Survey
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Filtered and non-filtered power supplies Legrand’s new filtered and non-filtered power supplies offer the same space saving benefits as the other ranges... and just like them, they are quick to install and are laser engraved for clear and permanent identification. Green output LED Rapid fixing on to rail (Up to 120 W) Primary voltage adjustment : ± 15 V ± 2 Fuse protection on output Twin output terminals for ease of connection Modular filtered version also available filtered and non-filtered power supplies filtered and non-filtered power supplies single phase single phase ■ Technical information (additional information p. 17-18) Cat. Nos. 0470 01/02/03/04/20/21/22/23/24/25/51/52/53/54 and 55 Conform to IEC/EN 61558-2-6 UL 60950 (up to 10 A) CAN/CSA C22.22 N° 60 950.00 Filtered products are compatible with EN 61131-2, EN 60204 and EN 60439-1 apparatus 0470 24 0470 53 Cat. Nos. 0047 95/97 and 98 Conform to IEC/EN 61558-2-6 Products are compatible with EN 61131-2, EN 60204 and EN 60439-1 apparatus 0047 98 Technical information (opposite and p. 17-18) ■ Dimensions Filtered power supplies for PLCs and other equipment requiring a voltage of 12 V DC or 24 V DC Non-filtered power supplies for installations requiring a 24 V DC voltage Include : • twin output terminals for ease of connection • safety transformer with electrostatic screen except Cat. Nos. marked(1) • fuse protection on output (except modular) • green LED output voltage indicator • capacitor in filtered range • PTC thermal protection on output (modular only) • class II when installed with approved protection (modular only) Supplied with a connection link for quick connection between - and up to 15 A (except modular) Cat. Nos. A (mm) Width 0470 01 68 98 88 0470 02 93 121 105 0470 03 105 135 115 0470 04 126 186 0470 20 68 98 0470 21 68 98 88 0470 22 93 121 105 0470 23 105 135 115 0470 24 126 186 0470 25 126 206 0470 51 68 98 T Pack Cat. Nos. Single phase filtered = 12 V output 230-400 V ± 15 V ± (input) / 12 V= (output) (mm2) 1 1 1 1 0470 01(1) 0470 02(1) 0470 03 0470 04 Power (W) Terminal capacity Flexible cable Input Output Current rating (A) 12 30 60 120 1 2·5 5 10 = 6 6 6 6 6 6 6 6 24 V output 230-400 V ± 15 V 1 1 1 1 1 1 ± (input) / 24 V= (output) Input 230-400 V Power (W) Current rating (A) 0470 20(1) 0470 21(1) 0470 22(1) 0470 23 0470 24 0470 25 12 24 60 120 240 360 0·5 1 2·5 5 10 15 Ø (mm) Weight (Kg) DIN – 1·00 45 x 94 4·6 2·45 45 x 104 4·6 3·60 175 75 x 150 5·5 6·35 88 DIN – 1·00 DIN – 1·00 45 x 94 4·6 2·45 45 x 104 4·6 3·60 175 75 x 150 5·5 6·35 175 75 x 150 5·5 7·60 88 DIN – 1·00 93 106 105 45 x 94 4·6 1·70 0470 53 105 135 115 45 x 104 4·6 3·40 0470 54 126 186 175 75 x 150 5·5 6·10 0470 55 126 206 175 75 x 150 5·5 7·30 0047 95 89 66 95 DIN – 1·00 0047 97 89 66 95 DIN – 1·00 0047 98 89 66 95 DIN – 1·00 Single phase filtered 6 6 6 6 6 6 A B G C F Single phase non-filtered = = ± 24 V output 230-400 V ± 15 V (input) 24 V (output) 24 60 120 240 360 1 2·5 5 10 15 Single phase non-filtered Terminal capacity (mm2) Flexible cable Input Output 6 6 6 6 6 6 6 6 6 6 A F Single phase filtered modular ± Input 230 V 1 0047 95 Power (W) Current rating (A) 15 1·25 24 V output 230 ± 15 V (input) / 24 V = ± Input 230 V 1 1 0047 97(1) 0047 98 Power (W) 12 21·5 Current rating (A) 0·5 0·9 = (output) Terminal capacity (mm2) Flexible cable Input Output 6 G G F C C A Single phase linear modular 60 44 6 = (output) Terminal capacity (mm2) Flexible cable Input Output 6 6 C = 12 V output 230 ± 15 V (input) / 12 V A B 0470 51(1) 0470 52(1) 0470 53 0470 54 0470 55 Current rating (A) F C 45 1 1 1 1 1 Power (W) G B Input 230-400 V F x G (mm) Fixing ctrs 0470 52 Terminal capacity (mm2) Flexible cable Input Output 6 6 6 6 6 6 C (mm) Height B Input 230-400 V B (mm) Depth 6 6 A B (1) Without screen, separation and attenuation by dividing flange between windings 9 filtered power supplies open type single phase ■ Cat. Nos. 0470 01/02/03/04/20/21/22/23/24 and 25 ■ Circuit protection (double pole MCB) Conform to IEC/EN 61558-2-6 UL 60950 (up to 10 A) CAN/CSA C22.22 N° 60 950.00 Products are compatible with EN 61131-2, EN 60204 and EN 60439-1 apparatus Single phase U = ± = 4 Internal 0·5 A Internal MCB/Fuse T 0·5 A L(1) Power supply CTP MCB/Fuse CTP MCB/Fuse T 1 A L(1) Power supply 1·25 A MCB/Fuse MCB/Fuse 10 A 0470 21 0069 12 (1 A) CTP 4 15 A 0069 12 (1 A) 0069 13 (2 A) 0470 02 T 2·5 A L(1) MCB/Fuse MCB/Fuse 0470 22 0069 14 (3 A) T 2·5 A L(1) 0470 03 T 5 A L(1) 0069 16 (6 A) 0470 04 T 10 A L(1) 0069 14 (3 A) 0470 23 T 5 A L(1) 0069 16 (16 A) 0470 24 0069 18 (10 A) Power supply = T 1 A L(1) 0047 95(2) Power supply 2·5 A 0069 12 (1 A) 0470 01 Power supply Input voltage : 230 V ±15 V single phase 50/60 Hz Output voltage : 12 V or 24 V Ripple factor : <5 % PTC thermal protection on output Insulation : Class II after enclosing behind insulated modular protection Fix to symmetrical rail 7·5 mm or 15 mm depth EN 50022 (5 x 17·5 mm modules) 0069 12 (1 A) 0047 98(2) Power supply 1A 0069 12 (1 A) 0047 97(2) MCB/Fuse 0·9 A External 0470 20 Power supply 5A Conform to IEC/EN 61558-2-6 Products are compatible with EN 61131-2, EN 60204 and EN 60439-1 apparatus External Power supply Power supply ■ Cat. Nos. 0047 95/97 and 98 24 V Protection P Input voltage : 230/400 V ±15 V single phase 50/60 Hz - Class I Output voltage : 12 V or 24 V Insulation voltage : Input/Output 4 510 V Input/Earth 2 260 V Output/Earth 500 V Max. ambient temperature without derating : 60 °C Ripple factor : <3 % filtered Cooling by natural convection Integral fuse protection on output All except Cat. Nos. 0470 04/24 and 25 can be fixed to symmetrical rail 7·5 mm or 15 mm depth EN 50022 Screw fix only Cat. Nos. 0470 04/24 and 25 Screw fix or clip on to DIN rail Cat. Nos. 0470 02/03/04,22 and 23 Supplied with a connection link for quick connection between terminals and earth up to 15 A ±= Input 230/400 V ±15 V 12 V T 10 A L(1) 0069 18 (10 A) 0470 25 MCB/Fuse 0133 16(3) 0069 20 (16 A) (1) T type fuse is a time delay fuse (5 x 20 mm) (2) Filtered modular power supply (3) Type gG fuse 10 x 38 mm ■ Operating diagram Operating current up to 15 A 400 V 230 V -15 V 0 +15 V + + ■ Electrical characteristics Filtered Cat. Nos. Voltage (V) Current rating (A) Weight (Kg) Input under load 230 V (A) Input under load 400 V (A) Operating voltage No-load Underload (V) With 100 mA load and input voltage +10% With nominal load input voltage –15% No-load loss (W) (V) Total loss at nominal load 100 % (W) Voltage drop (%) Output 12 V 0470 01 12 1 1 0·12 0·06 14·4 11·7 15·5 10·3 4·4 7·3 23·5 0470 02 12 2·5 2·45 0·33 0·19 13·9 11·6 15·2 10·2 8·3 11·9 19·4 0470 03 12 5 3·6 0·60 0·34 14·1 12·1 15·5 10·5 11·4 17·1 17·2 0470 04 12 10 6·35 1·24 0·72 14·7 11·8 16·1 10·4 20·2 33·7 24·7 Output 24 V 0470 20 24 0·5 1 0·12 0·06 27·6 22·9 29·4 20·1 4·4 7·3 20·66 0470 21 24 1 1 0·18 0·10 29·0 22·8 31·2 20·2 4·4 10·3 27·03 0470 22 24 2·5 2·45 0·47 0·27 27·8 23·3 30·4 20·4 8·3 16·3 19·46 0470 23 24 5 3·6 0·88 0·51 27·5 23·2 30·2 20·3 11·4 25·4 18·68 0470 24 24 10 6·35 1·88 1·09 27·7 23·5 30·5 20·5 20 45·3 18·20 0470 25 24 15 7·6 2·53 1·46 27·5 23·2 30·2 20·2 23 54·7 18·70 – No-load Underload (V) Total loss at nominal load 100 % (W) Voltage drop (%) Filtered modular Operating voltage Weight (V) Current rating (A) (Kg) Input under load 230 V (A) 0047 95 12 1·3 1 0·15 – 0047 97 24 0·5 1 0·13 – 0047 98 24 0·9 1 0·17 – Cat. Nos. Voltage (V) With 100 mA load load input voltage +10% With nominal load input voltage –15% No-load loss (W) 15·1 11·8 16·3 10·4 3·4 8·7 28·9 23·6 30·6 20·7 3·4 7·1 22·3 29·9 22·8 32·0 20·3 3·4 10·4 31·0 28·5 17