero/span adjustment (± 2%) OUT IN U/I 1 solid Pluggable screw connection The MCR-CLP-UI-I-4 loop-powered isolator is used for electrical isolation and signal conditioning in analog signal circuits. On the input side, more than 25 different signal ranges can be set using DIP switches. On the output side, the isolator is operated in a 4...20 mA current loop, which simultaneously provides the power supply for the module necessary for signal conversion. The desired configuration of the input signal must be specified in the order (refer to the order key). If customer order details are missing or faulty, devices with the standard configuration are supplied (input signal 4...20 mA). stranded [mm2] 0.2-2.5 0.2-2.5 AWG 24-14 Screw M3 GND 2 GND 3 U, DC DC 7 (+) 8...30VDC 8 OUT I 9 NC U, Description Type Order No. MCR loop-powered isolator, for electrical isolation of analog signals, Order configuration Standard configuration MCR-CLP-UI-I-4 MCR-CLP-UI-I-4-NC 2814058 2814252 Technical data Input data Input signal (configurable using the DIP switch) Maximum input signal Input resistance Output data Output signal Maximum output signal Load RB 1 1 U input I input 4 ... 20 mA, please indicate any different setting when ordering 30 V 50 mA 1 MΩ 50 Ω 4 ... 20 mA 35 mA ≤ 800 Ω (at UB = 24 V; otherwise: (UB - 8 V) / 20 mA) General data Supply voltage UB Transmission error, max. Temperature coefficient ZERO / SPAN adjustment Limit frequency (3 dB) Step response (10-90%) Test voltage input/output Ambient temperature (operation) Assembly Housing material Conformance / approvals Conformity UL, USA / Canada Order key MCR-CLP-UI-I-4 (Standard configuration entered as example) Pcs. / Pkt. 8 V DC ... 30 V DC ≤ 0.1% (of end value), Typ. 0.05% ≤ 0.01%/K, Typ. 0.005%/K ± 2% (of end value) / ± 2% (of end value) 30 Hz 11 ms 1.5 kV (50 Hz, 1 min.) -25°C ... 65°C Any Polyamide PA non-reinforced CE compliant Class I, Div. 2, Groups A, B, C, D or non-hazardous locations Level measurement + Order No. 2814058 Input / Factory calibration certificate / NONE IN02 IN18 IN19 IN21 IN22 IN23 IN24 IN25 IN26 IN27 IN28 = -1...+1 V = -2...+2 V = -5...+5 V = -10...+10 V = -20...+20 V = 0...60 mV = 0...100 mV = 0...200 mV = 0...300 mV = 0...500 mV IN29 IN30 IN32 IN33 IN34 IN35 IN36 IN37 = 0...1 V = 0...2 V = 0...20 V = -5...+5 mA = -10...+10 mA = -20...+20 mA = 0...5 mA = 0...10 mA = Without certificate = With factory calibration certificate (fee) YESPLUS = Factory calibration certificate with 5 measuring points (fee) NONE YES 0...20mA U B = 24V 1 IN U/I 2 GND 3 GND Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com MCR-CLP-U-I-4 ZERO = 0...20 mA = 4...20 mA = 0...10 V = 0...5 V = 1...5 V = -60...+60 mV = -100..+100 mV = -200...+200 mV = -300...+300 mV = -500...+500 mV 24V SPAN IN01 IN02 IN03 IN05 IN06 IN13 IN14 IN15 IN16 IN17 - Level sensor +UB 7 I 8 NC 9 24V Mains voltage 4...20mA Active PLC input card PHOENIX CONTACT 367 INTERFACE Analog MACX Analog / MCR Analog Single-channel passive isolator with safe isolation 99 Isolation 114,5 12,5 IN I I OUT MCR-SL-1CLP-I-I-00-4KV Passive isolator with safe isolation, 1-channel SL uPz Housing width 12.5 – Electrical isolation without additional auxiliary power supply – Current signals 0(4)...20 mA – Safe isolation IN Pluggable screw connection The MCR-SL-1CLP-I-I-00-4KV passive isolators are used for electrical isolation of analog current standard signals. The components guarantee electrical isolation between the control electronics and process peripherals. Furthermore, interference signal parts above 75 Hz are effectively suppressed. Input and output circuits require no additional auxiliary power. This is obtained by the modules from the input signal. When passive isolators are used, one must make sure that the current sourcing voltage of the measuring transducer UB is sufficient to drive the maximum current of 20 mA via the passive isolator with the voltage drop UV = 2.5 V and the load RB. This means: UB ≥ UE = 2.5 V + 20 mA x RB stranded [mm2] 0.2-2.5 0.2-2.5 AWG 24-14 Screw M3 Description 5 (+) 20mA 6 (-) GND (+) 0-20mA 1 (-) GND 2 Type Order No. MCR-SL-1CLP-I-I-00-4KV 2814841 Technical data Input data Input signal Voltage drop Response current Maximum input current Maximum input voltage Input voltage limitation Output data Output signal Maximum output signal Load RB Ripple General data Transmission error, max. Additional error per 100 Ω load Temperature coefficient Limit frequency (3 dB) Step response (10-90%) Test voltage input/output Protection against electric shock I I UE 0 ... 20 mA / 4 ... 20 mA 50 mA ≤ 1375 Ω (at I = 20 mA output signal) < 5 mV (rms) ≤ 0.1% (of end value) 0.02% (of measured value / 100 Ω load) ≤ 0.002%/K (of measured value / 100 Ω load) < 75 Hz (at I = 20 mA and maximum load) 5 ms (with 500 Ω load) 4 kV (50 Hz, 1 min.) Increased insulation acc. to DIN EN 61 010 part 1 and safe isolation acc. to VDE 0100 part 410 along the lines of VDE 0106 part 101 up to 300 V AC/DC for surge voltage category II and pollution degree 2 between all isolated distances. -10°C ... 70°C Any Polyamide PA non-reinforced CE compliant I MCR-1CLP 2 5 RB The diagram shows input voltage UE in relation to load RB taking into account voltage failure UV. If you know the load, the minimum voltage the sensor must supply in order to drive the maximum current of 20 mA via the loop-powered isolator and the load can be read off on the Y-axis. 2 0 1 5 1 0 5 0 368 PHOENIX CONTACT 1 0 ... 20 mA / 4 ... 20 mA 2.5 V (at I = 20 mA) < 50 µA 50 mA (100 mA overload) 30 V (30 V overload) 33 V 5% (with Zener diode) Input voltage depending on the load at IA = 20 mA U V = 2,5 V I Pcs. / Pkt. MCR passive isolator, for electrical isolation of current signals without auxiliary power Ambient temperature (operation) Assembly Housing material Conformance / approvals Conformity UB OUT solid Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com 2 0 0 4 0 0 6 0 0 8 0 0 1 0 0 0 INTERFACE Analog MACX Analog / MCR Analog Single or multi-channel loop-powered isolator 99 Isolation 114,5 12,5 IN I I OUT MCR-1CLP-I-I-00 Passive isolator, 1, 2 or 4-channel SL uPz Housing width 12.5 – Electrical isolation without additional auxiliary power supply – Current signals 0(4)...20 mA – Alternatively 1, 2 or 4-channel version IN Pluggable screw connection The MCR-SL-...CLP-I-I-00 passive isolators are used for electrical isolation of analog current standard signals. The components guarantee electrical isolation between the control electronics and process peripherals. Furthermore, interference signal parts above 75 Hz are effectively suppressed. Input and output circuits require no additional auxiliary power. This is obtained by the modules from the input signal. When passive isolators are used, one must make sure that the current sourcing voltage of the measuring transducer UB is sufficient to drive the maximum current of 20 mA via the passive isolator with the voltage drop UV = 2.5 V and the load RB. This means: UB ≥ UE = 2.5 V + 20 mA x RB UB stranded [mm2] 0.2-2.5 0.2-2.5 OUT solid AWG 24-14 Screw M3 5 (+) 20mA 6 (-) GND (+) 0-20mA 1 (-) GND 2 Description Type Order No. MCR passive isolator, for electrical isolation of current signals without auxiliary power 1-channel 12.5 mm wide 2-channel 12.5 mm wide 4-channel 22.5 mm wide MCR-1CLP-I-I-00 MCR-2CLP-I-I-00 MCR-4CLP-I-I-00 2814016 2814029 2814045 Technical data Input data Input signal Voltage drop Response current Maximum input current Maximum input voltage Input voltage limitation Output data Output signal Maximum output signal Load RB Ripple General data Transmission error, max. Additional error per 100 Ω load Temperature coefficient Limit frequency (3 dB) Step response (10-90%) Test voltage input/output Ambient temperature (operation) Assembly Housing material Conformance / approvals Conformity Pcs. / Pkt. 1 1 1 0 ... 20 mA / 4 ... 20 mA 2.5 V (at I = 20 mA) < 50 µA 50 mA (100 mA overload) 30 V (30 V overload) 33 V (with Zener diode) 0 ... 20 mA / 4 ... 20 mA 50 mA ≤ 1375 Ω (at I = 20 mA output signal) < 5 mV (rms) ≤ 0.1% (of end value) 0.02% (of measured value) ≤ 0.002%/K (of measured value / 100 Ω load) < 75 Hz 5 ms (with 500 Ω load) 510 V (50 Hz, 1 min.) -10°C ... 70°C Any Polyamide PA non-reinforced CE compliant Flow measurement U V = 2,5 V I I UE I I MCR-1CLP Magnetic inductive flow gauge RB 24V 0...20mA 0...20mA 1 I 2 GND 1 MCR-1CLP-I-I-00 IN I 5 GND 2 6 OUT Control system Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com PHOENIX CONTACT 369 INTERFACE Analog MACX Analog / MCR Analog Programmable Temperature Transducers FL U,I IN 17,5 114,5 Temperature 99 OUT MCR-T-UI-E POWER Programmable temperature transducers for resistance thermometers and thermocouples uPFz Ex: U Housing width 17.5 IN – For resistance thermometers and thermocouples – Freely programmable via MCR-PI-CONF-WIN – Optional with electrical isolation 1 2 solid Pluggable screw connection The programmable MCR-T-UI temperature transducers convert temperature signals from resistance thermometers and thermocouples as well as from sensors with linear mV characteristic curves into standard analog signals. As an option, two thermocouples can be connected to measure the differential temperature. A downstream analog stage converts the signal, electrically isolated as an option, into 0(4)...20 mA, 0...(5)10 V, ± (5)10 V or its inverse signals. The MCR-T modules also have an electronic switching output (PNP transistor output 100 mA/24 V). The transmission behavior of the temperature transducer is stated in the order or set with the configuration software MCR/PI-CONF-WIN, refer to page 389. The MCR-T modules are delivered unconfigured or with order-specific configuration on the basis of the order key. stranded [mm2] 0.2-2.5 0.2-2.5 D A 3 Screw M3 4 NC 5 NC 6 7 D C 8 9 10 = = (+) 24VDC 11 SP 12 (-) GND Type Order No. MCR-T-UI-E MCR-T-UI-E-NC MCR-T-UI MCR-T-UI-NC 2814113 2814126 2814090 2814100 Pcs. / Pkt. MCR temperature transducers, for resistance thermometers and thermocouple sensors, with electrical isolation of input/output and input/supply voltage Order configuration Standard configuration Order configuration, without electrical isolation Standard configuration, without electrical isolation Technical data Input data Resistance thermometers Thermocouple sensors Resistor Voltage Temperature range Sensor input current Output data Output signal Maximum output signal Resolution D/A Load RB Ripple Output signal with open circuit Measuring range overrange/underrange Switching output Cold point errors Temperature coefficient Test voltage input/output Test voltage input/power supply Ambient temperature (operation) Assembly Housing material Conformance / approvals Conformity UL, USA / Canada GL PHOENIX CONTACT AWG 24-14 Description General data Supply voltage UB Current consumption Transmission error, max. 370 OUT 1 1 1 1 Pt, Ni, Cu sensors : 2, 3, 4-wire U, T, L, J, E, K, N, S, R, B, C, W, HK 0 Ω ... 8000 Ω (freely adjustable) -20 mV ... 2400 mV (freely adjustable) (Depending on sensor type used) 250 µA (resistance thermometer) U output I output 0 ... 5 V / 0 ... 10 V 0 ... 20 mA / 4 ... 20 mA -5 ... 5 V / -10 ... 10 V ± 12 V 24 mA ± 12 Bit ± 12 Bit ≥ 10 kΩ ≤ 500 Ω < 20 mVPP -12 V ... 12 V 0 A ... 24 mA -12 V ... 12 V 0 A ... 24 mA Transistor output, pnp Can carry a load of 100 mA, switches supply voltage (not protected against short circuit); locked in case of order-specific configuration, otherwise freely programmable through MCR/PI-CONF-WIN 18 V DC ... 30 V DC ≤ 60 mA, Typ. 40 mA ≤ 0.1% (of final value, ± 6 mV or ± 12 µA at output) ≤ 3 K, Typ. 1.5 K ≤ 0.01%/K, Typ. 0.005%/K 1 kV (50 Hz, 1 min.) 1 kV (50 Hz, 1 min.) -20°C ... 65°C Any Polyamide PA non-reinforced CE compliant Class I, Div. 2, Groups A, B, C, D or non-hazardous locations Germanischer Lloyd Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com INTERFACE Analog MACX Analog / MCR Analog Order key MCR-T-UI(-E)/... (Standard configuration entered as example) Sensor type Order No. 2814113 / PT100 / Refer to tables under "Sensor type" 2814113 = MCR-T-UI-E 2814090 = MCR-T-UI Input characteristic curve Connection method D / D = DIN S = SAMA (see table) 3 2 3 4 0 0 = At Ni1000 (Landis&Gyr), Cu10, Cu50, Cu53, KTY81-110, Thermocouple, Resistor, Potentiometer, Voltage = 2-wire = 3-wire = 4-wire = For Thermocouple, Resistor, Potentiometer, Voltage At 0 mA (e.g. -200.0°C) At 20 mA (e.g.: +850.0°C) = = = = = C F V O P °C °F mV Ω % OUT01 OUT02 OUT03 OUT05 OUT13 OUT14 Thermocouples Resistance thermometers Sensor type 1) Standard Measuring (Input charac- range teristic curve) Smallest measuring range span PT... NI... Ni1000 CU10 CU50 CU53 KTY81 KTY84 DIN/SAMA -200°C ... 850°C DIN/SAMA -60°C ... 180°C Landis & Gyr -50°C ... 160°C SAMA -70°C ... 500°C – -50°C ... 200°C – -50°C ... 180°C Philips -55°C ... 150°C – -40°C ... 300°C Thermocouple Measuring range U T L J E K N S R B C W HK Cu-CuNi Cu-CuNi Fe-CuNi Fe-CuNi NiCr-CuNi NiCr-Ni NiCrSi-NiSi Pt10Rh-Pt Pt13Rh-Pt Pt30Rh-Pt6Rh -200°C ... -200°C ... -200°C ... -210°C ... -226°C ... -200°C ... -200°C ... -50°C ... -50°C ... 500°C ... -18°C ... -18°C ... -200°C ... Temperature ranges in accordance with IEC 60751/EN 60751 or DIN 43760 SAMA RC 21-4-1966 in 2, 3 or 4-wire technology. 1) Note: Pt sensors in increments of 10, 20, ...100 and 100, 200, ...1000, 2000. KTY81 = KTY81-110; KTY84 = KTY84-130. 2) 2) 2) 2) 2) 2) 2) 2) = = = = = = / 0...20 mA 4...20 mA 0...10 V 0...5 V -5...+5 V -10...+10 V N Factory calibration certificate / NONE N = Normal I = Inverse = Without certificate = With factory calibration certificate (fee) YESPLUS = Factory calibration certificate with 5 measuring points (fee) NONE YES Resistors, potentiometers, mV-voltages Sensor type 0.4 K 0.4 K 0.4 K 0.4 K 0.4 K 0.4 K 0.4 K 0.4 K Output characteristic curve Unit of mea- Output surement / C / OUT02 Measuring range: Start End / -200.0 / +850.0 Smallest measuring range span 600°C 400°C 900°C 1200°C 1000°C 1372°C 1300°C 1768°C 1768°C 1820°C 2316°C 2316°C 800°C Sensor type >1K >1K >1K >1K >1K >1K >1K >4K >4K > 10 K >4K >4K >1K Input Measuring range Smallest measuring range span RES Resistance 0 Ω ... 8000 Ω (2-wire) POT Potentiometers (max. 8 kΩ) 0 ... 100% (3-wire) 0.2% V01 Voltage -20 mV ...+2400 mV 2 mV 2Ω Conversion aid for temperature from °C to °F: 9 T [°F] = – T [°C] + 32 5 2) Thermocouples as per IEC 60584/EN 60584. Further types and characteristic curves on request. Further types and characteristic curves on request. Order examples with various input versions: Resistance thermometers 2814113 / PT100 / D / 3 / -200.0 / +850.0 / C / OUT02 / N / NONE (Configuration for 3-conductor PT 100 sensor; according to DIN from -200.0°C to +850.0°C with a 4...20 mA output characteristic) Thermocouple 2814113 / J / 0 / 0 / -346 / +2192 / F / OUT02 / I / NONE / OUT03 / I / NONE / OUT05 / N / NONE OUT02 / N / NONE (Configuration for thermocouple type J from -346F to +2192F with 20...4 mA output characteristic curve) Voltage 2814113 / V01 / 0 / 0 / -10 / 1200 / V (Configuration for voltage input from -10 mV to +1200 mV with 10...0 V output characteristic curve) Resistance 2814113 / RES / 0 / 0 / 0 / 7500 / O (Configuration for connecting a resistor varying between 0 Ω and 7500 Ω. The output signal is 0...5 V.) (2-wire connection) Potentiometers 2814113 / (3-wire connection) POT / 0 / 0 / 10 / 90 / P / (Configuration for connecting a 3-conductor potentiometer, whereby 10… 90% of the range is used. The output signal is 4…20 mA) Application examples: Resistance thermometer: 2-conductor connection method Resistance thermometer: 3-wire connection method R L1 1 R, R L2 3 MCR-T-UI-E Mode Power 7 10 +24 V DC GND R L1 MCR-T-UI-E 1 R L2 9 12 OUT I GND R L3 Output: Current signals 0(4)...20 mA Application: • For short distances (< 10 m) The following should be paid attention to: • Cable resistances RL1 and RL2 are incorporated in the measurement result directly and falsify the result accordingly (example Pt 100. 0.385 Ω = 1 K). A compensation of ± 5% is possible. 10 8 2 Mode Power 3 +24 V DC GND 4 R L2 R L3 9 12 OUT U GND Thermocouple: Absolute temperature measurement 1 MCR-T-UI-E 10 11 2 3 Mode Power +24 V DC GND 9 12 SP Output: voltage signal 0...(5)10 V, ±(5)10 V Application: • For large distances between the PT 100 sensor and the MCR module (RL1, RL2, RL3 ≤ 25 Ω). The following should be paid attention to: • The value of all cable resistances must be exactly the same in order to balance out the sensor cable resistances (RL1 = RL2 = RL3) Potentiometer Resistance thermometer: 4-conductor connection method R L1 R L4 Output: Switching output Application; • For long distances between a PT 100 sensor and the MCR module and different cable resistances (RL1 ≠ RL2 ≠ RL3 ≠ RL4) The following should be paid attention to: • The cable resistance (RL2 + RL4) must not exceed a value of 50 Ω . Thermocouple: Differential temperature measurement R L1 1 MCR-T-UI-E 3 R L2 7 10 8 11 2 R Mode Power +24 V DC GND mV / TC 9 12 + - 1 MCR-T-UI-E Mode Power OUT I GND 7 10 8 11 2 +24 V DC GND 9 12 TC TC Application: • Connecting a thermocouple or an mV signal. Note: • Activate cold junction compensation for the device with thermocouple measurements. 1 + - MCR-T-UI-E 7 10 8 11 2 6 Mode Power +24 V DC GND 9 12 OUT I GND OUT I GND Application: • For short distances and slow changes! The following should be paid attention to: • Cable resistances RL1 and RL2 are incorporated in the measurement result directly and falsify the result accordingly. A compensation of ± 5% is possible. + - Application: • Differential temperature measurement using thermocouples. • Switch off the cold junction compensation of the device. Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com PHOENIX CONTACT 371 INTERFACE Analog MACX Analog / MCR Analog Configurable temperature transducer for Pt 100 FL Temperature 17,5 114,5 99 IN U,I OUT PT100 MCR-PT100-...(-DC) POWER Configurable temperature transducer for Pt 100, optionally with electrical isolation uPz Housing width 17.5 IN – Temperature range adjustable via DIP switch – ZERO/SPAN adjustment – Open circuit detection – Alternatively with galvanically isolated supply voltage 1 2 stranded [mm2] 0.2-2.5 0.2-2.5 Pluggable screw connection AWG 24-14 Screw M3 2810337 2810311 = MCR-PT100-U-DC 2810337 = MCR-PT100-I-DC 2810340 = MCR-PT100-U 2810353 = MCR-PT100-I 372 PHOENIX CONTACT 3 = 3-wire 4 = 4-wire OUT U/I 7 8 GND 1 9 = 4 = Shield 5 Shield 6 10 (+) 24VDC 11 GND 2 12 GND 2 Power MM Description Type Order No. MCR-PT100-U-DC MCR-PT100-I-DC MCR-PT100-U MCR-PT100-I 2810311 2810337 2810340 2810353 Output: 0..0.10 V Output: 0...(4)20 mA Output: 0...10 V, without electrical isolation Output: 0...(4)20 mA, without electrical isolation Technical data Input data Resistance thermometers Temperature range Sensor input current Output data Output signal Maximum output signal Load RB Output signal with open circuit General data Supply voltage UB Current consumption Transmission error, max. Temperature coefficient ZERO / SPAN adjustment Step response (10-90%) Test voltage power supply/signal Ambient temperature (operation) Housing material Conformance / approvals Conformity UL, USA / Canada Temperature range / TR01 TR02 TR03 TR04 TR05 TR06 TR07 TR08 = = = = = = = = Pcs. / Pkt. MCR temperature transducer, for Pt 100 temperature sensors with 2, 3, 4-wire technology with electrically isolated supply voltage TR05 -50...+50°C -50...+100°C -50...+150°C -50...+250°C 0...100°C 0...150°C 0...200°C 0...300°C Output / OUT02 OUT01 = 0...20 mA OUT02 = 4...20 mA With the devices: 2810311 MCR-PT100-U-DC 2810340 MCR-PT100-U The output signal is 0...10 V. No details are necessary. 1 1 1 1 Pt 100 (IEC 60751/EN 60751) : 2, 3, 4-wire 0°C ... 300°C (0 ... 100/150/200/300) / -50°C ... 250°C (-50 ... 50/100/150/250) Approx. 1 mA U output I output 0 ... 10 V 0 ... 20 mA / 4 ... 20 mA 15 V 30 mA ≥ 10 kΩ ≤ 500 Ω > 11 V > 22 mA ...-U-DC ...-I-DC ...-U ...-I 20 ... 30 V DC 20 ... 30 V DC 20 ... 30 V DC 20 ... 30 V DC 35 mA 60 mA 20 mA 45 mA ≤ 0.4% (of end value) ≤ 0.02%/K ± 5% / ± 5% 11 ms 750 V AC (50 Hz, 1 min.) -20°C ... 65°C Polyamide PA non-reinforced CE compliant cULus Order key MCR-PT100-...(-DC) (Standard configuration entered as example) Connection method / 3 2 = 2-wire U U 3 solid The MCR-PT100 temperature transducers convert the measured values of the Pt 100 sensors (IEC 60751/ EN 60751) into electrically standardized analog signals. The possible connection methods (2, 3 or 4-wire connection), the various temperature spans and the current outputs (0...20 or 4...20 mA) can be selected by means of DIP switches. The calibration potentiometers are accessible from the front and offer the additional possibility of undertaking a measuring section alignment (ZERO/SPAN). The desired configuration must be specified in the order (refer to the order key). If the customer order details are faulty or missing, the devices are supplied with the standard configuration (3-wire connection, 0...100°C, output signal 0...10 V or 4...20 mA). Order No. OUT Factory calibration certificate / NONE NONE = Without certificate YES = With factory calibration certificate (fee) YESPLUS = Factory calibration certificate with 5 measuring points (fee) Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com INTERFACE Analog MACX Analog / MCR Analog Temperature relay for Pt 100 99 Temperature 114,5 12,5 IN OUT PT100 MCR-SL-PT100-SP POWER SL Temperature relay for Pt 100 uPz Housing width 12.5 IN – Switching point in the temperature range from -100°C ... +700°C freely selectable – Changeover relay output – Electrical isolation – Adjustable switch hysteresis 1 solid Pluggable screw connection stranded [mm2] 0.2-2.5 0.2-2.5 Pt 100 AWG 24-14 GND 4 Description Technical data Input data Resistance thermometers Temperature range Sensor input current Switching output Contact type Contact material Max. switching current Operate delay time Off delay time Switching hysteresis General data Supply voltage UB Current consumption Linearity error Setting accuracy Temperature coefficient Test voltage, input/output/supply Ambient temperature (operation) Assembly Housing material Conformance / approvals Conformity UL, USA / Canada N L 1 8 6 M C R -S L -P T 1 0 0 -S P 5 ϑ 5 11 6 12 DC DC Type Order No. MCR-SL-PT100-SP 2814948 7 11 8 14 Pcs. / Pkt. MCR temperature relay, for Pt 100 in 2-wire system Error/status indicator 7 U 2 Screw M3 +24 VDC 3 The MCR-SL-PT100-SP temperature relay converts the measured values of the Pt 100 sensor (IEC 60751/ EN 60751) into binary switching signals. The sensor is supplied with a small current from the module. The resulting voltage drop is amplified in the module and linearized with a characteristic curve. The switching threshold is set internally by a rough preselection via DIP switches and by a fine adjustment via a potentiometer on the front. A high-quality PDT relay with gold layer is located on the output side. The device has adjustable open circuit behavior. To increase the process reliability, the relay module has electrical isolation to the sensor signal. OUT SETPOINT 1 Pt 100 (IEC 60751/EN 60751) : 2-wire -100°C ... 700°C Approx. 1 mA Relay output 1 PDT AgSnO, hard gold-plated 50 mA (for gold layer, 30 V AC/ 36 V DC) 2 A (in case of a destroyed gold layer, 250 V AC) Approx. 6 ms Approx. 200 ms Adjustable using DIP switches (0.5 K, 2 K, 3 K, 5 K) LED red (short circuit/wire break) / LED yellow (relay active) 20 V DC ... 30 V DC < 30 mA < 0.1% < 1%, Typ. < 0.5% < 0.01%/K, Typ. 0.005%/K 1.5 kV (50 Hz, 1 min.) -20°C ... 65°C Any Polyamide PA non-reinforced CE compliant cULus S P E R R O R 1 0 0 2 0 K 3 0 5 0 4 0 S E T P O IN T IN 2 3 2 4 V G N D + 2 4 V 1 4 Mains voltage Temperature monitoring of a heated medium Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com PHOENIX CONTACT 373 INTERFACE Analog MACX Analog / MCR Analog Programmable loop-powered temperature transducer 12,5 114,5 Temperature 99 FL IN I POWER OUT MCR-FL-T-LP-I Programmable loop-powered temperature transducer uPz Ex: U Housing width 12.5 IN – For resistance thermometers, thermocouples, resistance-type and voltage sensors – Freely programmable via MCR-PI-CONF-WIN solid Pluggable screw connection stranded [mm2] 0.2-2.5 0.2-2.5 AWG 24-14 374 PHOENIX CONTACT 1 2 Screw M3 C 5 OUT 1 D DC D DC A 4 Description Type Order No. MCR temperature transducer, loop-powered for resistance thermometers, thermocouples, resistance-type and voltage sensors MCR-FL-T-LP-I 2864561 Technical data Input data Resistance thermometers Resistor Voltage Output data Output signal Maximum output signal Load RB 1 4 ... 20 mA / 20 ... 4 mA ≤ 23 mA (Max (Vsupply -12 V) / 0.023 A (current output)) Output signal with open circuit Output signal with short circuit ≤ 3.6 mA or ≥ 21 mA (adjustable) ≤ 3.6 mA or ≥ 21 mA (adjustable, not for thermocouples) Measuring range overrange/underrange ≤ 20.5 mA / ≥ 3.8 mA (linear increase/decrease) Step response (10-90%) Pickup delay Test voltage input/output Degree of protection Ambient temperature (operation) Assembly Housing material Conformance / approvals Conformity UL, USA / Canada Pcs. / Pkt. Pt, Ni (100, 500, 1000); minimum measurement range 10 K : 2, 3, 4-wire B, C, D, E, J, K, L, N, R, S, T, U; minimum measurement range 50 K/500 K Resistance-type sensor from 10 Ω to 400 Ω and from 10 Ω to 2000 Ω; minimum measurement range 10 Ω/100 Ω -10 mV ... 100 mV (min. measurement range 5 mV) Thermocouple sensors General data Supply voltage UB Current consumption Transmission error 6 GND 1 3 + The universal PC-programmable temperature transducers convert temperature signals from resistance thermometers and thermocouples as well as from sensors with linear mV characteristic curves into analog 4...20 mA signals. On the output side, the temperature transducers are operated in a 4...20 mA current loop, which simultaneously provides the power supply for the modules, necessary for signal conversion. Failure data in the event of sensor break or sensor short-circuit, that can be set in acc. with NE 43, and a high degree of accuracy in the entire ambient temperature range are the distinguishing features of the electrically isolated measurement transducers. The devices are supplied in the standard configuration: Pt 100 sensor, 0...100°C measuring range, 3-wire connection. Using the MCR-PAC-T programming adapter and the MCR/PI-CONF-WIN configuration software, it is possible to implement client-specific measurement range settings, linearizations and characteristic curve adaptations, refer to page 389. OUT Resistance thermometers Thermocouple sensors Resistance-type sensors Voltage sensor 12 V DC ... 35 V DC < 3.5 mA 0.2 K (Pt 100, Ni 100), 0.5 K (Pt 500, Ni 500), 0.3 K (Pt 1000, Ni 1000) Type 0.5 K (K, J, T, E, L, U), 1.0 K (N, C, D), 2.0 K (S, B, R) ± 0.1 Ω (10...400 Ω), ± 1.5 Ω (10...2000 Ω) ± 20 µV (-10...100 mV) <2s 4s 2 kV (50 Hz, 1 min.) IP20 -40°C ... 85°C Any Polyamide PA non-reinforced CE compliant Class I, Div. 2, Groups A, B, C, D Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com INTERFACE Analog MACX Analog / MCR Analog Programmable loop-powered temperature transducer 99 Temperature 114,5 12,5 IN I PT100 POWER OUT MCR-SL-PT100-LP-I Programmable loop-powered temperature transducer SL uPz Ex: U Housing width 12.5 IN – For Pt 100 resistance thermometers – Freely programmable via MCR-PI-CONF-WIN OUT 1 solid The universal PC-programmable temperature transducers convert temperature signals from resistance thermometers into analog 4...20 mA signals. On the output side, the temperature transducers are operated in a 4...20 mA current loop, which simultaneously provides the power supply for the modules, necessary for signal conversion. Failure data in the event of sensor break or sensor short-circuit, that can be set in acc. with NE 43, and a high degree of accuracy in the entire ambient temperature range are the distinguishing features of the electrically isolated measurement transducers. The devices are supplied in the standard configuration: Pt 100 sensor, 0...100°C measuring range, 3-wire connection. Using the MCR-PAC-T programming adapter and the MCR/PI-CONF-WIN configuration software, it is possible to implement client-specific measurement range settings, linearizations and characteristic curve adaptations, refer to page 389. Pluggable screw connection stranded [mm2] 0.2-2.5 0.2-2.5 AWG 24-24 2 Screw M3 C 5 OUT 1 D DC D A DC 6 GND 1 3 4 Description Type Order No. MCR temperature transducer, loop-powered for Pt 100 resistance thermometer MCR-SL-PT100-LP-I 2864558 Technical data Input data Resistance thermometers Output data Output signal Maximum output signal Load RB 4 ... 20 mA / 20 ... 4 mA ≤ 23 mA (Max (Vsupply -12 V) / 0.023 A (current output)) Output signal with open circuit Output signal with short circuit Measuring range overrange/underrange ≤ 3.6 mA or ≥ 21 mA (adjustable) ≤ 3.6 mA or ≥ 21 mA (adjustable) ≤ 20.5 mA / ≥ 3.8 mA (linear increase/decrease) General data Supply voltage UB Current consumption Transmission error Step response (10-90%) Pickup delay Test voltage input/output Degree of protection Ambient temperature (operation) Assembly Housing material Conformance / approvals Conformity UL, USA / Canada Pcs. / Pkt. 1 Pt 100 ; minimum measurement range 10 K : 2, 3, 4-wire Resistance thermometers 12 V DC ... 35 V DC < 3.5 mA 0.2 K <2s 4s 2 kV (50 Hz, 1 min.) IP20 -40°C ... 85°C Any Polyamide PA non-reinforced CE compliant Class I, Div. 2, Groups A, B, C, D Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com PHOENIX CONTACT 375 INTERFACE Analog MACX Analog / MCR Analog Programmable loop-powered temperature head transmitters ∅44 ∅33 4 6 2 IN I 1 POWER OUT MCR-FL-HT-T-I Programmable loop-powered temperature transducer 21 Temperature ∅7 ∅5 5 3 FL uPz Ex: U Housing width IN – For resistance thermometers, thermocouples, resistance-type and voltage sensors – For mounting in the connecting head, form B – Freely programmable via MCR-PI-CONF-WIN PHOENIX CONTACT AWG 24-15 Screw M3 4 C 1 OUT 1 D DC D DC A 2 GND 1 5 6 The universal PC-programmable temperature transducers convert temperature signals from resistance thermometers and thermocouples as well as from sensors with linear mV characteristic curves into analog 4...20 mA signals. On the output side, the temperature transducers are operated in a 4...20 mA current loop, which simultaneously provides the power supply for the modules, necessary for signal conversion. Failure data in the event of sensor break or sensor short-circuit, that can be set in acc. with NE 43, and a high degree of accuracy in the entire ambient temperature range are the distinguishing features of the measurement transducers. The devices are supplied in the standard configuration: Pt 100 sensor, 0...100°C measuring range, 3-wire connection. Using the MCR-PAC-T programming adapter and the MCR/PI-CONF-WIN configuration software, it is possible to implement client-specific measurement range settings, linearizations and characteristic curve adaptations, refer to page 389. 376 3 solid Screw connection stranded [mm2] 0.2-1.75 0.2-1.75 OUT Description Type Order No. MCR-FL-HT-T-I 2864529 Pcs. / Pkt. MCR temperature head transmitters, loop-powered for resistance thermometers, thermocouples, resistance-type and voltage sensors Technical data Input data Resistance thermometers Pt, Ni (100, 500, 1000); minimum measurement range 10 K : 2, 3, 4-wire B, C, D, E, J, K, L, N, R, S, T, U; minimum measurement range 50 K/500 K Resistance-type sensor from 10 Ω to 400 Ω and from 10 Ω to 2000 Ω; minimum measurement range 10 Ω/100 Ω -10 mV ... 75 mV (min. measurement range 5 mV) Thermocouple sensors Resistor Voltage Output data Output signal Maximum output signal Load RB 4 ... 20 mA / 20 ... 4 mA ≤ 25 mA (Max (Vsupply - 8 V) / 0.025 A (current output)) Output signal with open circuit Output signal with short circuit ≤ 3.6 mA or ≥ 21 mA (adjustable) ≤ 3.6 mA or ≥ 21 mA (adjustable, not for thermocouples) Measuring range overrange/underrange ≤ 20.5 mA / ≥ 3.8 mA (linear increase/decrease) General data Supply voltage UB Current consumption Transmission error Step response (10-90%) Pickup delay Test voltage input/output Degree of protection Ambient temperature (operation) Assembly Housing material Conformance / approvals Conformity UL, USA / Canada 1 Resistance thermometers Thermocouple sensors Resistance-type sensors Voltage sensor 8 V DC ... 35 V DC < 3.5 mA 0.2 K (Pt 100, Ni 100), 0.5 K (Pt 500, Ni 500), 0.3 K (Pt 1000, Ni 1000) Type 0.5 K (K, J, T, E, L, U), 1.0 K (N, C, D), 2.0 K (S, B, R) ± 0.1 Ω (10...400 Ω), ± 1.5 Ω (10...2000 Ω) ± 20 µV (-10...100 mV) <2s 6s 2 kV (50 Hz, 1 min.) IP00, IP66 (integrated in the connecting head) -40°C ... 85°C Any Polycarbonate PC CE compliant Class I, Div. 2, Groups A, B, C, D Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com INTERFACE Analog MACX Analog / MCR Analog Programmable loop-powered temperature head transmitters ∅44 ∅33 4 I PT100 6 1 Temperature 2 ∅7 ∅5 5 3 IN POWER OUT MCR-SL-HT-PT 100-I Programmable loop-powered temperature transducer 21 SL uPz Ex: U Housing width IN – For Pt 100 resistance thermometers – For mounting in the connecting head, form B – Freely programmable via MCR-PI-CONF-WIN 3 solid Screw connection stranded [mm2] 0.2-1.75 0.2-1.75 OUT AWG 24-15 Screw M3 4 C 1 OUT 1 D DC D A DC 2 GND 1 5 The universal PC-programmable temperature transducers convert temperature signals from resistance thermometers into analog 4...20 mA signals. On the output side, the temperature transducers are operated in a 4...20 mA current loop, which simultaneously provides the power supply for the modules, necessary for signal conversion. Failure data in the event of sensor break or sensor short-circuit, that can be set in acc. with NE 43, and a high degree of accuracy in the entire ambient temperature range are the distinguishing features of the measurement transducers. The devices are supplied in the standard configuration: Pt 100 sensor, 0...100°C measuring range, 3-wire connection. Using the MCR-PAC-T programming adapter and the MCR/PI-CONF-WIN configuration software, it is possible to implement client-specific measurement range settings, linearizations and characteristic curve adaptations, refer to page 389. 6 Description Type Order No. MCR-SL-HT-PT 100-I 2864516 Pcs. / Pkt. MCR temperature measuring transducer, loop-powered for Pt 100 resistance thermometer Technical data Input data Resistance thermometers Output data Output signal Maximum output signal Load RB 4 ... 20 mA / 20 ... 4 mA ≤ 23 mA (Max (Vsupply - 10 V) / 0.023 A (current output)) Output signal with open circuit Output signal with short circuit Measuring range overrange/underrange ≤ 3.6 mA or ≥ 21 mA (adjustable) ≤ 3.6 mA or ≥ 21 mA (adjustable) ≤ 20.5 mA / ≥ 3.8 mA (linear increase/decrease) General data Supply voltage UB Current consumption Transmission error Step response (10-90%) Pickup delay Degree of protection Ambient temperature (operation) Assembly Housing material Conformance / approvals Conformity UL, USA / Canada 1 Pt 100 ; minimum measurement range 10 K : 2, 3, 4-wire Resistance thermometers 10 V DC ... 35 V DC < 3.5 mA 0.2 K <2s 4s IP00, IP54 (integrated in the connecting head) -40°C ... 85°C Any Polycarbonate PC CE compliant Class I, Div. 2, Groups A, B, C, D Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com PHOENIX CONTACT 377 INTERFACE Analog MACX Analog / MCR Analog Programmable frequency transducers FL U,I IN f,U,I 45 110 Conversion 75 OUT MCR-F-UI-DC POWER Programmable frequency transducer for frequencies up to 120 kHz uPFz Ex: U Housing width 45 – – – – Frequencies up to 120 kHz Analog and switching output 3-way isolation Programmable using membrane keypad or software – Display of input or output signal Pluggable screw connection stranded [mm2] 0.2-2.5 0.2-2.5 NPN PNP solid AWG 24-14 Screw M3 Dry Contact 1 2 +8,2 V 3 4 f in 5 6 NPN PNP +15 V DC DC Namur IN DC GND 1 mC A 0-10 V 7 U in 8 I in 0-20 mA D D The MCR-F-UI-DC programmable frequency transducer is a module for displaying and converting frequencies up to 120 kHz into analog standard signals. The transmission behavior of the frequency measuring transducer can be set on the front using the membrane keypad or the MCR/PI-CONF-WIN configuration software, refer to page 389. Either the input value for the measured frequency or the standard output signals can be read off on the front LC display. All common frequency generator signals with 2, 3 or 4-wire technology and the signals of incremental rotary transducers can be recorded on the input side, e.g.: – NAMUR sensors – Frequency generators – Floating contacts – NPN/PNP transistor outputs In addition, there is also a PNP transistor switching output with a maximum carrying capacity of 100 mA, for alarm processing, for example (not short-circuit proof). Description PHOENIX CONTACT 11 SW 12 GND 13 NC 14 I OUT A 15 16 U OUT GND 2 Type Order No. MCR-F-UI-DC 2814605 Pcs. / Pkt. MCR frequency measuring transducer, for conversion of frequencies into analog signals 0(4)...20 mA, 0...(5)10 V and their inverse signals Technical data Input data Frequency range Input sources Transducer supply Signal level Maximum input signal Signal form Pulse length Resolution Signal conversion time Input data Input signal (can be set freely) Maximum input signal Input resistance Resolution Step response (10-90%) Output data Output signal (normal and inverse) Maximum output signal Load RB Ripple Switching output General data Supply voltage UB Current consumption Transmission error, max. Temperature coefficient ZERO / SPAN adjustment Test voltage, input/output/supply Ambient temperature (operation) Status indication Operating elements Housing material Conformance / approvals Conformity UL, USA / Canada GL 378 D +24 V GND A D A 9 10 1 Frequency input 0.1 Hz ... 120 kHz NPN/PNP transistor outputs NAMUR initiators Floating relay contact (dry contact) Frequency generator Approx. 15 V DC / Max. 25 mA (constant) 2 VPP (In case of rectangle 0.1 Hz ... 120 kHz) 2 VPP (In case of sine 8 Hz ... 120 kHz) 13 VPP (In case of sine 1 Hz ... 120 kHz) 30 V (incl. DC voltage) Any ≥ 1 µs > 12 bit ≤ 32 ms Isolating amplifier function 0 ... 10 V 0 ... 20 mA 12 V 24 mA 95 kΩ 200 Ω 14 bit (full-scale) 14 bit (full-scale) < 25 ms < 25 ms U output I output 0 ... 5 V / 0 ... 10 V 0 ... 20 mA / 4 ... 20 mA 12.5 V 25 mA ≥ 500 Ω ≤ 500 Ω < 20 mVPP < 20 mVPP Transistor output, pnp Switches supply voltage to terminal block SW, can carry a load of 100 mA, not protected against short circuit 20 V DC ... 30 V DC < 60 mA (without load, without switching output) ≤ 0.15% (of measured value), Typ. 0.1% 0.015%/K, Typ. 0.01%/K ± 25% / ± 25% 1.5 kV (50 Hz, 1 min.) -20°C ... 65°C (for specified data) LC display Membrane keypad with 3 keys and LCD display ASA-PC (V0) CE compliant Class I, Div. 2, Groups A, B, C, D or non-hazardous locations Germanischer Lloyd Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com INTERFACE Analog MACX Analog / MCR Analog Connection examples for common frequency transmitters 7 U IN 8 I IN 8 I IN 8 I IN bu bk wh npn bk 4 GND1 NPN 5 PNP 6 +15 V 7 U IN 7 U IN 8 I IN 1 +8,2 V 2 NAMUR IN 3 f IN Incremental rotary transducer with push-pull: • Supply of the external signaling encoder UB = 5-30 V DC UB = 0 V DC 4 GND1 NPN 5 PNP 6 +15 V 4 GND1 NPN 5 PNP 6 +15 V UB = 24 V DC K1, K2, K0 K1, K2, K0 15 V/25 mA 1 +8,2 V 2 NAMUR IN 3 f IN 4 GND1 NPN 5 PNP 6 +15 V 1 +8,2 V 2 NAMUR IN 3 f IN 4 GND1 NPN 5 PNP 6 +15 V UB = 0 V 8 I IN • Supply of the signaling encoder from the module 15 V/25 mA The external supply can be picked off by terminal blocks 9 +24VDC and 0 GND as well. Any 3-way isolation then no longer applies. K1, K2, K0 K1, K2, K0 1 +8,2 V 2 NAMUR IN 3 f IN 4 GND1 NPN 5 PNP 6 +15 V 7 U IN 7 U IN 7 U IN 8 I IN 8 I IN 8 I IN Application examples: The frequency transducer MCR-F-UI-DC converts the pulse signal into an analog standard signal that provides information about the numbers of bottles in filling systems recorded in a defined time unit. For speed measurements, it is possible to enter the measuring range in revolutions per minute (rpm) and to display the current measured value on the device. The frequency measuring transducer has an automatic measuring range selection function (autorange) to ensure the best possible resolution. This permits response times to be reduced to a minimum and the measured value is optimally adapted to the input value. MCR-f-UI-DC 7 U IN 7 U IN • Supply of the signaling encoder from the module MCR-f-UI-DC bk 1 +8,2 V 2 NAMUR IN 3 f IN 1 +8,2 V 2 NAMUR IN 3 f IN Incremental rotary transducer with HTL logic: • Supply of the external signaling encoder 8 I IN • With NPN transistor output wh bn 4 GND1 NPN 5 PNP 6 +15 V 8 I IN 8 I IN npn bu 7 U IN 7 U IN bn bk 1 +8,2 V 2 NAMUR IN 3 f IN 8 I IN 4 GND1 NPN 5 PNP 6 +15 V bu 1 +8,2 V 2 NAMUR IN 3 f IN bn • NPN transistor with pull-up resistance MCR-f-UI-DC 1 +8,2 V 2 NAMUR IN 3 f IN • With NPN transistor output MCR-f-UI-DC pnp bn 4 GND1 NPN 5 PNP 6 +15 V 7 U IN 4-wire DC • With PNP transistor output bu bu 7 U IN 4 GND1 NPN 5 PNP 6 +15 V bn bk MCR-f-UI-DC 4 GND1 NPN 5 PNP 6 +15 V MCR-f-UI-DC bu bk 1 +8,2 V 2 NAMUR IN 3 f IN MCR-f-UI-DC pnp 2-wire DC NAMUR sensor bn 1 +8,2 V 2 NAMUR IN 3 f IN bu Application example: Flow measurement 1 2 3 4 NPN PNP Dry Contact 5 6 +8,2 V DC DC Namur IN F in 11 SW µC NPN PNP 0-10 V 7 8 12 GND 24 V 13 NC +15 V A 0-20 mA 9 +24 V 10 GND DC GND 1 NAMUR sensor MCR-f-UI-DC 4 GND1 NPN 5 PNP 6 +15 V Terminal block 1 also possible instead of terminal block 6. 3-wire DC • PNP transistor with pull-down resistance MCR-f-UI-DC 1 +8,2 V 2 NAMUR IN 3 f IN bn MCR-f-UI-DC bu 3-wire DC • With PNP transistor output MCR-f-UI-DC bn MCR-f-UI-DC 2-wire DC (mechanical contact) U in A D A I in 14 I OUT D Mains voltage 15 U OUT D A D 16 GND 2 Control system Application example: Measurement of revolutions of a drive 1 2 3 4 NPN PNP Dry Contact 5 6 +8,2 V DC DC Namur IN F in 11 SW GND 1 µC NPN PNP 0-10 V 7 8 12 GND 24 V 13 NC +15 V A 0-20 mA 9 +24 V 10 GND DC U in A D A I in 14 I OUT D 15 U OUT D D A Mains voltage 16 GND 2 NAMUR Actuated:≤ 1.2 mA Not actuated: ≥ 2.1 mA Control system Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com PHOENIX CONTACT 379 INTERFACE Analog MACX Analog / MCR Analog Programmable limit value switch 75 Control 110 FL 45 IN ,U,I,R OUT MCR-PSP-DC POWER Programmable threshold value switch for standard and temperature signals uP Housing width 45 – Four independently adjustable switching thresholds – With or without electrical isolation of input signals – Programmable using the MCR-PI-CONF-WIN software – Continuous measured value display The MCR-PSP threshold value switch is used to monitor and control processes. Four switching thresholds that can be adjusted independently of one another react to the signals of various thermocouple sensors, resistance thermometers and linear resistors that can be connected directly. An input for analog signals is provided to monitor process signals that have already been converted. Programming can be performed using either the membrane keypad or the configuration software MCR/PI-CONFWIN, refer to page 389. The LED display constantly displays the current measured value so that the process value can also be monitored visually. The two relays are designed as PDT contacts with adjustable time delay, and the limit values of each contact have a modifiable hysteresis. The relays can be set to pick up or drop out. The devices with electrically isolated inputs decouple the field level and supply, thus avoiding the creation of distributed measurement circuits. 380 PHOENIX CONTACT (+) 24 VDC 1 POWER 2 (-) GND - 9 0000 10 MM shield IN solid Pluggable screw connection stranded [mm2] 0.2-2.5 0.2-2.5 AWG 24-14 Screw M3 3 4 12 11 14 µC 5 A OUT 22 21 24 Description I (±) 12 U (±) 13 GND (±) 14 U (-) 15 U (+) 16 I 11 D 6 7 8 E Type Order No. MCR-PSP-DC MCR-PSP 2811925 2811912 Pcs. / Pkt. MCR threshold value switch, with two relay contacts With electrically isolated input Technical data Input data Input sources Measuring rate Input resistance Discontinuous control resolution Switching output Contact type Contact material Max. switching voltage Max. switching current Mechanical life Response delay Status indication General data Supply voltage UB Current consumption Transmission error, max. Temperature coefficient Test voltage input/power supply Ambient temperature (operation) Status indication Assembly Housing material Conformance / approvals Conformity UL, USA / Canada Current / voltage 1 1 Resistance thermometer 2, 3 or 4-wire system (in acc. with DIN 43760/DIN IEC 751 or SAMA RC 21-4-1966), e.g. PT sensors, Ni sensors etc. Thermocouple sensors (in acc. with DIN IEC 584-1/DIN 43710): B, E, J, K, L, N, R, S, T, U Resistance: 0 kΩ ... 8 kΩ (only 2-wire connection) Current: - 30 mA...+ 30 mA Voltage: - 30 V...+ 30 V 2 Hz 50 Ω / 200 kΩ 0,1°C / 0,01 V / 0,01 mA / 0,1 Ω 2 x PDT contact, / 2 switching points each, pick-up/drop-out (can be switched) AgNi 0,15 + HTV (hard gold-plated) 250 V AC 2 A AC 2 x 107 cycles 0 s ... 2 s (adjustable) LED display 20 V DC ... 30 V DC < 60 mA 0.1% (of end value) ≤ 0.01%/K 1 kV AC (50 Hz, 1 min.) -20°C ... 65°C 5-position 7-segment display and LEDs Any ABS CE compliant cULus Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com INTERFACE Analog MACX Analog / MCR Analog Limit value switches 75 45 108 Control FL IN U,I OUT MCR-2SP-UI-DC POWER Limit value switch with two isolated, adjustable relay outputs uPz Housing width 45 OUT1 IN – Two relay outputs – Two adjustable limit values – With electrical isolation of supply voltage The MCR-2SP-UI-DC threshold value switch monitors standard analog signals in the ranges 0...10 V and 0...20 mA. Limit values 1 and 2 can be set independently either using two decade switches on the front side or by specifying analog values. If the set switching thresholds are exceeded, two relays with PDT contacts are activated. The two relays can be set to either drop out or pick up (normally closed/normally open function) A time delay of up to four seconds can be selected (set) separately for each limit value with two potentiometers. The differential inputs allow several limit value switches to be connected in series in order to realize any number of limit values. (-) IN (+) IN 1 2 (-) 1 (+) SET POINT (-) 2 (+) POWER (-) GND (+) 24 VDC 3 4 1 5 6 2 11 12 12 11 solid Pluggable screw connection stranded [mm2] 0.2-2.5 0.2-2.5 AWG 24-14 Screw M3 Description 13 14 + 14 22 + 15 21 - 7 8 16 24 9 9 1 1 - OUT2 Type Order No. MCR-2SP-UI-DC 2769873 Pcs. / Pkt. MCR threshold value switch, with two separately adjustable relay contacts and electrically isolated supply Technical data Input data Input signal Maximum input signal Input resistance Limit value setting 1 U input I input 0 ... 10 V 0 ... 20 mA 13 V 100 mA 200 kΩ 50 Ω 2-figure momentary-contact coding switch (0 ... 99%) External analog value definition 2-figure momentary-contact coding switch (0 ... 99%) and external analog value definition Approx. 100 mV Approx. 200 µA Relay output 2 PDT contact, pick-up/drop-out (can be switched) Silver cadmium oxide (AgCdO) 250 V AC 3A 3 x 107 cycles 8 ms ... 4 s (adjustable) LED Internal hysteresis Switching output Contact type Contact material Max. switching voltage Max. switching current Mechanical life Response delay Status indication General data Supply voltage UB Current consumption Temperature coefficient Step response (10-90%) Test voltage input/power supply Ambient temperature (operation) Assembly Housing material Conformance / approvals Conformity UL, USA / Canada 20 V DC ... 30 V DC < 100 mA ≤ 0.01%/K 8 ms 1 kV AC (50 Hz, 1 min.) -20°C ... 65°C Any ABS CE compliant cULus Drive with speed torquesensor 1 - - + 1 + 0 2 POWER Monitoring and control of a mixing process 3 11 - - + 4 5 0 + 0...20 mA 12 5 0s MCR-2SP-UI-DC SETPOINT 1 TIME 1 8 0s 2/3-way valve 4s TIME 2 7 SETPOINT 2 4s 6 13 14 15 16 Control system M 24 V 24 V Mains voltage Mixing weight Mains voltage Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com PHOENIX CONTACT 381 INTERFACE Analog MACX Analog / MCR Analog Limit value switches 17,5 Control 114,5 99 IN U,I 3x OUT MCR-SWS-... SL POWER Limit value switch for standard signals uPz Housing width 17.5 OUT IN – – – – Relay/transistor output Limit indicator Adjustable hysteresis Monitoring of three signal statuses solid Pluggable screw connection The MCR-SWS threshold value switch is used to monitor simple automation processes. On the input side, 0...10 V or 0...20 mA standard analog signals are processed. The single-ended current input can be isolated using a jumper and therefore used as the differential current input. With the aid of the differential input, it is possible to connect several limit value switches in series in order to monitor a current value. A limit value is set in the module from the 0...10 V or 0(4)...20 mA analog input signals via a potentiometer. If the input signal reaches the threshold value, a relay PDT contact is actuated at the output. After the limit value has been set, the required hysteresis (setting point) can be set by means of another potentiometer. Both switching points affect a relay. For monitoring, the three signal range statuses (A, B, C) - below, in and above the hysteresis - are available as transistor outputs. LEDs indicate the three signal ranges. 382 PHOENIX CONTACT stranded [mm2] 0.2-2.5 0.2-2.5 AWG 24-14 Screw M3 IN I/U 1 GND 1 2 GND 1 3 12 11 14 0 A B C 4 5 6 IN 7 OUT A 8 OUT B 9 OUT C + 24VDC GND 2 12 GND 2 10 11 Description Type Order No. MCR threshold value switch, with adjustable hysteresis and relay/transistor output Input: 0..0.10 V Input: 0(4) - 20 mA MCR-SWS-U MCR-SWS-I 2766465 2766478 Technical data Input data Input signal Maximum input signal Input resistance Limit value setting Setting range of the limit value Setting range for the hysteresis Internal hysteresis Switching output Number of outputs Output voltage Continuous load current Switching output Contact type Contact material Max. switching voltage Max. switching current Mechanical life Status indication General data Supply voltage UB Current consumption Temperature coefficient Step response (10-90%) Ambient temperature (operation) Assembly Housing material Conformance / approvals Conformity UL, USA / Canada Pcs. / Pkt. 1 1 U input I input 0 ... 10 V 0 ... 20 mA / 4 ... 20 mA 11 V 22 mA ≥ 100 kΩ ≤ 120 Ω Setting potentiometer, scaled 270° potentiometer 0 V ... 10 V 0 A ... 20 mA 0.1 V ... 10 V (setting accuracy: ± 0.2 mA ... 20 mA (setting 30 mV) accuracy: ± 60 µA) ± 30 mV (around the lower/upper ± 60 µA (around the lower/upper switching point) switching point) Transistor output, pnp 3 20 V DC ... 30 V DC 100 mA Relay output 1 PDT AgNi 0,15 + HTV (hard gold-plated) 250 V AC (30 V DC) 2A 107 cycles LED 20 V DC ... 30 V DC 60 mA ≤ 0.02%/K < 25 ms -20°C ... 65°C Any Polyamide PA non-reinforced CE compliant cULus Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com INTERFACE Analog MACX Analog / MCR Analog Digital display Standard signals Pr1 1 Pr2 2 48 96 P 00000 U,I OUT POWER MCR-FL-D-U-I-2SP-... 83 IN max. 19 Control FL Programmable digital display for standard analog signals uP Housing width 96 – – – – – For standard analog signals Programmable 5 positions displayed Electrical isolation 2 relay outputs with freely selectable limit values – Totalisator – Display 96 x 48 mm The MCR-FL-D-UI-2SP-... digital displays in the Function Line visualize standard analog signals of 0...10 V and 0(4)...20 mA. On the output side, the devices provide two relay outputs with a freely adjustable hysteresis. The totalisator enables the addition of measured values and the total value display. Outstanding features of the digital display are the simple programmability of the totalisator, threshold values with hysteresis and up to 24 base points on the characteristic curve. It has a display value memory (latch/hold function) as well as an encoder supply for sensors. The scaling function offers the possibility of displaying standard analog signals in freely selectable physical measuring ranges (e.g. input signal 4. . .20 mA in the display range 0...150 l/min.) The displays are available with 24 V DC as well as with 230 V AC supply voltage. OUT X2 n.c. 11 10 VDC/30 mA 10 GND 3 9 solid Pluggable screw connection Pluggable screw connection stranded [mm2] 0.14-1 0.14-1.5 AWG 26-16 Screw M2 0.2-2.5 24-12 M3 0.2-2.5 RESET/LATCH GND 2 KEY n.c. n.c. U GND 1 IN I - - - - 8 7 6 5 4 3 2 1 µC A D X1 8 7 6 5 4 3 2 1 GND 4 +10...30 VDC 12 14 O UT 1 11 22 24 O UT 2 21 0000 Description Type Order No. MCR digital display, for measurement and display of standard signals Supply voltage 24 V DC Supply voltage 230 V AC MCR-FL-D-U-I-2SP- 24 MCR-FL-D-U-I-2SP-230 2864215 2864228 Technical data Input data Input signal Maximum input signal Input resistance Resolution Measuring rate Input latch signal Input reset impulse U input I input 0 ... 10 V / -10 ... 10 V 0 ... 20 mA / 4 ... 20 mA ± 30 V 50 mA > 1 MΩ < 50 Ω 1 mV 2 µA Approximately 2 measurements/second Display stop > 5 ms to reset the totalizer / the relay outputs Switching level Output data display Number of the displayed positions Precision Switching output Contact type Contact material Max. switching voltage Max. switching current Min. switching current Switching capacity Switching hysteresis Relay status display Supply voltage for measuring transducer/sensor General data Supply voltage UB Power consumption Data memory Resolution A/D System hum suppression Test voltage, input/output/supply Degree of protection Ambient temperature (operation) Control panel cutout Housing material Conformance / approvals Conformity UL, USA / Canada 1 signal ("H") 0 signal ("L") Pcs. / Pkt. 1 1 4 V DC ... 30 V DC 0 V DC ... 2 V DC 7-segment LED; 14.2 mm; red 5 < 0.1% ± 1 digit (At 20°C ambient temperature) MCR-FL-D-U-I-2SP- 24 MCR-FL-D-U-I-2SP-230 2 PDT 2 PDT AgCdO AgCdO 300 V DC / 250 V AC 300 V DC / 250 V AC 3A 3A 30 mA DC 30 mA DC 50 W / 2000 VA 50 W / 2000 VA Programmable Programmable LED reds LED reds 10 V DC ± 2%, 30 mA 10 V DC ± 2%, 30 mA 24 V DC ± 15%, 50 mA MCR-FL-D-U-I-2SP- 24 MCR-FL-D-U-I-2SP-230 10 ... 30 V DC 90 ... 260 V DC Max. 2 W Max. 6 VA EEPROM 1 mil. memory cycles or 10 years 14 Bit Digital filtering 50/60 Hz (500 Vrms / 2.3 kVrms, 50/60 Hz, 1 min.) IP65 from the front -20°C ... 65°C 92 (+0.8)x45(+0.6) mm Macrolon 2405 CE compliant UL 508 Recognized Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com PHOENIX CONTACT 383 INTERFACE Analog MACX Analog / MCR Analog Digital display Standard signals SL U,I 00000 OUT POWER MCR-SL-D-U-I 59 IN max. 19,3 Control 24 48 Programmable digital display for standard analog signals uP Housing width 48 – – – – – – 10 VDC/30 mA For standard analog signals Programmable 5 positions displayed Electrical isolation Min./Max. value saving Display 48 x 24 mm Screw connection PHOENIX CONTACT stranded [mm2] AWG 0.14-1.5 0.14-1.5 26-16 - GND 1 3 solid Screw M3 Description µC LATCH 4 IN The MCR-SL-D-UI digital display in the Standard Line with five displaying positions is used to display standard analog signals of 0...10 V and 0(4)...20 m. Measured values can be easily read on the high-resolution 8 mm high LED display. The self-explanatory programmability of the digital display offers the user enormous time-savings. The 24 V DC-supplied display in a 48 mm x 24 mm DIN format contains a min./max. value memory. The position of the decimal point can be freely programmed via the front keys. The scaling function offers the possibility of displaying standard analog signals in freely selectable physical measuring ranges (e.g. input signal 4...20 mA in the display range 0...150 l/min.). The digital display also has a latch/hold function for saving display values. 384 1 GND 1 2 I 5 GND 2 6 U 7 A D 0000 Type Order No. MCR-SL-D-U-I 2864011 Pcs. / Pkt. MCR digital display, for measurement and display of standard signals Technical data Input data Input signal Maximum input signal Input resistance Resolution Measuring rate Input latch signal Switching level Output data display Number of the displayed positions Precision General data Supply voltage UB Current consumption Data memory Resolution A/D System hum suppression Test voltage input/power supply Degree of protection Ambient temperature (operation) Control panel cutout Housing material Conformance / approvals Conformity UL, USA / Canada U input 0 ... 10 V 30 V DC > 1 MΩ 1 signal ("H") 0 signal ("L") I input 0 ... 20 mA / 4 ... 20 mA 50 mA (approx. 100 Ω with 5 mA / approx. 70 Ω with 20 mA) 1 mV 2 µA Approximately 2 measurements/second Display stop 4 V DC ... 30 V DC 0 V DC ... 2 V DC 7-segment LED; 8 mm; red 5 < 0.1% ± 1 digit (At 20°C ambient temperature) 10 V DC ... 30 V DC 50 mA EEPROM 1 mil. memory cycles or 10 years 14 Bit Digital filtering 50/60 Hz 500 Vrms (50/60 Hz, 1 min.) IP65 from the front -10°C ... 50°C 22(+0.6)x45(+0.8) mm Macrolon 2405 CE compliant UL 508 Recognized Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com 1 INTERFACE Analog MACX Analog / MCR Analog Digital display Frequencies, pulses, times 24 48 OUT t SL POWER MCR-SL-D-FIT 59 IN max.19,3 Control 000000 f Programmable digital display for frequencies, pulses and times u Housing width 48 – – – – – +10...30V DC 0V / GND fin For frequencies, pulses and times Programmable Data saving with Power Off 6 positions displayed Display 48 x 24 mm 1 2 - µC - IN solid Pluggable screw connection stranded [mm2] 0.14-1 0.14-1.5 AWG 26-16 Screw M3 OUT The Standard Line digital display MCR SL-D-fit with six display positions is used to display frequencies, pulses and times. The required function can be configured quickly and easily via the two front buttons. Measured values can be easily read on the high-resolution 8 mm high LED display. The self-explanatory programmability of the digital display offers the user enormous time-savings. The 24 V DC-supplied display in a 48 mm x 24 mm DIN format saves the data if the supply voltage fails. The position of the decimal point is freely selectable. The digital display also has an optocoupler NPN transistor output that can be used, among other things, for counting applications and is activated in the "zero" position. Description INP A / fin INP B 3 SET / RESET 5 EMITTER 6 COLLECTOR 7 f CNT t 4 000000 Type Order No. MCR-SL-D-FIT 2864024 Pcs. / Pkt. MCR digital display, for measurement and display of frequencies, pulses and times Technical data Input data Signal input Max. 60 kHz (CntDir) Max. 25 kHz (UpDown / Up.Up/Quad 1/ Quad 2) Max. 15 kHz ((Quad 4)) Setting function at setting value or zero Min. 5 µs NPN/PNP transistor outputs, floating relay contacts Reset input Pulse time Input sources Polarity Standard switching level Switching level (5 V) Input resistance Impulse form Output data display Number of the displayed positions Accuracy of tacho / frequency counter Timer accuracy Switching output Max. switching voltage Max. switching current Pulse counter function Accuracy of tacho / frequency counter function Timer function General data Supply voltage UB Current consumption Data memory Degree of protection Ambient temperature (operation) Control panel cutout Housing material Conformance / approvals Conformity UL, USA / Canada 1 1 signal ("H") 0 signal ("L") 1 signal ("H") 0 signal ("L") Can be programmed jointly for all inputs 0.6 X U B ... 30 V DC 0 V DC ... 0.2 X UB 4 V DC ... 30 V DC 0 V DC ... 2 V DC 10 kΩ Any (Schmitt trigger input), rectangular pulse 1:1 at maximum frequency 7-segment LED; 8 mm; red 6 < 0.1% < 0.005% 30 V DC 10 mA Active, at counter reading ≤ 0 active, at f = 0 1 Hz frequency, with active time measurement 10 V DC ... 30 V DC Max. 40 mA EEPROM 1 mil. memory cycles or 10 years IP65 from the front -20°C ... 65°C 22(+0.6)x45(+0.8) mm Macrolon 2405 CE compliant UL 508 Recognized Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com PHOENIX CONTACT 385 INTERFACE Analog MACX Analog / MCR Analog Digital display Setpoint adjuster SL 0000 Uref Iref OUT POWER MCR-SL-D-SPA-UI 59 IN max.19,3 Control 24 48 Setpoint adjuster with manual and automatic ramp function u Housing width 48 – Manual setpoint definition with step width setting – Manual setpoint definition via direct input – Automatic setpoint definition with hold function and 20 support points – Free presetting of signals in the range of 0...12 V or 0...24 mA – Data backup in case of a power failure – Display value parameterization – Electrical isolation between output and supply In test and control systems, setpoints are often required for manual operation of systems without sensor signals. The MCR-SL-D-SPAUI setpoint adjuster provides several solutions here. Three setpoint definition modes selectable via programming enable flexible adaptation to your application. Setpoints can be signaled manually as well as automatically via 20 support points. The flexibly adjustable signal range of 0...12 V or 0...24 mA also provides a suitable setpoint definition for every application in one device. Each display value can be assigned to the particular output signal. 386 PHOENIX CONTACT 1 GND 1 2 HOLD 4 GND 2 3 solid Pluggable screw connection stranded [mm2] AWG 0.14-1.5 0.14-1.5 26-16 +10...30 V Screw M3 DC DC 7 µC 6 IN Description D 0000 A 5 Type Order No. MCR-SL-D-SPA-UI 2710314 0...12 V U OUT GND 3 I OUT 0...24 mA Pcs. / Pkt. MCR digital setpoint adjuster, for presetting current and voltage signals Technical data Input data display Number of the displayed positions Switching level, Hold Output data Output signal Length of step Load RB Ripple General data Supply voltage UB Power consumption Transmission error, max. Temperature coefficient Test voltage output/power supply Degree of protection Ambient temperature (operation) Control panel cutout Housing material Conformance / approvals Conformity UL, USA / Canada 1 signal ("H") 0 signal ("L") 7-segment, 8 mm, red 4 4 V DC ... 30 V DC 0 V DC ... 2 V DC I output 0 ... 24 mA 10 µA ≤ 500 Ω (Up to 20 mA) ≤ 10 mVPP U output 0 ... 12 V 10 mV ≥ 2 kΩ ≤ 10 mVPP 10 V DC ... 30 V DC 1 W (With 24 mA/12 V) < 0.2% ((full-scale) at rated voltage) 0.02%/K 500 V AC (50 Hz, 1 min.) IP65 from the front -20°C ... 65°C 45(+0.6)x22.2(+0.3) mm Macrolon 2405 CE compliant UL 508 Recognized Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com 1 INTERFACE Analog MACX Analog / MCR Analog DIN rail adapter for digital displays in a 24 x 48 mm housing – For digital displays in DIN format 24 x 48 mm – For mounting digital displays on 35 mm DIN rails in acc. with EN 60715 – No tools necessary for mounting The DIN rail adapter MCR-SL-D-RA makes it possible to fix DIN format 24 x 48 mm digital displays on conventional DIN rails acc. to EN 60715. All digital displays can be adapted quickly and easily. The mounting material required is enclosed with the digital display and tools are not necessary. Just push in the digital display and snap it on the DIN rail - done! Time-consuming marking, drilling and filing are eliminated. MCR-SL-D-RA Description Type Order No. MCR-SL-D-RA 2810081 Pcs. / Pkt. MCR DIN rail adapter for digital displays in a 24 x 48 mm housing Technical data General data Mounting position Housing material Dimensions W / H / D 1 Any PA-F 70 / 83.5 / 101 mm Setpoint value potentiometer 30 68 75 Control Uref IN OUT EMG 30-SP-...LIN U SL Description Type Order No. Pcs. / Pkt. EMG 30-SP- 4K7LIN EMG 30-SP/10K LIN 2940252 2942124 10 10 Setpoint potentiometer to set setpoints individually Resistance value 4.7 kΩ Resistance value 10 kΩ The EMG 30-SP setpoint modules make it possible to specify setpoints directly using standard potentiometers. Technical data Input data Resistance value Linearity Load capacity General data Ambient temperature (operation) Assembly Housing material Connection data solid / stranded / AWG Conformance / approvals Conformity EMG 30-SP- 4K7LIN 4.7 kΩ ±20% 5% (of end value) 1W EMG 30-SP/10K LIN 10 kΩ ±20% 5% (of end value) 0.5 W 0°C ... 40°C Any Polycarbonate fiber reinforced PC-F 0.2 ... 4 mm² / 0.2 ... 2.5 mm² / 24 - 14 CE compliant Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com PHOENIX CONTACT 387 INTERFACE Analog MACX Analog / MCR Analog Constant voltage source Control POWER IN 12,5 114,5 99 OUT MCR-PS- 24DC-10DC Uref Constant voltage source for 10 V DC with short-circuit proof output SL P Width 12.5 mm OUT The MCR-PS-24 DC-10 DC constant voltage source provides a high precision reference voltage of 10 V. These modules are often required in industrial processes in combination with potentiometers for selecting setpoints. Connection data Input Output stranded [mm2] AWG 0.2-2.5 0.2-2.5 24-14 0.2-2.5 0.2-2.5 24-14 + 10VDC GND 5 6 U REF solid M3 7 8 + 24VDC GND IN Description Type Order No. MCR constant voltage source Output voltage + 10 V DC MCR-PS- 24DC-10DC 2766685 Technical data Input data Input nominal voltage range Current consumption Output data Nominal output voltage Short-circuit current Ripple General data Ambient temperature (operation) Installation position Type of housing Temperature coefficient Conformance / approvals Conformity 388 PHOENIX CONTACT 18 V DC ... 30 V DC Approx. 10 mA (with no load on the output) + 10 V DC ±0,1% Approx. 65 mA ≤ 50 mVPP -20°C ... 65°C Any Polyamide PA non-reinforced, color: green ≤ 0.015%/K CE compliant Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com Pcs. / Pkt. 1 INTERFACE Analog MACX Analog / MCR Analog Configuration software package – Temperature transducers MCR-T-..., MCR-...-LP-... and MCR-...-HT-... – Current transducer MCR-S-... – Frequency converter MCR-f-UI-DC – Limit value switch MCR-PSP-... The MCR/PI-CONF-WIN configuration software package is used to configure and visualize all parameters for the programmable MCR measuring transducers. Thanks to the convenient menu interfaces, programmers do not have to spend a long time studying the manual before they start work. The computer and the measuring transducer communicate with one another via a software adapter cable and a serial interface. The software runs under the following operating systems: Windows 95™, 98™, ME™, NT™, 2000™ and XP™. MCR/PI-CONF-WIN Description Pcs. / Pkt. Type Order No. MCR/PI-CONF-WIN 2814799 1 MCR-ET 38X35 WH 2814317 1 MCR configuration software, for programming the MCR-T-..., MCR-...-LP-..., MCR-...-HT-..., MCR-S-..., MCR-f-..., MCR-PSP-..., modules, CD-ROM Labels, for labeling MCR-T and MCR-S modules, four sheets DIN A4 marking labels (112 pieces.) USB adapter cable Software adapter cable For connecting the programmable MCR-/PI modules to the USB interface of a computer, the USB adapter cable CM-KBL-RS232/USB can be used together with the relevant adapter cables. Programming with the MCR/PI-CONFWIN software is possible under the operating systems Windows 98™, Windows 2000™ and Windows XP™. The following modules are supported: – MCR-T-UI(-E)... – MCR-S-1-5-UI(-SW)-DCI... – MCR-f-UI-DC – MCR-PSP(-DC) – MCR-FL-T-LP-I – MCR-SL-PT100-LP-I – MCR-FL-HT-T-I – MCR-SL-HT-PT100-I CM-KBL... Description Pcs. / Pkt. Type Order No. CM-KBL-RS232/USB 2881078 1 Software adapter cable (Stereo jack connector/SUB-D 25-pos.), 1.2 m length, for programming MCR-T..., MCR-S... and MCR-f... modules MCR-TTL-RS232-E 2814388 1 Software adapter cable (6-pos./SUB-D 25-pos.), 1.5 m length, for programming MCR-PSP modules MCR-TTL-RS232 2814391 1 Software adapter cable (Stereo jack connector/SUB-D 9-pos.), 1.6 m length, in X II (1) GD [EEx ia] IIC for programming PI-EXRTD... and PI-EX-THC... modules PI-EX-TTL/RS232 2835312 1 Software adapter cable, 2.4 m length, for programming MCR...LP... and MCR...HT... modules MCR-PAC-T 2864590 1 Adapter cable, flexible, 9-pos. SUB-D socket on 25-pos. SUB-D pin PSM-KAD 9 SUB 25/BS 2761295 1 USB adapter cable, D-9-SUB to USB, with adapter D-9-SUB to D-25-SUB Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com PHOENIX CONTACT 389 INTERFACE Analog MACX Analog / MCR Analog Active current transducer up to 11 A, programmable and configurable 22,5 114,5 99 Power FL IN I U,I OUT MCR-S-1-5-UI(-SW)-DCI POWER Active current transducers, programmable and configurable uP Ex: U Housing width 22.5 8 IN solid Screw connection stranded [mm2] 0.2-2.5 0.2-2.5 AWG 24-14 Screw M3 12 1 11 2 14 3 The MCR-S-1-5-UI(-SW)-DCI current transducers record direct, alternating and distorted currents. The MCR-S-1-5-UI(-SW)-DCI module provides not only the standardized 1 A and 5 A input signals, but also the option of setting current ranges of 0...0.2 A to 0...11 A progressively. In addition to an analog output, these current transducers also have an optional transistor and relay output for alarm triggering for example. You also have the option of ordering a pre-configured device, of carrying out the configuration yourself using the DIP switch, or of programming using the MCR/PICONF-WIN configuration software, refer to page 389. The desired configuration must be specified when ordering pre-configured modules (refer to the order key). If specifications are incorrect or missing, the devices will be supplied with the standard configuration. NC 4 OUT Description Order configuration Standard configuration Order configuration, without switching output Standard configuration, without switching output Technical data Input data Input current Operate threshold Frequency range Curve type Overload capacity Surge strength Connection method Output data Output signal (normal and inverse) I DAC U Po wer = 9 O UT I 10 O UT U 11 GND 2 12 GND 2 13 24VDC 14 GND 1 15 SW 16 GND 1 Type Order No. MCR-S-1-5-UI-SW-DCI MCR-S-1-5-UI-SW-DCI-NC MCR-S-1-5-UI-DCI MCR-S-1-5-UI-DCI-NC 2814650 2814731 2814634 2814715 Load RB Switching output Relay output Transistor output pnp 0 A ... 11 A (AC/DC) (2% of measuring range nominal value 1/5/10 A) 15 Hz ... 400 Hz AC, DC or distorted currents 2 x IN (continuous) 20 x IN (1 s) Screw connection U output I output 0 ... 5 V / 1 ... 5 V / 0 ... 10 V 0 ... 20 mA / 4 ... 20 mA 2 ... 10 V / -5 ... 5 V / -10 ... 10 V > 10 kΩ < 500 Ω Contact material Max. switching current Output voltage Continuous load current Setting range of the threshold value Response delay Status indication General data Supply voltage UB Current consumption Transmission error, max. Temperature coefficient Step response (10-90%) Safe isolation Rated insulation voltage PHOENIX CONTACT OUT DAC µC Pcs. / Pkt. MCR current transducer for measuring AC, DC, and distorted currents with relay and transistor switching output Surge voltage category / pollution degree Test voltage input/output Test voltage input/power supply Test voltage output/power supply Degree of protection Ambient temperature range Housing material Conformance / approvals Conformity UL, USA / Canada 390 ADC SPAN – Progressive adjustment of measuring range – True r.m.s. value measurement – 3-way isolation – With optional relay and transistor output 5 6 7 SET TIME POINT ZERO 10A 5A 1A 1 PDT / AgSnO, hard gold-plated 50 mA (for gold layer, 30 V AC/ 36 V DC) 2 A (in case of a destroyed gold layer, 250 V AC) 19 V ... 29 V (supply voltage - 1 V) 80 mA (not short-circuit proof) 1% ... 110% 0.1 s ... 20 s LED yellow 20 V DC ... 30 V DC < 50 mA (without load) < 0.5% (of range nominal value under nominal conditions) Typ. < 0.025%/K 330 ms (with AC) as per EN 50178, EN 61010 300 V AC (to earth) III / 2 4 kV (50 Hz, 1 min.) 4 kV (50 Hz, 1 min.) 500 V (50 Hz, 1 min.) IP20 -20°C ... 60°C Polyamide PA non-reinforced CE compliant Class I, Zone 2, AEx nC IIC T6, Ex nC IIC T6 Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com 1 1 1 1 INTERFACE Analog MACX Analog / MCR Analog Active current transducer up to 55 A, programmable and configurable 22,5 114,5 99 Power FL IN I U,I OUT MCR-S-10-50-UI(-SW)-DCI POWER Active current transducers, programmable and configurable uP Ex: U Housing width 22.5 ADC IN SPAN solid Screw connection stranded [mm2] 0.2-2.5 0.2-2.5 AWG 24-14 Screw M3 12 1 11 2 14 3 The MCR-S-10-50-UI(-SW)-DCI current transducers record direct, alternating and distorted currents. Higher motor currents can also be measured in case of the measuring ranges, 0...9.5 A to 0...55 A. In addition to an analog output, these current transducers also have an optional transistor and relay output for alarm triggering for example. You also have the option to ordering a pre-configured device, of carrying out the configuration yourself using the DIP switch or of programming using the MCR/PICONF-WIN configuration software, refer to page 389. The desired configuration must be specified when ordering pre-configured modules (refer to the order key). If specifications are incorrect or missing, the devices will be supplied with the standard configuration. NC 4 OUT Description SET TIME POINT ZERO – Progressive adjustment of measuring range – True r.m.s. value measurement – 3-way isolation – With optional relay and transistor output OUT DAC µC I 9 O UT I 10 O UT U DAC 11 GND 2 12 GND 2 U Po wer 13 24VDC 14 GND 1 = 15 SW 16 GND 1 Type Order No. MCR-S-10-50-UI-SW-DCI MCR-S10-50-UI-SW-DCI-NC MCR-S-10-50-UI-DCI MCR-S10-50-UI-DCI-NC 2814663 2814744 2814647 2814728 Pcs. / Pkt. MCR current transducer for measuring AC, DC, and distorted currents with relay and transistor switching output Order configuration Standard configuration Order configuration, without switching output Standard configuration, without switching output Technical data Input data Input current Operate threshold Frequency range Curve type Overload capacity Surge strength Connection method Output data Output signal (normal and inverse) Load RB Switching output Relay output Transistor output pnp 0 A ... 55 A (AC/DC) (0.8% of measuring range nominal value 50 A) 15 Hz ... 400 Hz AC, DC or distorted currents Depending on through connected conductor Depending on through connected conductor Through connection, diameter 10.5 mm U output I output 0 ... 5 V / 1 ... 5 V / 0 ... 10 V 0 ... 20 mA / 4 ... 20 mA 2 ... 10 V / -5 ... 5 V / -10 ... 10 V > 10 kΩ < 500 Ω Contact material Max. switching current Output voltage Continuous load current Setting range of the threshold value Response delay Status indication General data Supply voltage UB Current consumption Transmission error, max. Temperature coefficient Step response (10-90%) Safe isolation Rated insulation voltage Surge voltage category / pollution degree Test voltage input/output Test voltage input/power supply Test voltage output/power supply Degree of protection Ambient temperature range Housing material Conformance / approvals Conformity UL, USA / Canada 1 1 1 1 1 PDT / AgSnO, hard gold-plated 50 mA (for gold layer, 30 V AC/ 36 V DC) 2 A (in case of a destroyed gold layer, 250 V AC) 19 V ... 29 V (supply voltage - 1 V) 80 mA (not short-circuit proof) 1% ... 110% 0.1 s ... 20 s LED yellow 20 V DC ... 30 V DC < 50 mA (without load) < 0.5% (of range nominal value under nominal conditions) Typ. < 0.025%/K 330 ms (with AC) 40 ms (with DC) as per EN 50178, EN 61010 300 V AC (to earth) III / 2 4 kV (50 Hz, 1 min.) 4 kV (50 Hz, 1 min.) 500 V (50 Hz, 1 min.) IP20 -20°C ... 60°C Polyamide PA non-reinforced CE compliant Class I, Zone 2, AEx nC IIC T6, Ex nC IIC T6 Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com PHOENIX CONTACT 391 INTERFACE Analog MACX Analog / MCR Analog Order key for the current transducers (Standard configuration entered as example) Order No. 2814634 2814650 Measuring range: Start End / 0.00 / 5.00 / OUT01 / 5.00 / OUT01 2814634 = MCR-S-1-5-UI-DCI 2814650 = MCR-S-1-5-UI-SW-DCI Order No. 2814647 2814663 0.00 Output / Measuring range starting value is between 0.00…7.50 A Measuring range final value between 0.2...11 A 0.00 = 0.00 A 5.00 = 5.00 A OUT01 OUT02 OUT03 OUT04 OUT05 OUT06 OUT07 OUT08 OUT09 OUT10 OUT11 OUT12 OUT13 OUT14 OUT17 OUT18 Measuring range: Start End / 0.0 / 50.0 / / 50.0 / 2814647 = MCR-S-10-50-UI-DCI 2814663 = MCR-S-10-50-UI-SW-DCI 0.0 Threshold value = = = = = = = = = = = = = = = = / 0...20 mA 4...20 mA 0...10 V 2...10 V 0...5 V 1...5 V 20...0 mA 20...4 mA 10...0 V 10...2V 5...0 V 5...1 V -5...+5 V -10...+10 V +10...-10 V +5...-5 V Output / Measuring range start value is between 0.00…37.5 A Measuring range final value between 9.5...55 A 0.0 = 0.0 A 50.0 = 50.0 A 50 Suppression time Operating behavior of relay and transistor / 3.0 Switching threshold between 1 ... 110% between 0.1 ... 20 s 50 = 50% of set upper measuring range value (here: 2.5 A) 3.0 = 3 s Threshold value / A / O A = Operating current controlled O = Overrange R = Closed-circuit current controlled U = Underrange Suppression time Operating behavior and Transistor OUT01 OUT01 OUT01 OUT02 OUT03 OUT04 OUT05 OUT06 OUT07 OUT08 OUT09 OUT10 OUT11 OUT12 OUT13 OUT14 OUT17 OUT18 = = = = = = = = = = = = = = = = 0...20 mA 4...20 mA 0...10 V 2...10 V 0...5 V 1...5 V 20...0 mA 20...4 mA 10...0 V 10...2V 5...0 V 5...1 V -5...+5 V -10...+10 V +10...-10 V +5...-5 V / 50 / 3.0 Switching threshold between 1 ... 110% between 0.1 ... 20 s 50 = 50% of set upper measuring range value (here: 25 A) 3.0 = 3 s / A / O A = Operating current controlled O = Overrange R = Closed-circuit current controlled U = Underrange Function diagrams: Switching behavior of relay and transistor output: 1) Operating current-controlled when threshold value is exceeded 2) Operating current-controlled when threshold value is underrun I IN IIN SW condition SW condition t ( H) Operating voltage UB t ( H) Operating voltage UB ( L) ( L) t (1) Relay N/O contact and transistor output (0) t1 Relay N/O contact and transistor output t1 (0) t1 t (0) Relay N/C contact t (1) t (0) t1 t1 t Relay N/C contact t1 3) Quiescent current-controlled when above threshold value 4) Quiescent current-controlled when below the threshold value IIN IIN SW condition SW condition t Operating voltage UB ( H) t Operating voltage UB ( H) ( L) ( L) t (1) Relay N/O contact and transistor output (0) t (1) t1 Relay N/O contact and transistor output t1 t t1 t1 (1) t (0) Relay N/C contact t t1 (1) (0) = N/O contact and transistor open / N/C contact closed (1) = N/O contact and transistor closed / N/C contact open PHOENIX CONTACT t1 (0) (0) Relay N/C contact 392 t (1) (1) Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com t INTERFACE Analog MACX Analog / MCR Analog Current transducers for sinusoidal alternating currents 0...1 A /0...5 A 22,5 7 114,5 104 Power IN I I OUT MACX MCR-SL-CAC-5-I(-UP) SL POWER Current transducers for sinusoidal alternating currents u Housing width 22.5 Ex: X // Applied for: UL-EX LIS / CUL-EX LIS OUT L(+) 1.1 – Wide-range version from 19.2...253 V AC/DC – 24 V DC version with additional supply options through a DIN rail connector – 3-way isolation – Input/output can be configured using the DIP switch – Operating state signaling through LED The MACX MCR-SL-CAC-5-I(-UP) current transducers convert sinusoidal alternating currents of 1 A or 5 A into standard analog signals 0...20 mA or 4...20 mA. Two versions are available: – MACX MCR-SL-CAC-5-I-UP as a wide-range version of 19.2...253 V AC/DC. – MACX MCR-SL-CAC-5-I as a 24 V DC version of 19.2...30 V DC. In this version, easy and quick power supply through the DIN rail connector is possible. AWG 24-14 24V A 1 Mains voltage Current measurement 3.2 GND N(-) 1.4 3.3 GND 3.4 GND 4.1 1A 4.2 5A 4.3 NC IN Type Order No. Pcs. / Pkt. Supply voltage 19.2 V DC ... 30 V DC Supply voltage 19.2 V AC/DC ... 253 V AC/DC DIN rail connector, for bridging the supply voltage (19.2...30 V DC), can be snapped on to 35 mm DIN rails as per EN 60715 MACX MCR-SL-CAC-5-I MACX MCR-SL-CAC-5-I-UP ME 22,5 TBUS 1,5/ 5-ST-3,81 GN 2810612 2810625 2707437 1 1 50 System power supply unit, primary-switched (not for zone 2) More information is given in the INTERFACE Power Supply catalog part. DIN rail connector, for bridging the supply voltage, can be snapped onto 35 mm DIN rails as per EN 60715, with UL approval, two pieces are required per system power supply MINI-SYS-PS-100-240AC/24DC/1.5 2866983 1 ME 17,5 TBUS 1,5/ 5-ST-3,81 GN 2709561 10 Description MCR current transducers for sinusoidal alternating currents Technical data Input data Input current (configurable) 0 A AC ... 1 A AC (configurable) / 0 A AC ... 5 A AC (configurable) 50 Hz 45 Hz ... 65 Hz Sine 2 x IN (continuous) 20 x IN (1 s) Screw terminal block Rated insulation voltage 0 00 1.3 4.4 Temperature coefficient Step response (10-90%) Safe isolation 5A OUT1 N(-) Screw M3 Nominal frequency Frequency range Curve type Overload capacity Surge strength Connection method Output data Output signal (configurable) Maximum output signal Load RB Ripple General data Supply voltage UB Current consumption Transmission error, max. 0...20mA 3.1 solid Screw connection stranded [mm2] 0.2-2.5 0.2-2.5 L(+) 1.2 Surge voltage category input/output Pollution degree Test voltage input/output Test voltage output/power supply Degree of protection Ambient temperature range Housing material Conformance / approvals Conformity ATEX UL, USA / Canada 0 ... 20 mA / 4 ... 20 mA 25 mA < 500 Ω (at 20 mA) < 10 mVPP (for 500 Ω at 20 mA) MACX MCR-SL-CAC-5-I 19.2 V DC ... 30 V DC < 32 mA (for 24 V DC) ≤ 0.5% (of range nominal value under nominal conditions) < 0.02%/K < 300 ms acc. to EN 61010 300 V AC (to earth) III 2 4 kV (50 Hz, 1 min.) 1.5 kV (50 Hz, 1 min.) IP20 -20°C ... 65°C Polyamide PA non-reinforced MACX MCR-SL-CAC-5-I-UP 19.2 V AC/DC ... 253 V AC/DC < 30 mA (for 24 V DC) ≤ 0.5% (of range nominal value under nominal conditions) < 0.02%/K < 300 ms acc. to EN 61010 300 V AC (to earth) III 2 4 kV (50 Hz, 1 min.) 2 kV (50 Hz, 1 min.) IP20 -20°C ... 65°C Polyamide PA non-reinforced CE compliant X II 3 G Ex nA II T4 X UL applied for Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com PHOENIX CONTACT 393 INTERFACE Analog MACX Analog / MCR Analog Current transducers for sinusoidal and non-sinusoidal alternating currents up to 400 A 55 70,5 85 Power IN I U OUT MCR-SL-S-...00-U POWER SL Current transducer for sinusoidal and non-sinusoidal alternating currents with voltage output 0...(5) 10 V U Ex: U Housing width 55 – True /r.m.s. value measurement from 30...6000 Hz – Measuring range selection with slide switch – Can be retrofitted with the open-up Rogowski coil – Through connection 18.5 mm Ø – Electrical isolation of input and output side The MCR-SL-S-...-U- current transducers convert sinusoidal and nonsinusoidal alternating currents up to 400 A into analog standard signals of 0...5 V or 0...10 V. The measuring ranges for input and output can be selected via a switch. The open up Rogowski coil enables the user to retrofit the current transducer in an existing system without interruption. Insulated conductors on the primary side with a diameter of up to 18.5 mm can be covered. OUT solid Pluggable screw connection stranded [mm2] 0.2-2.5 0.2-2.5 AWG 24-14 Screw M3 383A - 24V Mains voltage MCR-SL-S-...-U = Order No. MCR current transducers for sinusoidal and non-sinusoidal alternating currents Input current range: 0...50/75/100 A Input current range: 0..0.100/150/200 A Input current range: 0..0.200/300/400 A MCR-SL-S-100-U MCR-SL-S-200-U MCR-SL-S-400-U 2813457 2813460 2813473 Technical data Input data Input current Operate threshold Frequency range Curve type Overload capacity Impact overload capacity Connection method Output data Output signal Maximum output signal Load RB General data Supply voltage UB Current consumption Transmission error, max. Cable position error Temperature coefficient Step response (10-90%) Safe isolation ...-S-100-U ...-S-200-U ...-S-400-U 0 ... 100 A 0 ... 200 A 0 ... 400 A 1% (of end value) 30 Hz ... 6000 Hz Sinusoidal and non-sinusoidal No limitation (permanent) No limitation (for 1s) Clamp-on cable design, diameter 18.5 mm 0 ... 5 V / 0 ... 10 V ((0 V ... 10 V) 14 V, (0 V ... 5 V) 7 V) ≥ 10 kΩ Surge voltage category / pollution degree Test voltage input/output Degree of protection Ambient temperature range Housing material Conformance / approvals Conformity UL, USA / Canada 20 V DC ... 30 V DC < 30 mA < 1% (of end value) < 0.63% < 0.035%/K < 340 ms As per IEC 61010-1 and IEC 61326 300 V AC (to earth) III / 2 5 kV (50 Hz, 1 min.) IP20 -20°C ... 60°C Polyamide PA non-reinforced CE compliant cULus 0...5V 0...10V L2 L3 Current measurement PHOENIX CONTACT = Type L1 394 GND OUT Description Rated insulation voltage + IN Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com +24V Pcs. / Pkt. 1 1 1 INTERFACE Analog MACX Analog / MCR Analog Passive current transducers for sinusoidal and non-sinusoidal alternating currents up to 400 A I POWER Power IN I 55 70,5 85 OUT MCR-SL-S-...00-I-LP SL Current transducer for sinusoidal and non-sinusoidal alternating currents with current output 4...20 mA (Loop-powered) U Ex: U Housing width 55 – True /r.m.s. value measurement from 30...6000 Hz – Measuring range selection with slide switch – Loop-powered – Can be retrofitted with the open-up Rogowski coil – Through connection 18.5 mm Ø – Electrical isolation of input and output side OUT solid Pluggable screw connection The MCR-SL-S-...-I-LP- current transducers convert sinusoidal and nonsinusoidal alternating currents up to 400 A into the analog standard signal of 4...20 mA. The measuring range on the output is set with a switch. On the output side, the current transducers are operated in a 4...20 mA current loop, which simultaneously provides the power supply for the modules, necessary for signal conversion. The open up Rogowski coil enables the user to retrofit the current transducer in an existing system without interruption. Insulated conductors on the primary side with a diameter of up to 18.5 mm can be covered. stranded [mm2] 0.2-2.5 0.2-2.5 AWG 24-14 Screw M3 active PLC card – 24V U I Description Type Order No. MCR current transducers for sinusoidal and non-sinusoidal alternating currents Input current range: 0...50/75/100 A Input current range: 0..0.100/150/200 A Input current range: 0..0.200/300/400 A MCR-SL-S-100-I-LP MCR-SL-S-200-I-LP MCR-SL-S-400-I-LP 2813486 2813499 2813509 Technical data Input data Input current Operate threshold Frequency range Curve type Overload capacity Impact overload capacity Connection method Output data Output signal Maximum output signal Load RB General data Supply voltage UB Transmission error, max. Cable position error Temperature coefficient Step response (10-90%) Safe isolation Surge voltage category / pollution degree Test voltage input/output Degree of protection Ambient temperature range Housing material Conformance / approvals Conformity UL, USA / Canada OUT +24V Pcs. / Pkt. 1 1 1 ...-S-100-I-LP ...-S-200-I-LP ...-S-400-I-LP 0 ... 100 A 0 ... 200 A 0 ... 400 A 1% (of end value) 30 Hz ... 6000 Hz Sinusoidal and non-sinusoidal No limitation (permanent) No limitation (for 1s) Clamp-on cable design, diameter 18.5 mm 4 ... 20 mA < 25 mA ((UB - 12 V) x 350 / 12 A) Rated insulation voltage + IN 20 V DC ... 30 V DC < 1% (of end value) < 0.63% < 0.025%/K < 340 ms As per IEC 61010-1 and IEC 61326 300 V AC (to earth) III / 2 5 kV (50 Hz, 1 min.) IP20 -20°C ... 60°C Polyamide PA non-reinforced CE compliant cULus UB=24V 4...20mA Mains voltage MCR-SL-S-...-I-LP L1 L2 L3 Current monitoring Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com PHOENIX CONTACT 395 INTERFACE Analog MACX Analog / MCR Analog Passive current transducer for sinusoidal alternating currents up to 5 A 22,5 114,5 99 Power IN I U,I OUT MCR-SLP-1-5-UI-0 SL Passive current transducers for sinusoidal alternating currents uP Housing width 22.5 IN – Passive current transducer without supply voltage – Measuring ranges 1 A and 5 A AC, reconnectable The passive MCR-SLP-1-5-UI-0 current transducer converts sinusoidal alternating currents of 1 and 5 A into standard 0...20 mA or 0...10 V analog signals. The modules draw power from the measurement circuit, which is needed to convert the signals, making a separate supply for the measuring transducer unnecessary. Input and output sides are electrically isolated from one another. 1A 5A NC solid Screw connection stranded [mm2] 0.2-2.5 0.2-2.5 AWG 24-14 Screw M3 Description Technical data Input data Input current Frequency range Curve type Overload capacity Surge strength Permissible output range Connection method Output data Output signal Maximum output signal Load RB 9 OUT I J 10 500 Type Order No. MCR-SLP-1-5-UI-0 2814359 OUT U 11 GND 12 GND Pcs. / Pkt. 1 A input 5 A input 0 A AC ... 1 A AC 0 A AC ... 5 A AC 45 Hz ... 60 Hz 45 Hz ... 60 Hz Sine Sine 2 x IN (5 min. at 60°C ambient temperature) 50 A (1 s) 100 A (1 s) 1.2 x IN 1.2 x IN Screw connection Screw connection U output I output 0 ... 10 V 0 ... 20 mA 20 V 30 mA > 100 kΩ < 750 Ω < 250 Ω (when current and voltage outputs are used simultaneously) < 50 mVPP < 50 mVPP Rated insulation voltage Surge voltage category / pollution degree Test voltage input/output Degree of protection Ambient temperature range Housing material Conformance / approvals Conformity PHOENIX CONTACT OUT IOUT MCR passive current transducers for sinusoidal alternating currents Ripple General data Transmission error, max. Temperature coefficient Step response (10-90%) Safe isolation 396 1 2 3 4 < 0.5% (of end value) < 0.015%/K < 200 ms as per EN 50178, EN 61010 300 V AC (to earth) III / 2 4 kV (50 Hz, 1 min.) IP20 -25°C ... 60°C Polyamide PA non-reinforced CE compliant Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com 1 INTERFACE Analog MACX Analog / MCR Analog Current protectors for sinusoidal alternating currents up to 16 A 22,5 114,5 99 I Power IN OUT MCR-SL-S-16-SP-24 POWER SL Contactor for sinusoidal alternating currents 0...16 A AC uPz Housing width 22.5 SETPOINT – Switching point can be freely selected in the measuring range of 0...16 A AC – Changeover relay output – Electrical isolation – Adjustable switch hysteresis – Settable operating current / quiescent current behavior The MCR-SL-S-16-SP-24 current protector converts sinusoidal 50 Hz/60 Hz alternating currents into binary switching signals. The current is measured inductively via the wire leading through the module. The switching threshold is set internally by a rough preselection via DIP switches and by a fine adjustment via a potentiometer on the front. A high-quality PDT relay with a gold layer is located on the output side. This can be operated in both operating current and closed circuit current behavior. L1 N Lighting system 10 40 30 NC Emergency lighting L2 N 20 K 14 RELAY ACTIV 50 0 SETPOINT 11 DELAY TIME 12 MCR - SL - S - 16 - SP - 24 5 6 7 8 Delay Screw connection stranded [mm2] 0.2-2.5 0.2-2.5 IN solid AWG 24-14 Screw M3 24V DC 13 GND 14 NC 15 NC 16 Description = = 12 11 14 NC OUT Type Order No. MCR-SL-S- 16-SP- 24 2864464 Pcs. / Pkt. MCR current protector for sinusoidal alternating currents Technical data Input data Input current Frequency range Curve type Overload capacity Connection method Switching output Contact type Contact material Max. switching current Switching hysteresis Response delay Operating and closed circuit current behavior Relay status display General data Supply voltage UB Current consumption Setting accuracy Temperature coefficient Step response (10-90%) Safe isolation Rated insulation voltage Surge voltage category / pollution degree Test voltage input/output Test voltage input/power supply Degree of protection Ambient temperature range Housing material Conformance / approvals Conformity 1 0 A AC ... 16 A AC 45 Hz ... 65 Hz Sine 2 x IN (continuous) Through connection, diameter 4.2 mm Relay output 1 PDT AgSnO, hard gold-plated 50 mA (for gold layer, 30 V AC/ 36 V DC) 2 A (in case of a destroyed gold layer, 250 V AC) Adjustable using a DIP switch (0.5%, 5%, 10%, 15%) Typ. 0.1 s ... 10 s (adjustable using a potentiometer) Adjustable using a DIP switch LED yellow (relay active) 20 V DC ... 30 V DC < 30 mA < 0.5% < 0.02%/K 40 ms as per EN 50178, EN 61010-1 300 V AC (to earth) III / 2 4 kV (50 Hz, 1 min.) 4 kV (50 Hz, 1 min.) IP20 -20°C ... 65°C Polyamide PA non-reinforced CE compliant + 24V GND NC NC 24V Mains voltage Lighting system with emergency lighting Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com PHOENIX CONTACT 397 INTERFACE Analog MACX Analog / MCR Analog Voltage transducers for DC voltages up to 660 V 22,5 99 114,5 FL U= Power IN U,I OUT MCR-VDC-UI-B-DC POWER Voltage transducers for DC voltages up to ± 660 V DC uPz Housing width 22.5 IN – 3-way isolation – Adjustable voltage ranges – ZERO/SPAN adjustment ± 20% solid The MCR-VDC-UI-B-DC voltage transducers can be used to record voltage values between 0... ± 20 V DC and 0... ± 660 V DC in several signal ranges and to convert them into standardized analog signals. The signal ranges are selected via the input screw terminal blocks, in part by jumpers. An adjustment of ± 20% allows you to define the range end value within the signal range individually. Pluggable screw connection stranded [mm2] 0.2-2.5 0.2-2.5 ±550V ±370V ±250V ±170V AWG 24-14 Screw M3 Description Technical data Input data Input voltage range/resistance IN 1 U1 6 U6 2 U2 7 U7 MCR-VDC-UI-B-DC OUT 13 + 24V 14 GND 2 11 GND 3 8 GND 1 4 U4 GND 2 12 ZERO + 24V 3 U3 SPAN 9 10 2811116 Surge voltage category / pollution degree Test voltage input/output Degree of protection Ambient temperature range Housing material Conformance / approvals Conformity 18.5 V DC ... 30.2 V DC < 50 mA < 1% (of end value) < 0.015%/K 40 Hz 12 ms acc. to EN 50178 150 V DC (to earth) II / 2 1.5 kV (50 Hz, 1 min.) IP20 -25°C ... 50°C Polyamide PA non-reinforced CE compliant 16 24V Mains voltage Voltage measurement in case of ungrounded circuits PHOENIX CONTACT 8 MCR-VDC-UI-B-DC Tachometer generator 398 J J J Order No. 15 GND 3 7 13 + 24VDC 14 + 24VDC 15 GND3 16 GND3 Type POWER I U Power ±24V DC 5 U5 5 6 -550 V DC ... 550 V DC -370 V DC ... 370 V DC -250 V DC ... 250 V DC -170 V DC ... 170 V DC -120 V DC ... 120 V DC -80 V DC ... 80 V DC -54 V DC ... 54 V DC -36 V DC ... 36 V DC -24 V DC ... 24 V DC ± 20% / ± 20% U output -10 ... 10 V ± 15 V > 10 kΩ < 50 mVPP Rated insulation voltage ± 10V 9 OUT I 10 OUT U 11 GND2 12 GND2 Pcs. / Pkt. MCR voltage transducer, for DC voltages from 0...± 20 V DC to 0...± 660 V DC ZERO / SPAN adjustment Output data Output signal Maximum output signal Load RB Ripple General data Supply voltage UB Current consumption Transmission error, max. Temperature coefficient Limit frequency (3 dB) Step response (10-90%) Safe isolation Control system ±120V ±80V ±54V ±36V ±24V GND 1 OUT 1 2 3 4 Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com 550 kΩ 370 kΩ 250 kΩ 170 kΩ 120 kΩ 80 kΩ 54 kΩ 36 kΩ 24 kΩ I output -20 ... 20 mA ± 30 mA < 500 Ω < 50 mVPP 1 INTERFACE Analog MACX Analog / MCR Analog Voltage transducers for sinusoidal AC voltages of up to 440 V 22,5 99 Power 114,5 FL U,I U IN OUT MCR-VAC-UI-O-DC POWER Voltage transducer for sinusoidal AC voltages of up to 440 V AC uPz Housing width 22.5 IN – – – – 3-way isolation TRMS measurement Adjustable voltage ranges ZERO/SPAN adjustment ± 20% solid Pluggable screw connection The MCR-VAC-UI-0-DC voltage transducers can be used to measure voltage values between 0...20 V AC and 0...440 V AC in several signal ranges and to convert them into standard analog signals. The signal ranges are selected via the input screw terminal blocks, in part by jumpers. An adjustment of ± 20% allows you to define the range end value within the signal range individually. stranded [mm2] 0.2-2.5 0.2-2.5 AWG 24-14 Screw M3 Description Technical data Input data Input voltage range/resistance IN MCR-VAC-UI-O-DC OUT 5 6 7 13 + 24VDC 14 + 24VDC 15 GND3 16 GND3 J J 8 Type Order No. MCR-VAC-UI-O-DC 2811103 Pcs. / Pkt. 1 370 kΩ 250 kΩ 170 kΩ 120 kΩ 80 kΩ 54 kΩ 36 kΩ 24 kΩ I output 0 ... 20 mA / 4 ... 20 mA 30 mA < 500 Ω < 50 mVPP 18.5 V DC ... 30.2 V DC < 45 mA < 1.5% (of end value) Typ. 0.02%/K (50/60 Hz) 250 ms acc. to EN 50178 300 V AC (to earth) III / 2 3.3 kV (50 Hz, 1 min.) 3.3 kV (50 Hz, 1 min.) 1 kV (50 Hz, 1 min.) IP20 -25°C ... 60°C Polyamide PA non-reinforced CE compliant POWER 7 U7 3 U3 GND 2 8 GND 1 4 U4 GND 2 ZERO 2 U2 SPAN 1 U1 6 U6 Power 5 U5 I 9 + 24V 13 U 10 + 24V 14 11 GND 3 12 L1 L2 L3 N 0-80V 0-54V 0-36V 0-24V GND 1 0 V ... 370 V AC 0 V ... 250 V AC 0 V ... 170 V AC 0 V ... 120 V AC 0 V ... 80 V AC 0 V ... 54 V AC 0 V ... 36 V AC 0 V ... 24 V AC ± 20% / ± 20% 45 Hz ... 400 Hz U output 0 ... 10 V 15 V > 10 kΩ < 50 mVPP Rated insulation voltage Surge voltage category / pollution degree Test voltage input/output Test voltage input/power supply Test voltage output/power supply Degree of protection Ambient temperature range Housing material Conformance / approvals Conformity 4...20mA 9 OUT I 10 OUT U 11 GND2 12 GND2 MCR voltage transducer, for sinusoidal AC voltages from 0...20 V AC to 0...440 V AC ZERO / SPAN adjustment Frequency range Output data Output signal Maximum output signal Load RB Ripple General data Supply voltage UB Current consumption Transmission error, max. Temperature coefficient Step response (10-90%) Safe isolation Control system OUT 0-370V 1 0-250V 2 0-170V 3 0-120V 4 15 16 GND 3 24V Mains voltage Voltage measurement in case of grounded circuits Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com PHOENIX CONTACT 399 INTERFACE Analog PACT Analog PACT Analog current transformers 400 PHOENIX CONTACT Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com INTERFACE Analog Power PACT Analog Power: – Bus-bar current transformers – Plug-in current transformers – Winding current transformers Minimum constructional depth All converters have a uniform width of 30 mm. Flexible use The primary rail support is removable and thus allows flat installation directly on the copper rail. This is the starting point for space-saving applications. The current transformers are available in calibration-capable and non-calibration-capable versions. Variable mounting options One of these space-saving applications is, for instance, current measurement in branch exits. The conductive connection of a copper rail with another is implemented using a copper sleeve. It is inserted into the inner hole of the horizontal current transformer. Minimum constructional depth Flexible use PACT Analog current transformers offer safe isolation The PACT Analog current transformers are tested as per the EN 50178 standard ("Electronic equipment for use in electrical power installations"). The main topics of the EN 50178 are safety and reliability. The current transformers are tested with an impulse withstand voltage of 12 kV due to the safe isolation required. The amplitude of the impulse withstand voltage is rated for double isolation (safe isolation) of network circuits from the environment as per surge voltage category 3. The amount of the impulse withstand voltage results in a maximum permissible rated insulation voltage of 1000 V. Safe isolation prevents sparkovers from occurring at the secondary side of the current transformer. A voltage dangerous to human beings can thus not advance into other electrical components. There is no hazard for human beings - within as well as outside the control cabinet. Variable mounting options Professional connection method E.g. Ethernet SELV = Safety extra low voltage Safe isolation Current transducers (e.g. MACX MCR-SL-CAC-5-I) Controllers Motor Up to 1 kV Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com PHOENIX CONTACT 401 INTERFACE Analog PACT Analog PACT Analog - The range of current transformers for versatile mounting With PACT Analog, Phoenix Contact offers a complete range of rod, plug-on and wound type current transformers for measuring high currents ranging between 1 A and 4000 A. These high-quality current transformers are available in almost 3000 different designs. You can choose from different accuracy classes, capacities and sizes depending on your application. – First, the type of transformer suitable for the specified copper rail dimensions is determined. – Then the four electrical features of the transformer are defined on the basis of the given selection table according to the order key: 1.The primary rated current strength Ipn, the current strength occurring most frequently in the application path to be measured. 2.The secondary rated current Isn that is supplied to the downstream measuring devices. 3.The class (accuracy) for adherence to the specified tolerances. 4.The rated power Sn (in VA), in which all the occurring loads of the measuring circuit are considered. Order key for PACT MCR-V2-3015-60 (example) On-stock types that can be ordered directly have been marked in green in the selection table. Order No. 2277271 Primary current Ipn / IP00600 IP00750 IP00800 IP01000 IP01250 IP02000 IP02500 Determination of the secondary side rated power Sn All the occurring loads must be added: – Calculate the power requirement of the copper cable (supply and return line) – Take into account the power requirement of the connected devices (measuring devices) – Add a reserve requirement = = = = = = = Power requirement of copper cables with a different diameter IS05 60 A 75 A 80 A 100 A 125 A 200 A 250 A Class / IS01 = 1 A IS05 = 5 A Secondary current Isn 1A 0.2917 0.1750 0.1094 0.0729 0.117 0.0070 0.0044 0.0029 Isn Cl. 2. Primary rated current strength Ipn [A] 60 75 80 100 125 150 1.25 2.5 2.5 0.5 1A 1.25 2.5 2.5 2.5 1 2.5 3.75 2.5 5 Example: Copper cable Sn = cable length x 2 x rated power Copper cable Sn = 10 m x 2 x 0.1750 VA/m = 3.50 VA 0.5 200 2.5 3.75 250 2.5 5 2.5 5 2.5 5 7.5 2.5 3.75 2.5 5 1.25 1 1.25 1.5 1.25 2 2.5 2.5 3.75 2.5 3.75 5 2.5 5 7.5 2.5 5 7.5 10 Total Sn = copper cable Sn + measuring device Sn + reserve Sn Total Sn = 3.5 VA + 2 VA + 2 VA = 7.5 VA 402 PHOENIX CONTACT Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com P750 P125 P250 P375 P500 P750 P1000 3. Measuring device Sn = 2 VA 5A / C02 = 0.2 C05 = 0.5 C10 = 1 Rated power Sn [VA] Secondary current Isn 5A Reserve Sn < 0.5 x (copper cable Sn + measuring device Sn) Reserve Sn = 2 VA Rated power Sn C10 Selection table (extract) Rated power in VA/m (Observe the supply and the return line) 1.5 2.5 4 6 / 1. Total Sn = copper cable Sn + measuring device Sn + reserve Sn Conductor crosssection in mm2 Secondary current Isn IP02000 = = = = = = 1.25 VA 2.5 VA 3.75 VA 5.0 VA 7.5 VA 10 VA 4. INTERFACE Analog PACT Analog Current transformers 21 16 PACT MCR-V1-21-44-... Bus-bar current transformer Housing width 30 Rated power Sn Description Preferred versions available from stock (marked in green in the selection table) Primary rated current Ipn: - 50 A 1.25 VA - 75 A 2.5 VA - 100 A 2.5 VA - 150 A 5 VA - 250 A 5 VA - 400 A 5 VA Current transformers, pay attention to the following ordering key for determining the desired current transformer type Technical data Input data Thermal rated short-time current Rated surge current Rated frequency Surge current limitation factor General data Rated insulation voltage Test voltage Can be calibrated Insulating material class Connection capacity of secondary terminals Ambient temperature (operation) Standards/regulations Housing material Dimensions L / W / H Dimensions (alternative assembly) L / B / H Order No. PACT MCR-V1-21-44- 50-5A-1 PACT MCR-V1-21-44- 75-5A-1 PACT MCR-V1-21-44-100-5A-1 PACT MCR-V1-21-44-150-5A-1 PACT MCR-V1-21-44-250-5A-1 PACT MCR-V1-21-44-400-5A-1 2277019 2277611 2277022 2277035 2277048 2277051 1 1 1 1 1 1 PACT MCR-V1- 21- 44 2277268 1 Ith = 60 * In Idyn = 2.5 * Ith 50 Hz ... 60 Hz FS 5 1 kV 3 kV (50 Hz, 1 min.) No E 2 x (2.5 x 4) mm -25°C ... 40°C IEC 60044-1 Polyamide PA glass fiber reinforced 44 / 30 / 66 mm 30 / 44 / 66 mm Add to order key from the selection table (ordering example marked in orange) Order No. Primary current Ipn Secondary current Isn Class 2277268 / IP05000 / IS01 Selection table PACT MCR-V1-21-44 (Order No.: 2277268) Primary rated current strength Ipn [A] Isn Cl. 50 60 75 80 100 125 1.25 2.5 C05 = 0.5 IS01 =1A 1.25 1.25 2.5 2.5 2.5 2.5 C10 3.75 =1 C05 = 0.5 IS05 =5 A 1.25 C10 =1 1.25 1.5 2.5 Pcs. / Pkt. Type 2.5 / C05 Rated power Sn / P1000 150 2.5 3.75 200 2.5 5 250 2.5 5 7.5 300 2.5 5 400 2.5 5 7.5 500 2.5 5 10 2.5 5 2.5 5 2.5 5 7.5 2.5 5 2.5 5 7.5 2.5 5 10 1.25 1.5 1.25 2.0 1.25 2.5 2.5 3.75 2.5 5 7.5 2.5 5 10 2.5 5 7.5 2.5 5 7.5 2.5 2.5 3.75 2.5 5 2.5 5 7.5 2.5 5 7.5 2.5 5 10 2.5 5 7.5 2.5 5 10 Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com PHOENIX CONTACT Rated power Sn [VA] Note: Our configurator provides you with a convenient ordering option under www.phoenixcontact.de/eshop. The relevant installation accessories can be found on page 419. 50 Due to their primary rail holder that can be pulled out, the PACT analog current transformers are suitable for horizontal and vertical installation. It is thus possible to place current transformers in parallel directly on the copper rail. This is particularly convenient in the case of spacecritical applications. 30 44 26 PACT MCR-V1-21-44 – Primary rated current Ipn: 0...(50...500) A – Round conductor dimensions: Ø 21 mm 403 INTERFACE Analog PACT Analog Current transformers 28 23x23 16x33 16 PACT MCR-V2-3015-60-... Plug-in current transformer Housing width 30 Rated power Sn Description Preferred versions available from stock (marked in green in the selection table) Primary rated current Ipn: - 100 A 2.5 VA - 125 A 3.75 VA - 150 A 5 VA - 200 A 5 VA - 250 A 10 VA - 300 A 7.5 VA - 400 A 10 VA - 500 A 10 VA - 600 A 10 VA - 750 A 10 VA Current transformers, pay attention to the following ordering key for determining the desired current transformer type Technical data Input data Thermal rated short-time current Rated surge current Rated frequency Surge current limitation factor General data Rated insulation voltage Test voltage Can be calibrated Insulating material class Connection capacity of secondary terminals Ambient temperature (operation) Standards/regulations Housing material Dimensions L / W / H Dimensions (alternative assembly) L / B / H Order No. PACT MCR-V2-3015- 60- 100-5A-1 PACT MCR-V2-3015- 60- 125-5A-1 PACT MCR-V2-3015- 60- 150-5A-1 PACT MCR-V2-3015- 60- 200-5A-1 PACT MCR-V2-3015- 60- 250-5A-1 PACT MCR-V2-3015- 60- 300-5A-1 PACT MCR-V2-3015- 60- 400-5A-1 PACT MCR-V2-3015- 60- 500-5A-1 PACT MCR-V2-3015- 60- 600-5A-1 PACT MCR-V2-3015- 60- 750-5A-1 2277064 2277624 2277077 2277637 2277080 2277640 2277093 2277653 2277103 2277666 1 1 1 1 1 1 1 1 1 1 PACT MCR-V2-3015- 60 2277271 1 Ith = 60 * In Idyn = 2.5 * Ith 50 Hz ... 60 Hz FS 5 1 kV 3 kV (50 Hz, 1 min.) No E 2 x (2.5 x 4) mm -25°C ... 40°C IEC 60044-1 Polyamide PA glass fiber reinforced 60 / 30 / 80 mm 30 / 60 / 80 mm Add to order key from the selection table (ordering example marked in orange) Order No. Primary current Ipn Secondary current Isn Class 2277271 / IP07500 / IS01 Selection table PACT MCR-V2-3015-60 (Order No.: 2277271) Primary rated current strength Ipn [A] Isn Cl. 50 60 75 80 100 125 1.25 2.5 C05 = 0.5 IS01 =1 A 1.25 1.25 2.5 2.5 2.5 2.5 C10 3.75 =1 / 1.25 C10 =1 404 PHOENIX CONTACT 1.25 1.5 1.25 2 2.5 2.5 3.75 C05 Rated power Sn / P1500 150 2.5 200 2.5 3.75 250 2.5 5 300 2.5 5 7.5 400 2.5 5 10 500 2.5 5 10 2.5 5 2.5 5 2.5 5 7.5 2.5 5 10 2.5 5 10 2.5 5 10 2.5 3.75 2.5 5 2.5 5 7.5 2.5 5 10 2.5 5 7.5 2.5 5 7.5 10 2.5 5 7.5 10 2.5 5 10 15 C05 = 0.5 IS05 =5A Pcs. / Pkt. Type 2.5 3.75 5 Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com 2.5 5 10 600 2.5 5 10 15 2.5 5 10 15 2.5 5 10 750 2.5 5 10 15 5 10 15 20 2.5 5 10 2.5 5 10 2.5 5 10 2.5 5 10 15 Rated power Sn [VA] Note: Our configurator provides you with a convenient ordering option under www.phoenixcontact.de/eshop. The relevant installation accessories can be found on page 419. 64 Due to their primary rail holder that can be pulled out, the PACT analog current transformers are suitable for horizontal and vertical installation. It is thus possible to place current transformers in parallel directly on the copper rail. This is particularly convenient in the case of spacecritical applications. 30 60 33x16 PACT MCR-V2-3015-60 – Primary rated current Ipn: 0...(50...750) A – Round conductor dimensions: Ø 28 mm – Rail dimensions: 30x15 mm; 20x20 mm INTERFACE Analog PACT Analog Current transformers 13x40,5 33 PACT MCR-V2-4012-70-... Plug-in current transformer Housing width 30 Rated power Sn Description Preferred versions available from stock (marked in green in the selection table) Primary rated current Ipn: - 250 A 5 VA - 300 A 7.5 VA - 400 A 7.5 VA - 500 A 10 VA - 600 A 10 VA - 750 A 10 VA - 800 A 10 VA - 1000 A 10 VA Current transformers, pay attention to the following ordering key for determining the desired current transformer type Technical data Input data Thermal rated short-time current Rated surge current Rated frequency Surge current limitation factor General data Rated insulation voltage Test voltage Can be calibrated Insulating material class Connection capacity of secondary terminals Ambient temperature (operation) Standards/regulations Housing material Dimensions L / W / H Dimensions (alternative assembly) L / B / H Order No. PACT MCR-V2-4012- 70- 250-5A-1 PACT MCR-V2-4012- 70- 300-5A-1 PACT MCR-V2-4012- 70- 400-5A-1 PACT MCR-V2-4012- 70- 500-5A-1 PACT MCR-V2-4012- 70- 600-5A-1 PACT MCR-V2-4012- 70- 750-5A-1 PACT MCR-V2-4012- 70- 800-5A-1 PACT MCR-V2-4012- 70-1000-5A-1 2277116 2277679 2277129 2277682 2277132 2277695 2277145 2277158 1 1 1 1 1 1 1 1 PACT MCR-V2-4012- 70 2277284 1 Ith = 60 * In Idyn = 2.5 * Ith 50 Hz ... 60 Hz FS 5 1 kV 3 kV (50 Hz, 1 min.) No E 2 x (2.5 x 4) mm -25°C ... 40°C IEC 60044-1 Polyamide PA glass fiber reinforced 70 / 30 / 90 mm 30 / 70 / 90 mm Add to order key from the selection table (ordering example marked in orange) Order No. Primary current Ipn Secondary current Isn Class 2277284 / IP010000 / IS05 Selection table PACT MCR-V2-4012-70 (Order No.: 2277284) Primary rated current strength Ipn [A] Isn Cl. 75 80 100 125 150 200 1.25 2.5 2.5 C05 3.75 = 0.5 IS01 =1 A 1.25 1.25 2.5 2.5 2.5 2.5 C10 3.75 5 5 =1 1.25 C10 =1 1.25 2.5 / C10 Rated power Sn / P250 250 2.5 5 300 2.5 5 400 2.5 5 7.5 500 2.5 5 10 600 2.5 5 10 750 2.5 5 10 2.5 5 7.5 2.5 5 10 2.5 5 10 2.5 5 10 2.5 5 10 2.5 5 10 15 2.5 5 10 1.25 2.5 2.5 3.75 2.5 5 2.5 5 2.5 5 7.5 2.5 5 10 2.5 5 10 2.5 3.75 2.5 5 2.5 5 2.5 5 7.5 2.5 5 7.5 2.5 5 7.5 2.5 5 10 2.5 5 10 C05 = 0.5 IS05 =5A Pcs. / Pkt. Type Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com 2.5 5 10 15 800 2.5 5 10 15 2.5 5 10 15 2.5 5 10 15 2.5 5 10 15 1000 2.5 5 10 2.5 5 10 2.5 5 10 Rated power Sn [VA] Note: Our configurator provides you with a convenient ordering option under www.phoenixcontact.de/eshop. The relevant installation accessories can be found on page 419. 31x31 74 Due to their primary rail holder that can be pulled out, the PACT analog current transformers are suitable for horizontal and vertical installation. It is thus possible to place current transformers in parallel directly on the copper rail. This is particularly convenient in the case of spacecritical applications. 30 16 70 40,5x13 PACT MCR-V2-4012-70 – Primary rated current Ipn: 0...(75...1000) A – Round conductor dimensions: Ø 33 mm – Rail dimensions: 40x12 mm; 2x 30x10 mm 2.5 5 10 PHOENIX CONTACT 405 INTERFACE Analog PACT Analog Current transformers 42 41x31 31x41 PACT MCR-V2-5012-85-... Plug-in current transformer Housing width 30 Rated power Sn Description Preferred versions available from stock (marked in green in the selection table) Primary rated current Ipn: - 400 A 10 VA - 600 A 10 VA - 800 A 10 VA - 1000 A 15 VA - 1250 A 15 VA Current transformers, pay attention to the following ordering key for determining the desired current transformer type Technical data Input data Thermal rated short-time current Rated surge current Rated frequency Surge current limitation factor General data Rated insulation voltage Test voltage Can be calibrated Insulating material class Connection capacity of secondary terminals Ambient temperature (operation) Standards/regulations Housing material Dimensions L / W / H Dimensions (alternative assembly) L / B / H Order No. PACT MCR-V2-5012- 85- 400-5A-1 PACT MCR-V2-5012- 85- 600-5A-1 PACT MCR-V2-5012- 85- 800-5A-1 PACT MCR-V2-5012- 85-1000-5A-1 PACT MCR-V2-5012- 85-1250-5A-1 2277161 2277174 2277187 2277190 2277200 1 1 1 1 1 PACT MCR-V2- 5012- 85 2277297 1 Ith = 60 * In Idyn = 2.5 * Ith 50 Hz ... 60 Hz FS 5 1 kV 3 kV (50 Hz, 1 min.) No E 2 x (2.5 x 4) mm -25°C ... 40°C IEC 60044-1 Polyamide PA glass fiber reinforced 85 / 30 / 108 mm 30 / 85 / 108 mm Add to order key from the selection table (ordering example marked in orange) Order No. Primary current Ipn Secondary current Isn Class 2277297 / IP02500 / IS01 Selection table PACT MCR-V2-5012-85 (Order No.: 2277297) Primary rated current strength Ipn [A] Isn Cl. 100 125 150 200 250 300 1.25 2.5 2.5 2.5 C05 5 5 5 = 0.5 7.5 IS01 =1 A 1.25 2.5 C10 =1 2.5 3.75 2.5 5 7.5 1.25 2.5 5 2.5 3.75 2.5 5 7.5 C05 = 0.5 IS05 =5A 1.25 C10 =1 406 PHOENIX CONTACT 2.5 Pcs. / Pkt. Type 2.5 5 7.5 10 2.5 5 2.5 5 10 2.5 5 7.5 10 2.5 5 10 2.5 5 7.5 / 400 2.5 5 10 15 2.5 5 10 15 2.5 5 10 15 2.5 5 10 15 Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com C10 500 2.5 5 10 15 2.5 5 10 20 2.5 5 10 15 5 10 15 20 Rated power Sn / 600 2.5 5 10 15 2.5 5 10 20 2.5 5 20 15 5 10 15 20 P750 750 2.5 5 10 800 2.5 5 10 2.5 5 10 2.5 5 10 15 2.5 5 10 2.5 5 10 2.5 5 10 2.5 5 10 15 1000 2.5 5 10 15 5 10 15 20 2.5 5 10 15 5 10 15 20 1250 2.5 5 10 15 5 10 15 20 2.5 5 10 15 5 10 15 20 1500 2.5 5 10 15 5 10 15 30 2.5 5 10 15 5 10 15 20 Rated power Sn [VA] Note: Our configurator provides you with a convenient ordering option under www.phoenixcontact.de/eshop. The relevant installation accessories can be found on page 419. 13x50,5 16 92 Due to their primary rail holder that can be pulled out, the PACT analog current transformers are suitable for horizontal and vertical installation. It is thus possible to place current transformers in parallel directly on the copper rail. This is particularly convenient in the case of spacecritical applications. 30 85 50,5x13 PACT MCR-V2-5012-85 – Primary rated current Ipn: 0...(100...1500) A – Round conductor dimensions: Ø 42 mm – Rail dimensions: 50x12 mm; 2x 40x10 mm INTERFACE Analog PACT Analog Current transformers Note: Our configurator provides you with a convenient ordering option under www.phoenixcontact.de/eshop. The relevant installation accessories can be found on page 419. 53 32x54 54x32 42x42 105 16x64 16 30 PACT MCR-V2-6315-95-... Plug-in current transformer Housing width 30 Rated power Sn Description Preferred versions available from stock (marked in green in the selection table) Primary rated current Ipn: - 800 A 10 VA - 1000 A 10 VA - 1250 A 10 VA - 1500 A 10 VA - 1600 A 10 VA Current transformers, pay attention to the following ordering key for determining the desired current transformer type Technical data Input data Thermal rated short-time current Rated surge current Rated frequency Surge current limitation factor General data Rated insulation voltage Test voltage Can be calibrated Insulating material class Connection capacity of secondary terminals Ambient temperature (operation) Standards/regulations Housing material Dimensions L / W / H Dimensions (alternative assembly) L / B / H Order No. PACT MCR-V2-6315- 95- 800-5A-1 PACT MCR-V2-6315- 95-1000-5A-1 PACT MCR-V2-6315- 95-1250-5A-1 PACT MCR-V2-6315- 95-1500-5A-1 PACT MCR-V2-6315- 95-1600-5A-1 2277213 2277226 2277239 2277242 2277255 1 1 1 1 1 PACT MCR-V2- 6315- 95 2277307 1 Ith = 60 * In Idyn = 2.5 * Ith 50 Hz ... 60 Hz FS 5 1 kV 3 kV (50 Hz, 1 min.) No E 2 x (2.5 x 4) mm -25°C ... 40°C IEC 60044-1 Polyamide PA glass fiber reinforced 95 / 30 / 121 mm 30 / 95 / 121 mm Add to order key from the selection table (ordering example marked in orange) Order No. Primary current Ipn Secondary current Isn Class 2277307 / IP25000 / IS05 Selection table PACT MCR-V2-6315-95 (Order No.: 2277307) Primary rated current strength Ipn [A] Isn Cl. 200 250 300 400 500 600 2.5 2.5 2.5 2.5 2.5 2.5 C05 5 5 5 5 = 0.5 7.5 10 10 IS01 =1 A C10 =1 2.5 3.75 2.5 5 2.5 5 7.5 2.5 5 10 2.5 5 10 2.5 2.5 3.75 2.5 5 7.5 2.5 5 10 2.5 3.75 2.5 5 2.5 5 10 2.5 5 10 15 2.5 5 10 15 5 10 15 20 C05 = 0.5 IS05 =5A C10 =1 Pcs. / Pkt. Type 2.5 5 10 15 2.5 5 10 15 5 10 15 20 / C05 Rated power Sn / P500 750 5 10 15 800 5 10 15 1000 5 10 1250 5 10 1500 5 10 15 1600 5 10 15 5 10 15 5 10 15 20 5 10 15 20 5 10 15 30 5 10 5 10 5 10 15 5 10 15 30 10 15 30 5 10 15 20 5 10 15 30 5 10 15 30 5 10 15 30 5 10 15 20 5 10 15 30 Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com 2500 5 10 15 2000 5 10 15 20 10 15 20 5 10 15 30 10 15 30 5 10 15 30 10 15 30 5 10 15 30 10 15 30 PHOENIX CONTACT Rated power Sn [VA] Due to their primary rail holder that can be pulled out, the PACT analog current transformers are suitable for horizontal and vertical installation. It is thus possible to place current transformers in parallel directly on the copper rail. This is particularly convenient in the case of spacecritical applications. 95 64x16 PACT MCR-V2-6315-95 – Primary rated current Ipn: 0...(200...2500) A – Round conductor dimensions: Ø 53 mm – Rail dimensions: 63x15 mm 2x 50x10 mm 40x40 mm 407 INTERFACE Analog PACT Analog Current transformers PACT MCR-V2-6015-85 – Primary rated current Ipn: 0...(200...1600) A – Round conductor dimensions: Ø 52 mm – Rail dimensions: 60x15 mm; 2x 50x10 mm; 40x40 mm PACT MCR-V2-6040-96 – Primary rated current Ipn: 0...(200...2000) A – Round conductor dimensions: Ø 61 mm – Rail dimensions: 60x40 mm; 50x50 mm Housing width 30 96 16 Pcs. / Pkt. PACT MCR-V2- 6015- 85 2277336 1 Technical data Input data Thermal rated short-time current Ith = 60 * In Rated surge current Idyn = 2.5 * Ith Rated frequency 50 Hz ... 60 Hz Surge current limitation factor FS 5 General data Rated insulation voltage 1 kV Test voltage 3 kV (50 Hz, 1 min.) Can be calibrated No Insulating material class E Connection capacity of secondary terminals 2 x (2.5 x 4) mm Ambient temperature (operation) -25°C ... 40°C Standards/regulations IEC 60044-1 Housing material Polyamide PA glass fiber reinforced Dimensions L / W / H 85 / 30 / 108 mm Dimensions (alternative assembly) L / B / H 30 / 85 / 108 mm Add to order key from the selection table (ordering example marked in orange) Order No. Primary current Ipn Secondary current Isn Class Rated power Sn IP05000 / IS01 / C10 / C05 = 0.5 IS05 =5A 2.5 1.25 1.25 1.25 2.5 2.5 5 2.5 5 10 2.5 5 10 2.5 2.5 5 2.5 5 10 2.5 5 10 2.5 C10 =1 408 PHOENIX CONTACT 2.5 2.5 5 10 15 2.5 5 10 15 2.5 5 10 15 5 10 15 5 10 15 20 5 10 15 20 5 10 15 20 5 10 15 30 61 Pcs. / Pkt. Type Order No. PACT MCR-V2-6040- 96-1000-5A-1 PACT MCR-V2-6040- 96-1500-5A-1 2277705 2277718 1 1 PACT MCR-V2- 6040- 96 2277349 1 Ith = 60 * In Idyn = 2.5 * Ith 50 Hz ... 60 Hz FS 5 1 kV 3 kV (50 Hz, 1 min.) No E 2 x (2.5 x 4) mm -25°C ... 40°C IEC 60044-1 Polyamide PA glass fiber reinforced 96 / 30 / 121 mm 30 / 96 / 121 mm P375 Selection table PACT MCR-V2-6015-85 (Order No.: 2277336) Primary rated current strength Ipn [A] Isn Cl. 200 250 300 400 500 600 750 800 1000 1250 1500 1600 1.25 1.25 1.25 2.5 2.5 2.5 2.5 2.5 2.5 C05 5 5 = 0.5 IS01 =1 A 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 C10 3.75 5 3.75 3.75 5 =1 5 10 15 5 10 15 Rated power Sn [VA] / 44x64 105 Order No. 54x54 52 42x42 52x32 32x52 16x60,5 16 92 Type Preferred versions available from stock (marked in green in the selection table) Primary rated current Ipn: - 1000 A 10 VA - 1500 A 10 VA Current transformers, pay attention to the following ordering key for determining the desired current transformer type 2277336 30 30 Selection table PACT MCR-V2-6040-96 (Order No.: 2277349) Primary rated current strength Ipn [A] Isn Cl. 200 250 300 400 500 600 750 800 1000 1250 1500 1600 2000 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 C05 5 5 5 5 5 5 5 = 0.5 7.5 7.5 7.5 10 10 IS01 =1 A 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 C10 3.75 5 5 5 5 5 5 5 5 5 5 =1 7.5 7.5 7.5 7.5 10 10 2.5 2.5 2.5 5 2.5 5 7.5 2.5 5 7.5 2.5 5 10 2.5 5 10 2.5 5 7.5 2.5 5 10 2.5 5 10 2.5 2.5 3.75 3.75 2.5 5 2.5 5 7.5 2.5 5 7.5 2.5 5 10 2.5 5 10 2.5 5 10 15 2.5 5 10 5 10 15 2.5 5 10 C05 = 0.5 IS05 =5A C10 =1 Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com 2.5 5 10 15 5 10 15 5 10 15 5 10 15 Rated power Sn [VA] Rated power Sn Plug-in current transformer 85 Note: Our configurator provides you with a convenient ordering option under www.phoenixcontact.de/eshop. Description PACT MCR-V2-6040- 96 Plug-in current transformer Housing width 30 60,5x16 Due to their primary rail holder that can be pulled out, the PACT analog current transformers are suitable for horizontal and vertical installation. It is thus possible to place current transformers in parallel directly on the copper rail. This is particularly convenient in the case of spacecritical applications. PACT MCR-V2-6015- 85 INTERFACE Analog PACT Analog Current transformers PACT MCR-V2-8015-105 – Primary rated current Ipn: 0...(400...2500) A – Round conductor dimensions: Ø 61 mm – Rail dimensions: 80x15 mm; 2x 60x10 mm; 3x 50x10 mm PACT MCR-V2-8020-105 – Primary rated current Ipn: 0...(500...2000) A – Round conductor dimensions: Ø 70 mm – Rail dimensions: 2x 80x10 mm; 60x60 mm Preferred versions available from stock (marked in green in the selection table) Primary rated current Ipn: - 1000 A 10 VA - 1500 A 15 VA Current transformers, pay attention to the following ordering key for determining the desired current transformer type Housing width 30 30 PACT MCR-V2-8015-105-1000-5A-1 PACT MCR-V2-8015-105-1500-5A-1 2277721 2277734 PACT MCR-V2-8015-105 2277352 Pcs. / Pkt. IP25000 / IS05 / C10 / 31x81 70 Pcs. / Pkt. Type Order No. 1 1 PACT MCR-V2-8020-105-1000-5A-1 PACT MCR-V2-8020-105-1500-5A-1 2277747 2277750 1 1 1 PACT MCR-V2- 8020-105 2277365 1 Ith = 60 * In Idyn = 2.5 * Ith 50 Hz ... 60 Hz FS 5 1 kV 3 kV (50 Hz, 1 min.) No E 2 x (2.5 x 4) mm -25°C ... 40°C IEC 60044-1 Polyamide PA glass fiber reinforced 105 / 30 / 132 mm 30 / 105 / 132 mm P3000 Selection table PACT MCR-V2-8020-105 (Order No.: 2277365) Primary rated current strength Ipn [A] Isn Cl. 500 600 750 800 1000 1250 1500 1600 2000 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 C05 5 5 5 5 5 5 = 0.5 10 IS01 Rated power Sn [VA] / Selection table PACT MCR-V2-8015-105 (Order No.: 2277352) Primary rated current strength Ipn [A] Isn Cl. 400 500 600 750 800 1000 1250 1500 1600 2000 2500 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 5 C05 5 5 5 5 5 5 5 5 10 = 0.5 10 10 7.5 10 10 10 15 IS01 15 15 20 =1 A 2.5 2.5 2.5 2.5 2.5 2.5 2.5 5 5 10 C10 5 5 5 5 5 5 5 10 10 15 =1 7.5 10 10 10 10 10 10 15 15 20 15 15 20 20 25 2.5 2.5 2.5 2.5 2.5 5 2.5 2.5 2.5 2.5 5 C05 5 5 5 5 5 10 5 5 5 5 10 = 0.5 10 10 10 15 10 10 10 10 15 IS05 15 15 20 15 15 20 =5A 2.5 2.5 2.5 2.5 5 5 2.5 2.5 5 5 10 C10 5 5 5 5 10 10 5 5 10 10 15 =1 7.5 10 10 10 15 15 10 10 15 15 20 15 20 15 20 30 60x64 16 116 Order No. 64x53 61 33x63 16x83 16 Type Technical data Input data Thermal rated short-time current Ith = 60 * In Rated surge current Idyn = 2.5 * Ith Rated frequency 50 Hz ... 60 Hz Surge current limitation factor FS 5 General data Rated insulation voltage 1 kV Test voltage 3 kV (50 Hz, 1 min.) Can be calibrated No Insulating material class E Connection capacity of secondary terminals 2 x (2.5 x 4) mm Ambient temperature (operation) -25°C ... 40°C Standards/regulations IEC 60044-1 Housing material Polyamide PA glass fiber reinforced Dimensions L / W / H 105 / 30 / 132 mm Dimensions (alternative assembly) L / B / H 30 / 105 / 132 mm Add to order key from the selection table (ordering example marked in orange) Order No. Primary current Ipn Secondary current Isn Class Rated power Sn 2277352 30 105 =1 A C10 =1 C05 = 0.5 IS05 =5A C10 =1 2.5 5 2.5 5 7.5 2.5 5 7.5 2.5 5 7.5 2.5 5 2.5 5 2.5 5 2.5 5 7.5 2.5 5 10 15 2.5 5 10 2.5 5 2.5 5 7.5 2.5 5 7.5 2.5 5 10 2.5 5 10 2.5 5 10 2.5 5 10 2.5 5 10 2.5 5 10 15 2.5 5 10 15 5 10 15 2.5 5 2.5 5 7.5 2.5 5 7.5 Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com 2.5 5 10 Rated power Sn [VA] Rated power Sn Description Plug-in current transformer 105 116 Note: Our configurator provides you with a convenient ordering option under www.phoenixcontact.de/eshop. PACT MCR-V2-8020-105 Plug-in current transformer Housing width 30 53x53 Due to their primary rail holder that can be pulled out, the PACT analog current transformers are suitable for horizontal and vertical installation. It is thus possible to place current transformers in parallel directly on the copper rail. This is particularly convenient in the case of spacecritical applications. PACT MCR-V2-8015-105 5 10 PHOENIX CONTACT 409 INTERFACE Analog PACT Analog Current transformers PACT MCR-V2-10020-129 – Primary rated current Ipn: 0...(400...4000) A – Round conductor dimensions: Ø 85 mm – Rail dimensions: 2x 100x10 mm; 80x64 mm PACT MCR-V2-10036-129 – Primary rated current Ipn: 0...(400...4000) A – Rail dimensions: 3x 100x12 mm Plug-in current transformer Housing width 30 Housing width 30 30 30 140 Type Order No. PACT MCR-V2-10020-129 2277378 Pcs. / Pkt. 56x101 85 140 64x84 31x101 16 129 16 129 Note: Our configurator provides you with a convenient ordering option under www.phoenixcontact.de/eshop. Description PACT MCR-V2-10036-129 Plug-in current transformer 81x54 Due to their primary rail holder that can be pulled out, the PACT analog current transformers are suitable for horizontal and vertical installation. It is thus possible to place current transformers in parallel directly on the copper rail. This is particularly convenient in the case of spacecritical applications. PACT MCR-V2-10020-129 Type Order No. PACT MCR-V2-10036-129 2277381 Pcs. / Pkt. Current transformers, pay attention to the following ordering key for determining the desired current transformer type Ith = 60 * In Idyn = 2.5 * Ith 50 Hz ... 60 Hz FS 5 1 kV 3 kV (50 Hz, 1 min.) No E 2 x (2.5 x 4) mm -25°C ... 40°C IEC 60044-1 Polyamide PA glass fiber reinforced 129 / 30 / 156 mm 30 / 129 / 156 mm 1 kV 3 kV (50 Hz, 1 min.) No E 2 x (2.5 x 4) mm -25°C ... 40°C IEC 60044-1 Polyamide PA glass fiber reinforced 129 / 30 / 156 mm 30 / 129 / 156 mm Add to order key from the selection table (ordering example marked in orange) Order No. Primary current Ipn Secondary current Isn Class / IP40000 / IS05 / C05 Rated power Sn / Selection table PACT MCR-V2-10020-129 (Order No.: 2277378) Primary rated current strength Ipn [A] Isn Cl. 400 500 600 750 800 1000 1250 1500 1600 2000 2500 3000 4000 2.5 5 5 5 5 5 5 5 5 5 5 C05 5 10 10 10 10 10 10 10 10 10 10 = 0.5 15 15 15 15 15 15 IS01 20 20 =1 A 2.5 2.5 5 5 5 5 5 5 5 5 5 5 C10 5 5 10 10 10 10 10 10 10 10 10 10 =1 15 15 15 15 15 15 25 30 2.5 2.5 5 5 5 5 5 5 5 5 5 5 C05 5 5 10 10 10 10 10 10 10 10 10 10 = 0.5 15 15 15 15 15 15 15 IS05 20 20 25 25 =5A 2.5 2.5 5 5 5 5 5 5 5 5 5 5 5 C10 5 5 10 10 10 10 10 10 10 10 10 10 10 =1 15 15 15 15 15 15 15 15 20 25 30 30 30 410 PHOENIX CONTACT 1 P2500 Selection table PACT MCR-V2-10036-129 (Order No.: 2277381) Primary rated current strength Ipn [A] Isn Cl. 400 500 600 750 800 1000 1250 1500 1600 2000 2500 3000 4000 2.5 5 5 5 5 5 5 5 5 5 5 C05 5 10 10 10 10 10 10 10 10 10 10 = 0.5 15 15 15 15 15 15 IS01 20 20 =1 A 2.5 2.5 5 5 5 5 5 5 5 5 5 5 C10 5 5 10 10 10 10 10 10 10 10 10 10 =1 15 15 15 15 15 15 25 30 2.5 2.5 5 5 5 5 5 5 5 5 5 5 C05 5 5 10 10 10 10 10 10 10 10 10 10 = 0.5 15 15 15 15 15 15 15 IS05 20 20 25 25 =5A 2.5 2.5 5 5 5 5 5 5 5 5 5 5 5 C10 5 5 10 10 10 10 10 10 10 10 10 10 10 =1 15 15 15 15 15 15 15 15 20 25 30 30 30 Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com Rated power Sn [VA] 2277378 1 Ith = 60 * In Idyn = 2.5 * Ith 50 Hz ... 60 Hz FS 5 Rated power Sn [VA] Technical data Input data Thermal rated short-time current Rated surge current Rated frequency Surge current limitation factor General data Rated insulation voltage Test voltage Can be calibrated Insulating material class Connection capacity of secondary terminals Ambient temperature (operation) Standards/regulations Housing material Dimensions L / W / H Dimensions (alternative assembly) L / B / H INTERFACE Analog PACT Analog Current transformers PACT MCR-V2-12020-159 – Primary rated current Ipn: 0...(400...4000) A – Round conductor dimensions: Ø 96 mm – Rail dimensions: 2x 120x10 mm; 3x 100x10 mm; 80x80 mm PACT MCR-V2-12040-159 – Primary rated current Ipn: 0...(400...4000) A – Rail dimensions: 4x 120x10 mm Plug-in current transformer Housing width 30 30 30 172 Type Order No. PACT MCR-V2-12020-159 2277394 Pcs. / Pkt. 72x122 96 55x103 172 34x126 16 159 16 159 Note: Our configurator provides you with a convenient ordering option under www.phoenixcontact.de/eshop. Description PACT MCR-V2-12040-159 Plug-in current transformer Housing width 30 83x83 Due to their primary rail holder that can be pulled out, the PACT analog current transformers are suitable for horizontal and vertical installation. It is thus possible to place current transformers in parallel directly on the copper rail. This is particularly convenient in the case of spacecritical applications. PACT MCR-V2-12020-159 Type Order No. PACT MCR-V2-12040-159 2277404 Pcs. / Pkt. Current transformers, pay attention to the following ordering key for determining the desired current transformer type Ith = 60 * In Idyn = 2.5 * Ith 50 Hz ... 60 Hz FS 5 1 kV 3 kV (50 Hz, 1 min.) No E 2 x (2.5 x 4) mm -25°C ... 40°C IEC 60044-1 Polyamide PA glass fiber reinforced 159 / 30 / 188 mm 30 / 159 / 188 mm 1 kV 3 kV (50 Hz, 1 min.) No E 2 x (2.5 x 4) mm -25°C ... 40°C IEC 60044-1 Polyamide PA glass fiber reinforced 159 / 30 / 188 mm 30 / 159 / 188 mm Add to order key from the selection table (ordering example marked in orange) Order No. Primary current Ipn Secondary current Isn Class / IP08000 / IS01 / C05 1 Rated power / Selection table PACT MCR-V2-12020-159 (Order No.: 2277394) Primary rated current strength Ipn [A] Isn Cl. 400 500 600 750 800 1000 1250 1500 1600 2000 2500 3000 4000 2.5 2.5 2.5 2.5 2.5 2.5 5 5 5 5 5 5 10 C05 5 5 5 5 5 5 10 10 10 10 10 10 15 = 0.5 10 10 10 10 10 10 15 15 15 15 15 15 30 IS01 15 20 30 30 30 30 30 45 =1 A 2.5 5 5 2.5 2.5 5 5 5 5 5 5 10 10 C10 5 10 10 5 5 10 10 10 10 10 10 15 15 =1 10 15 15 10 10 15 15 15 15 15 15 30 30 15 20 20 15 20 30 30 30 30 30 45 45 2.5 2.5 2.5 2.5 2.5 5 5 10 5 5 5 10 10 C05 5 5 5 5 5 10 10 15 10 10 10 15 15 = 0.5 10 10 10 10 10 15 15 30 15 15 15 30 30 IS05 15 15 30 30 45 30 30 30 45 45 =5A 2.5 5 5 5 5 5 5 10 5 5 10 10 10 C10 5 10 10 10 10 10 10 15 10 10 15 15 15 =1 10 15 15 15 15 15 15 30 15 15 30 30 30 15 20 20 20 30 30 30 45 30 30 45 45 45 P250 Selection table PACT MCR-V2-12040-159 (Order No.: 2277404) Primary rated current strength Ipn [A] Isn Cl. 400 500 600 750 800 1000 1250 1500 1600 2000 2500 3000 4000 2.5 2.5 2.5 2.5 2.5 2.5 5 5 5 5 5 5 10 C05 5 5 5 5 5 5 10 10 10 10 10 10 15 = 0.5 10 15 15 15 15 15 15 30 IS01 =1 A C10 =1 C05 = 0.5 IS05 =5A C10 =1 2.5 5 10 5 10 15 5 10 15 2.5 5 2.5 5 10 5 10 15 5 10 15 5 10 15 5 10 15 5 10 15 5 10 15 10 15 30 10 15 30 2.5 5 2.5 5 2.5 5 2.5 5 10 2.5 5 10 5 10 15 5 10 15 10 15 30 5 10 15 5 10 15 5 10 15 10 15 30 10 15 30 2.5 5 10 5 10 15 5 10 15 5 10 15 5 10 15 5 10 15 5 10 15 10 15 30 5 10 15 5 10 15 10 15 30 10 15 30 10 15 30 Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com PHOENIX CONTACT Rated power Sn [VA] 2277404 1 Ith = 60 * In Idyn = 2.5 * Ith 50 Hz ... 60 Hz FS 5 Rated power Sn [VA] Technical data Input data Thermal rated short-time current Rated surge current Rated frequency Surge current limitation factor General data Rated insulation voltage Test voltage Can be calibrated Insulating material class Connection capacity of secondary terminals Ambient temperature (operation) Standards/regulations Housing material Dimensions L / W / H Dimensions (alternative assembly) L / B / H 411 INTERFACE Analog PACT Analog Current transformers PACT MCR-V3-60 – Primary rated current Ipn: 0...(1...40) A 30 The PACT analog current transformer as winding current transformer has a special structure: the current-carrying copper lines are directly connected to the screw terminal blocks on the primary side. Depending on the transformation ratio, the output current can have higher values than the input current. 64 16 60 PACT MCR-V3-60 Winding current transformer Note: Our configurator provides you with a convenient ordering option under www.phoenixcontact.de/eshop. The relevant installation accessories can be found on page 419. Housing width 30 Description Type Order No. PACT MCR-V3- 60 2277417 Pcs. / Pkt. Current transformers, pay attention to the following ordering key for determining the desired current transformer type Technical data Input data Thermal rated short-time current Rated surge current Rated frequency Surge current limitation factor General data Rated insulation voltage Test voltage Can be calibrated Insulating material class Connection capacity of secondary terminals Ambient temperature (operation) Standards/regulations Housing material Dimensions L / W / H Dimensions (alternative assembly) L / B / H Ith = 60 * In Idyn = 2.5 * Ith 50 Hz ... 60 Hz FS 5 1 kV 3 kV (50 Hz, 1 min.) No E 2 x (2.5 x 4) mm -25°C ... 40°C IEC 60044-1 Polyamide PA glass fiber reinforced 60 / 30 / 80 mm 30 / 60 / 80 mm Add to order key from the selection table (ordering example marked in orange) Order No. Primary current Ipn Secondary current Isn Class / IP00025 / IS01 Selection table PACT MCR-V3-60 (Order No.: 2277417) Primary rated current strength Ipn [A] Isn Cl. 1 2 2.5 4 5 2.5 2.5 2.5 2.5 2.5 C05 5 5 5 5 5 = 0.5 IS01 =1 A 2.5 2.5 2.5 2.5 2.5 C10 5 5 5 5 5 =1 C05 = 0.5 IS05 =5A C10 =1 412 PHOENIX CONTACT / C10 Rated power Sn / P250 6 2.5 5 7.5 2.5 5 10 2.5 5 12.5 2.5 5 15 2.5 5 20 2.5 5 25 2.5 5 30 2.5 5 40 2.5 5 2.5 5 2.5 5 2.5 5 2.5 5 2.5 5 2.5 5 2.5 5 2.5 5 2.5 5 2.5 5 2.5 5 2.5 5 2.5 5 2.5 5 2.5 5 2.5 5 2.5 5 2.5 5 2.5 5 2.5 5 2.5 5 2.5 5 2.5 5 2.5 5 2.5 5 2.5 5 2.5 5 2.5 5 2.5 5 2.5 5 2.5 5 2.5 5 2.5 5 2.5 5 2.5 5 2.5 5 2.5 5 Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com Rated power Sn [VA] 2277417 1 INTERFACE Analog PACT Analog Current transformers that can be calibrated PACT MCR-V1C-21-44 – Primary rated current Ipn: 0...(150...500) A – Round conductor dimensions: Ø 21 mm PACT MCR-V2C_3015_60 – Primary rated current Ipn: 0...(200...750) A – Round conductor dimensions: Ø 28 mm – Rail dimensions: 30x15 mm; 20x20 mm PACT MCR-V2C-3015-60 Bus-bar current transformer Plug-in current transformer Housing width 30 Housing width 30 30 30 60 28 23x23 26 50 21 64 Note: Our configurator provides you with a convenient ordering option under www.phoenixcontact.de/eshop. The relevant installation accessories can be found on page 419. 16x33 16 16 44 33x16 PACT analog current transformers have to undergo a type approval test after the successful completion of which they may be calibrated. The current transformers that can be calibrated become calibrated only after an additional calibration process is executed. PACT MCR-V1C-21-44 Description Type Order No. PACT MCR-V1C-21-44 2277420 Pcs. / Pkt. Type Order No. PACT MCR-V2C-3015-60 2277433 Pcs. / Pkt. Current transformers, pay attention to the following ordering key for determining the desired current transformer type Ith = 60 * In Idyn = 2.5 * Ith 50 Hz FS 5 Ith = 60 * In Idyn = 2.5 * Ith 50 Hz FS 5 1 kV 3 kV (50 Hz, 1 min.) Yes E 2 x (2.5 x 4) mm -25°C ... 40°C IEC 60044-1 Polyamide PA glass fiber reinforced 44 / 30 / 66 mm 30 / 44 / 66 mm 1 kV 3 kV (50 Hz, 1 min.) Yes E 2 x (2.5 x 4) mm -25°C ... 40°C IEC 60044-1 Polyamide PA glass fiber reinforced 60 / 30 / 80 mm 30 / 60 / 80 mm Add to order key from the selection table (ordering example marked in orange) Order No. Primary current Ipn Secondary current Isn Class / IP03000 / IS05 2277420 = PACT MCR-V1C-21-44 / IS05 = 5 A Selection table PACT MCR-V1C-21-44 (Order No.: 2277420) Primary rated current strength Ipn [A] Isn Cl. 150 200 250 300 400 500 2.5 2.5 2.5 5 5 5 0.2 5A 2.5 0.5 2.5 5 2.5 5 2.5 5 10 2.5 5 2.5 5 10 C02 Rated power Sn / P250 P500 P1000 P1500 C02 = 0.2 C05 = 0.5 Rated power Sn [VA] 2277420 1 = = = = Calibration P250 2.5 VA 5.0 VA 10 VA 15 VA / Certificate of calibration NONE / NONE = Not calibrated YES = Calibrated Selection table PACT MCR-V2C-3015-60 (Order No.: 2277433) Primary rated current strength Ipn [A] Isn Cl. 200 250 300 400 500 600 750 2.5 2.5 2.5 2.5 5 5 5 0.2 10 10 5A 2.5 0.5 2.5 5 2.5 5 2.5 5 10 2.5 5 10 2.5 5 10 1 2.5 5 10 15 Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com NONE = No certificate of calibration = Certificate of calibration (at a charge) YESPLUS = Certificate of calibration with catalog of errors (five measuring points) (at a charge) NONE YES Rated power Sn [VA] Technical data Input data Thermal rated short-time current Rated surge current Rated frequency Surge current limitation factor General data Rated insulation voltage Test voltage Can be calibrated Insulating material class Connection capacity of secondary terminals Ambient temperature (operation) Standards/regulations Housing material Dimensions L / W / H Dimensions (alternative assembly) L / B / H PHOENIX CONTACT 413 INTERFACE Analog PACT Analog Current transformers that can be calibrated PACT MCR-V2C-4012-70 – Primary rated current Ipn: 0...(200...1000) A – Round conductor dimensions: Ø 33 mm – Rail dimensions: 40x12 mm; 2x 30x10 mm PACT MCR-V2C-5012-85 – Primary rated current Ipn: 0...(200...1200) A – Round conductor dimensions: Ø 42 mm – Rail dimensions: 50x12 mm; 2x 40x10 mm PACT MCR-V2C-5012- 85 Plug-in current transformer Plug-in current transformer Housing width 30 Housing width 30 30 30 85 33 13x50,5 42 2277446 41x31 PACT MCR-V2C- 4012- 70 Pcs. / Pkt. 31x41 Order No. 92 Type 50,5x13 Description 31x31 Note: Our configurator provides you with a convenient ordering option under www.phoenixcontact.de/eshop. 74 13x40,5 16 16 70 40,5x13 PACT analog current transformers have to undergo a type approval test after the successful completion of which they may be calibrated. The current transformers that can be calibrated become calibrated only after an additional calibration process is executed. PACT MCR-V2C-4012- 70 Type Order No. PACT MCR-V2C- 5012- 85 2277459 Pcs. / Pkt. Current transformers, pay attention to the following ordering key for determining the desired current transformer type Ith = 60 * In Idyn = 2.5 * Ith 50 Hz FS 5 Ith = 60 * In Idyn = 2.5 * Ith 50 Hz FS 5 1 kV 3 kV (50 Hz, 1 min.) Yes E 2 x (2.5 x 4) mm -25°C ... 40°C IEC 60044-1 Polyamide PA glass fiber reinforced 70 / 30 / 90 mm 30 / 70 / 90 mm 1 kV 3 kV (50 Hz, 1 min.) Yes E 2 x (2.5 x 4) mm -25°C ... 40°C IEC 60044-1 Polyamide PA glass fiber reinforced 85 / 30 / 108 mm 30 / 85 / 108 mm Add to order key from the selection table (ordering example marked in orange) Order No. Primary current Ipn Secondary current Isn Class / IP10000 / IS05 2277459 = PACT MCR-V2C-5012-85 / IS05 = 5 A C02 = 0.2 C05 = 0.5 Selection table PACT MCR-V2C-4012-70 (Order No.: 2277446) Primary rated current strength Ipn [A] Isn Cl. 200 250 300 400 500 600 750 800 2.5 2.5 2.5 5 2.5 5 5 5 10 5 0.2 10 10 10 1000 5 10 5A 2.5 0.5 414 2.5 5 2.5 5 PHOENIX CONTACT 2.5 5 10 2.5 5 10 5 10 5 10 C05 2.5 5 10 5 10 Rated power Sn [VA] 2277459 1 Rated power Sn / P250 P500 P1000 P1500 P3000 = = = = = Calibration P1500 2.5 VA 5.0 VA 10 VA 15 VA 30 V A / Certificate of calibration NONE / NONE = No certificate of calibration = Certificate of calibration (at a charge) YESPLUS = Certificate of calibration with catalog of errors (five measuring points) (at a charge) NONE YES NONE = Not calibrated YES = Calibrated Selection table PACT MCR-V2C-5012-85 (Order No.: 2277459) Primary rated current strength Ipn [A] Isn Cl. 200 250 300 400 500 600 750 800 2.5 2.5 2.5 2.5 2.5 5 5 5 5 5 0.2 10 10 10 5A 2.5 0.5 2.5 5 2.5 5 2.5 5 10 2.5 5 10 5 10 Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com 5 10 5 10 1000 5 10 15 30 5 10 15 30 1200 5 10 15 30 5 10 15 30 Rated power Sn [VA] Technical data Input data Thermal rated short-time current Rated surge current Rated frequency Surge current limitation factor General data Rated insulation voltage Test voltage Can be calibrated Insulating material class Connection capacity of secondary terminals Ambient temperature (operation) Standards/regulations Housing material Dimensions L / W / H Dimensions (alternative assembly) L / B / H 1 INTERFACE Analog PACT Analog Current transformers that can be calibrated PACT MCR-V2C-6015-85 – Primary rated current Ipn: 0...(250...1200) A – Round conductor dimensions: Ø 52 mm – Rail dimensions: 60x15 mm; 2x 50x10 mm; 40x40 mm PACT MCR-V2C-6015-95 – Primary rated current Ipn: 0...(200...1500) A – Round conductor dimensions: Ø 53 mm – Rail dimensions: 60x15 mm; 2x 50x10 mm; 40x40 mm PACT MCR-V2C-6015- 95 Plug-in current transformer Plug-in current transformer Housing width 30 Housing width 30 95 30 30 52 53 16x64 2277462 32x54 PACT MCR-V2C-6015- 85 Pcs. / Pkt. 54x32 Order No. 42x42 Type 105 Description 64x16 42x42 32x52 Note: Our configurator provides you with a convenient ordering option under www.phoenixcontact.de/eshop. 92 52x32 16x60,5 16 16 85 60,5x16 PACT analog current transformers have to undergo a type approval test after the successful completion of which they may be calibrated. The current transformers that can be calibrated become calibrated only after an additional calibration process is executed. PACT MCR-V2C-6015- 85 Type Order No. PACT MCR-V2C- 6015- 95 2277475 Pcs. / Pkt. Current transformers, pay attention to the following ordering key for determining the desired current transformer type Ith = 60 * In Idyn = 2.5 * Ith 50 Hz FS 5 Ith = 60 * In Idyn = 2.5 * Ith 50 Hz FS 5 1 kV 3 kV (50 Hz, 1 min.) Yes E 2 x (2.5 x 4) mm -25°C ... 40°C IEC 60044-1 Polyamide PA glass fiber reinforced 85 / 30 / 108 mm 30 / 85 / 108 mm 1 kV 3 kV (50 Hz, 1 min.) Yes E 2 x (2.5 x 4) mm -25°C ... 40°C IEC 60044-1 Polyamide PA glass fiber reinforced 95 / 30 / 121 mm 30 / 95 / 121 mm Add to order key from the selection table (ordering example marked in orange) Order No. Primary current Ipn Secondary current Isn Class / IP02500 / IS05 2277462 = PACT MCR-V2C-6015-85 / IS05 = 5 A 5A 2.5 2.5 2.5 2.5 5 2.5 5 2.5 5 10 2.5 5 10 / C02 = 0.2 C05 = 0.5 Selection table PACT MCR-V2C-6015-85 (Order No.: 2277462) Primary rated current strength Ipn [A] Isn Cl. 250 300 400 500 600 750 800 1000 2.5 2.5 2.5 2.5 5 5 5 0.2 10 0.5 Rated power Sn C05 2.5 5 10 15 1200 2.5 5 10 15 2.5 5 10 15 Rated power Sn [VA] 2277462 1 P250 P500 P1000 P1500 P2000 P3000 = = = = = = P250 2.5 VA 5.0 VA 10 VA 15 VA 20 V A 30 V A Calibration / NONE NONE = Not calibrated YES = Calibrated Certificate of calibration / NONE = No certificate of calibration = Certificate of calibration (at a charge) YESPLUS = Certificate of calibration with catalog of errors (five measuring points) (at a charge) NONE YES Selection table PACT MCR-V2C-6015-95 (Order No.: 2277475) Primary rated current strength Ipn [A] Isn Cl. 200 250 300 400 500 600 750 800 1000 2.5 2.5 2.5 2.5 2.5 5 5 5 5 5 5 10 0.2 10 10 10 15 15 15 20 5A 2.5 2.5 2.5 2.5 2.5 2.5 5 5 5 5 5 5 5 5 10 10 10 0.5 10 10 10 15 15 15 15 15 15 20 30 30 Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com 1 1200 5 10 15 20 5 10 15 20 1250 5 10 15 20 5 10 15 30 1500 5 10 15 30 5 10 15 30 Rated power Sn [VA] Technical data Input data Thermal rated short-time current Rated surge current Rated frequency Surge current limitation factor General data Rated insulation voltage Test voltage Can be calibrated Insulating material class Connection capacity of secondary terminals Ambient temperature (operation) Standards/regulations Housing material Dimensions L / W / H Dimensions (alternative assembly) L / B / H PHOENIX CONTACT 415 INTERFACE Analog PACT Analog Current transformers that can be calibrated PACT MCR-V2C-6040-96 – Primary rated current Ipn: 0...(500...1500) A – Round conductor dimensions: Ø 61 mm – Rail dimensions: 60x40 mm; 50x50 mm PACT MCR-V2C-8015-105 – Primary rated current Ipn: 0...(400...1500) A – Round conductor dimensions: Ø 61 mm – Rail dimensions: 80x15 mm; 2x 60x10 mm; 3x 50x10 mm Plug-in current transformer Housing width 30 Housing width 30 96 30 30 16 105 Order No. PACT MCR-V2C- 6040- 96 2277488 Pcs. / Pkt. 61 33x63 116 Type 53x53 61 44x64 16x83 16 105 Note: Our configurator provides you with a convenient ordering option under www.phoenixcontact.de/eshop. Description PACT MCR-V2C-8015-105 Plug-in current transformer 54x54 PACT analog current transformers have to undergo a type approval test after the successful completion of which they may be calibrated. The current transformers that can be calibrated become calibrated only after an additional calibration process is executed. PACT MCR-V2C-6040- 96 Type Order No. PACT MCR-V2C-8015-105 2277491 Pcs. / Pkt. Current transformers, pay attention to the following ordering key for determining the desired current transformer type Ith = 60 * In Idyn = 2.5 * Ith 50 Hz FS 5 Ith = 60 * In Idyn = 2.5 * Ith 50 Hz FS 5 1 kV 3 kV (50 Hz, 1 min.) Yes E 2 x (2.5 x 4) mm -25°C ... 40°C IEC 60044-1 Polyamide PA glass fiber reinforced 96 / 30 / 121 mm 30 / 96 / 121 mm 1 kV 3 kV (50 Hz, 1 min.) Yes E 2 x (2.5 x 4) mm -25°C ... 40°C IEC 60044-1 Polyamide PA glass fiber reinforced 105 / 30 / 132 mm 30 / 105 / 132 mm Add to order key from the selection table (ordering example marked in orange) Order No. Primary current Ipn Secondary current Isn Class / IP12000 2277488 = PACT MCR-V2C-6040-96 / IS05 / IS05 = 5 A Selection table PACT MCR-V2C-6040-96 (Order No.: 2277488) Primary rated current strength Ipn [A] Isn Cl. 500 600 750 800 1000 1200 1250 1500 2.5 2.5 2.5 2.5 2.5 2.5 5 5 5 5 5 5 0.2 10 10 15 5A 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 5 5 5 5 5 5 5 5 0.5 10 10 10 10 10 10 15 15 416 PHOENIX CONTACT Rated power Sn C02 / C02 = 0.2 C05 = 0.5 Rated power Sn [VA] 2277488 1 P250 P500 P1000 P1500 P2000 = = = = = P1000 2.5 VA 5.0 VA 10 VA 15 VA 20 V A Calibration / NONE NONE = Not calibrated YES = Calibrated Certificate of calibration / NONE = No certificate of calibration = Certificate of calibration (at a charge) YESPLUS = Certificate of calibration with catalog of errors (five measuring points) (at a charge) NONE YES Selection table PACT MCR-V2C-8015-105 (Order No.: 2277491) Primary rated current strength Ipn [A] Isn Cl. 400 500 600 750 800 1000 1200 1250 2.5 2.5 2.5 2.5 2.5 2.5 5 5 5 5 5 5 0.2 10 10 10 10 10 15 5A 2.5 2.5 2.5 2.5 2.5 5 2.5 2.5 5 5 5 5 5 10 5 5 0.5 10 10 10 15 10 10 15 15 20 Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com 1500 2.5 5 10 15 2.5 5 10 15 Rated power Sn [VA] Technical data Input data Thermal rated short-time current Rated surge current Rated frequency Surge current limitation factor General data Rated insulation voltage Test voltage Can be calibrated Insulating material class Connection capacity of secondary terminals Ambient temperature (operation) Standards/regulations Housing material Dimensions L / W / H Dimensions (alternative assembly) L / B / H 1 INTERFACE Analog PACT Analog Current transformers that can be calibrated PACT MCR-V2C-8020-105 – Primary rated current Ipn: 0...(400...1500) A – Round conductor dimensions: Ø 70 mm – Rail dimensions: 2x 80x10 mm; 60x60 mm PACT MCR-V2C-10020-129 – Primary rated current Ipn: 0...(500...2500) A – Round conductor dimensions: Ø 85 mm – Rail dimensions: 2x 100x10 mm; 80x64 mm Description Plug-in current transformer Housing width 30 Housing width 30 30 30 129 Order No. PACT MCR-V2C-8020-105 2277501 Pcs. / Pkt. 85 64x84 140 Type 81x54 70 31x81 60x64 31x101 16 16 105 116 Note: Our configurator provides you with a convenient ordering option under www.phoenixcontact.de/eshop. PACT MCR-V2C-10020-129 Plug-in current transformer 64x53 PACT analog current transformers have to undergo a type approval test after the successful completion of which they may be calibrated. The current transformers that can be calibrated become calibrated only after an additional calibration process is executed. PACT MCR-V2C-8020-105 Type Order No. PACT MCR-V2C-10020-129 2277514 Pcs. / Pkt. Current transformers, pay attention to the following ordering key for determining the desired current transformer type Ith = 60 * In Idyn = 2.5 * Ith 50 Hz FS 5 Ith = 60 * In Idyn = 2.5 * Ith 50 Hz FS 5 1 kV 3 kV (50 Hz, 1 min.) Yes E 2 x (2.5 x 4) mm -25°C ... 40°C IEC 60044-1 Polyamide PA glass fiber reinforced 105 / 30 / 132 mm 30 / 105 / 132 mm 1 kV 3 kV (50 Hz, 1 min.) Yes E 2 x (2.5 x 4) mm -25°C ... 40°C IEC 60044-1 Polyamide PA glass fiber reinforced 129 / 30 / 156 mm 30 / 129 / 156 mm Add to order key from the selection table (ordering example marked in orange) Order No. Primary current Ipn Secondary current Isn Class / IP08000 / IS05 2277514 = PACT MCR-V2C-10020-129 / IS05 = 5 A 5A 2.5 5 2.5 5 2.5 5 2.5 5 2.5 5 10 2.5 5 10 2.5 5 10 / C02 = 0.2 C05 = 0.5 Selection table PACT MCR-V2C-8020-105 (Order No.: 2277501) Primary rated current strength Ipn [A] Isn Cl. 400 500 600 750 800 1000 1200 1250 1500 2.5 2.5 2.5 2.5 2.5 2.5 2.5 5 5 5 5 0.2 10 10 10 0.5 Rated power Sn C05 2.5 5 10 2.5 5 10 Rated power Sn [VA] 2277514 1 P250 P500 P1000 P1500 = = = = P1500 2.5 VA 5.0 VA 10 VA 15 VA Calibration / NONE NONE = Not calibrated YES = Calibrated Certificate of calibration / NONE = No certificate of calibration = Certificate of calibration (at a charge) YESPLUS = Certificate of calibration with catalog of errors (five measuring points) (at a charge) NONE YES Selection table PACT MCR-V2C-10020-129 (Order No.: 2277514) Primary rated current strength Ipn [A] Isn Cl. 500 600 750 800 1000 1200 1250 1500 2.5 2.5 2.5 2.5 5 5 5 5 0.2 10 10 10 10 15 15 5A 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 5 5 5 5 5 5 5 5 0.5 10 10 10 10 10 10 15 15 15 15 15 Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com 1 1600 2.5 5 10 15 2.5 5 10 15 2000 2.5 5 10 15 2.5 5 10 15 2500 2.5 5 10 15 2.5 5 10 15 Rated power Sn [VA] Technical data Input data Thermal rated short-time current Rated surge current Rated frequency Surge current limitation factor General data Rated insulation voltage Test voltage Can be calibrated Insulating material class Connection capacity of secondary terminals Ambient temperature (operation) Standards/regulations Housing material Dimensions L / W / H Dimensions (alternative assembly) L / B / H PHOENIX CONTACT 417 INTERFACE Analog PACT Analog Current transformers that can be calibrated PACT MCR-V2C-10039-129 – Primary rated current Ipn: 0...(500...2500) A – Rail dimensions: 3x 100x12 mm 30 Note: Our configurator provides you with a convenient ordering option under www.phoenixcontact.de/eshop. The relevant installation accessories can be found on page 419. 140 PACT analog current transformers have to undergo a type approval test after the successful completion of which they may be calibrated. The current transformers that can be calibrated become calibrated only after an additional calibration process is executed. 56x101 16 129 PACT MCR-V2C-10036-129 Plug-in current transformer Housing width 30 Description Type Order No. PACT MCR-V2C-10036-129 2277527 Pcs. / Pkt. Current transformers, pay attention to the following ordering key for determining the desired current transformer type Technical data Input data Thermal rated short-time current Rated surge current Rated frequency Surge current limitation factor General data Rated insulation voltage Test voltage Can be calibrated Insulating material class Connection capacity of secondary terminals Ambient temperature (operation) Standards/regulations Housing material Dimensions L / W / H Dimensions (alternative assembly) L / B / H Ith = 60 * In Idyn = 2.5 * Ith 50 Hz FS 5 1 kV 3 kV (50 Hz, 1 min.) Yes E 2 x (2.5 x 4) mm -25°C ... 40°C IEC 60044-1 Polyamide PA glass fiber reinforced 129 / 30 / 156 mm 30 / 129 / 156 mm Add to order key from the selection table (ordering example marked in orange) Order No. Primary Secondary Class Rated power Sn Calibration current Ipn current Isn / IP16000 / 2277527 = PACT MCRV2C-10036-129 IS05 IS05 = 5 A / C05 C02 = 0.2 C05 = 0.5 / P500 P250 = 2.5 VA P500 = 5.0 VA P1000 = 10 VA P1500 = 15 VA Selection table PACT MCR-V2C-10036-129 (Order No.: 2277527) Primary rated current strength Ipn [A] Isn Cl. 500 600 750 800 1000 1200 1250 1500 2.5 2.5 2.5 2.5 5 5 5 5 0.2 10 10 10 10 15 5A 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 5 5 5 5 5 5 5 5 0.5 10 10 10 10 10 10 15 15 418 PHOENIX CONTACT 1600 2.5 5 10 15 2.5 5 10 15 Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com / NONE / NONE = Not calibrated Certificate of calibration NONE YES YES = Calibrated 2000 2.5 5 10 15 2.5 5 10 15 2500 2.5 5 10 15 2.5 5 10 15 Rated power Sn [VA] 2277527 1 NONE = No certificate of calibration = Certificate of calibration (at a charge) YESPLUS = Certificate of calibration with catalog of errors (five measuring points) (at a charge) INTERFACE Analog PACT Analog PACT analog current transformer Accessories – Copper sleeves – Secondary terminal cover PACT MCR-CB-... Description Type Order No. PACT MCR-CB-21- 8 PACT MCR-CB-21-12 PACT MCR-CB-28-12 PACT MCR-CB-42-12 2277569 2277556 2277543 2277530 PACT MCR-ETC-... Pcs. / Pkt. Type Order No. PACT MCR-ETC-60 PACT MCR-ETC-75 2277572 2277585 Pcs. / Pkt. Copper sleeves, for establishing a conductive connection during the horizontal assembly of PACT analog current transformers. The size of the copper sleeve depends on the diameter of the inner hole of the current transformer. - for PACT MCR-V1-21-44-... Ø 21/8 mm - for PACT MCR-V1-21-44-... Ø 21/12 mm - for PACT MCR-V2-3015-60-... Ø 28/12 mm - for PACT MCR-V2-5012-85-... Ø 42/12 mm Secondary terminal cover, for increasing the clearances and creepage distances - for PACT MCR-V1-21-44-... Length: 60 mm - for PACT MCR-V2-3015-60-... Length: 75 mm and PACT MCR-V2-5012-85-... 1 1 1 1 9 9 PACT analog current transformer Accessories – DIN rail adapter – Insulating caps PACT MCR-RA Description PACT MCR-ICAP Type Order No. Pcs. / Pkt. PACT MCR-RA 2277598 12 Type Order No. Pcs. / Pkt. PACT MCR-ICAP 2277608 18 DIN rail adapter Insulating caps, for protection against unintended contact with mounting screws of the primary rail Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com PHOENIX CONTACT 419