* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download CH2O/M-10 - membrapor
UniPro protocol stack wikipedia , lookup
Index of electronics articles wikipedia , lookup
Analog-to-digital converter wikipedia , lookup
Immunity-aware programming wikipedia , lookup
Valve RF amplifier wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Rectiverter wikipedia , lookup
SPECIFICATION SHEET CH2O/M-10 Formaldehyde Gas Sensor in Mini Housing MEASUREMENT Inboard Filter none Output Signal Resolution (Electronics dependent) T60 Response Time Typical Baseline Range (pure air, 20°C) Maximum Zero Shift (+20°C to +40°C) Repeatability Output Linearity Gain 4600 ± 1200 nA/ppm < 0.1 ppm Miniature-Size Outline Dimensions BOTTOM VIEW SIDE VIEW Reference < 40 sec Counter 90° -0.1 ppm to 0.1 ppm 18 mm 0.25 ppm < 2 % of signal Linear ‒ MECHANICAL Rec. Load Resistor 10 Ohm Bias Voltage not recommended Conformity to RoHS directive RoHS Compliance Weight Position Sensitivity ENVIRONMENTAL APPLICATIONS Temperature Range Pressure Range Pressure Coefficient Humidity Effect Warranty Period 5 mm Pin Projection 1.5 mm Pins on 13.5 mm PCD 5.5 g None 15 % to 90 % R.H. noncondensing -20 °C to 50 °C Atmospheric ± 10% N.D. Abrupt changes in humidity cause a short-term signal Continuous Air Quality Monitoring Safety and Environmental Control For Portable Devices 2 years in air H₂ CO Organic solvents LIFETIME Expected Operation Life Expected Long Term Output Drift in air Filter Life Storage Life Rec. Storage Temperature 13.5 mm PCD ± 0.10 mm ELECTRICAL Relative Humidity Range 20 mm Sensing 15.7 mm 3-Electrode Electrochemical 0 ‒ 10 ppm 30 ppm 16.4 mm Operation Principle Nominal Range Maximum Overload CROSS-SENSITIVITY DATA The table below does not claim to be complete. Interfering Gas Cross-Sens. % < 2 % per month ‒ 6 months in container 5 °C – 20 °C 12 months from date of dispatch 1%-3% 10 % - 18 % IMPORTANT NOTE Performance data conditions: 20 °C, 50% RH, 1013 mbar REV.: 10/2016 Phone: +41 43 311 72 00 Fax : +41 43 311 72 01 Email: [email protected] www.membrapor.ch Page 1 of 1 MEMBRAPOR AG Birkenweg 2 CH-8304 Wallisellen Switzerland The data contained in this document is for guidance only. Membrapor AG accepts no liability for any consequential losses, injury or damage resulting from the use of this document or from any omissions or errors herein. Customers should test under their own conditions, to ensure that the sensors are suitable for their own requirements.