Product Certifications 00825-0200-4140, Rev AB March 2017 Rosemount™ 2140 Level Detector Vibrating Fork Product Certifications March 2017 Product Certifications Failure to follow safe installation guidelines could result in death or serious injury. This document contains information required to safely install, connect, commission, operate and maintain, and is required for certification compliance. Use the level detector only as specified in this document and the product reference manual. Refer to the Rosemount 2140 Reference Manual for more instructions. The level detector must be installed, connected, commissioned, operated, and maintained by suitably qualified personnel only, observing national and local requirements that may apply. The weight of a level detector with a heavy flange and extended fork length may exceed 37 lb. (18 kg). A risk assessment is required before carrying, lifting, and installing the level detector. Explosions could result in death or serious injury. Please review all sections of this manual for any restrictions associated with an installation. Electrical shock could cause death or serious injury. Make sure that the level detector is not powered when removing the terminal cover and making terminal connections. If the level detector is installed in a high voltage environment and a fault condition or installation error occurs, high voltage may be present on leads and terminals. Use extreme caution when making contact with the leads and terminals. Make sure that power to the level detector is off while making connections. External surface may be hot. Care must be taken to avoid possible burns. Refer to manual This document contains information required to safely install, connect, commission, operate and maintain, and is required for certification compliance. Hot surfaces The flange and process seal may be hot at high process temperatures. Allow to cool before servicing. European directive information . . . . . . . . . . . . 3 Ordinary locations certifications . . . . . . . . . . . . 3 Canadian Registration Number . . . . . . . . . . . . 3 Hazardous locations certifications . . . . . . . . . . 4 Combinations of approvals . . . . . . . . . . . . . . . 10 2 Instructions for hazardous area installations 10 Temperature charts . . . . . . . . . . . . . . . . . . . . . 12 Intrinsic Safety Installation Drawing . . . . . . . 17 EC Declaration of Conformity . . . . . . . . . . . . . 22 March 2017 Product Certifications Product Certifications 1.0 European directive information The EC Declaration of Conformity for all applicable European directives for this product can be found on page 22 and at Emerson.com/Rosemount. 2.0 Ordinary locations certifications G5 USA Ordinary Location Certificate number: 16 CSA 70098390 Standard: UL 61010-1: 2012 The level detector has been examined and tested to determine that the design meets basic electrical, mechanical, and fire protection requirements by CSA, a nationally recognized testing laboratory (NRTL) as accredited by the Federal Occupational Safety and Health Administration (OSHA). Type 4X. G6 Canada Ordinary Location Certificate number: 16 CSA 70098390 Standards: CAN/CSA C22.2 No 61010-1-12 ANSI/ISA-12.27.01:2011 The level detector has been examined and tested to determine that the design meets basic electrical, mechanical, and fire protection requirements by CSA, a nationally recognized testing laboratory as accredited by the Standards Council of Canada (SCC). Type 4X. Single Seal. Special conditions for use (G5 and G6) 1. To be supplied from a Class 2 or Limited Energy Source in accordance with CAN/CSA C22.2 No. 61010-1-12. 3.0 Canadian Registration Number Certificate number: CRN 0F04227.2 Standards: ASME B31.3:2014 ASME B16.5:2013 The requirements of CRN are met when a Rosemount 2140 Level Detector is configured with 316/316L stainless steel (1.4401/1.4404) process-wetted parts and either NPT threaded or 2 to 8-in. ASME B16.5 flanged process connections. 3 Product Certifications March 2017 4.0 Hazardous locations certifications 4.1 USA and Canada Explosion-proof approvals E5 USA Explosion-proof and Division 2 (XP) Certificate: CSA 16CA70098990X Standards: FM Class 3600 - 2011 FM Class 3615 - 2015 UL 61010-1: 2012 Markings: Class I Groups B, C and D, T6...T2 Class I Division 2 Groups A, B, C and D, Type 4X Class I, Zone 1, AEx db IIC T6…T2 Gb Ambient and process temperatures: See “Explosion-proof approval temperatures” on page 14. Hazardous area installation instructions: See “Instructions for hazardous area installations” on page 10. E6 Canada Explosion-proof and Division 2 (XP) Certificate: CSA 16CA70098990X Standards: ANSI/ISA 12.27.01:2011 CSA Std. C22.2 No. 30 -M1986 CSA Std. C22.2 No.60079-0-15 CSA Std. C22.2. No.60079-1-16 CSA Std. C22.2 No. 61010-1-12 CSA Std. C22.2 No.94-M91 CSA Std. C22.2 No. 213-2016 Markings: Class I Groups B, C and D, T6...T2 Class I Division 2 Groups A, B, C and D, Type 4X Ex db IIC T6…T2 Gb, single seal Ambient and process temperatures: See “Explosion-proof approval temperatures” on page 14. Hazardous area installation instructions: See “Instructions for hazardous area installations” on page 10. Special conditions for use (X) (E5 and E6) 1. The user is to ensure the probe assembly is installed in such a way to prevent any damage due to impact or ignition source due to friction. 2. The enclosure may be given a non-standard paint finish which may constitute a potential electrostatic ignition risk. Care should be taken to protect it from external conditions conducive to the build-up of electrostatic charge on such surfaces. The enclosure must not be rubbed or cleaned with a dry cloth. 3. Flameproof joints are not intended for repair. 4. To be supplied from a Class 2 or Limited Energy Source in accordance with CAN/CSA C22.2 No. 61010-1-12. 4 March 2017 Product Certifications Intrinsic safety and non-incendive approvals I5 USA Intrinsic Safety (IS) and Non-Incendive (NI) Certificate: CSA 16CA70098990X Standards: FM Class 3600:2011 FM Class 3610:2015 FM Class 3611:2004 Markings: Class I Groups A, B, C and D, T5…T2 Class I, Division 2, Groups A, B, C, and D, Type 4X Class I, Zone 0, AEx ia IIC T5…T2 Ga when connected using installation drawing 71097/1387 (Figure 7 on page 17). Ambient and process temperatures: See “Intrinsic safety/intrinsically safe approval temperatures” on page 12. Hazardous area installation instructions: See “Instructions for hazardous area installations” on page 10. I6 Canada Intrinsic Safety and Non-Incendive Certificate: CSA 16CA70098990X Standards: ANSI/ISA 12.27.01:2011 CSA Std. C22.2 No. 157 -92 CSA Std. C22.2 No. 60079-0-15 CSA Std. C22.2. No. 60079-11-14 Markings: Class I Groups A, B, C and D, T5…T2 Class I, Division 2, Groups A, B, C, and D, Type 4X Ex ia IIC T5…T2 Ga, single seal when connected using installation drawing 71097/1387 (Figure 7 on page 17). Ambient and process temperatures: See “Intrinsic safety/intrinsically safe approval temperatures” on page 12. Hazardous area installation instructions: See “Instructions for hazardous area installations” on page 10. Special conditions for use (X) (I5 and I6) 1. The equipment, when fitted with the transient suppression terminal block, is not capable of withstanding the 500 volt insulation test. This must be taken into account when installing the equipment. 2. The enclosure may be made of aluminum alloy and given a protective polyurethane paint finish. However, care should be taken to protect it from impact or abrasion if located in Zone 0. 3. The enclosure may be given a non-standard paint finish which may constitute a potential electrostatic ignition risk. Care should be taken to protect it from external conditions conducive to the build-up of electrostatic charge on such surfaces. The enclosure must not be rubbed or cleaned with a dry cloth. 5 Product Certifications 4.2 European approvals ATEX flameproof approval E1 ATEX Flameproof Certificate: Dekra 16ATEX0082X Standards: EN60079-0:2012+A11:2013 EN60079-1:2014 EN60079-26:2015 Markings: II 1/2 G, Ex db IIC T6...T2 Ga/Gb Ambient and process temperatures: See “Flameproof approval temperatures” on page 14. Hazardous area installation instructions: See “Instructions for hazardous area installations” on page 10. ND ATEX Dust Certificate: Baseefa 16ATEX0137X Standards: EN60079-0:2012+A11:2013 EN60079-31:2014 Markings: II 1 D, Ex ta IIIC (T92°C…T272°C) (T500100°C…T500280°C) Da Ambient and process temperatures: See “Dust approval temperatures” on page 15. Hazardous area installation instructions: See “Instructions for hazardous area installations” on page 10. E8 Combines E1 and ND Ambient and process temperatures: See “Flameproof approval temperatures” on page 14. See “Dust approval temperatures” on page 15. Hazardous area installation instructions: See “Instructions for hazardous area installations” on page 10. ATEX intrinsic safety approval I1 ATEX Intrinsically Safe and Dust (Zone 0, 20) Certificates: Baseefa 16ATEX0136X and Baseefa 16ATEX0137X Standards: EN60079-0:2012+A11:2013 EN60079-11:2012 EN60079-26:2015 EN60079-31:2014 Markings: II 1 G, Ex ia IIC T5...T2 Ga II 1 D, Ex ta IIIC (T92°C...T272°C) (T500100°C...T500280°C) Da Input parameters: Ui = 30 V, Ii = 100 mA, Pi = 0.9 W, Ci = 0.012 F, and Li = 0 mH 6 March 2017 March 2017 Product Certifications Ambient and process temperatures: See “Intrinsic safety/intrinsically safe approval temperatures” on page 12. See “Dust approval temperatures” on page 15. Hazardous area installation instructions: See “Instructions for hazardous area installations” on page 10. (I1 includes the ND approval) I8 ATEX Intrinsic Safety (Zone 1) Certificate: Baseefa 16ATEX0136X Standards: EN60079-0:2012+A11:2013 EN60079-11:2012 EN60079-26:2015 Markings: II 1/2 G, Ex ib IIC T5...T2 Ga/Gb Input parameters: Ui = 30 V, Ii = 100 mA, Pi = 0.9 W, Ci = 0.012 F, and Li = 0 mH Ambient and process temperatures: See “Intrinsic safety/intrinsically safe approval temperatures” on page 12. Hazardous area installation instructions: See “Instructions for hazardous area installations” on page 10. Special conditions for use (X) (E1 and E8) 1. The user is to ensure the probe assembly is installed in such a way to prevent any damage due to impact or ignition source due to friction. 2. Non-standard paint options may cause risk from electrostatic discharge. Avoid installations that could cause electrostatic build-up of painted surfaces, and only clean the painted surfaces with a damp cloth. If paint is ordered through a special option code, contact the manufacturer for more information. 3. Flameproof joints are not intended for repair. Special conditions for use (X) (I1 and I8) 1. The equipment, when fitted with the transient suppression terminal block, is not capable of withstanding the 500 volt insulation test. This must be taken into account when installing the equipment. 2. The enclosure may be made of aluminum alloy and given a protective polyurethane paint finish. However, care should be taken to protect it from impact or abrasion if located in Zone 0. 3. The enclosure may be given a non-standard paint finish which may constitute a potential electrostatic ignition risk. Care should be taken to protect it from external conditions conducive to the build-up of electrostatic charge on such surfaces. The enclosure must not be rubbed or cleaned with a dry cloth. Special conditions for use (X) (ND, E8, and I1) 1. Cable entries must maintain the ingress protection rating of the enclosure to at least IP66. 2. Unused cable entries must be filled with suitable blanking plugs which maintain the ingress protection of the enclosure to at least IP66. 7 Product Certifications March 2017 3. Cable entries and blanking plugs must be suitable for the ambient temperature of the equipment and be capable of withstanding a 7J impact test. 4. The enclosure may be given a non-standard paint finish which may constitute a potential electrostatic ignition risk. Care should be taken to protect it from external conditions conducive to the build-up of electrostatic charge on such surfaces. The enclosure must not be rubbed or cleaned with a dry cloth. 4.3 International approvals International Electrotechnical Commission (IEC) flameproof approval E7 IECEx Flameproof and Dust Certificates: IECEx DEK 16.0040X and IECEx BAS 16.0106X Standards: IEC60079-0:2011 IEC60079-1:2014 IEC60079-26:2014 IEC60079-31:2013 Markings: Ex db IIC T6...T2 Ga/Gb Ex ta IIIC (T92°C…T272°C) (T500100°C…T500280°C) Da Ambient and process temperatures: See “Intrinsic safety/intrinsically safe approval temperatures” on page 12. See “Dust approval temperatures” on page 15. Hazardous area installation instructions: See “Instructions for hazardous area installations” on page 10. (E7 also includes the NK approval) International Electrotechnical Commission (IEC) intrinsically safe approval I7 IECEx Intrinsically Safe Certificate: IECEx BAS 16.0105X Standards: IEC60079-0:2011 IEC60079-11:2011 Markings: Ex ia IIC T5...T2 Ga Input parameters: Ui = 30 V, Ii = 100 mA, Pi = 0.9 W, Ci = 0.012 F, and Li = 0 mH Ambient and process temperatures: See “Intrinsic safety/intrinsically safe approval temperatures” on page 12. Hazardous area installation instructions: See “Instructions for hazardous area installations” on page 10. 8 March 2017 Product Certifications International Electrotechnical Commission (IEC) dust approval NK IECEx Dust Certificate: IECEx BAS 16.0106X Standards: IEC60079-0:2011 IEC60079-31:2013 Markings: Ex ta IIIC (T92°C…T272°C) (T500100°C…T500280°C) Da Ambient and process temperatures: See “Dust approval temperatures” on page 15. Hazardous area installation instructions: See “Instructions for hazardous area installations” on page 10. Special conditions for use (X) (E7) 1. The user is to ensure the probe assembly is installed in such a way to prevent any damage due to impact or ignition source due to friction. 2. Non-standard paint options may cause risk from electrostatic discharge. Avoid installations that could cause electrostatic build-up of painted surfaces, and only clean the painted surfaces with a damp cloth. If paint is ordered through a special option code, contact the manufacturer for more information. 3. Flameproof joints are not intended for repair. Special conditions for use (X) (I7) 1. The equipment, when fitted with the transient suppression terminal block, is not capable of withstanding the 500 volt insulation test. This must be taken into account when installing the equipment. 2. The enclosure may be made of aluminum alloy and given a protective polyurethane paint finish. However, care should be taken to protect it from impact or abrasion if located in Zone 0. 3. The enclosure may be given a non-standard paint finish which may constitute a potential electrostatic ignition risk. Care should be taken to protect it from external conditions conducive to the build-up of electrostatic charge on such surfaces. The enclosure must not be rubbed or cleaned with a dry cloth. Special conditions for use (X) (NK, E8) 1. Cable entries must maintain the ingress protection rating of the enclosure to at least IP66. 2. Unused cable entries must be filled with suitable blanking plugs which maintain the ingress protection of the enclosure to at least IP66. 3. Cable entries and blanking plugs must be suitable for the ambient temperature of the equipment and be capable of withstanding a 7J impact test. 4. The enclosure may be given a non-standard paint finish which may constitute a potential electrostatic ignition risk. Care should be taken to protect it from external conditions conducive to the build-up of electrostatic charge on such surfaces. The enclosure must not be rubbed or cleaned with a dry cloth. 9 Product Certifications March 2017 5.0 Combinations of approvals K1 K5 KB KZ Combines I1 and E1 Combines I5 and E5 Combines I5, I6, E5, and E6 Combines G5 and G6 6.0 Instructions for hazardous area installations 6.1 General 1. Installation of this equipment shall be carried out by suitably trained personnel, in accordance with the applicable code of practice. 2. Inspection and maintenance of this equipment shall be carried out by suitably trained personnel, in accordance with the applicable code of practice. 3. The user should not repair this equipment 4. The certification of this equipment relies upon the following materials used in its construction: Housing and cover: Aluminum alloy ASTM B85 A360.0 or stainless steel 316C12 Probe (partition wall): Stainless steel 316/316L, or UNS N10276, or UNS N10002, or UNS N30002 Seals: Silicone. 5. If the equipment is likely to come into contact with aggressive substances, it is the responsibility of the user to take suitable precautions that prevent it from being adversely affected, thus ensuring that the type of protection is not compromised. Aggressive substances e.g. acidic liquids or gases that may attack metals or solvents that may affect polymeric materials. Suitable precautions e.g. regular checks as part of routine inspections or establishing from the material's data sheet that it is resistant to specific chemicals. 6. It is the responsibility of the user to ensure: a. The voltage and current limits for this equipment are not exceeded. b. The protective earth terminal is connected to an external protective earthing system. c. That the joint requirements between the probe and the vessel tank are compatible with the process media. d. That the joint tightness is correct for the joint material used. e. Safe working practices for the media and process concerned are followed during the installation and maintenance of the equipment. 7. The probe fork is subjected to small vibration stresses as part of its normal function. As this provides a partition wall, it is recommended that the fork should be inspected every two years for signs of defects. 8. Technical data 10 March 2017 Product Certifications a. Pressure must not exceed the rating of the coupling/flange fitted. b. For material details and pressure ratings, refer to the Rosemount 2140 Reference Manual. c. Year of manufacture is marked on the product label. 6.2 ATEX specific instructions 1. The equipment has not been assessed as a safety related device (as referred to by directive 2014/34/EU Annex II, clause 1.5). 6.3 Intrinsic safety specific instructions 1. The equipment may be used with flammable gases and vapors with apparatus groups IIA, IIB and IIC, and with temperature classes T1, T2, T3, T4 and T5. The temperature class of the installation will be determined from the higher of the process or ambient temperature. 2. The equipment with Product Certifications code “I8” is suitable for installation across the boundary between an area that specifically requires Equipment Protection Level Ga (Zone 0) and an area that specifically requires Equipment Protection Level Gb (Zone 1). The probe forks (and extension tube) are only to be installed in Zone 0. 3. When fitted with the Transient Protection Terminal Block (option code T1), the unit does not meet the requirements of clause 6.3.13 (Isolation of circuits from earth or frame) in EN 60079-11:2012 (IEC 60079-11:2011). 4. Technical data a. Input parameters: Ui: 30 V, Ii: 100 mA, Pi: 0.9 W, Ci: 0.012 F, Li: 0 6.4 Flameproof and explosion-proof specific instructions 1. The equipment may be used with flammable gases and vapors with apparatus groups IIA, IIB and IIC, and with temperature classes T1, T2, T3, T4, T5 and T6. The temperature class of the installation will be determined from the higher of the process or ambient temperature. 2. The equipment is suitable for installation across the boundary between an area that specifically requires Equipment Protection Level Ga (Zone 0) and an area that specifically requires Equipment Protection Level Gb (Zone 1). The probe forks (and extension tube) are only to be installed in Zone 0. 3. Repair or modification of flame-paths is not permitted. 4. It is the responsibility of the user to ensure: a. The housing anti-rotation grub screw is screwed in fully. b. The housing cover locking screws are unscrewed tightly against the covers. c. That only suitably certified cable entry devices will be utilized when connecting this equipment. The cable entry temperature may exceed 70 °C. d. That suitable temperature rated cable is used. For connections in an ambient in excess of 60 °C, use cable rated to at least 90 °C. e. That any unused cable entries are sealed with suitably certified stopping plugs. 5. Only screws and fittings provided by the manufacturer can be attached to the housing. 6. Technical data a. Electrical: Vmax = 42.4 Vdc, Imax =23.5 mA. 11 Product Certifications March 2017 6.5 Dust (protection by enclosure) specific instructions 1. The equipment may be used in a hazardous area with explosive dusts with apparatus groups IIIC, IIIB, and IIIA. The maximum surface temperature of the installation will be determined from the higher of the process or ambient temperature. 2. It is the responsibility of the user to ensure: a. The housing anti-rotation grub screw is screwed in fully. b. The housing cover locking screws are unscrewed tightly against the covers. c. That only suitably certified cable entry devices will be utilized when connecting this equipment. The cable entry temperature may exceed 70 °C. d. That suitable temperature rated cable is used. For connections in an ambient in excess of 60 °C, use cable rated to at least 90 °C. 7.0 Temperature charts The graphs in Figure 1 on page 13 through Figure 6 on page 16 show: the Maximum Ambient Temperature (Ta) permitted for a particular Process Temperature (Tp). the permitted Ambient (Ta) and Process (Tp) temperature ranges for a particular gas Temperature Class. 7.1 Intrinsic safety/intrinsically safe approval temperatures 2140****M* T5: ambient air temperature (Ta) = -60 °C to +40 °C process temperature (Tp) = -40 °C to +95 °C T4…T1: see Figure 1 on page 13. 2140****E* T5: ambient air temperature (Ta) = -60 °C to +40 °C process temperature (Tp) = -70 °C to +95 °C T4…T1: see Figure 2 on page 13. 12 Product Certifications March 2017 Figure 1. 2140****M* Temperature De-rating (Intrinsically Safe) 70 60.7 T4...T1 53 Ambient Temperature (°C) 40 T3...T1 T5...T1 0 -60 -40 0 70 130 95 180 Process Temperature (°C) Figure 2. 2140****E* Temperature De-rating (Intrinsically Safe) 70 66.8 63.4 60 T4...T1 Ambient Temperature (°C) 40 T2...T1 T3...T1 T5...T1 0 -60 -70 0 70 95 130 195 260 Process Temperature (°C) 13 March 2017 Product Certifications 7.2 Flameproof approval temperatures 2140****M* T6: ambient air temperature (Ta) = -50 °C to +65 °C process temperature (Tp) = -40 °C to +80 °C T5…T1: see Figure 3 on page 14 (-## = -50°C) 2140****E* T6: ambient air temperature (Ta) = -50 °C to +65 °C process temperature (Tp) = -70 °C to +80 °C T5…T1: see Figure 4 on page 15 (-## = -50 °C) 7.3 Explosion-proof approval temperatures 2140****M* T6: ambient air temperature (Ta) = -40 °C to +65 °C process temperature (Tp) = -40 °C to +80 °C T5…T1: see Figure 3 on page 14 (-## = -40 °C) 2140****E* T6: ambient air temperature (Ta) = -40 °C to +65 °C process temperature (Tp) = -70 °C to +80 °C T5…T1: see Figure 4 on page 15 (-## = -40 °C) Figure 3. 2140****M* Temperature De-rating (Flameproof/Explosion-proof) Ambient Temperature (°C) 80 77 70 65 60 T5...T1 T6...T1 0 -## -40 0 80 95 Process Temperature (°C) 14 T3...T1 T4...T1 130 180 Product Certifications March 2017 Figure 4. 2140****E* Temperature De-rating (Flameproof/Explosion-proof) 80 79 77 73.5 T5...T1 Ambient Temperature (°C) 65 T6...T1 T4...T1 70 T2...T1 T3...T1 0 -## -70 0 80 95 130 195 260 Process Temperature (°C) 7.4 Dust approval temperatures 2140****M* Minimum ambient air temperature (Ta) = -20°C Maximum ambient air temperature (Ta) = See Figure 5 Maximum Surface Temperature (T**°C) = See Figure 5 Maximum Surface Temperature under 500 mm layer (T500***°C) = See Figure 5 2140****E* Minimum ambient air temperature (Ta) = -20°C Maximum ambient air temperature (Ta) = See Figure 6 Maximum Surface Temperature (T**°C) = See Figure 6 Maximum Surface Temperature under 500 mm layer (T500***°C) = See Figure 6 15 March 2017 Product Certifications Figure 5. 2140****M* Maximum Surface Temperature 80 Surface Temperature (°C) Ambient 60 T500***°C 100 92 T***°C 0 -40 80 0 Maximum Ambient Temperature (°C) 200 192 180 Process Temperature (°C) Figure 6. 2140****E* Maximum Surface Temperature 280 272 80 70 T500***°C T***°C 100 92 0 -70 0 80 Process Temperature (°C) 16 260 Ambient Temperature (°C) Surface Temperature (°C) Ambient Product Certifications March 2017 8.0 Intrinsic Safety Installation Drawing Figure 7. USA and Canada Installation drawing 71097/1387 (Page 1) APPROVAL TITLE DOCUMENT NUMBER: - APPR.DRG. I.S. & NONINCENDIVE CONTROL DRAWING FOR ROSEMOUNT 2140 71097/1387 Page 1 of 5 AB 24/01/17 MBY-05601 GP DRAWN REVISION DATE ECO No. NAME APPROVED JPA 19/10/16 SEE ECO CERTIFIED PRODUCT: ALTERATIONS TO THIS DOCUMENT MUST BE APPROVED BEFORE IMPLEMENTATION. GENERAL NOTES: 1. ASSOCIATED APPARATUS MANUFACTURER'S INSTALLATION DRAWING MUST BE FOLLOWED WHEN INSTALLING THIS EQUIPMENT. 2. CONTROL EQUIPMENT CONNECTED TO BARRIER MUST NOT USE OR GENERATE MORE THAN 250 Vrms or Vdc, 3. RESISTANCE BETWEEN INTRINSICALLY SAFE GROUND AND EARTH GROUND MUST BE LESS THAN 1 OHM, 4. INSTALLATION SHOULD BE IN ACCORDANCE WITH APPLICABLE LAWS/REGULATIONS AND CODE OR PRACTICE. I.E. FOR CANADA, THE CANADIAN ELECTRICAL CODE (CSA C22.1); FOR AMERICA, THE NATIONAL ELECTRICAL CODE (ANSI/NFPA 70) AND ANSI/ISA-RP12.6 “INSTALLATION OF INTRINSICALLY SAFE SYSTEMS FOR HAZARDOUS (CLASSIFIED) LOCATIONS”. 5. THE ASSOCIATED APPARATUS, BARRIER OR ISOLATOR MUST BE APPROVED. FOR CANADA, TO CANADIAN STANDARDS BY AN NRTL ACCREDITED BY THE STANDARDS COUNCIL OF CANADA (SCC). FOR AMERICA, TO AMERICAN STANDARDS BY AN NRTL ACCREDITED BY THE OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA). 6. WARNING -SUBSTITUTION OF COMPONENTS MAY IMPAIR INTRINSIC AND NON-INCENDIVE SAFETY, AVERTISSEMENT: LA SUBSTITUTION DE COMPOSANTS PEUT COMPROMETTRE LA SÉCURITÉ INTRINSÈQUE ET LA SÉCURITÉ NON INCENDIAIRIES 7. ASSOCIATED APPARATUS MUST MEET THE FOLLOWING PARAMETERS: Uo or Voc or Vt LESS THAN or EQUAL TO Ui (Vmax) Io or Isc or It LESS THAN or EQUAL TO Ii (Imax) Po or Pmax LESS THAN or EQUAL TO Pi (Pmax) Ca IS GREATER THAN or EQUAL THE SUM OF ALL Ci's PLUS Ccable La IS GREATER THAN or EQUAL THE SUM OF ALL Li's PLUS Lcable 8. THE ASSOCIATED APPARATUS MUST BE A RESISTIVELY LIMITED SINGLE OR MULTIPLE CHANNEL APPROVED BARRIER HAVING PARAMETERS LESS THAN THOSE QUOTED, AND FOR WHICH THE OUTPUT AND THE COMBINATIONS OF OUTPUTS IS NON-IGNITION CAPABLE FOR THE CLASS, DIVISION AND GROUP OF USE, 9. FIELD WIRING SHOULD BE RATED TO 70°C MINIMUM, © ROSEMOUNT MEASUREMENT LIMITED 2017 THE REPRODUCTION, DISTRIBUTION, & UTILISATION OF THIS DOCUMENT AS WELL AS THE COMMUNICATION OF ITS CONTENTS TO OTHERS WITHOUT EXPRESS AUTHORISATION IS PROHIBITED. OFFENDERS WILL BE HELD LIABLE FOR PAYMENT OF DAMAGES. ALL RIGHTS RESERVED IN THE EVENT OF PATENT, UTILITY MODEL OR DESIGN. L2073 Iss. AA 17 March 2017 Product Certifications Figure 8. USA and Canada Installation drawing 71097/1387 (Page 2) APPROVAL TITLE APPR.DRG. I.S. & NONINCENDIVE CONTROL DRAWING FOR ROSEMOUNT 2140 DOCUMENT NUMBER: - 71097/1387 Page 2 of 5 AB 24/01/17 MBY-05601 GP DRAWN REVISION DATE ECO No. NAME APPROVED JPA 19/10/16 SEE ECO CERTIFIED PRODUCT: ALTERATIONS TO THIS DOCUMENT MUST BE APPROVED BEFORE IMPLEMENTATION. DIV 1 INSTALLATION OPTIONS THE ROSEMOUNT TRANSMITTER IS APPROVED AS INTRINSICALLY SAFE WHEN USED IN CIRCUIT WITH APPROVED BARRIERS WHICH MEET THE ENTITY PARAMETERS LISTED IN THE CLASS I. DIVISION 1 GROUPS INDICATED. ADDITIONALLY, THE ROSEMOUNT 751 FIELD SIGNAL INDICATOR IS APPROVED AS INTRINSICALLY SAFE WHEN CONNECTED IN CIRCUIT WITH ROSEMOUNT TRANSMITTERS AND APPROVED BARRIERS WHICH MEET THE ENTITY PARAMETERS LISTED FOR CLASS I, DIVISION 1, GROUPS INDICATED. TO ASSURE AN INTRINSICALLY SAFE SYSTEM. THE TRANSMITTER AND BARRIER MUST BE WIRED IN ACCORDANCE WITH THE BARRIER MANUFACTURER'S FIELD WIRING INSTRUCTIONS AND THE APPLICABLE CIRCUIT DIAGRAM. © ROSEMOUNT MEASUREMENT LIMITED 2017 THE REPRODUCTION, DISTRIBUTION, & UTILISATION OF THIS DOCUMENT AS WELL AS THE COMMUNICATION OF ITS CONTENTS TO OTHERS WITHOUT EXPRESS AUTHORISATION IS PROHIBITED. OFFENDERS WILL BE HELD LIABLE FOR PAYMENT OF DAMAGES. ALL RIGHTS RESERVED IN THE EVENT OF PATENT, UTILITY MODEL OR DESIGN. 18 L2073 Iss. AA Product Certifications March 2017 Figure 9. USA and Canada Installation drawing 71097/1387 (Page 3) APPROVAL APPR.DRG. I.S. & NONINCENDIVE CONTROL DRAWING FOR ROSEMOUNT 2140 TITLE DOCUMENT NUMBER: - 71097/1387 Page 3 of 5 AB 24/01/17 MBY-05601 GP DRAWN REVISION DATE ECO No. NAME APPROVED JPA 19/10/16 SEE ECO CERTIFIED PRODUCT: ALTERATIONS TO THIS DOCUMENT MUST BE APPROVED BEFORE IMPLEMENTATION. ENTITY CONCEPT APPROVALS THE ENTITY CONCEPT ALLOWS INTERCONNECTION OF INTRINSICALLY SAFE APPARATUS TO ASSOCIATED APPARATUS NOT SPECIFICALLY EXAMINED IN COMBINATION AS A SYSTEM. THE APPROVED VALUES OF MAX. OPEN CIRCUIT VOLTAGE (Voc OR Vt) AND MAX. SHORT CIRCUIT CURRENT (Isc OR It) AND MAX,POWER (Voc X Isc/4) OR (Vt X It/4), FOR THE ASSOCIATED APPARATUS MUST BE LESS THAN OR EQUAL TO THE MAXIMUM SAFE INPUT VOLTAGE (Vmax), MAXIMUM SAFE INPUT CURRENT (Imax), AND MAXIMUM SAFE INPUT POWER (Pmax) OF THE INTRINSICALLY SAFE APPARATUS. IN ADDITION, THE APPROVED MAX. ALLOWABLE CONNECTED CAPACITANCE (Ca) OF THE ASSOCIATED APPARATUS MUST BE GREATER THAN THE SUM OF THE INTERCONNECTING CABLE CAPACITANCE AND THE UNPROTECTED INTERNAL CAPACITANCE (Ci) OF THE INTRINSICALLY SAFE APPARATUS, AND THE APPROVED MAX. ALLOWABLE CONNECTED INDUCTANCE (La) OF THE ASSOCIATED APPARATUS MUST BE GREATER THAN THE SUM OF THE INTERCONNECTING CABLE INDUCTANCE AND THE UNPROTECTED INTERNAL INDUCTANCE (Li) OF THE INTRINSICALLY SAFE APPARATUS, NOTE: ENTITY PARAMETERS LISTED APPLY ONLY TO ASSOCIATED APPARATUS WITH LINEAR OUTPUT. CLASS I, DIV 1, GROUPS A AND B Vmax = 30V Vt OR Voc IS LESS THAN OR EQUAL TO 30V Imax = 100mA It OR Isc IS LESS THAN OR EQUAL TO 100mA Pmax = 0.9 WATT ( Ci = 0.012µF Ca IS GREATER THAN 0.012µF Li La IS GREATER THAN 0mH = 0mH ) OR ( ) IS LESS THAN OR EQUAL TO 0.9 WATT CLASS I, DIV 1, GROUPS C AND D Vmax = 30V Vt OR Voc IS LESS THAN OR EQUAL TO 30V Imax = 100mA It OR Isc IS LESS THAN OR EQUAL TO 100mA Pmax = 0.9 WATT ( Ci = 0.012µF Ca IS GREATER THAN 0.012µF Li La IS GREATER THAN 0mH = 0mH ) OR ( ) IS LESS THAN OR EQUAL TO 0.9 WATT DIV 2 INSTALLATION OPTIONS © ROSEMOUNT MEASUREMENT LIMITED 2017 THE REPRODUCTION, DISTRIBUTION, & UTILISATION OF THIS DOCUMENT AS WELL AS THE COMMUNICATION OF ITS CONTENTS TO OTHERS WITHOUT EXPRESS AUTHORISATION IS PROHIBITED. OFFENDERS WILL BE HELD LIABLE FOR PAYMENT OF DAMAGES. ALL RIGHTS RESERVED IN THE EVENT OF PATENT, UTILITY MODEL OR DESIGN. L2073 Iss. AA 19 March 2017 Product Certifications Figure 10. USA and Canada Installation drawing 71097/1387 (Page 4) APPROVAL TITLE DOCUMENT NUMBER: - APPR.DRG. I.S. & NONINCENDIVE CONTROL DRAWING FOR ROSEMOUNT 2140 71097/1387 Page 4 of 5 AB 24/01/17 MBY-05601 GP DRAWN REVISION DATE ECO No. NAME APPROVED JPA 19/10/16 SEE ECO CERTIFIED PRODUCT: ALTERATIONS TO THIS DOCUMENT MUST BE APPROVED BEFORE IMPLEMENTATION. CLASS I, DIV.2 HAZARDOUS (CLASSIFIED) LOCATION UNCLASSIFIED LOCATION UNSPECIFIED EQUIPMENT [3] MECHANICALLY PROTECTED WIRE PER APPLICABLE ELECTRICAL CODE APPROVED ASSOCIATED NONINCENDIVE APPARATUS [1] NOTES: [1] ASSOCIATED NON-INCENDIVE APPARATUS PARAMETERS SHALL BE THE SAME AS THOSE SHOWN ON PAGE 3 [2] MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE ELECTRIC CODE FOR WIRING IN DIVISION 2 HAZARDOUS (CLASSIFIED) LOCATIONS. [3] SUPPLIED BY A CLASS 2 OR LIMITED ENERGY SOURCE IN ACCORDANCE WITH CAN/CSA-C22.2 No. 61010-1-12 © ROSEMOUNT MEASUREMENT LIMITED 2017 THE REPRODUCTION, DISTRIBUTION, & UTILISATION OF THIS DOCUMENT AS WELL AS THE COMMUNICATION OF ITS CONTENTS TO OTHERS WITHOUT EXPRESS AUTHORISATION IS PROHIBITED. OFFENDERS WILL BE HELD LIABLE FOR PAYMENT OF DAMAGES. ALL RIGHTS RESERVED IN THE EVENT OF PATENT, UTILITY MODEL OR DESIGN. 20 L2073 Iss. AA Product Certifications March 2017 Figure 11. USA and Canada Installation drawing 71097/1387 (Page 5) APPROVAL TITLE DOCUMENT NUMBER: - APPR.DRG. I.S. & NONINCENDIVE CONTROL DRAWING FOR ROSEMOUNT 2140 71097/1387 Page 5 of 5 AB 24/01/17 MBY-05601 GP DRAWN REVISION DATE ECO No. NAME APPROVED JPA 19/10/16 SEE ECO CERTIFIED PRODUCT: ALTERATIONS TO THIS DOCUMENT MUST BE APPROVED BEFORE IMPLEMENTATION. NONINCENDIVE FIELD CIRCUIT CLASS I. DIV. 2 LOCATIONS NON-HAZARDOUS LOCATION DIVISION 2 HAZARDOUS (CLASSIFIED) LOCATION APPROVED NONINCENDIVE SUPPLY Vmax1 Ci1 Li1 Imax1 Vmax2 Ci2 Li2 Imax2 D D Vmax3 Ci3 Li3 Imax3 VmaxN CiN LiN ImaxN D D WIRING PER APPLICABLE ELECTRICAL CODE MECANICALLY PROTECTED WIRE PER APPLICABLE ELECTRICAL CODE IN NORMAL OPERATION DEVICES CONTROL THROUGH-CURRENT PARAMETERS DEVICE Voc = MInImum of (Vmax1, Vmax2, ...., VmaxN) Imax1 >= Iq1 + Isignal1 Imax2 >= Iq2 + Isignal2 , , , ImaxN >= IqN + IsignalN Ca <= Ci1 + Ci2 + ... + CiN + Ccable La <= Li1 + Li2 + ... + LiN + Lcable Imax for an Individual device = Iq + Isignal Iq = Quiescent current through devlce (Maximum quiescent current for the device) Isignal = Signaling current through device (Protocol may limit signaling to one device at a time) Vmax MaxImum normal operatIng current Ca La 4-20mA/HART 42.4V 23.5mA 0.012µF 0µH ROSEMOUNT 2140 TRANSMITTERS ARE CURRENT CONTROLLERS ON INDIVIDUAL PARALLEL BRANCHES WITH RESPECT TO THE POWER SUPPLY. IN NONINCENDIVE INSTALLATIONS THE Imax FOR EACH TRANSMITTER IS NOT RELATED TO THE MAXIMUM CURRENT OF THE POWER SUPPLY (Isc) lN THE SAME MANNER AS FOR TRANSMITTER INSTALLED PER I.S. REQUIREMENTS. BECAUSE NONINCENDIVE REQUIREMENTS INCLUDE ONLY NORMAL OPERATING CONDITIONS. IT SHALL BE SUPPLIED BY A CLASS 2 OR LIMITED ENERGY SOURCE IN ACCORDANCE WITH CAN/CSA22.2 No. 61010-1-12 OperatIng Imax = Iq1 + Iq2 + ... + IqN + Isignal max Isignal max = Max. of (lsignal1, Isignal2 ..... IsignalN) © ROSEMOUNT MEASUREMENT LIMITED 2017 THE REPRODUCTION, DISTRIBUTION, & UTILISATION OF THIS DOCUMENT AS WELL AS THE COMMUNICATION OF ITS CONTENTS TO OTHERS WITHOUT EXPRESS AUTHORISATION IS PROHIBITED. OFFENDERS WILL BE HELD LIABLE FOR PAYMENT OF DAMAGES. ALL RIGHTS RESERVED IN THE EVENT OF PATENT, UTILITY MODEL OR DESIGN. L2073 Iss. AA 21 Product Certifications 9.0 EC Declaration of Conformity Figure 12. Rosemount 2140 Declaration of Conformity (Page 1) 22 March 2017 March 2017 Product Certifications Figure 13. Rosemount 2140 Declaration of Conformity (Page 2) 23 Product Certifications Figure 14. Rosemount 2140 Declaration of Conformity (Page 3) 24 March 2017 Product Certifications March 2017 ਜ਼ᴹChina RoHS㇑᧗⢙䍘䎵䗷ᴰབྷ⎃ᓖ䲀٬Ⲵ䜘Ԧරਧࡇ㺘Rosemount 2140 List of Rosemount 2140 Parts with China RoHS Concentration above MCVs ᴹᇣ⢙䍘 䍘/ Hazardous Substances 䫵 Lead (Pb) ⊎ Mercury (Hg) 䭹 Cadmium (Cd) ޝԧ䬜 䬜 Hexavalent Chromium (Cr +6) ཊⓤ㚄 㚄㤟 Polybrominated biphenyls (PBB) ཊⓤ㚄 㚄㤟䟊 Polybrominated diphenyl ethers (PBDE) ⭥ᆀ㓴Ԧ Electronics Assembly X O O O O O ༣փ㓴Ԧ Housing Assembly O O O X O O Րᝏಘ㓴Ԧ Sensor Assembly X O O O O X 䜘Ԧ〠 Part Name ᵜ㺘Ṭ㌫ᦞSJ/T11364Ⲵ㿴ᇊ㘼ࡦ This table is proposed in accordance with the provision of SJ/T11364. O: Ѫ䈕䜘ԦⲴᡰᴹ൷䍘ᶀᯉѝ䈕ᴹᇣ⢙䍘Ⲵਜ਼䟿൷վҾGB/T 26572ᡰ㿴ᇊⲴ䲀䟿㾱≲ O: Indicate that said hazardous substance in all of the homogeneous materials for this part is below the limit requirement of GB/T 26572. X: Ѫ൘䈕䜘Ԧᡰ֯⭘Ⲵᡰᴹ൷䍘ᶀᯉ䟼ˈ㠣ቁᴹа㊫൷䍘ᶀᯉѝ䈕ᴹᇣ⢙䍘Ⲵਜ਼䟿儈ҾGB/T 26572ᡰ㿴ᇊⲴ䲀䟿㾱≲ X: Indicate that said hazardous substance contained in at least one of the homogeneous materials used for this part is above the limit requirement of GB/T 26572. 25 Product Certifications 00825-0200-4140, Rev AB March 2017 Global Headquarters Emerson Automation Solutions 6021 Innovation Blvd. Shakopee, MN 55379, USA +1 800 999 9307 or +1 952 906 8888 +1 952 949 7001 [email protected] North America Regional Office Emerson Automation Solutions 8200 Market Blvd. Chanhassen, MN 55317, USA +1 800 999 9307 or +1 952 906 8888 +1 952 949 7001 [email protected] Latin America Regional Office Emerson Automation Solutions 1300 Concord Terrace, Suite 400 Sunrise, FL 33323, USA +1 954 846 5030 +1 954 846 5121 [email protected] Linkedin.com/company/Emerson-Automation-Solutions Europe Regional Office Emerson Automation Solutions Europe GmbH Neuhofstrasse 19a P.O. Box 1046 CH 6340 Baar Switzerland +41 (0) 41 768 6111 +41 (0) 41 768 6300 [email protected] Twitter.com/Rosemount_News Facebook.com/Rosemount Asia Pacific Regional Office Emerson Automation Solutions Asia Pacific Pte Ltd 1 Pandan Crescent Singapore 128461 +65 6777 8211 +65 6777 0947 [email protected] Youtube.com/user/RosemountMeasurement Google.com/+RosemountMeasurement Middle East and Africa Regional Office Emerson Automation Solutions Emerson FZE P.O. Box 17033 Jebel Ali Free Zone - South 2 Dubai, United Arab Emirates +971 4 8118100 +971 4 8865465 [email protected] Standard Terms and Conditions of Sale can be found at www.Emerson.com/en-us/Terms-of-Use The Emerson logo is a trademark and service mark of Emerson Electric Co. Rosemount, and Rosemount logotype are trademarks of Emerson. HART is a registered trade mark of FieldComm Group. All other marks are the property of their respective owners. © 2017 Emerson. All rights reserved.