* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Radiation Sources in medicine diagnostic Radiology Fluoroscopy IAEA International Atomic Energy Agency Day 7 – Lecture 1(2) Objective • To become familiar with of fluoroscopy equipment; • To become familiar with specific radiation risks associated with this type of equipment. IAEA 2 Contents • Description of fluoroscopy x-ray systems. • Equipment malfunction affecting radiation protection. IAEA 3 Fluoroscopic Equipment • • • Fluoroscopic equipment uses electronic image intensifiers to provide real-time (dynamic) imaging; Fluoroscopy is used for the dynamic evaluation of functional disorders and guidance during routine surgical procedures, biopsies, etc. Fluoroscopy is used during interventional radiology procedures. IAEA 4 Fluoroscopic Equipment (cont) General purpose fluoroscopic system IAEA 5 Fluoroscopic Equipment (cont) Mobile fluoroscopic system for routine procedures during surgery IAEA 6 Fluoroscopic Equipment (cont) All fluoroscopic units shall use an image intensifier, and: • shall have an exposure control switch that energises the x-ray tube only when continually pressed (i.e. a dead man control); • should allow the user to choose between continuous or pulsed x-ray generation. IAEA 7 Fluoroscopic Equipment (cont) Direct fluoroscopy should no longer be used. • “Direct” fluoroscopy does not use electronic image amplification. The real-time image is viewed on a fluorescent screen in a completely darkened room and requires the fluoroscopist to dark adapt for approximately 20 minutes before the examination. • Improper attention to these requirements can significantly increase the radiation dose to patients and users. IAEA 8 Fluoroscopic Equipment (cont) All fluoroscopic units: • shall display the instantaneous values of x-ray tube voltage (kV peak), tube current (mA) and accumulated fluoroscopic exposure time at the control or to the user. • should be provided with a Dose-Area Product metre or a measuring system to indicate patient exposure. • The dose rate at the image intensifier input phosphor shall not exceed the relevant IEC recommended values. IAEA 9 Fluoroscopic Equipment (cont) • Manual collimation of the fluoroscopic x-ray beam should be possible in addition to automatic collimation and adjusted to (but never greater than) the effective area of the image intensifier. • If the fluoroscopic unit is capable of high dose-rate operation a separate visual and / or audible warning shall be provided to the operator. • Fluoroscopic systems should incorporate a “last image hold” mode where the last few frames of the fluoroscopic image are displayed as a static image when the fluoroscopic exposure ceases. IAEA 10 Malfunctions affecting radiation protection The types of malfunctions that should be considered are: • generator and x-ray tube deficiencies listed in previous lectures • imaging system problems listed in previous lectures, especially a reduction in image intensifier conversion factor, low efficiency optics, poor resolution and contrast of the image intensifier TV chain; IAEA 11 Malfunctions affecting radiation protection (cont) • inappropriate filtration of the useful x-ray beam; • misalignment of the x-ray beam and image intensifier; • excessive dose rate (above IEC recommendations) at the image intensifier input phosphor; • inadequate or improperly adjusted shielding devices; • fluoroscopic exposure timer inaccurate or not functioning; • incorrectly calibrated patient dose measuring system. IAEA 12