Bicycle Stress Echocardiography Protocol Equipment: 1. 2. 3. 4. 5. 6. 7. Recumbent bicycle attached to an echo bed with cut outs for imaging 12-lead ECG monitoring unit that connects to an echo machine Prep materials for skin – alcohol, gauze, razor and abrasive tap Electrodes Automatic blood pressure unit IV and contrast supplies Pre-printed bike stress worksheets Staff: 1. Sonographer 2. ECG Technologist 3. Supervising Physician Pre Test: Reminder notice sent to patient before the day of the procedure to wear comfortable clothing and shoes No eating or drinking 2 hours before the test Personal medications are taken as prescribed unless otherwise instructed by Physician Day of - introductions, patient ID confirmed, test explanation and time for questions to be answered Written consent to proceed with test If client is an inpatient, check ID band If the staff determines the patient will not be able to pedal the bike on their side the supervising Physician must assess and change the test accordingly If the supervising Physician is not available, the test is postponed until the patient is reassessed Have patient undress from the waist up and put on a gown Skin prep and application of 12-lead ECG electrodes ensuring a good ECG signal on both machines Baseline ECG supine and standing Baseline blood pressure Height, weight and BSA Cardiac history, allergies and a list of current medications – if patient is taking beta blocker patient may not reach a high enough maximum heart rate. Harness patient to the bed comfortably, put on shoe covers and place feet in footholds, then tilt bed for preliminary images Ensure the patient’s legs are not over-extended or under-extended: important the patient is comfortable while pedaling Choose the continuous capture stress package Store the resting images as required - example apical 4, then apical 2, then PLAX, then PSAX - decide at this time whether contrast will be needed Page 1 of 3 Do measurements and EF at rest Return patient to a supine position - explain about the pedaling, the stages, the lights and a quick practice pedal before starting Exercise Test: Have patient pedal until green light comes on Start ECG timer and bike timer at the same time Do a blood pressure every 2 minutes and multiply the systolic blood pressure number by the heart rate at each stage for the RPP (Rate Pressure Product) A minimum RPP of 20,000 is required to make it a readable test Monitor for symptoms and arrhythmias throughout test If the patient is having symptoms or arrhythmias or any other problem - the supervising Physician must be made aware and assess patient to determine if test should continue Each stage is 2 minutes long as preset into the ECG monitor and ultrasound machine Have patient continue pedaling each stage until they reach an end point Tilt bed again for peak images - decrease workload by 2 stages; have patient continue pedaling while peak images are being acquired When images have been acquired, patient can stop pedaling Start the recovery phase on the treadmill Document length of time biked, watts, RPP, symptoms, vitals, and any arrhythmias Post Test: When heart rate below 100 beats/ min Post images can be taken Position patient back in a supine position, remove feet from pedal boots and remove harness Wash chest, help dress and assess patient Sanitize the echo bed, harness, ECG leads, blood pressure cuff, transducer and pillow after each patient End Points: Moderate or severe angina ST elevation > than 1 mm or depression > 2 mm Nausea and other symptoms with an abrupt change in vital signs Frequent serious arrhythmias - VT, heart block, rapid sustained SVT Technical difficulties with equipment Patient refuses to continue test Regional wall motion seen Contraindications: Acute cardiac events or ECG changes - uncontrolled arrhythmias at rest Recent MI Unstable angina Page 2 of 3 Severe pathology found in pre images - aortic stenosis, intracardiac mass, pericardial effusion - all pathology must be reviewed by the supervising Physician Severe hypertension - systolic > 225 and diastolic > 110 mmhg Patient refuses the test after explanation and questions have been completed Bike Exercise Stress Worksheet: Should include the following columns: Example Bike Protocol Watts Heart Rate Blood Symptoms and comments Pressure Rest Stage 1 Stage 2 ( 0-2 min) ( 2-4 min ) xx 10 30 60 82 100 130/70 148/66 160/80 Stage 3 ( 4-6 min ) 60 121 186/90 Stage 4 ( 6-8 min ) 90 155 194/92 Mets 8.60 RPP 194 x 155 = 30,070 Recovery Exercise time 7 min 12 sec mild dyspnea dyspnea legs sore, burning in chest, dyspnea stopped chest pains oxygen and nitro given Interpretation of Bicycle Stress Echocardiography Due to the limitations of the bike stress echo, this test is not indicated for everyone. Patients should be assessed prior to performing the test. Conditions such as fibromyalgia, rheumatoid arthritis, peripheral vascular disease can affect the test RPP making it inconclusive for CAD. Criteria for Reporting: Negative test: all segments that were active and augmenting at baseline and remain active with exercise, plus a decrease in overall cavity size and improvement in overall contractility Positive test: Two or more adjacent segments—which demonstrated normal thickening at baseline but decreased or absent thickening with stress—in at least 2 imaging planes Indeterminate test: All other responses, with an explanatory note Page 3 of 3