Download Complete Measurement of the Bi-Photon Wave Function by Ultra

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts
no text concepts found
Transcript
FRISNO 2013, Ein Gedi
Measuring the Wave-Function
of Broadband Bi-Photons
Yaakov Shaked, Roey Pomeranz, Avi Pe’er
Rafi Vered, Lena Kirjner, Michael Rosenbluh
Physics Dept. and BINA center for nanotechnology, Bar Ilan University
$$
ISF, EU-IRG,
Kahn Foundation
How to make a Ti:Sapphire laser tap-dance –
Posters M17, T23
Outline
 Why

ultra broadband photon pairs?
Measuring time-energy entanglement
◦ HOM interference
◦ SFG correlation



Measuring the two-photon phase with
quantum pairwise interference
Non-classical nature – Fringe contrast
FWM – Observe the entire quantum-toclassical transition
Time-Energy Entangled Photons
pump
p
non linear
crystal
signal
s
p
i
idler
 s  i   p
s  i  ?
The two-photon state (monochromatic pump)
  0    d g ( ) 1
Entanglement
g ( )
0 
,10 


Time-Energy Correlation
  (1   ) 0    d g ( ) 1
uncertainty
relation
p / 2 
t s  ti  ?
1
2
ts  ti 
the two-photon
wave function
(monochromatic pump)
,1 p / 2 
t s  ti  1

1  10 fs

(t s , ti )  G(t s  ti )
t s  ti
Ultra-Broadband bi-Photons
Zero Dispersion !
PPKTP
Pump
880nm
DC Spectrum
Spectral Intensity [a.u]
8
7
6
5
4
3
“Single cycle”
bi-photons
2
1
110
130
150
170
190
210
Angular Frequency (THz)
230
250
Why ultra-broad photon pairs ?
Because there are so many of them !
1
1
1






 max    1014 pairs / s  12W
Standard detection does not work
Need new schemes !
Measuring entanglement - HOM
1
BS
2
Limitations:
 Phase sensitivity, but no phase
measurement
 Only for indistinguishable photons
 Not directly applicable for collinear
configuration
Measuring entanglement - SFG
Computer
Beam
dump
IR
detector
Pump
532nm
Down-converting
crystal
SPCM
up-converting
crystal
PRL 94, 043602 (2005) , PRL 94, 073601 (2005)
Efficient two-photon interaction

I SFG  2 n  n 2
Limitations:
 Phase sensitivity, but no phase
measurement
 Very low SFG efficiency ! (10-8)

Quantum two-photon interference
What if we let the pump pass ?
“Frustrated Two-Photon Creation via Interference" , T. J. Herzog, J. G.
Rarity, H. Weinfurt & A. Zeilinger, Phys. Rev. Lett. 72, 629-632 (1993).
CCD
camera
Pump laser
(880nm)
Crystal 2
Crystal 1
300
Pump
power meter
250
Intensity [Arb]
200
150
60%
60%
100
50
SFG efficiency = 60%
Inherent phase stability !
0
100
150
200
Freq. [THz]
250
Reconstruct the spectral phase
20
300
15
200
10
100
5
0
100
150
200
250
 Phase mismatch
 Dispersion from the dielectric mirrors
What is non-classical ?
Classical fringe contrast
A
Pump laser
(880nm)
e gz  e  gz
F  gz
 tanhgz
 gz
e e
B
Crystal 2
Crystal 1
A
B
CCD
camera
Pump
power meter
Measure of the
two-photon purity
Now to FWM…
Four Waves Mixing
Down conversion
pump
non linear
crystal
pump
non linear fiber
signal
idler
idler
energy
conservation
p
momentum
conservation
(phase matching)
signal
s
i

ki

ks

kp
ωi
2ωp
ki
ωs
ks
2kp
The Experiment
6ps
PCF
Dispersive
window
Ti:S Laser (6ps)
Spontaneously generated
signal-idler (ASE)
Spectrometer
Pump from supercontinnum generation!
Different
filterINCOHERENT – No comb
Unique regime compared to CW – High gain
Can cover the full Quantum-Classical
transition
Rafi Z. Vered, Michael Rosenbluh, and Avi Pe’er,
“Two-photon correlation of broadband-amplified spontaneous fourwave mixing”, Phys. Rev. A 86, 043837 (2012)
FWM and TWM – Differences…
Four Waves Mixing
Down conversion

As  iAp A*i e ik  z
z

Ai  iAp A s* e ik  z
z


2

As  i 2 Ap As  Ap2 A*i e ik  z
z
2

Ai  i 2 Ap Ai  Ap2 As* e ik  z
z
Rescale equations

Bs  iAp2,0 B e
z
 k  2 A 2  z

i

p 

2
*


Bi  iAp ,0 B s e
z
2
i  k  2 Ap  z
*


i
Bs ,i  As ,i e
2
 2 i A p z
Generalized phase
mismatch
  k  2 Ap
2


FWM Gain Solution
Signal/idler solution
Bs ,i  bs ,i e g  z e
g   Ap
2
4
 i 2
z
 2

4
g   k   Ap
2
k 2

4
Ap z, t   Ap z  0, t e
Similar to 3-waves,
but…
Ap
2
  0 
2
i Ap z
k
2
Gain only when Δk<0 !
Gain also when Δκ≠0 !
Correlation ?
Threshold pump intensity !
FWM results (Fresh)
At zero dispersion - 784nm (Δk≈0)
1
Classical
0.9
0.8
0.7
0.6
0.5
Threshold0.4
0.3
?
0.2
0.1
1
1
0
0.8
0.4 0.9
0.8
0.7
0.7
0.6
0.6
0.9
0
0.2
0.6
0.8
1
0.5
Full Quantum-classical
transition !
0.4
0.3
788nm
786nm
0.2
0.5
0.4
0.3
0.2
0.1
0.1
0
0
0
0.2
0.4
0.6
0.8
1
0
0.2
0.4
0.6
0.8
1
Conclusions
A source of collinear “single cycle” bi-photons
 Huge ‘Homodyne’ Gain in two-photon efficiency
(~40%) with pump inserted into the 2nd crystal
 Holographic measurement of the spectral phase of
the bi-photons by pairwise interference
 Fringe contrast is a quantum signature – “Measure
quantum correlation by trying to undo it…”
 Observation of the entire classical-quantum
transition with FWM in fiber
 Inherently stable collinear interferometer –
No locking needed
 Many things we don’t understand yet…

Related documents