Download Decibel study guide

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Earplug wikipedia , lookup

Mondegreen wikipedia , lookup

Auditory system wikipedia , lookup

Hearing loss wikipedia , lookup

Sound wikipedia , lookup

Sound localization wikipedia , lookup

Sound from ultrasound wikipedia , lookup

Noise-induced hearing loss wikipedia , lookup

Audiology and hearing health professionals in developed and developing countries wikipedia , lookup

Sensorineural hearing loss wikipedia , lookup

Transcript
Decibel Study Questions
1. What reference is used for the dBIL scale?
2. What reference is used for the dBSPL scale?
3. What reference is used for the dBHL scale?
4. What reference is used for the dBSL scale?
5. A listener barely detects a 125 Hz pure tone at 55 dBSPL. Does this listener have a hearing loss
at 125 Hz, and if so, what is the size of the hearing loss?
6. A listener barely detects a 1,000 Hz pure tone at 55 dBSPL. Does this listener have a hearing
loss at 1,000 Hz, and if so, what is the size of the hearing loss?
7. A listener barely detects a 125 Hz pure tone at 55 dBHL. Does this listener have a hearing loss at
125 Hz, and if so, what is the size of the hearing loss?
8. A listener barely detects a 1,000 Hz pure tone at 55 dBHL. Does this listener have a hearing loss
at 1,000 Hz, and if so, what is the size of the hearing loss?
9. 60 dBSPL at 1,000 Hz means ______________________ more intense than
_______________________________.
10. 60 dBIL at 1,000 Hz means ______________________ more intense than
_______________________________.
11. 60 dBHL at 1,000 Hz means ______________________ more intense than
_______________________________.
12. The reference that is used for the dBSPL scale is:
a. a number
b. a sentence
13. If the answer to the question above is a number, give the number; if it’s a sentence, give the
sentence.
14. The reference that is used for the dBHL scale is:
a. a number
b. a sentence
2
15. If the answer to the question above is a number, give the number; if it’s a sentence, give the
sentence.
16. A specific individual has a 70 dB hearing loss in the left ear at 1,000 Hz. A 90 dBHL, 1,000 Hz
tone that is presented to this listener’s left ear would measure ______ dBSL.
17. A sound measures 42 dBIL. On the dBSPL scale, that same sound will measure:
a. 84 dBSPL because with the dBSPL formula we are now are multiplying the ratio by 20 instead
of 10.
b. 42 dBSPL because the two versions of the formula are equivalent
18. A sound measures 60 dBIL. (a) The measured intensity (IM) must therefore be _________ times
greater than the reference intensity (IR). (b) What would the pressure ratio (EM/ER) be for this
same sound? (c) Do the arithmetic to show what this sound would measure in dBSPL.
19. A sound measures 40 dBIL. (a) The measured intensity (IM) must therefore be _________ times
greater than the reference intensity (IR). (b) What would the pressure ratio (EM/ER) be for this
same sound? (c) Do the arithmetic to show what this sound would measure in dBSPL.
20. On the graph below, put a mark at: (a) 3,000 Hz, 20 dBSPL, and (b) 3,000 Hz, 20 dBHL (the
grid lines on the y axis are spaced at 2 dB intervals).
Frequency
in Hz
125
250
500
750
1000
1500
2000
3000
4000
6000
8000
Threshold
in dB SPL
45.0
25.5
11.5
8.0
7.0
6.5
9.0
10.0
9.5
15.5
13.0
21. Show the algebraic steps that are involved in deriving the dBSPL formula from the dBIL formula.
3
Answers to Decibel Study Questions
1. 10-12 watts/m2
2. 0.0002 dynes/cm2 (or 20 micro Pascals)
3. The threshold of audibility for an average, normal-hearing listener at a particular signal
frequency.
4. The threshold of audibility for a particular listener in a particular ear at a particular signal
frequency.
5. Consulting the attached figure and table showing the audibility curve for average, normalhearing listeners, we find that the threshold of audibility at 125 Hz is 45 dBSPL. A listener who
barely detected a 125 Hz tone at 55 dBSPL would therefore have hearing loss of 55-45=10 dB;
that is, the hearing sensitivity of this listener would be 10 dB worse than normal.
6. Consulting the attached figure and table showing the audibility curve for average, normalhearing listeners, we find that the threshold of audibility at 1,000 Hz is 7 dBSPL. A listener who
barely detected a 1,000 Hz tone at 55 dBSPL would therefore have a hearing loss of 55-7=48
dB; that is, the hearing sensitivity of this listener would be 48 dB worse than normal.
7. The reference for dBHL is the audibility threshold, so this listener would have a 55 dB hearing
loss at 125 Hz. There is no need to consult the table.
8. The reference for dBHL is the audibility threshold, so this listener would have a 55 dB hearing
loss at 1,000 Hz. There is no need to consult the table.
9. 6 factors of 10 (i.e., 1,000,000 times) more intense than 0.0002 dynes/cm2 (or 20 micro Pascals)
10. 6 factors of 10 (i.e., 1,000,000 times) more intense than 10-12 watts/m2
11. 6 factors of 10 (i.e., 1,000,000 times) more intense than a 1,000 tone that is barely audible to an
average, normal-hearing listener.
12. a number
13. 0.0002 dynes/cm2 (or, equivalently, 20 micro Pascals)
14. a sentence
15. The threshold of audibility for an average, normal-hearing listener at a particular signal
frequency.
16. 20 dBSL. The reference for the dBSL (SL=sensation level) is the threshold of audibility for a
specific listener. So, what we want to know here very simply is where this 90 dBHL tone is in
4
relation to this particular listener’s threshold. This listener has a 70 dB hearing loss at this
frequency, so the 90 dBHL tone, which would be 90 dB above a normal-hearing listener’s
threshold, is only 20 dB above this particular listener’s threshold.
17. 42 dBSPL: The pressure version of the formula was derived from the intensity version through
algebraic manipulations, so they have to be equivalent to one another. The next problem was
designed to illustrate how this can be the case.
18. (a) 1,000,000 times (6 factors of 10) more intense than IR. (b) If the intensity ratio is 1,000,000,
the pressure ratio has to be the square root of 1,000,000, which is 1,000. (c) dBSPL = 20 log
1,000 = 20 . 3 = 60 dBSPL. This is exactly what we got for the same sound measured in dBIL. It
will always be the same. If a sound measures 60 dBIL, that same sound will measure 60 dBSPL.
19. (a) 10,000 times (4 factors of 10) more intense than IR. (b) If the intensity ratio is 10,000, the
pressure ratio has to be the square root of 10,000, which is 100. (c) dBSPL = 20 log 100 = 20 . 2
= 40 dBSPL. This is exactly what we got for the same sound measured in dBIL. It will always be
the same. If a sound measures 40 dBIL, that same sound will measure 40 dBSPL.
20. See below. The lower of the two marks is 20 dB (2 factors of 10) above the constant reference
line of 0.0002 dynes/cm2. The higher of the two marks is 20 dB (also 2 factors of 10) above the
curvey line, which is the threshold of audibility for the average normal-hearing listener.
21. The full derivation is given in the Physics of Sound chapter.
5
Frequency
in Hz
125
250
500
750
1000
1500
2000
3000
4000
6000
8000
Threshold
in dBSPL
45.0
25.5
11.5
8.0
7.0
6.5
9.0
10.0
9.5
15.5
13.0